Page 27

1. Summary of components

CPX I/O modules Processing signals can be evaluated with the CPX I/O ules. Input modules provide inputs for connecting sensors and enable e.g. cylinder positions to be scanned. Output modules provide universally usable electric outputs for trolling low−current consuming devices (further valves, bulbs, etc.).

Please note Including the field bus node, maximum 10 electric CPX modules plus a pneumatic interface are permitted on the electric side. The CPX I/O modules have various types of connections. The connections are on a sub−base which can be removed from the module. This offers the following advantages:

The CPX terminal can be fitted with the desired nections. It can be adapted easily to various tions and conditions of use.

When servicing is required, the electronics of the I/O modules can be replaced without the need to mantle the CPX terminal, or to loosen individual nections on the I/O modules.

For example, the following types of connection can be used:

M12 connection (protection class IP65)

M8 connection (protection class IP65)

Terminal connectors with 4 conductors (protection class IP20).

Further information on the CPX I/O modules can be found in the manual CPX I/O modules".

Festo P.BE−CPX−SYS−EN en 0503b

1−11

Page 28

1. Summary of components

CPX−CP interface The CPX−CP interface serves for connecting decentrally ranged CP modules (CP valve terminals and CP I/O modules). It transmits control signals to the connected CP modules and monitors their ability to function. Maximum 128 external I/Os are possible per CPX−CP interface. Detailed information on the CPX−CP interface can be found in the manual for the CPX−CP interface type P.

Pneumatic interface If the CPX terminal is to be fitted with valves, a pneumatic interface will be required. The pneumatic interface is the terface between the electric and pneumatic periphery. It forms the mechanical connection between the pneumatic and electric modules and transmits the electric signals. The CPX pneumatic interface is mounted on the right−hand side of the last electric module. Pneumatic interfaces can be used for e.g.:

Pneumatic interfaces for Midi/Maxi pneumatics pneumatics:

1−12 pneumatics of type Midi/Maxi (maximum 26 valve coils)

pneumatics of type CPA (maximum 22 valve coils)

pneumatics of type MPA (maximum 8 MPA pneumatic modules with a total of up to 64 valve coils).

From a technical point of view, the pneumatic interfaces for Midi/Maxi pneumatics or CPA pneumatics represent cal modules with a variable (configurable) number of digital outputs for triggering the built−in valves.

Festo P.BE−CPX−SYS−EN en 0503b

Page 29

1. Summary of components

Pneumatic interface for MPA pneumatics

The pneumatic interface for MPA pneumatics merely duces the mechanical and electrical connection to the MPA pneumatic modules. Therefore, from the point of view of the CPX terminal, the MPA pneumatic interface does not count as an electric module. Instead, the individual MPA matic modules each represent an electric module with tal outputs for triggering the integrated valves.

Detailed information on the CPX pneumatic interfaces and MPA pneumatic modules can be found in the manual for the CPX I/O modules.

Valve terminal pneumatics The valve terminal pneumatics provide the following:

the common channels for supply and exhaust air the electric signals from all valve solenoid coils.

Work connections 2 and 4 are provided for each valve tion on the individual pneumatic modules. The valves are supplied with compressed air via the common channels or via special supply modules. Both the air and auxiliary pilot air from the valves are also exhausted via these common nels. Further modules for pressure supply are also available, e.g. in order to permit work to be carried out with different work pressures.

Festo P.BE−CPX−SYS−EN en 0503b

1−13

Page 30

1. Summary of components

Valve terminal pneumatics of type Midi/Maxi Valve terminal pneumatics of type Midi/Maxi are also built up on a modular basis. These valve terminal pneumatics consist of Midi and Maxi valves. Valves of both sizes can be operated together on a CPX terminal. In this way adaptation to the quirements of the machine or system can also be made on the pneumatic side. The valve locations can be configured in steps of two from 26 valve locations. Unused valve locations can be sealed with blanking plates.

1 Pneumatic face for Midi/Maxi

1

2

2 Valve terminal pneumatics of type Midi/Maxi

3 Right−hand end

3 plate

4 Maxi valves 5 Midi valves

5

4

CPX terminal with Midi/Maxi pneumatics

1−14

Festo P.BE−CPX−SYS−EN en 0503b

Page 31

1. Summary of components

Valve terminal pneumatics of type CPA Valve terminal pneumatics of type CPA are distinguished by compact exterior dimensions in proportion to the high flow rates. They have replaceable valve plates which are mounted on sub−bases. The sub−bases are connected mechanically by tie rods and have an end plate at the side. Valve plates are available in different sizes. The valve locations can be configured in single steps from 22 valve locations.

1 Pneumatic interface for CPA (here CPA10)

1

2

2 Valve terminal pneumatics of type CPA

3 End plates 4 Valve plates

ÌÌ Ì ÌÌ Ì ÌÌ Ì 3 4

3

CPX terminal with CPA pneumatics

Festo P.BE−CPX−SYS−EN en 0503b

1−15

Page 32

1. Summary of components

Valve terminal pneumatics of type MPA MPA pneumatics consist of serially linked MPA pneumatic modules. From a technical viewpoint, the MPA pneumatic modules in a CPX terminal represent digital output modules for controlling the integrated valves (valve solenoid coils). The pneumatic interface for MPA pneumatics merely produces the mechanical and electrical connection to the MPA pneumatic modules. Valves in various sizes are also available for CPX valve minals with MPA pneumatics. 4 to 32 valve locations per CPX valve terminal are possible:

1 Pneumatic interface for MPA pneumatics

MPA1 pneumatic modules occupy 8 outputs for max.

MPA2 pneumatic modules occupy 4 outputs for max.

1

2 3

2 Valve terminal pneumatics of type MPA (here with MPA1 pneumatic modules)

3 Right−hand end plate

4 MPA1 pneumatic

4 5

4 modules

5 Supply plate CPX valve terminal with MPA pneumatics Further information on the pneumatics of your CPX valve minal can be found in the appropriate Pneumatics Manual. 1−16

Festo P.BE−CPX−SYS−EN en 0503b

Page 33

1. Summary of components

CPX terminals without pneumatics CPX terminals without pneumatic modules possess an end plate instead of the pneumatic interface. Such a set up vides digital and analogue inputs and outputs on the relevant field bus. Maximum 10 electric modules including the field bus node are permitted on a CPX terminal.

1 Field bus node

1

2

2 I/O modules 3 Right−hand end plate

4 Left−hand end plate

4

3

CPX terminal as field bus I/O slave

Festo P.BE−CPX−SYS−EN en 0503b

1−17

Page 34

1. Summary of components

1.1.2

Structure of the electric CPX modules An electric CPX module always consists of:

a manifold sub−base (with system supply, with tional supply for outputs, for valves or without supply)

an electronic module with I/O modules: a sub−base of the user’s choice.

1 Sub−base (as desired)

1

2 Electronic module 3 Manifold sub−base (as desired)

2

3 Structure of the CPX modules (example) Sub−base

1−18

The upper part of the housing selected for the CPX I/O ules is called the sub−base. Sub−bases provide the necessary connections for sensors and actuators. CPX I/O modules can be combined with the various sub−bases. In this way, the CPX terminal offers a high degree of flexibility with regard to adaptation to different applications and conditions of use.

Festo P.BE−CPX−SYS−EN en 0503b

Page 35

1. Summary of components

Electronic module

The electronic module contains the electronic components. It is connected to the manifold and to the sub−base by means of electric plug connectors. With CPX field bus nodes the connections are fixed nents of the module. The CPX I/O modules have various types of connections.

Manifold sub−base

The lower part of the housing of the electric modules is called the manifold sub−base. Manifold sub−bases serve for the trical and mechanical linking of the modules. They offer e.g. a connection for supplying the operating voltage and/or load voltage and transmit the operating and load voltages to the neighbouring modules (see section 1.1.3). The mechanical link between the electric modules is made via tie rods in the manifold sub−bases. You can replace electronic modules with sub−bases during servicing without the need to dismantle the CPX terminal or loosen individual connections. Instead the complete sub−base is removed, the electronic module replaced and the sub−base placed into position again (see manual for the CPX I/O ules).

Festo P.BE−CPX−SYS−EN en 0503b

1−19

Page 36

1. Summary of components

1.1.3

The power supply concept of the CPX terminal The operating and load voltage supplies for the CPX terminal are provided via manifold bases. These transmit the ing and load voltages to the neighbouring modules. A tion is made between the following designs:

Manifold base

Description Type CPX−GE−EV−S... 1) Manifold base with system supply: Operating voltage for internal electronics and for the internal electronics of the CP modules connected to the CPX−CP interface Sensor supply for internal input modules and for the CP input modules connected to the CPX−CP interface Load voltage supply for internal output modules and valves Load voltage supply for the CP modules connected to the CPX−CP interface Type CPX−GE−EV−Z... 2) Manifold base with additional supply for electric outputs: Load voltage supply for the output module inserted and for the subsequent output modules inserted to the right

Type CPX−GE−EV−V... 2) Manifold base with additional supply for valves: Load voltage supply for the pneumatic modules/valves inserted subsequently to the right Load voltage supply for CP modules which are connected to the fitted CPX−CP interface and to those CPX−CP interfaces subsequently fitted to the right Manifold sub−bases with a power supply are available with the following connections: M18 plug, 4−pin 7/8" plug, 4−pin 7/8" plug, 5−pin (only as CPX−GE−EV−S−7/8... and CPX−GE−EV−Z−7/8...) The manifold sub−base with a system supply facilitates electrical isolation of the load voltage for outputs/valves for the operating voltage of electronics/sensors. 1) Must be provided exactly once for each CPX valve terminal. 2) Optional depends on the current consumpt. of the CPX modules and the connected components.

Manifold bases of the CPX valve terminal − part 1

1−20