Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 18 of 26

CPX terminal Electronics manual: System description, installing and commissioning CPX terminals: Parameters and data of the CPX terminal, pages 143 to 152

Pages 143 to 152 of 221, from CPX terminal Electronics manual: System description, installing and commissioning CPX terminals

The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Festo CPX-CP-4-FB

Page 143

Parameters and data of the CPX terminal

Appendix B

Festo P.BE−CPX−SYS−EN en 0503b

B−1

Page 144

B. Parameters and data of the CPX terminal

Contents

B.

Parameters and data of the CPX terminal . . . . . . . . . . . . . . . . . . . . . . . . . . .

B−1

B.1 B.2

Access to internal parameters and data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B−4 Description of the parameters and data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B−5 B.2.1 Overview of the function numbers . . . . . . . . . . . . . . . . . . . . . . . . . . B−6 B.2.2 System parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B−9 B.2.3 Module parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B−15 B.2.4 Diagnostic memory parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . B−23 B.2.5 Diagnostic memory data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B−29 B.2.6 System−Diagnostic data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B−32 B.2.7 Module diagnostic data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B−34 B.2.8 System data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B−37 B.2.9 Module data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B−43

B−2

Festo P.BE−CPX−SYS−EN en 0503b

Page 145

B. Parameters and data of the CPX terminal

Contents of this appendix

Further information

This appendix describes the composition of all parameters and data of theCPX terminal. By means of the specified tion number you can:

have read access to the parameters and data via the I/O diagnostic interface establish a reference to parameters and data in other manuals.

General basic principles of parameterisation can be found in Appendix C. Information on the parameters and data which are supported by the field bus used, can be found in the manual for the field bus node used. Instructions on parameterisation via the handheld can be found in the manual for the handheld.

Festo P.BE−CPX−SYS−EN en 0503b

B−3

Page 146

B. Parameters and data of the CPX terminal

B.1

Access to internal parameters and data The CPX terminal permits access to internally saved data and parameters. The ways in which you can access these data and parameters depend on the field bus protocol used. For example access can be made via:

the plug−in module or scanner/bus master; e.g. for anteeing the desired parameterisation of the CPX terminal in the start−up phase or after field bus interruptions.

field bus specific configurators, e.g. during the sioning phase or during a search for faults the user program in the higher−order PLC/IPC, e.g. for modifying parameters or system features during ation the handheld, e.g. during the commissioning phase or during a search for faults the I/O diagnostic interface, e.g. for reading out tic data.

Data can be read. Parameters can be read and modified. Only read access to parameters and data by means of the relevant function number is possible via the I/O diagnostic interface (see section 5.2.2).

B−4

Festo P.BE−CPX−SYS−EN en 0503b

Page 147

B. Parameters and data of the CPX terminal

B.2

Description of the parameters and data A distinction is made between the following parameters and data: Parameters

Description

System parameters

Determine global system functions for the complete CPX terminal, e.g.: diagnostic monitoring system start etc.

Module parameters

Determine module−specific and channel−specific functions for the relevant module, e.g.: input debouncing time signal extension times etc.

Diagnostic memory parameters

Determine the working method of the diagnostic memory.

Data

Description

System−Diagnostic data

Global information on the system status (e.g. common diagnostic message)

Module diagnostic data

Information on locating faults (e.g. error ber, number of the first faulty channel etc.)

Diagnostic memory data

Entries in the diagnostic memory (max. 40)

System data

Information on global system settings

Module data

Series number, revision code and module code of the modules used

Festo P.BE−CPX−SYS−EN en 0503b

CPX parameters

CPX data

B−5

Page 148

B. Parameters and data of the CPX terminal

B.2.1 Overview of the function numbers Function no. 1)

CPX data and CPX parameters

See

0

CPX operating mode (system data)

0

CPX equipment fitted (system data)

0

Handheld (system data)

0

Force mode (system data)

0

System start (system data)

1

Fail safe (system data)

1

System idle mode (system data)

2

Monitoring CPX terminal (system data)

16 +16m + 0

Module code (module data)

16 +16m + 13

Revision code (module data)

784 + m * 4 + 0 784 + m * 4 + 1 784 + m * 4 + 2 784 + m * 4 + 3

Series number (module data)

1936

Status bits (system diagnostic data)

1937

Module number and diagnostic status (system diagnostic data)

1938

Error number (system diagnostic data)

2008 + m * 4 + 0

Number of the first faulty channel (module diagnostic data)

2008 + m * 4 + 1

Module error number (module diagnostic data)

2008 + m * 4 + 2

Information 2 (module diagnostic data)

2008 + m * 4 + 3

Information 3 (module diagnostic data)

3480

Entries remanent with Power ON (diagnostic memory parameters)

3480

Run/Stop filter 1 (diagnostic memory parameters)

1) m = module number (counting on the modules from left to right, beginning with 0)

B−6

Festo P.BE−CPX−SYS−EN en 0503b

Page 149

B. Parameters and data of the CPX terminal

Function no. 1)

CPX data and CPX parameters

See

3482

Number of entries in the diagnostic memory (diagnostic memory data)

3483

Overrun (diagnostic memory data)

3483

Status (diagnostic memory data)

3484

Run/Stop filter 2 (diagnostic memory parameters)

3484

End of fault filter (diagnostic memory parameters)

3484

Error number filter (diagnostic memory parameters)

3484

Module/channel filter (diagnostic memory parameters)

3485

Module number MN (diagnostic memory parameters)

3486

Channel number CN (diagnostic memory parameters)

3487

Error number FN (diagnostic memory parameters)

3488 + n

Diagnostic memory data (diagnostic memory data)

4401

Monitoring (system parameters)

4402

Fail safe (system parameters)

4402

Force mode (system parameters)

4402

System idle mode (system parameters)

4402

System start (system parameters)

4828 + m * 64 + 0

Monitoring the CPX module (module parameter)

4828 + m * 64 + 1

Reaction after short circuit/overload (module parameter)

4828 + m * 64 + 1

Input debouncing time (module parameters)

4828 + m * 64 + 1

Signal extension time (module parameters)

4828 + m * 64 + 3

Data format for analogue value of inputs (module parameters)

4828 + m * 64 + 3

Data format for analogue value of outputs (module parameters)

1) m = module number (counting on the modules from left to right, beginning with 0)

Festo P.BE−CPX−SYS−EN en 0503b

B−7

Page 150

B. Parameters and data of the CPX terminal

Function no.

Channel−specific module parameters

See

− 1)

Signal extension channel x

− 1)

Monitoring wire fracture channel x

− 2)

Fail safe channel x

− 2)

Idle mode channel x

− 2)

Force channel x

1) Function number see manual for CPX modules 2) Access is protocol−specific (see manual for field bus node)

Function no.

Field−bus specific system data

See

Number of input bytes (Rx size) 1)

Number of output bytes (Tx size) 1)

1) Only relevant with certain field bus protocols (see manual for CPX field bus node)

B−8

Festo P.BE−CPX−SYS−EN en 0503b

Page 151

B. Parameters and data of the CPX terminal

B.2.2 System parameters The system parameters refer to global functions of the CPX terminal. The following system parameters are available: Function no.

System parameters

4400

Reserved

4401

Monitoring (active/inactive)

4402

Fail safe (reaction to communication faults)

4402

Force mode (enable/block force)

4402

System Idle mode (reaction when changing into the Idle status) 1)

4402

System start

1) Only relevant with certain field bus protocols (see manual for CPX field bus node)

Overview System parameters

[........]

In this description, the data and parameters displayed on the handheld in English are framed in the text in brackets, e.g. [Debounce time]. In the text, a fuller description pears next to it, e.g.: input debouncing time

Festo P.BE−CPX−SYS−EN en 0503b

[Debounce time]

B−9

Page 152

B. Parameters and data of the CPX terminal

System parameters: Monitoring Function no.

4401

Description

The monitoring of short circuit/overload and undervoltage for the complete CPX terminal can be activated or deactivated (suppressed). Active monitoring causes the following: A fault registered by the module will be: sent to the higher−order field bus master entered, if applicable, in the diagnostic memory (depending on filter settings) entered in the module diagnostic data and, if applicable, in the status bits displayed by the module common error LED displayed by the red on the node Monitoring Description Short circuit/overload in sensor supply

[Monitor]

Bit 0 1

Short circuit/overload at the outputs

[Monitor SCO]

2

Undervoltage at the outputs (VOUT)

[Monitor VOUT]

3

Undervoltage at valves (VVAL)

[Monitor VVAL]

4

Short circuit at the valve

[Monitor SCV]

5...7

[Monitor SCS]

Reserved

Values

1 = Active (presetting) 0 = Inactive

Note

The method of operation of the channel fault LED remains unaltered. Monitoring can also be set separately for each module (see module parameter monitoring CPX module).

B−10

[Active] [Inactive]

Monitoring short circuit/overload/undervoltage

Festo P.BE−CPX−SYS−EN en 0503b