Page 65
2. Fitting
4. Fit a hat−rail clamping unit to both the left and the right− hand end plates and the pneumatic interface of the CPX terminal. 5. Hang the CPX terminal onto the hat rail (see arrow A).
1 Hat rail 2 Clamping element of the hat rail clamping unit
3 Locking screw of the hat rail clamping unit
ÔÔÔÔÔ ÔÔÔÔÔ ÔÔÔÔÔ ÔÔÔÔÔ ÔÔÔÔÔ ÔÔÔÔÔ ÔÔÔÔÔ ÔÔÔÔÔ ÔÔÔÔÔ
ÓÓ ÓÓ ÓÓ ÓÓ ÓÓ ÓÓ ÓÓ ÖÖ ÓÓ ÓÓ ÓÓ ÓÓÓÓ ÓÓ ÓÓ ÓÓ
A
1
2 3
B
Fitting a CPX terminal (here with CPA pneumatics) onto a hat rail 6. Swing the CPX terminal onto the hat rail (see arrow B). Make sure that the clamping element lies horizontally to the hat rail.
Festo P.BE−CPX−SYS−EN en 0503b
2−21
Page 66
2. Fitting
7. Fasten the CPX terminal against tilting or sliding by tightening the locking screws with 1.3 Nm.
1 Hat rail 2 Clamping element of the hat rail clamping unit
1 2
Rear view: Fitting the CPX terminal onto a hat rail
2−22
Festo P.BE−CPX−SYS−EN en 0503b
Page 67
2. Fitting
2.3.3
Fitting CPX terminals with Midi/Maxi pneumatics onto a hat rail For fitting the valve terminal onto the hat rail you will require a hat−rail clamping unit type CPX−03−4,0 (Midi) or type CPX−03−7,0 (Maxi).
Caution A hat−rail fitting without a hat−rail clamping unit is not permitted. · If the terminal is fitted in a sloping position or if it is jected to vibration, secure the hat−rail clamping unit additionally against sliding down and against unintentional the locking screws (see item 6) with the locking screws intended for this purpose (item 6).
Please note If the terminal is fitted in a horizontal position and the load is at rest, it is not necessary to use the screws to secure the hat−rail clamping unit (see item 6). If your terminal does not have a hat−rail clamping unit, you can order this and fit it at a later stage. Whether Midi or Maxi clamping elements are to be used depends on the end plates fitted (Midi/Maxi). The CPX terminal has been prepared for fitting onto a wall. To compensate for the difference in height, two spacer rings have therefore been placed on both the right−hand end plate and on the pneumatic interface at the factory. ·
Festo P.BE−CPX−SYS−EN en 0503b
Recommendation: Use a suitable tool to remove the upper spacer rings (e.g. scratch them off with a driver). There is then sufficient space to hang the terminal on the hat rail.
2−23
Page 68
2. Fitting
1 Remove the spacer rings
1 1
Rear view: Spacer rings on the right−hand end plate and the pneumatics interface The hat rail clamping unit must be fastened to the rear of the right−hand end plate and the pneumatic interface as shown in the following diagram. Before fitting ·
Glue the rubber feet on. Make sure that the surfaces to be glued are clean (clean with spirit).
·
Tighten the flat−head screws (see item 3).
·
Make sure that the spacer rings have been removed.
After fitting ·
2−24
Secure the levers with the aid of the locking screws item 6).
Festo P.BE−CPX−SYS−EN en 0503b
Page 69
2. Fitting
3 2 1
4 5
6
1 Lever *)
4 Self−adhesive rubber foot
2 O−ring
5 Clamping elements
3 Flat−head screw
6 Locking screw
*)
Different lever lengths with Midi and Maxi
Fitting the hat rail clamping unit Fit the hat rail as follows: 1. Make sure that the fastening surface can support the weight of the CPX terminal. 2. Fit a hat rail (support rail as per EN 60715 35x15; width 35 mm, height 15 mm). 3. Fasten the hat rail at least every 100 mm to the fastening surface.
Festo P.BE−CPX−SYS−EN en 0503b
2−25
Page 70
2. Fitting
4. Hang the terminal onto the hat rail. Secure the valve minal on both sides with the hat−rail clamping unit against tilting or sliding down (see 5. With a vibrating load or if the node is fitted in a sloping position, secure the hat rail clamping unit against unintentional loosening or opening with two locking screws item 4).
1
2
4
3
1 Hat rail
3 Hat−rail clamping unit locked
2 Hat−rail clamping unit unlocked
4 Locking screw
Top view: Fitting the valve terminal onto a hat rail
2−26
Festo P.BE−CPX−SYS−EN en 0503b
Page 71
2. Fitting
2.3.4
Fitting onto a wall The end plates and the pneumatic interface contain holes for fitting the terminal onto a wall. For CPX terminals with Midi/Maxi pneumatics: To compensate for the difference in height between the matic and the electrical sides of the CPX terminal, spacer rings have been fitted to the pneumatic interface and to the right−hand end plate at the factory.
Caution When fitted onto a wall, the CPX terminal can bend and be damaged in the following cases: when fitted to an uneven, flexible surface when fitting CPX terminals with Midi/Maxi pneumatics without spacer rings onto a wall. Fit the CPX terminal only onto a flat fixed surface. Make sure that the spacer rings are fitted before you mount the CPX terminal with Midi/Maxi pneumatics.
Caution Overstressing the fastening holes, bending the CPX terminal or internal vibrations can cause damage. In these cases, use additional fastenings type CPX−BG−RW−10X approx. every 100 or 150 mm. Fastenings of type CPX−BG−RW−10X can be clipped into two electric modules placed together and offer additional lities for fitting onto a wall.
Festo P.BE−CPX−SYS−EN en 0503b
2−27
Page 72
2. Fitting
1 Fit the fastenings 2 Clip the 1 ings into place
2
Fitting fastening type CPX−BG−RW−10X For fitting onto a wall, proceed as follows: 1. Make sure that the fastening surface is flat and can port the weight of the CPX terminal. 2. Check whether you need additional fastenings of type CPX−BG−RW−10X for the I/O module (if applicable, approx. every 100 or 150 mm). 3. With CPX terminals with Midi/Maxi pneumatics: Make sure that the spacer rings have been fitted. 4. With CPX terminals with MPA pneumatics: Check whether you need additional wall supports for the pneumatics module (see MPA pneumatics manual). 5. Fasten the CPX terminal with two screws on both the left and right−hand end plates and with two screws on the pneumatic interface. The valve terminal can be fitted in any position. Make sure there is sufficient space for connecting the power cables and compressed air tubing.
2−28
Festo P.BE−CPX−SYS−EN en 0503b
Page 73
2. Fitting
Variants
Fastening possibilities 1
1 2 1
2
2 1
CPX terminal without pneumatics End plates: 2 screws each of size M4 or M6 1 Hole for M4 2 Hole for M6
2 CPX terminal with Midi/Maxi matics Fastening with: two M6 screws on both the left and right−hand end plates. two M6 screws on the pneumatic interface.
ÒÒ Ò ÒÒ ÒÒÒ Ò
Festo P.BE−CPX−SYS−EN en 0503b
CPX terminal with CPA pneumatics Fastening with: two M6 screws on both the left and right−hand end plates. three M6 screws on the pneumatic interface.
2−29
Page 74
2. Fitting
Variants
Fastening possibilities
1
3
2
2
1 2
1 2 1
1
MPA valve terminal with CPX terminal End plates: two screws each of size M4 or M6 Pneumatic interface: two M4 screws Fastening bracket on the supply unit (optional): one M6 screw 1 Hole for M4 screw 2 Hole for M6 screw 3 Hole for M6 screw in the wall bracket (see MPA pneumatics manual)
1
Ò ÒÒ Ò ÒÒ ÒÒÒ 1
2−30
Long CPX terminal with additional fastening type CPX−BG−RW−10X (optional) End plates: two M6 screws each Pneumatic interface: M6 screws Midi/Maxi, 3 for CPA). for each additional fastening 1 M4 screw.
Fastening possibilities for fitting onto a wall
Festo P.BE−CPX−SYS−EN en 0503b