Page 55

2. Fitting

1 The electrical

1 connection of the system supply points upwards

2

3

2 Tie rods 3 Tie rod groove

CPX terminal (rear view) 3. Press the manifold sub−bases together carefully and out tilting. 4. Place the end plate on the tie rod. 5. Make sure that the tie rods and plug connectors are rectly seated. Carefully screw the tie rod screws a few turns into the tie rods. 6. Then tighten the screws equally with a hexagon socket wrench size 3 max. 2 Nm ± 0.3 Nm.

2.2.2

Increasing or reducing the number of electric modules The length of the tie rod is determined by the possible number of sub−bases or electric modules. In order to extend the CPX terminal with a further electric module, you will quire a tie rod extension (see In order to increase or reduce the number of modules by more than one module, you must replace the tie rods by tie rods of the appropriate length. The following table contains a list of the tie rods which you will need in order to adapt the length of the tie rods to the desired number of modules.

Festo P.BE−CPX−SYS−EN en 0503b

2−11

Page 56

2. Fitting

Type

Number of modules

Description

CPX−ZA−1 CPX−ZA−2 ... CPX−ZA−9 CPX−ZA−10

1 2 ... 9 10

Tie rod sets (each contains two tie rods of the appropriate length)

CPX−ZA−1−E

+1

Tie rod extension for a further electric module (max. one tie rod extension per tie rod permitted)

Tie rod sets and tie rod extension

Fitting the tie rod extension Please note Please observe the following instructions when fitting the tie rod extension in order to avoid damage to the CPX minal:

2−12

·

Fit the tie rod extension so that it is flush with the tie rod (it need not be tightened).

Only one tie rod extension is permitted for each tie rod.

Maximum 10 electric modules including the field bus node plus a pneumatic interface are permitted for each CPX terminal.

Festo P.BE−CPX−SYS−EN en 0503b

Page 57

2. Fitting

Removing

Remove the electric modules or manifold sub−bases as follows (see also following Fig.): 1. Unscrew and remove completely the tie rod screws in the left−hand end plate (see 2. Remove the left−hand end plate from the tie rods. The manifold sub−bases are now held together only by the electrical plug connectors. 3. Removing manifold sub−bases Loosen the electrical plug connectors on the relevant manifold sub−base by taking the manifold sub−base apart carefully and without tilting it. 4. Pull the loosened manifold sub−bases away from the tie rod. 5. Removing a tie rod With the aid of a suitable tool, e.g. a screwdriver, remove the appropriate fastening and locking plate in the matic interface or in the right−hand end plate (see ing Fig.).

1 Screwdriver 2 Fastening plate and locking plate in the pneumatic interface or the right−hand end plate

1

2 Fastening plate and locking plate in the pneumatic interface

Festo P.BE−CPX−SYS−EN en 0503b

2−13

Page 58

2. Fitting

Fitting

Fit the tie rod and the electric modules or manifold sub−bases as follows (see also following Fig.):

Please note · Place subsequently ordered modules where possible after the last module before the pneumatic interface or in front of the right−hand end plate. · Do not fit more than 10 electric modules and one matic interface. · Fit modules of the same type where possible in series

(e.g. first all input modules then all output modules). This can be an advantage for the address assignment of the CPX terminal, depending on the field bus used. 1. Fasten the tie rod in the pneumatic interface or the right− hand end plate, by placing the fastening plate over the locking plate and pushing these together into the groove intended for this purpose. The locking plate must lie on the side facing the pneumatics. The hooks on the locking plate must grip into the grooves in the fastening plate.

1 Locking plate 2 Fastening plate 3 Groove for tie rod fastening

1

3

2

Fastening plate and locking plate in the pneumatic interface (example) 2. Push the manifold sub−bases onto the tie rod carefully and without tilting.

2−14

Festo P.BE−CPX−SYS−EN en 0503b

Page 59

2. Fitting

Caution When sub−bases are arranged in series: Make sure that the electric plug connectors of the manifold sub−bases are not bent. 3. Align the CPX terminal on a flat surface so that the nents are not offset. In the case of CPX terminals without pneumatics or with CPA pneumatics, you can place the CPX terminal so that the electrical connections for the system supply and, if applicable, for the additional supply point upwards. The tie rod is held in the tie rod groove by the weight force.

1 The electrical

1 connection of the system supply points upwards

2

3

2 Tie rods 3 Tie rod groove

CPX terminal (rear view) 4. Press the manifold sub−bases together carefully and out tilting. 5. Place the end plate on the tie rod. 6. Make sure that the screw connectors are seated correctly and carefully screw the tie rod screws a few turns into the tie rods. 7. Then tighten the screws equally with a hexagon socket wrench size 3 max. 2 Nm ± 0.3 Nm. Festo P.BE−CPX−SYS−EN en 0503b

2−15

Page 60

2. Fitting

2.2.3

Fitting the right−hand end plates with Midi/Maxi valves Please note With Midi/Maxi valves, the right−hand end plate is earthed internally when the valve terminal is supplied from the factory. If you undertake extensions/conversions to the valve terminal, earth the right−hand end plate of the minal as described below. In this way, you will avoid interference caused by magnetic influences. Earth the end plates after extension/conversion as follows: 1. Right−hand end plate (Midi/Maxi): In order to earth the right−hand end plate, connect the cable fitted on the inside onto the appropriate contacts pneumatic module or the node (see following gram). 2. Left−hand end plate: The left−hand end plate is connected conductively with the other components by means of rails in the sub−base. Please note: Instructions on earthing the complete valve terminal can be found in the chapter Installation". The following diagram shows you how to fit the right−hand end plates with Midi/Maxi valves.

2−16

Festo P.BE−CPX−SYS−EN en 0503b

Page 61

2. Fitting

1

2

3

4 1 Seal

3 Fastening screws

2 Pre−fitted earth cable

4 Contact for earth cable

Fitting the end plates with Midi/Maxi pneumatics

Festo P.BE−CPX−SYS−EN en 0503b

2−17

Page 62

2. Fitting

2.3

Fitting the CPX terminal You can fit the CPX terminal in one of two ways: Type of fitting

Description

Fitting onto a hat rail

The CPX terminal is suitable for fitting onto a hat rail (support rail as per EN 60715). There is a guide groove on the back for hanging the valve terminal onto the hat rail.

Fitting onto a wall

The end plates and the pneumatic face contain holes for fitting the terminal onto a wall. In the case of long CPX minals, additional fastening clips are required on the electric modules.

Methods of fitting the CPX terminal

Please note Fit the CPX terminal so that there is sufficient space for heat dissipation and ensure that the maximum limits for temperatures are observed (see Technical specifications).

2.3.1

Fitting CPX terminals without pneumatics onto a hat rail For fitting the CPX terminal without pneumatics onto a hat rail, you will require fitting kit type CPA−BG−NRH. This kit sists of 2 M4x10 screws and 2 clamping elements. Fitting onto a hat rail is carried out in the same manner as fitting CPX terminals with CPA valves onto a hat rail 2.3.2).

2−18

Festo P.BE−CPX−SYS−EN en 0503b

Page 63

2. Fitting

2.3.2

Fitting CPX terminals with CPA or MPA pneumatics onto a hat rail For fitting the CPX terminal onto a hat rail you will require fitting kit type CPX−CPA−BG−NRH. This kit consists of 3 M4x10 screws and 3 clamping elements.

Caution Hat rails fitted with CPA14 valve terminals can break if they are subjected to vibration which exceeds the following values: 0.15 mm path at 10...58 Hz 2 g acceleration at 58...150 Hz This can cause damage to the CPA valve terminal or to your machine or system. · Use the wall fitting for CPA14 valve terminals.

Caution A hat−rail fitting without a hat−rail clamping unit is not permitted. · If the terminal is fitted in a sloping position or if it is jected to vibration, secure the hat−rail clamping unit additionally against sliding down and against unintentional the locking screws (see item 3) with the locking screws intended for this purpose (item 6).

Festo P.BE−CPX−SYS−EN en 0503b

2−19

Page 64

2. Fitting

Variants

Fastening possibilities

CPX terminal with MPA pneumatics

Holes for the hat rail clamping units: 1 in the end plates 2 in the pneumatic interface

2

1

1

Holes for the hat rail clamping units: 1 in the end plates 2 in the pneumatic interface

CPX terminal with CPA pneumatics

2

1

ÒÒ Ò ÒÒ ÒÒ Ò Ò

1

Holes for the hat rail clamping unit Proceed as follows: 1. Make sure that the fastening surface can support the weight of the CPX terminal. 2. Fit the hat rail (support rail as per EN 60715 35x7.5; width 35 mm, height 7.5 mm). Make sure there is sufficient space for connecting the compressed air supply tubing. 3. Fasten the hat rail to the fastening surface at intervals of approx. every 100 mm.

2−20

Festo P.BE−CPX−SYS−EN en 0503b