Page 45

Fitting

Chapter 2

Festo P.BE−CPX−SYS−EN en 0503b

2−1

Page 46

2. Fitting

Contents

2.

Fitting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2−1

2.1 2.2

General instructions on fitting and dismantling . . . . . . . . . . . . . . . . . . . . . . . Fitting the electric modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.1 Replacing a complete module or manifold sub−base . . . . . . . . . . . 2.2.2 Increasing or reducing the number of electric modules . . . . . . . . . 2.2.3 Fitting the right−hand end plates with Midi/Maxi valves . . . . . . . . . Fitting the CPX terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.1 Fitting CPX terminals without pneumatics onto a hat rail . . . . . . . . 2.3.2 Fitting CPX terminals with CPA or MPA pneumatics onto a hat rail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.3 Fitting CPX terminals with Midi/Maxi pneumatics onto a hat rail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.4 Fitting onto a wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2−4 2−5 2−8 2−11 2−16 2−18 2−18

2.3

2−2

2−19 2−23 2−27

Festo P.BE−CPX−SYS−EN en 0503b

Page 47

2. Fitting

Contents of this chapter

The CPX terminal is already assembled when supplied from the factory. If you wish to add or remove electric modules, you must fit or remove further manifold sub−bases. This chapter describes how to fit and remove manifold sub−bases as well as how to assemble and dismantle a complete CPX terminal.

Further information

Please refer to the following manuals if you wish to replace individual electronic modules or sub−bases, or replace and add pneumatic components:

Festo P.BE−CPX−SYS−EN en 0503b

Manual for the I/O modules" for fitting and removing the module electronics and the sub−bases

Pneumatics manual" for fitting and removing the matic modules and components

The fitting instructions supplied with the product in the case of modules and components ordered at a later stage

2−3

Page 48

2. Fitting

2.1

General instructions on fitting and dismantling Warning Sudden unexpected movement of the connected actuators and uncontrolled movements of loose tubing can cause injury to human beings or damage to property. Before carrying out installation and maintenance work, switch off the following: the compressed air supply the operating and load voltage supplies.

Please note Handle all modules and components of the CPX terminal with great care. Please note especially the following: Screw connections must be fitted free of offset and mechanical tension. Screws must be fitted accurately (otherwise threads will be damaged). The specified torques must be observed. The modules must not be offset (IP65). Contact surfaces must be clean (avoid leakage and tact faults). The contacts of the Midi/Maxi valve solenoid coils must not be bent (not resistant to bending, i.e. they will break off if they are bent back). Electrostatically sensitive components Do not touch the contact surfaces of the plug connectors on the sides of the modules and components.

2−4

Festo P.BE−CPX−SYS−EN en 0503b

Page 49

2. Fitting

2.2

Fitting the electric modules Caution Modules may be damaged if they are not handled correctly. · Observe the regulations for handling electrostatically sensitive components. · Discharge yourself electrostatically before fitting or moving components in order to protect the components against discharges of static electricity. By adding or removing modules you can adapt the CPX minal to your requirements. The mechanical link between the electric modules is made via tie rods in the sub−bases. The length of the tie rod is determined by the possible number of sub−bass or electric modules. Dismantle the CPX terminal before you add or remove sub− bases. If you are using the additional fastenings of type CPX−BG−RW−... for fastening onto a wall, it may be necessary to loosen fastenings (see also

Festo P.BE−CPX−SYS−EN en 0503b

2−5

Page 50

2. Fitting

Rules for assembly

A maximum of 10 electric modules including the field bus node plus a pneumatic interface are permitted on the electrical side.

For MPA pneumatics: The MPA pneumatic interface does not count as an tric module. Instead, the individual MPA pneumatic ules each represent an electric module with digital puts for triggering the integrated valves. A maximum of pneumatic modules are permissible.

Except for the pneumatic interface, each electric module including the field bus node can be fitted in any position on the electrical side.

The electric modules can be arranged in any sequence in the CPX terminal. Depending on the field bus protocol used, it may however be sensible to arrange modules of the same type one after the other. In these cases, the address ment and therefore communication between the field bus master and the individual CPX terminals can be optimised.

2−6

The pneumatic interface must be placed on the right−hand side as the last electric module.

Sub−bases can be used universally for field bus nodes and I/O modules.

If sub−bases with additional supply are not required, the manifold sub−base with the system supply can be fitted in any desired position.

If manifold sub−bases with additional supply are required, these must always be placed to the right of the system supply (see also section 1.1.3).

Sub−bases can be used universally for the different I/O modules.

Festo P.BE−CPX−SYS−EN en 0503b

Page 51

2. Fitting

Festo P.BE−CPX−SYS−EN en 0503b

The maximum number of pneumatic components supported is as follows:

26 valve coils of type Midi/Maxi

22 valve coils of type CPA

2−7

Page 52

2. Fitting

2.2.1

Replacing a complete module or manifold sub−base The manifold sub−bases are connected to each other ically by means of two tie rods. The tie rods are situated in a groove in the housing open at the rear.

1 Tie rod groove

1

2

2 Tie rods

CPX terminal (rear view) Proceed as follows in order to remove a complete module or a manifold sub−base: 1. Dismantle the CPX terminal 2. Unscrew and remove completely the tie rod screws in the left−hand end plate (see The manifold sub−bases are held together by the electrical plug connectors.

2−8

Festo P.BE−CPX−SYS−EN en 0503b

Page 53

2. Fitting

1 Tie rod screw

1

2 Hexagon socket wrench size 3

2

1

Dismantling electric I/O modules

Caution Make sure that the electric plug connectors of the manifold sub−bases are not bent. 3. Loosen the electrical plug connectors on the relevant manifold sub−base by taking the manifold sub−base apart carefully and without tilting it. 4. Now push the modules to the left of the module to be replaced approx. 3 cm to the left. 5. Now push the module to be replaced approx. 1.5 cm to the left. 6. Make sure that the tie rod lies over the tie rod groove of the module to be replaced by shifting the module ingly (see arrow A in

Festo P.BE−CPX−SYS−EN en 0503b

2−9

Page 54

2. Fitting

1 Tie rods

1

A

2

2 Loosened module

Removing a module or manifold sub−base 7. Carefully remove the loosened module by lifting it upwards. In order to insert a module or manifold sub−base again, proceed as follows: 1. Insert the module in the desired position (see The tie rod must lie exactly over the tie rod groove.

Caution When sub−bases are arranged in series: Make sure that the electric plug connectors of the manifold sub−bases are not bent. 2. Align the CPX terminal on a flat surface so that the nents are not offset. In the case of CPX terminals without pneumatics or with CPA pneumatics, you can place the CPX terminal so that the electrical connections for the system supply and, if applicable, for the additional supply point upwards. The tie rod is held in the tie rod groove by the weight force.

2−10

Festo P.BE−CPX−SYS−EN en 0503b