The text of a manual · part 30 of 35
Series One Programmable Controllers, Series One/One Plus User's Manual: Chapter 8 Applications, pages 264 to 270
Pages 264 to 270 of 300, from Series One Programmable Controllers, Series One/One Plus User's Manual
The original document is the PDF (40 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the GE Fanuc IC610CPU105A, GE Fanuc IC610CPU105C, Fanuc IC610CPU105A, GE IC610CPU105A, Fanuc IC610CPU105C and GE IC610CPU105C
Page 264
Applications GE&=42
With this type of control application the object is to generate a pulse output every X numkr of counts. In cut to length applications X rcpments the length of material to be cut in pulses from the encoder. The following example pulses output No. 1 of the High Speed Counter once evczy 100 counts. The figurebelow shows the logic diagram for output No. 1, while the next figure contains the wiring diagram for this type of application, followed by the associated ladder logic. a40894 OUTPUT NO. 1 CURRENT COUNT
0
100
200
300
400...
Figure 846. Output No. 1 Logic Diagram
WSHSPEEDCOUNTER MOOULE
8 USER LOAD
OUTPUTNO
1 f
A+
5-24VDC
USER SUPPLIED
Y -
RESET COUNTER
DECREMENT COWTER
DECREMENT PULSE
-1 COUNTER
+lZvDc f 1O’l USER SlJPf’UED
Figure 8-17. Wiring Diagram
Page 265
Applications GEK-90842 a40005 ONE SHOTTO WITE
PRESETTOHsc
OUTPU?NO.1IN COUNTER MODEOf OPfRATION
Figure 8-18. Cut to Length Program Measuring a Random Length
.-
In measuring the length of moving objects, the leading and trailing edge of the object enables and disables the counter which is tied to the encoder. At this point the accumulate value of the counter repments the length of the object. Unfortunately the accumulate value of the High Speed Counter cannot be moved into the user logic of a Series One or Series One Plus PC. Thus an objects length can only be measured relative (> = <) to a preset value in the counter. Through the use of a shift register and multiple presets, the length can be approximated to within two successive presets. To determine the accuracy a moving objects length can be measured. Three parameters must be considered:
1. Velocity of Object (pulses/second) 2. Resolution of Encoder (inches/pulse) 3. Scan time of the Series One or Series One Plus CPU (seconds) These three factors combine in the following manner to determine the accuracy of measurement. Accuracy of Measurement = R INCH V PULSE 1.1s~ (sex)
PLJLSE
SEC
Page 266
Applications
849
GEwo842
Sample Calculation Given: 1. 0.1 inches/pulse
2. 60 RPM, assume 1 pulse/degree
= 360 pulses/second
3. Scan time 20 msec PULSE
SEC
The user logic as shown would implement I/O Definition: Ill
- Photoelectric this type of measmment giving a resolution of 10 counts.
cell which enables counter 110 - Manual Reset/initialize a40895
01 02 03 04
0s
F&we 8-19. Measuring a Random
Page 267
Appikations
8-20 a40895
0a
0 7
0
0
0a 010
0 11
0
12 n 0
0 la
CWlW 00 on
Fiire
101 10 wrrmunkV*uIETOmc
8-19 Measuring a Random Length(Continued) a40895
Fiiiiiire 8-19 Mtssuring a Random Length(Continued)
Page 268
Applications
8-21
GEK-90842 a40895
0 21
0 22
022
Figure 849 Measuring a Random Length(Continued) a40895
Page 269
Applications
8-22
Application 9 - Typical Shift Registers When applying controls to a conveyor system or indexing machine, consideration must be given to the object being assembled, since it invariably has discrete information (pass, fail, etc.) ~sociated with it. Each time that the object is advanced in the assembly process, its discrete information must follow it. The shift rqister fiuxztion provides this control within the Series One and Series One Plus PCs. Referring to the following example, the objects undergo a mechanical and visual inqxction at stations Number 1 and 3. If either inspection fails, the object is rejected at station Number 5. In order to track the pass or fail status of each object, two shift registers are required, one for the mechanical inspection and one for the visual inspection. pc-s l-83-0044
Fire
8-20. Shift Register Example
In this example, I/O and shift register references are assigned as follows: OUTPUTS
INPUTS 00
Advance belt, shift signal
01 lttkhmiealinspection
O-PI-fail 02 visual isa!gmim
Q-P03
II-fail ReaeebiftRcgista
20
Reject Arm o-off l-On
Page 270
Applications
Shift
8.23
Register References
400
First Mixcnce in mechanical inspection shift register.
401
Secondreference in medumical
402
Third reference in mechanical impection shift register.
403
Fourth reference in mechanical inpaion
410
First Itaaxe
411 second rtfezace inspection shift register.
shift register in visual inspection shift rqiskr. in visual hspection shift register.
Typical logic using these refemxes is shown in the following ladder diagram. pc-s f-83-0045 00 161 1eo
00 161
01
160
2 403
Figure 8-21. Typical Shift Register Logic