Page 128

GEK-90477

Index

INDEX

Accessing the CPU Scratch Pad, 5-44, 5-45, 5-46, 5-47, 5-48, 6-19 ACK, 6-2 Asynchronous Data Format, 6-l Cable Selection, 4-2 Cables, DCU or DCM to Workmaster through the Interface Adapter, 4-11 DCU or DCM to Workmaster Directly through the RS-422 Port, 4-12 Mul tidrop Modem Configuration, 4-10 Mul t idrop RS-422 Cable, 4-Wire, 4-5 Multidrop RS-422 Cable, 2-Wire, 4-7 Point-to-Point DCU or DCM to Series Six CCM or Host Computer, 4-5 Point-to-Point Modem Configuration, 4-9 Cables, GE Catalog Numbers, 4-3 Capabilities of DCU and DCM, l-l Change Password, 5-20, 5-31 Check Program Error Code, 5-20, 5-32 Clear Target Diagnostic Status Words, 5-20, 5-49 Commands, Series Six SCREQ, 5-2 06100, 06200 No Op 5-2 06101, 06201 Read from Target to Source Register Table, 5-2 06102, 06202 Read from Target to Source Input Table, 5-2 06103, 06203 Read from Target to Source Output Table, 5-2 06111, 06211 Write to Target from Source Register Table, 5-2 06112, 06212 Write to Target from Source Input Table, 5-2 06113, 06213 Write to Target from Source Output Table, 5-2 Command Numbers, 5-2 Command Target Run/Program mode, 5-20, 5-46 Communication Errors, 6-l 8 Communications Port Configuration DIP Switches (DCU), 2-6 Communications Port Configuration DIP Switches (DCM), 3-7 Communications Connector (DCU), 2-3 Communications Connector (DCM), 3-3

Configuration Switches Co&, 2-4 Configuration Switches (DCM), 3-4 Configuring the DCU Communications Port, 2-6 Configuring the DCM Communications Port, 3-7 Control Character Coding, 6-2 Data Flow Direction and Memory Type, 6-l 2 Data Length, 5-12 Data Rate Selection (DCU), 2-6 Data Rate Selection (DCM), 3-7 DCM Configuration Switches, 3-4 DCU Configuration SWitches, 2-4 DCU ID DIP Switches, 2-5 DCM ID DIP Switches, 3-6 DCU or DCM ID Number, 6-12 Description and Operation of User Interfaces (DCU), 2-1 Description and Operation of User Interfaces (DCM), 3-l Diagnostic Status Words, 5-16, 5-48, 5-49 Discrete I/O, 5-3, 6-13, Electrical Interface Circuits, 4-l ENQ, 6-2 Enquiry Response Delay, 6-2 EOT, 6-2 Error Checking for Series One Plus, 5-14, 5-15, 6-21 Error Codes, Diagnostic Status Word 1, 5-16 Error Codes, Series one, Series One Junior, Series Three, 5-16...19 ETB, 6-2 ETX, 6-2 External Power Supply Connector (DCM), 3-3 External Power Supply Connector (DCU), 2-7 Front Front

Panel Connectors Panel Connectors

(DCU), 2-3 (DCM), 3-3

Header and Text Data Block Response, 6-l 5 Header Block, 6-11

Page 129

GEK-90477

..

I-II

Index

INDEX

Installing the DCU, 2-9 Installing the DCM, 3-10 Invalid Data, 6-19 lnval id Header, 6-l 8 Invalid NAK, ACK, or EOT, 6-18 LED Indicators (DCU), 2-2 LED Indicators (DCM), 3-2 Limitations of Data Transfers for the Series One and Series One Junior, 5-l 2 Logging-In on the Series One Plus, 5-14, 5-20, 5-30, 6-20 Loop-Back Diagnostics, 4-12 Loop-Back Test Selection (DCU), 2-6 Loop-Back Test Selection (DCM), 3-7 Mapping Series One Junior References to Target Addresses, 5-6 Mapping Series One Plus References to Target Addresses, 5-7 Mapping Series One References to Target Addresses, 5-5 Mapping Series Three References to Target Addresses, 5-9 Master-Slave Normal Sequence Flow Charts, 6-6 Master-Slave Protocol, 6-l Mating Connector for the Communications Port, 4-2 Message Termination, 6-16 Message Transfers, 6-l 1 Modem Configuration Cable Diagrams, 4-8 Mul t idrop Configurations, l-3 NAK, 6-2 Normal Response, Slave, 6-5 Normal Sequence Protocol Format, 6-3 Normal Sequence, Master, 6-5 Normal Sequence, Master-Slave, 6-3 Number of Bytes in Incomplete Last Block, 6-l 4 Number of Complete Data Blocks to Follow Header, 6-14 On/Off On/Off On/Off On/Off

Line Line Line Line

Switch Switch Switch Switch

(DCU), 2-4, 2-10 (DCM), 3-4 (DCU), 2-4, 2-10 (DCM), 3-4

Parity Selection (DCU), 2-6* Parity Selection (DCM), 3-7 Password for Series One Plus, 5-14, 5-l 5, 6-20 Point-to-Point Configuration, l-2 Port Characteristics, 4-l Power Cycle Conditions CDCU), 2-10 Power Cycle Conditions (DCM), 3-l 1 Power Supply Select Switch (DCU), 2-7 Power Supply Select Switch (DCM), 3-8 Power-Up Diagnostics, 4-12 Power-Up Mode Selection (DCU), 2-6, 2-10 Programmer Connector (DCU), 2-3 Read Data Blocks, Master or Slave, 6-l 0 Read from Target Timers and Counters, 5-20, 5-21, 5-37 Read from Target Data Registers, 5-20, 5-26, 5-35 Read from Target I/O, 5-20, 5-22, 5-40 Read from Target User Memory, 5-20, 5-24, 5-42 Read PC Type, 5-20, 5-44 Read Target Diagnostic Status Words, 5-20, 5-49 Read Target Run/Program Mode, 5-20, 5-45 RS-422 Link Connector, 4-6 Scratch Pad, 5-4, 6-13, 6-19 SCREQ Command Examples, 5-20 Change Password, 5-20, 5-31 Check Program Error Code, 5-20, 5-32 Clear Target Diagnostic Status Words, 5-20, 5-49 Command Target Run/Program mode, 5-20, 5-46 Logging-In with the Password, 5-20, 5-30 Read from Target Timers and Counters, 5-20, 5-21, 5-37 Read PC Type, 5-20, 5-44 Read from Target Data Registers, 5-20, 5-26, 5-35 Read Target Diagnostic Status Words, 5-20, 5-48

Page 130

GEK-90477 l-iii index

INDEX

SCAEQ Command Examples (cont.) Read from Target I/O, 5-20, 5-22, 5-40 Read from Target Run/Program Mode, 5-20, 5-45 Read from Target User Memory, 5-20, 5-24, 5-42 Write to Target Data Registers, 5-20, 5-27, 5-36 Write to Target I/O, 5-20, 5-23, 5-41 Write to Target Timers and Counters, 5-20, 5-28, 5-38 Write to Target User Memory, 5-20, 5-25, 5-43 SCREQ Registers, 5-2 Serial Link Time Out, 6-16, 6-17 Series Three CPU Connector (DCM), 3-3 SOH, 6-2 Source ID Number, 6-14 Source Memory Address, 5-13 STX, 6-2 System Configurations, l-2 Test Diagnostics, 4-12 Text Data Block, 6-15 Timer/Counter Accumulators, 6-13 Target ID, 6-12

AUTOMATION

CONTROLS

OPERATIONS,

5-3,

GENERAL

Target Memory Address, 6-12, 5-3 Target Memory Type, 5-3 Terminating Resistors, 4-4 Timing Consideratons, 6-16 Turn-Around Delay Selection (DCU), 2-6 Turn-Around Delay Selection (DCM), 3-7 Turn-Around Delays, 6-16 Units of Load (Series One/Junior), 2-8 Units of Load (Series Three), 3-9 User Memory, 5-4, 6-13 Using the DCU with CPU Rack Power (DCU), 2-7 Using the DCM with CPU Rack Power (DCU), 3-8 Workmaster to DCU or DCM Cable Diagrams, 4-l 1 Write Data Blocks, Master or Slave, 6-10 Write to Target Data Registers,‘ 5-20, 5-27, 5-36 Write to Target I/O? 5-20, 5-23, 5-41 Write to Target Timers and Counters, 5-20, 5-28, 5-38 Write to Target User Memory, 5-20, 5-25, 5-43

ELECTRIC

COMPANY,

CHARLOTTESVILLE,

VIRGINIA;::

n.-!:

Page 131

This page is a scan with no text; see it in the PDF.

Page 132

This page is a scan with no text; see it in the PDF.

Page 133 read from a scan by OCR; it may hold reading errors

GE Fanuc Automation North America, Inc., Charlottesville, Virginia

Page 134 read from a scan by OCR; it may hold reading errors

GEK-90477A