Spec sheet · GfG Instrumentation
GfG Instrumentation 4021 Spec Sheet
Spec sheet2 pagesPDF 346 KB
Both pages are below, each with its text.
Covers · 1 model
The models it covers
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
This is a two-page GfG Instrumentation spec sheet for the RAM 4021 AutoCal series of continuous breathing air monitors. It covers the 4021, 4021-1, 4021-DPX and 4021-PR monitors and the 8025, 8050 and 8100 wall-mounted filter panels. It helps a buyer pick a model by the gases it measures and see its technical data.
- What it is
- Continuous carbon monoxide monitor for compressed breathing air p. 1
- CO sensor
- Electrochemical sensor, reading shown on an illuminated LCD p. 2
- Power
- 110 VAC or 12 VDC p. 2
- Relay contacts
- 1 alarm (red) NO/NC, 1 warning (yellow) NO/NC; 4021-PR adds 1 power loss NO/NC p. 2
- Dimensions
- Monitor only: 7.3x5.9x4 inches (185x150x101 mm) (HxWxD) p. 2
- Sample flow rate
- 0.5 cubic feet of air per hour (scfh) p. 2
- Variants
- 4021 (CO), 4021-1 (CO and O2), 4021-DPX (CO and dew point), 4021-PR (CO plus a power-loss relay) p. 2
- Optional sensors
- Oxygen or dew point p. 2
- Alarm features
- Alarm relay contacts, user adjustable alarm point, low flow alarm indicator p. 2
- Calibration
- AutoCal system p. 2
- Filter panels
- 8025 (25 CFM, 2 outlets), 8050 (50 CFM, 4 outlets), 8100 (100 CFM, 8 outlets), wall mounted p. 2
- Panel connections
- 1/2" FPT on 50 and 100 CFM panels; 3/8" FPT on 25 CFM panels p. 2
What this sheet walks you through
- Choosing a model by the gases it measures p. 2
- Choosing a wall-mounted filter panel p. 2
- OSHA carbon monoxide rules for breathing air compressors p. 2
Good to know
- The sheet states the monitors satisfy OSHA rule 29 CFR 1910.134 (d) (2) (ii) for carbon monoxide monitoring. p. 2
- Specifications may change without notice. p. 2
Questions this sheet answers
What gases does the RAM 4021 monitor?
Carbon monoxide, with optional oxygen or dew point sensors depending on the model. p. 2
What power does the GfG 4021 need?
110 VAC or 12 VDC. p. 2
What is the difference between the 4021 and the 4021-PR?
The 4021-PR adds a relay that signals power loss to the monitor; the sheet says it complies with the newest NFPA regulation. p. 2
How many air outlets do the GfG filter panels have?
The 8025 has two quick connect outlets, the 8050 four and the 8100 eight. p. 2
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
RAM 4021 AutoCal
Continuous Respirable Air Monitor
Continuous compressed air CO monitor
Integrated dew point measurement
Robust easy-to-operate design
Worldwide manufacturer of gas detection solutions
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
The Best Safeguard for Quality Breathing Air The RAM 4021 AutoCal® series is the unit of choice where specific and accurate measurement of carbon monoxide, oxygen or dew-point levels are required. Designed to meet OSHA requirements for monitoring of Grade D respirable air, this unit is equipped with a reliable electrochemical sensor that accurately indicates the level of carbon monoxide on an illuminated liquid crystal display. Adding versatility, this unit offers optional oxygen or dew point sensors for applications where detection or measurement is needed. Calibration and maintenance are simple with our innovative AutoCal® system. Additional features including alarm relay contacts, user adjustable alarm point, low flow alarm indicator and many more make this unit an intelligent choice. The RAM 4021 is available in four models, the 4021 (CO), 4021-1 (CO and O2), 4021-DPX (CO and dew point levels) and 4021-PR (CO and additional relay to signal power loss to monitor, complies with newest NFPA regulation). All models may
RAM 4021 series
be purchased with or without airline filter systems.
Respiratory air specifications All GfG Instrumentation RAM Instruments satisfy the requirements of OSHA rule 29 CFR 1910.134 (d) (2) (ii) for carbon monoxide monitoring. They will also monitor Grade E air, generally specified for breathing air in cylinders (SCBA). OSHA Regulations (Standard - 29 CFR) Respiratory Protection - 1910.134 (i) (6) For compressors that are not oil-lubricated, the employer shall ensure that carbon monoxide levels in the breathing air do not exceed 10 ppm. (i) (7) For oil-lubricated compressors, the employer shall use a high-temperature or carbon monoxide alarm, or both, to monitor carbon monoxide levels. If only high-temperature alarms are used, the air supply shall be monitored at intervals sufficient to prevent carbon monoxide in the breathing air from exceeding 10 ppm.
Wall mounted filter panel option 8025 (25 CFM), 8050 (50 CFM), and 8100 (100 CFM)
The 25, 50 and 100 CFM panels filter out dangerous toxins from supplied air sources and ensure clean, breathable air. The threestage filter system efficiently removes particulates, oil vapors and hydrocarbons from an air supply. After filtration, the regulator sets the pressure for the respiratory equipment and the manifold assembly provides multiple outlets for airline hose quick connections. The model 8025 panel includes two user female quick connect outlets; the 8050 includes four, and the 8100 includes eight. A 1/2" FPT connection is standard on all 50 and 100 CFM panels, and a 3/8" FPT connection is standard on all 25 CFM panels.
Technical DataGasesExpected sensor lifePower source
Carbon monoxide (CO) Oxygen (O2) Dew point
O2, CO Dew point
110 VAC or 12 VDC
32 to 105°F / 0 to 40°C
Detection ranges
Adjustable alarm points CO O2 Dew point
Dimensions (monitor only)
CO O2 4021-DPH 4021-DPL 4021-DPX
0-100 ppm 0-25% volume 10 to 70°F / -12 to 21°C -40 to 15°F / -40 to -9°C -112 to 68°F / -80 to 20°C
Detection principles (sensor) CO specific 4021-DPL / 4021-DPH 4021-DPX
Electrochemical cell Solid state hydro Thin film technology
Air temperature
Greater than 2 years Greater than 2 years
5 ppm CO and 10 ppm CO 19.5% and 23.5% volume 39°F / 4°C (L) 10°F / -12°C
LEDs Case mounted horn Two dry contacts
Airline input 1/8" feed 1/2" FPT 3/8"
Standard pressure 70 to 150 psi 50 to 100 CFM panels (wall mount) 25 CFM panels (wall mount)
+32 to +122°F / 0 to 50°C
Available relay contacts and ratings
Display
1 alarm (red) NO/NC 1 warning (yellow) NO/NC 1 power loss NO/NC (4021-PR only)
Digital LCD
7.3x5.9x4 inches (185x150x101 mm) (HxWxD)
Weight (monitor only)
Alarms Visual Audible Relays
Temperature range
5 pounds (226 kg)
Available models 4021 Carbon monoxide 4021-1 Carbon monoxide and oxygen 4021-DPL, 4021-DPH and 4021-DPX Carbon monoxide and dew point 4021-PR Carbon monoxide (complies with NFPA ’99 C-*26 (5.1.3.5-15))
Available filter panel options 8025 wall mounted 25 CFM panel (2 ports) 8050 wall mounted 50 CFM panel (4 ports) 8100 wall mounted 100 CFM panel (8 ports)
Sample flow rate 0.5 cubic feet of air per hour (scfh)
Specifications subject to change without notification
Distributed by:
- Tel: Fax: E-mail: Website
- (800) 959-0329 or (734) 769-0573 (734) 769-1888 info@gfg-inc.com www.gfg-inc.com
032708