Two GIC Thermodynamics catalog pages on 2-wire microprocessor head mount transmitters that convert a thermocouple or RTD (Pt100) sensor signal into a 4 to 20 mA loop current. They cover the MP82700 universal transmitter (rail-mount version MP88700), the MP82800 multi-input transmitter and the MP82850-R economy RTD transmitter, with their options and a specification table. The pages do not describe a Pt100 sensor itself.

Product type
2-wire microprocessor head mount transmitters for thermocouple and RTD (Pt100) sensors p. 1
Output
4 to 20 mA loop current on the same two wires that power the transmitter; electronics draw less than 4 mA p. 1
MP82700 inputs
MP82700: 12 thermocouples (J, K, E, T, R, S, B, C, D, N, L, U), 8 RTDs (PT100, PT500, PT1000, NI100, NI500, NI1000, CU10, CU100), millivolt, resistance p. 1
MP82700 features
MP82700: fully isolated, fully linearized, accuracy 0.1%, RFI/EMI immunity DC to 1GHz p. 1
MP82700 options
MP82700: D plug-in loop powered readout, IF interface and software, CW connection head with window, H Hart Protocol p. 1
Rail-mount version
MP82700 assembly in rail-mount form: part number MP88700 p. 1
MP82800 inputs
MP82800: thermocouple J, K, E, T, N and PT100 RTD p. 2
MP82850-R
MP82850-R: economy RTD transmitter, PT100 RTD only, push button programmable p. 2
Readout option (D)
Loop powered plug-in LCD readout that plugs on top of the transmitter to show the measured temperature p. 2
Software option (IF)
Interface and Point 'n Click software for Mp series transmitters, programmed from a PC p. 2
Head option (CW)
DAN connection head with window for head mount transmitters with display (D) p. 2

What this sheet walks you through

  • How a 2-wire transmitter carries power and signal on the same two wires p. 1
  • Choosing a head-mount or rail-mount transmitter p. 1
  • Choosing among the MP82700, MP82800 and MP82850-R p. 2
  • Transmitter options: readout, connection head and PC interface p. 2
  • Specification table for inputs, output, supply, drift and housing p. 2

Good to know

  • A rail-mount transmitter is used where extreme temperature or vibration rules out a head-mount one. p. 1
  • The 2-wire transmitter ideally sits in the sensor connection head for the best signal. p. 1

Questions this sheet answers

What sensors does the GIC MP82700 transmitter accept?

Thermocouples J, K, E, T, R, S, B, C, D, N, L, U; RTDs PT100, PT500, PT1000, NI100, NI500, NI1000, CU10, CU100; millivolt and resistance. p. 1

Is there a rail-mount version of the MP82700?

Yes. The rail-mount version of the assembly is ordered as part number MP88700. p. 1

Which GIC transmitter takes only a PT100 RTD?

The MP82850-R economy RTD transmitter is listed for PT100 RTD only and is push button programmable. p. 2

What output signal do these 2-wire transmitters give?

The current drawn from the supply varies from 4 to 20 mA in proportion to the sensor signal, on the same two wires as the power. p. 1

How is the MP82700 programmed?

With the Interface and Software (IF) option and a PC, in less than one minute. p. 1, 2

The file

Size and text

Pages2
PDF341 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of GIC Thermodynamics PT100 Spec Sheet

The text of page 1, from the PDF itself

Transmitters 2-Wire Microprocessor Head Mount Transmitters Basically, a transmitter is a signal conditioner. It accepts a low level input signal from a sensor, a millivolt signal from a thermocouple or a resistance signal from a RTD (Pt100), and provides an output signal that is directly proportional to the input-signal. Most transmitters provide a current output signal (generally 4-20 mA or 0-20 mA signal) rather than a voltage output. Conversion to a current signal virtually eliminates any interference from line noise and allows accurate transmission over relatively long distances using ordinary uncompensated copper wire.

2-Wire Transmitters

2-wire transmitters allow the same two wires to carry both the transmitter power and the transmitter signal. The transmitter electronics is designed to use less than 4 mA for internal consumption. As the input signal (from the

sensor) changes, the current drawn from the power supply will vary from 4 to 20 mA in direct proportion to the sensor change. This current change is referred to as the “loop current”. This 2-wire technique allows significant savings by reducing the size of the transmitter installation as well as a reduction of installation time and materials required while still providing accurate signal transmission. Ideally, the 2-Wire Transmitter should be placed in the sensor connection head to provide the best signal. A wide range of 2-Wire head-mount transmitters (in both isolated and non-isolated versions) to fit almost any standard connection head is offered. When a 2-Wire Head-Mount Transmitter cannot be used (because of extreme temperature or vibration) a complete line of 2-Wire Rail Mount Transmitters are available.

Universal Transmitter The MP82700 is one of the smallest and most advanced 2-wire head mounting microprocessor transmitter in the industry. With its small size it is able to fit in standard connection heads yet still provide the most advanced microprocessor available. Easily programmed in less than one minute the Mp82700 can be used for all your different sensor and range requirements. Standard Features:

  • Universal Input 12 T/C’s : J, K, E, T, R, S, B, C, D, N, L, U 8 RTD’s : PT100, PT500, PT1000, NI100, NI500, NI1000, CU10, CU100 Millivolt (V), Resistance (Ohms)
  • Fully Isolated
  • ATEX Approval
  • Fully Linearized
  • High Accuracy (0.1%)
  • Small Size
  • 5-year warranty
  • RFI/EMI Immunity (DC to 1GHz)

MP827001

1 Options
D = Plug-in Loop Powered Readout IF = Interface and Software CW = Connection Head with Window EX = Intrinsically Safe Approval FM = Intrinsically Safe Approval H = Hart Protocol

*Note: If you require a Rail-mount Version of this assembly, order as part number MP88700

64

2603 Parmenter Blvd., Royal Oak, Michigan 48073 • Phone (800) 876-4442 • Fax (248) 280-0998

Page 2 of GIC Thermodynamics PT100 Spec Sheet

The text of page 2, from the PDF itself

2-Wire Transmitters If you do not require all the features of the MP82700 there are other models to consider: RTD Transmitter

Multi-Input Transmitter

MP82800 T/C (J,K,E,T,N) RTD (PT100 RTD)

  • Fully Linearized
  • RFI Protected
  • ATEX Approval

MP82800

PT100 RTD (only)

  • Fully Linearized
  • RFI Protected
  • ATEX Approval
  • High Accuracy
  • Small Size
  • 5-Year Warranty 1
  • High Accuracy
  • Small Size
  • 5-Year Warranty

MP82800-R

1 Options
1
1 Options
D = Plug-in Loop Powered Readout IF = Interface and Software CW = Connection Head with Window EX = Intrinsically Safe Approval FM = Intrinsically Safe Approval

D = Plug-in Loop Powered Readout IF = Interface and Software CW = Connection Head with Window EX = Intrinsically Safe Approval

Economy RTD Transmitter PT100 RTD (only) MP82850-R

  • Fully Linearized
  • High Accuracy
  • Push Button Programable
  • 5-Year Warranty

1

1 Options
D = Plug-in Loop Powered Readout CW = Connection Head with Window

TRANSMITTER OPTIONS

Plug-in Loop Powered Readout (D) The “display” is a loop powered plug-in LCD Readout for local display of the measured temperature. Easy to connect on top of the transmitter with the interface connector. Connection Head with Window (CW) This specially designed DAN connection head is suitable for microprocessor head mount transmitters with display (D). The display will be attached by a connection cable with plugs - the same method as the Interface (IF) connection. Interface and Software (IF) The interface and “Point ‘n Click” software program is suitable for all microprocessor based transmitters (Mp series). Using your PC and the “point ‘n click” software transmitters are easily programmed in less than one minute.

Specifications Input RTD

Pt100, Pt500, Pt1000 Ni100, Ni500, Ni1000 Cu10, Cu100

Input T/C

K, J, L, T, U, E, R, S, B, C, D, N

Input V Input Ohm Minimum Span

See Table belowOutput4..20 mA or 20..4 mALinearizationOn / OffSupply *

10..40 VDC, Polarity Protected

Supply Effect0.001%/VMax. Ripple

10 V PP. Min Vbat=10 Vdc

Zero Drift

±0.01%/oC or ±0.02 oC/oC

Span Drift

±0.005%/oC or ±0.01 oC/oC

Long Term Drift±0.05%/YearCold Junction Drift±0.01 oC/oC

Excitation Current, RTD

0.1 mA

Sensor Lead Resistance, RTD

500 Ohm max.

Sensor Lead Resistance Effect

0.001 oC/Ohm

Intrinsically Safe Approval (EX)

Sensor Lead Resistance, T/C

10,000 Ohm max.

Intrinsically Safe Approval (FM)

Open Circuit DetectionUpscale / DownscaleLoad CapacityVbat-10V / 20 mAResponse Time≤ 3 sec.Startup Time20 sec.Warm-up Time5 min.Isolation500 VCD

Ambient Operating Temp.

-40...+85oCStorage Temperature-40...+100oCIngress ProtectionIP30Housing Material

Zinc Alloy (ZAMAK 5) epoxy coated

Housing Dimension

43mm Dia. x 27mm H.

GIC offers a large variety of transmitters for every need. For the latest transmitter options and indepth specifications see our website

www.GICThermodynamics.com

Web: http://www.gicthermodynamics.com • Email: sales@gicthermodynamics.com