Manual · GIC Thermodynamics
Instruction Manual R82000, T82000, P82000, P82000 FR (including ATEX & HF)
Manual7 pagesPDF 419 KB
Instruction manual for the S-Products 82000 series 2-wire 4-20 mA transmitters for Pt100 RTD, thermocouple and potentiometer inputs.
What this file really is
The old site listed this file as a manual for the GIC Thermodynamics PT100. This is the S-Products instruction manual for its 82000 series transmitters (the R82000 takes a Pt100 input); it does not name GIC Thermodynamics.
Filed with · 1 model
Also filed with these models on the old site
Summary
What is in it
S-Products' instruction manual for the 82000 series of free-to-scale 2-wire transmitters: the R82000 for Pt100 RTDs, the T82000 for type K and J thermocouples, and the P82000 and P82000 FR for potentiometers or variable resistors. It gives specifications, the ATEX intrinsically safe version with its marking and Zener barrier parameters, installation requirements, connection diagrams, range selection with solder links, programming and calibration steps, dimensions, mounting in a connection head and warranty.
Its parts
- Specifications
- ATEX
- Connections
- Introduction
- Programming and Calibration Instructions
- Dimensions
- Warranty
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
S-Products instruction manual (issue 031105) for the 82000 series 2-wire transmitters: R82000 for RTD (Pt100) sensors, T82000 for thermocouples, and P82000 and P82000 FR for potentiometers. The manual states that it includes ATEX and HF versions; it gives specifications, Zener barrier connection data, wiring, span selection and calibration steps, and mounting in a connection head. It does not describe a Pt100 sensor itself.
- Product type
- Free to scale 2-wire transmitters: R82000 RTD (Pt100), T82000 thermocouple, P82000 FR potentiometer, P82000 variable resistor p. 2
- Output and supply
- 4-20 mA output; 12-36 VDC power supply p. 2
- Range setting
- Solder link on top of the unit, with fine zero and span adjustment by 20-turn potentiometers p. 2
- R82000 input
- R82000: Pt100 (alpha=0.00385), linearized; zero between -50° and +50°C; lead resistance effect 0.01°C/Ohm, max. 500 Ohm p. 2
- T82000 spans
- T82000: type K 150° to 1200°C, type J 150° to 600°C; output voltage linear p. 2
- P82000 FR input
- P82000 FR: potentiometer of 1 kiloOhm to 50 kiloOhm; 0...100% = 4...20 mA fixed range p. 2, 5
- Terminals
- Supply on KL1, KL2; sensor input on KL3, KL4, KL5 p. 3, 5
- Drift
- Zero drift ±0.02%/°C; span drift ±0.02%/°C p. 2
- Open circuit
- Output goes upscale above 23 mA, limited to 40 mA p. 2
- Load
- (Vbat-12V) / 20 mA p. 2
- Temperature
- Ambient -20° to 80°C (-4° to 160°F); storage -20° to 100°C p. 2
- Protection
- IP20 for all 82000 series transmitters p. 4
- Calibration tool
- 24V supply with mA indicator (Model TL245 recommended) and an input simulator p. 6
- Discontinued versions
- R83000 and T83000 were the factory calibrated versions of R82000 and T82000 p. 2
What this manual walks you through
- Selecting the span with the solder link p. 5, 6
- Calibrating the R82000 and T82000 zero and span p. 6
- Calibrating the P82000 FR with a potentiometer p. 6
- Wiring power, sensor, potentiometer or variable resistor p. 5
- Zener barrier connection limits p. 3
- Wiring with shielded cable for noise immunity p. 4
- Mounting the transmitter in a connection head p. 7
Good to know
- The manual states that ATEX approved units may only be connected to a Zener barrier. p. 4
- With IP20 protection the transmitters need a dry, clean and well controlled environment. p. 4
- The manual states that ATEX approved units may have different power requirements. p. 2
- The span is the full range: -50° to +150° needs a span of 200°, not 150°. p. 6
- Do not open the transmitters; return a faulty unit to the supplier. p. 7
Questions this manual answers
What supply voltage does the R82000 transmitter need?
12-36 VDC; the specifications are given at 24VDC. p. 2
How do I calibrate an R82000 or T82000?
Solder the span link from table 1, connect a 24 V DC supply, milliammeter and input simulator, then set 4 mA with ZERO and 20 mA with SPAN, repeating until correct. p. 6
What potentiometer can the P82000 FR take?
A potentiometer of at least 1 kiloOhm and at most 50 kiloOhm. p. 5
What does the transmitter output if the sensor circuit opens?
Open circuit detection drives the output upscale, above 23 mA and limited to 40 mA. p. 2
What thermocouple ranges does the T82000 cover?
Type K spans of 150° to 1200°C and type J spans of 150° to 600°C. p. 2