Page 247
D.2 - Input Resolver Module (2, 4 channel) Introduction
The input resolver module can interface to two or four independent resolvers (or equivalent transducers). Information from the resolvers is used to update two or four separate position counters and latches within the module. For each channel, the module sends out two sine waves 90° out of phase with each other and receives a signal whose phase represents the angular position of the resolver. This input signal is used to update a 24-bit counter. This module can be programmed to "latch" (store) the counter value when a signal is received by the fast input for that channel. An LED in the upper section of the module goes on when the fast input for each channel is energized. The DIAG LED goes on briefly while the diagnostic tests are running. Figure D2-1. INPUT RESOLVER module (4 CH)
INPUT RESOLVER
Name of module Diagnostic LED
DIAG
IN1
Indicator LEDs for fast inputs
IN2 IN3 IN4
1 3 5 7 9 11 13 15
Screw terminal connector
17 19 21 23 25 27 29 31 33 35 37 39
Door
AA83-1790
D.2 -1
Page 248
Input Resolver Module (2, 4 channel)
Connections
All signals to the resolver module must come to its screw terminal connector through shielded twisted pair wires. These wires must be protected against electrical noise because of the speed and/or voltage levels of the signals transmitted through them. See the discussion in the Hardware chapter on "Preventing electrical noise in data lines". Each input resolver channel has four signal pairs, each of which has two screw terminal connections. The signals are: RPO output QPO output FDBK input 24 VDC fast input In addition the module has eight screw connections for terminating the shields. All eight are connected inside the module so they are the same point electrically.
IMPORTANT If the 24 VDC fast input is used, its power supply common must be connected to the SPG. Figure D2-2 shows the assignments for all the screw terminal connections on the module. To make the diagram more readable, The shielded twisted pair wires are shown with transparent shields. • Channel 3 shows how a potentiometer can be wired to the module. • The shielded twisted pair wires are shown grounded only for channel 4. In an actual application, every cable shield must be grounded. • The fast inputs for channels 1 and 2 are shown in source configuration; that for channel 4 is shown in sink configuration. •
D.2 -2
Page 249
Input Resolver Module (2, 4 channel)
Figure D2-2. Connections for the Input Resolver Terminals
FDBK
1
FDBK (R1) FDBK (R2) FDBK (S1) RPO RESOLVER (S3) RPO (S2) QPO (S4) QPO
RPO
QPO
COLOR KEY R1 RED/WHITE R2 YELLOW/WHITE S1 RED S3 BLACK S2 YELLOW S4 BLUE
3
RPO
CHANNEL
1 5
QPO FDBK
7
FDBK
(R1) FDBK (R2) FDBK (S1) RPO RESOLVER (S3) RPO (S2) QPO
RPO
9
RPO
(S4) QPO
QPO
CHANNEL
2 11
QPO FDBK
13
RPO
15
QPO
17
FDBK
19
POTENTIOMETER MIN
CHANNEL
3
MAX
FDBK (R1) FDBK (R2) FDBK (S1) RPO RESOLVER (S3) RPO (S2) QPO (S4) QPO
RPO
21
RPO QPO
CHANNEL
4 23
QPO SHIELD
25
SHIELD SHIELD
27
SHIELD
24 VDC POWER SUPPLY 0V TO SPG
24 V
SHIELD
29
SHIELD FAST INPUT SWITCHES
SHIELD
31
SHIELD FAST INPUT
33
CHANNEL
35
CHANNEL
FAST INPUT FAST INPUT
1 2
FAST INPUT
37
CHANNEL
3 FAST INPUT FAST INPUT
39
CHANNEL
4
D.2 -3
Page 250
Input Resolver Module (2, 4 channel)
IMPORTANT If a channel is not being used, tie its FDBK input to its RPO output to ensure proper operation. See Figure D2-3. Figure D2-3. Unused Channel Connection
FDBK (R1) FDBK (R2) FDBK (S1) RPO RESOLVER (S3) RPO (S2) QPO (S4) QPO
1
FDBK RPO
3
RPO QPO
1 5
QPO FDBK
CHANNEL
7
Connect FDBK to RPO on any unused channel.
FDBK RPO
9
RPO QPO
11
CHANNEL
2
QPO
AA1118-3292
Resolvers
A resolver (Figure D2-4) is a servo feedback device which provides absolute position over one electrical revolution. It receives RPO (reference phase output) and QPO (quadrature phase output) signals from the interface module. RPO and QPO signals are sine waves 90° out of phase with each other. They energize two stator coils positioned at 90° to each other. The stator coils induce a sine wave signal called FDBK (feedback) in the rotor coil. The phase of this signal, with respect to RPO, depends on the rotor coil's position.
D.2 -4
Page 251
Input Resolver Module (2, 4 channel)
R2
R1
Figure D2-4. Diagram of a Resolver
QPO ck ba ed Fe
S2 S4
RPO
S1
S3 AA85-1790
The recommended resolver has a part number in the specification sheet at the end of this section. Other resolvers may be used, if they conform to the interface module specifications. Theory of Operation
The module sends out two sine wave signals, RPO and QPO. These signals have the same voltage amplitude and frequency but are 90° out of phase. The module then receives a FDBK sine wave signal whose phase is a measure of the angular rotation of the resolver. The phase information is used to increment or decrement an internal 24-bit up/ down counter. A phase shift of 360° corresponds to 4,000 counts of resolution, so one count represents 5.4 arc-minutes of rotation of the resolver. The value in the counter thus represents the current position of the resolver. In addition to the counter, there is a 24-bit latch associated with each resolver interface. This module can be programmed so that the counter value is latched or stored when a fast 24 VDC input pulse is received for that channel. Each of the four 24-bit latches has a fast 24 VDC input associated with it. Each input is optically isolated. This input is typically used for referencing or synchronization purposes. Fast input characteristics include: The detection of a signal occurs faster than it does for the DC inputs in other modules, due to less filtering. Because of this there is also less noise immunity. • The response to a fast input signal is independent of ladder scan time. The module can be programmed to latch a position count as soon as this input is detected. •
D.2 -5
Page 252
Input Resolver Module (2, 4 channel)
Specification Table
Characteristic
Input Resolver module specifications
Function
Measures the position of a transducer that accepts a 2phase quadrature excitation, such as a resolver or potentiometer
Part number
4 ch 502-03552-02
Field side connector
40 pin card edge connector, screw terminals
Excitation method
2-phase quadrature for control transformer type of resolver
Excitation frequency
2 ch 502-03552-22
2 KHz
RPO and QPO outputs Output voltage Current per output channel, max. Resolver transformer ratio
16 VP-P (5.7 VRMS) 4ch 5 mA RMS (14 mA p-p) 2ch 10mARMS (20 mA p-p)
.5 to 1.0
Resolution, resolver
4000 Feedback Units (FUs) per electrical revolution
Resolution, potentiometer
1000 Feedback Units (FUs) per electrical revolution
Accuracy at constant temperature
± 20 arc minutes
Accuracy over temperature range ± 45 arc minutes Electrical velocity, max.
15000 RPM (1M FU/Sec.)
Cable length, max.
200 ft.
Stored position value range
24-bit up/down counter 24-bit latch
Fast input
Nominal 24 VDC
Reverse polarity protection
YES
Voltage max.
30 VDC
Guaranteed on
15 VDC
Guaranteed off
5 VDC
Input impedance
2.7 K
On/off time, max.
50 µs
Indicator lights, fast inputs
LED is lit when current flows into the input.
Indicator light, module
D.2 -6
DIAG LED goes off when the module passes its diagnostic tests
Page 253
Input Resolver Module (2, 4 channel)
Logic side power requirements (typical for 4 ch)
473 mA @ 5V 133 mA @+15V 20 mA @-15V 14 mA per energized input @ +15V 14 mA per energized input @ -15V 12 mA per fast input
Logic side power requirements (typical for 2 ch)
296 mA @ 5V 105 mA @ +15V 16 mA @ -15V 14 mA per energized input @ +15V 14 mA per energized input @ -15V 13 mA per fast input
Field side power dissipation, worst case
4 ch
1.4 W
2 ch
.7W
Recommended resolver
Giddings & Lewis part number 501-98409-00 Harowe 11BRW 300-F-1/10
Other suggested resolvers
Clifton 11BHW-0IE/A004 Kearfott CR41095050
Operating temperature range
7° C to 55° C (45° F to 131° F)
Storage temperature range
-40° C to 85° C (-40° F to 185° F)
Humidity
5 to 95%, non-condensing
CE Marked
Conforms to Directives 73/23/EEC, 89/336/EEC, 92/ 31/EEC, 93/68/EEC by conforming to the following standards: EN 50081-2:1993 EMC Generic Industrial Emissions EN 50082-2:1995 EMC Generic Industrial Immunity EN 61131-2:1994/A11:1996 Low voltage directive requirements for programmable controllers Operates with emissions below EN55011/ CISPR 11 Class A limits Immune to: • Electrostatic discharge (4K V contact mode, 8K V air discharge) per EN61000-4-2 • RF electromagnetic fields per EN61000-4-3, ENV 50141, and ENV50204 • Electrical fast transients per EN61000-4-4 • Magnetic fields per EN61000-4-8 Refer to the EMC Guidelines for more information. D.2 -7
Page 254
Input Resolver Module (2, 4 channel)
UL and C/UL Listed
File No. E126417 NRAQ Programmable Controllers
Physical size
1.6" wide x 12" high x 8.4" deep (including latch) 41 mm x 305 mm x 213 mm
Vibration (per IEC 68-2-6)
10-57 Hz (constant amplitude .15 mm) 57 - 2000 Hz (acceleration 2 g)
Shock (per IEC 68-2-27)
D.2 -8
Four shocks per axis (15g/11 msec)