D.3 - Input Multi-Channel Resolver Module (12 channel) Introduction
The input multi-channel resolver module can interface to 12 independent resolvers (or equivalent transducers). Feedback information from the resolvers is used to update the on-board memory. The position of each resolver can be read at any time by the PiC900. For each channel, the module sends out two sine waves 90° out of phase with each other and receives a signal whose phase represents the angular position of the resolver. The resolution of the angular position is 4000 counts per revolution or 0.09 degrees. The DIAG LED goes on briefly while the diagnostic tests are running. Figure D3-1. INPUT RESOLVER (Multi-Channel) Module (12 CH)
INPUT RESOLVER
Name of module Diagnostic LED
DIAG
1 3 5 7 9 11 13 15
Screw terminal connector
17 19 21 23 25 27 29 31 33 35 37 39
Door
AA1094-1292
D.3 -1
Page 256
Input Multi-Channel Resolver Module (12 channel)
Figure D3-2. Connections for the Input Resolver Terminals
CONNECTIONS
SCREW TERMINALS
CONNECTIONS RPO2
RPO1
1 RPO2 / QPO2
Up to 6 resolvers
RPO1 / QPO1
3 QPO2
QPO1
5 SHIELD
FDBK1
7 SHIELD
9 FDBK1 SHIELD SHIELD
11 FDBK2
FDBK3
13 FDBK2
FDBK3
15 SHIELD
FDBK5
17 FDBK4
FDBK5
19 FDBK4
SHIELD
21 FDBK6
FDBK7
23 FDBK6
FDBK7
25 SHIELD
FDBK9
27 FDBK8
29 FDBK9 FDBK8 SHIELD
31 FDBK10
FDBK11
33 FDBK10
FDBK11
35 FDBK12
SHIELD
37 FDBK12
SHIELD
D.3 -2
39
Up to 6 resolvers
Page 257
Input Multi-Channel Resolver Module (12 channel)
Connections
Figure D3-2 shows the screw terminal connections for the multi-channel resolver module. To connect 12 resolvers to the multi-channel resolver module, two user-supplied external terminal blocks must be used - one for each group of six resolvers as shown in Figure D3-3. (See Figure D3-4 for detail wiring of one resolver.) Figure D3-3. Using Terminal Blocks to Connect 12 Resolvers Multi-channel Resolver Module INPUT RESOLVER
DIAG
Terminal Block RPO/QPO Resolver 1
Resolver 2
Resolver 3
Terminal Block RPO/QPO Resolver 7
Resolver 8
Resolver 9
Resolver 4
Resolver 10
Resolver 5
Resolver 11
Resolver 6
Resolver 12
AA1142-4292
Each resolver has three signal pairs. The signals and where they are connected are listed below. All signals from the resolvers must come to the screw terminal connectors (either on the multi-channel resolver or on the terminal block) through shielded twisted pair wires. These wires must be protected against electrical noise because of the speed and/or voltage levels of the signals transmitted through them.
D.3 -3
Page 258
Input Multi-Channel Resolver Module (12 channel)
The maximum length of the twisted pair wire from the resolver to the terminal block is 100 feet. Signal pair from resolver
Connection
RPO and /shield
To terminal block
QPO and /shield
To terminal block
FDBK and /shield
To multi-channel resolver
The feedback from each resolver is brought back to the appropriate feedback channel connections on the multi-channel resolver module. The module has nine screw connections for terminating the feedback shields. All are connected inside the module so they are the same point electrically. If you are using more than nine resolvers, some of the feedback shields will have to be doubled up on the shield connections. The shields from the RPO and QPO signals are terminated on shield screw connections on the terminal block. The shield at the device end of the cable is not connected. Figure D3-4 shows how to wire a terminal block and the first resolver. The RPO, QPO, and outputs from the module are each connected to the terminal block. Each is then jumpered so that there are six signals of each type available for the six resolvers (RPO1, RPO2,... QPO1, QPO2,... , ,... etc.). 18 AWG wire is recommended for these connections. The maximum wire length between the multi-channel resolver module and the terminal block is 6 feet. The feedback signal from the resolver and its shield are wired directly to the module, not the terminal block.
D.3 -4
Page 259
Input Multi-Channel Resolver Module (12 channel)
Figure D3-3. Connecting Resolver to Terminal Block to Module
External Terminal Block FDBK
(use to connect up to six resolvers)
Resolver Module Screw Terminals RPO2
FDBK (R1) FDBK (R2) FDBK (S1) RPO Resolver (S3) RPO 1 (S2) QPO (S4) QPO
RPO RPO
RPO1
RPO1
1 RPO2 / QPO2
RPO2 RPO1 / QPO1
QPO
3
RPO3
QPO2
QPO RPO4 COLOR KEY
RPO5
R1 RED/WHITE R2 YELLOW/WHITE S1 RED S3 BLACK S2 YELLOW S4 BLUE
RPO6
QPO1
5 SHIELD
FDBK1
7
FDBK1
9
SHIELD
11
SHIELD
RPO1/QPO1 RPO2/QPO2
SHIELD RPO3/QPO3
Make appropriate connections for remaining resolvers
RPO4/QPO4
FDBK2
RPO5/QPO5
FDBK3
13 FDBK2
RPO6/QPO6
Resolver 2
QPO1
FDBK3
15
FDBK5
17
FDBK5
19
SHIELD QPO2 QPO3
FDBK4
QPO4
Resolver 3
FDBK4
QPO5 SHIELD
QPO6
21 FDBK6
SHIELD SHIELD SHIELD SHIELD
Resolver 4
SHIELD
FDBK7
23 FDBK6
SHIELD SHIELD
FDBK7
25 SHIELD
SHIELD
SHIELD
SHIELD
SHIELD
SHIELD
FDBK9
27 FDBK8
FDBK9
29 FDBK8
Resolver 5
SHIELD
31 FDBK10
FDBK11
33
FDBK11
35
FDBK10
FDBK12
Resolver 6
SHIELD
37
SHIELD
39
FDBK12
D.3 -5
Page 260
Input Multi-Channel Resolver Module (12 channel)
Resolvers
A resolver (Figure D3-5) is a servo feedback device which provides absolute position over one electrical revolution. It receives RPO (reference phase output) and QPO (quadrature phase output) signals from the interface module. RPO and QPO signals are sine waves 90° out of phase with each other. They energize two stator coils positioned at 90° to each other. The stator coils induce a sine wave signal called FDBK (feedback) in the rotor coil. The phase of this signal, with respect to RPO, depends on the rotor coil's position.
R2
R1
Figure D3-4. Diagram of a Resolver
QPO ck ba ed Fe
S2 S4
RPO
S1
S3 AA85-1790
The recommended resolver has a part number in the specification sheet at the end of this section. Other resolvers may be used if they conform to the interface module specifications. Theory of Operation
The module sends out two sine wave signals, RPO and QPO. These signals have the same voltage amplitude and frequency but are 90° out of phase. The module then receives a FDBK sine wave signal whose phase is a measure of the angular rotation of the resolver. A phase shift of 360° corresponds to 4,000 counts of resolution, so one count represents 5.4 arc-minutes of rotation of the resolver. The value in the on-board memory represents the current position of the resolver. The on-board memory position is updated every 3.0 msec for each of the 12 resolvers. There is a loss of feedback indicator for each resolver.
D.3 -6
Page 261
Input Multi-Channel Resolver Module (12 channel)
Specification Table
Characteristic
Input Resolver (12 ch) ModuleSpecifications
Function
Measures the position of a transducer that accepts a 2phase quadrature excitation, such as a resolver or potentiometer
Part number
502-03722-02
Field side connector
40 pin card edge connector, screw terminals
Excitation method
2-phase quadrature for control transformer type of resolver
Excitation frequency
4KHz
RPO and QPO outputs Output voltage
15 VP-P (5.3VRMS)
Current per output channel, max.
100 mA
Resolver transformer ratio
.5 to 1.0
Resolution, resolver
4000 Feedback Units (FUs) per electrical revolution
Resolution, potentiometer
1000 Feedback Units (FUs) per electrical revolution
Accuracy at constant temperature ± 12 arc minutes Accuracy over temperature range ± 5.4 arc minutes /10˚F Velocity, max.
15000 electrical RPM (1M FU/Sec.)
Cable length, max.
6 ft. from module to terminal block (18 AWG) 100 ft. from terminal block to resolvers (twisted pair)
Stored position value range
0-3999
Indicator light, module
DIAG LED goes off when the module passes its power-on diagnostic tests
Logic side power requirements (typical)
200 mA @ +5V 60 mA @ +15V 60 mA @ -15V
Recommended resolver
Giddings & Lewis part number 501-98409-00 Harowe 11BRW 300-F-1/10
Other suggested resolvers
Clifton 11BHW-0IE/A004 Kearfott CR410959
Operating temperature range
7° C to 55° C (45° F to 131° F)
Storage temperature range
-40° C to 85° C (-40° F to 185° F)
D.3 -7
Page 262
Input Multi-Channel Resolver Module (12 channel)
Humidity
5 to 95%, non-condensing
CE Marked
Conforms to Directives 73/23/EEC, 89/336/EEC, 92/ 31/EEC, 93/68/EEC by conforming to the following standards: EN 50081-2:1993 EMC Generic Industrial Emissions EN 50082-2:1995 EMC Generic Industrial Immunity EN 61131-2:1994/A11:1996 Low voltage directive requirements for programmable controllers Operates with emissions below EN55011/ CISPR 11 Class A limits Immune to: • Electrostatic discharge (4K V contact mode, 8K V air discharge) per EN61000-4-2 • RF electromagnetic fields per EN61000-4-3, ENV 50141, and ENV50204 • Electrical fast transients per EN61000-4-4 • Magnetic fields per EN61000-4-8 Refer to the EMC Guidelines for more information.
UL and C/UL Listed
File No. E126417 NRAQ Programmable Controllers
Physical size
1.6" wide x 12" high x 8.4" deep (including latch) 41 mm x 305 mm x 213 mm
Vibration (per IEC 68-2-6)
10-57 Hz (constant amplitude .15 mm) 57 - 2000 Hz (acceleration 2 g)
Shock (per IEC 68-2-27)
D.3 -8
Four shocks per axis (15g/11 msec)