Page 255

D.3 - Input Multi-Channel Resolver Module (12 channel) Introduction

The input multi-channel resolver module can interface to 12 independent resolvers (or equivalent transducers). Feedback information from the resolvers is used to update the on-board memory. The position of each resolver can be read at any time by the PiC900. For each channel, the module sends out two sine waves 90° out of phase with each other and receives a signal whose phase represents the angular position of the resolver. The resolution of the angular position is 4000 counts per revolution or 0.09 degrees. The DIAG LED goes on briefly while the diagnostic tests are running. Figure D3-1. INPUT RESOLVER (Multi-Channel) Module (12 CH)

INPUT RESOLVER

Name of module Diagnostic LED

DIAG

1 3 5 7 9 11 13 15

Screw terminal connector

17 19 21 23 25 27 29 31 33 35 37 39

Door

AA1094-1292

D.3 -1

Page 256

Input Multi-Channel Resolver Module (12 channel)

Figure D3-2. Connections for the Input Resolver Terminals

CONNECTIONS

SCREW TERMINALS

CONNECTIONS RPO2

RPO1

1 RPO2 / QPO2

Up to 6 resolvers

RPO1 / QPO1

3 QPO2

QPO1

5 SHIELD

FDBK1

7 SHIELD

9 FDBK1 SHIELD SHIELD

11 FDBK2

FDBK3

13 FDBK2

FDBK3

15 SHIELD

FDBK5

17 FDBK4

FDBK5

19 FDBK4

SHIELD

21 FDBK6

FDBK7

23 FDBK6

FDBK7

25 SHIELD

FDBK9

27 FDBK8

29 FDBK9 FDBK8 SHIELD

31 FDBK10

FDBK11

33 FDBK10

FDBK11

35 FDBK12

SHIELD

37 FDBK12

SHIELD

D.3 -2

39

Up to 6 resolvers

Page 257

Input Multi-Channel Resolver Module (12 channel)

Connections

Figure D3-2 shows the screw terminal connections for the multi-channel resolver module. To connect 12 resolvers to the multi-channel resolver module, two user-supplied external terminal blocks must be used - one for each group of six resolvers as shown in Figure D3-3. (See Figure D3-4 for detail wiring of one resolver.) Figure D3-3. Using Terminal Blocks to Connect 12 Resolvers Multi-channel Resolver Module INPUT RESOLVER

DIAG

Terminal Block RPO/QPO Resolver 1

Resolver 2

Resolver 3

Terminal Block RPO/QPO Resolver 7

Resolver 8

Resolver 9

Resolver 4

Resolver 10

Resolver 5

Resolver 11

Resolver 6

Resolver 12

AA1142-4292

Each resolver has three signal pairs. The signals and where they are connected are listed below. All signals from the resolvers must come to the screw terminal connectors (either on the multi-channel resolver or on the terminal block) through shielded twisted pair wires. These wires must be protected against electrical noise because of the speed and/or voltage levels of the signals transmitted through them.

D.3 -3

Page 258

Input Multi-Channel Resolver Module (12 channel)

The maximum length of the twisted pair wire from the resolver to the terminal block is 100 feet. Signal pair from resolver

Connection

RPO and /shield

To terminal block

QPO and /shield

To terminal block

FDBK and /shield

To multi-channel resolver

The feedback from each resolver is brought back to the appropriate feedback channel connections on the multi-channel resolver module. The module has nine screw connections for terminating the feedback shields. All are connected inside the module so they are the same point electrically. If you are using more than nine resolvers, some of the feedback shields will have to be doubled up on the shield connections. The shields from the RPO and QPO signals are terminated on shield screw connections on the terminal block. The shield at the device end of the cable is not connected. Figure D3-4 shows how to wire a terminal block and the first resolver. The RPO, QPO, and outputs from the module are each connected to the terminal block. Each is then jumpered so that there are six signals of each type available for the six resolvers (RPO1, RPO2,... QPO1, QPO2,... , ,... etc.). 18 AWG wire is recommended for these connections. The maximum wire length between the multi-channel resolver module and the terminal block is 6 feet. The feedback signal from the resolver and its shield are wired directly to the module, not the terminal block.

D.3 -4

Page 259

Input Multi-Channel Resolver Module (12 channel)

Figure D3-3. Connecting Resolver to Terminal Block to Module

External Terminal Block FDBK

(use to connect up to six resolvers)

Resolver Module Screw Terminals RPO2

FDBK (R1) FDBK (R2) FDBK (S1) RPO Resolver (S3) RPO 1 (S2) QPO (S4) QPO

RPO RPO

RPO1

RPO1

1 RPO2 / QPO2

RPO2 RPO1 / QPO1

QPO

3

RPO3

QPO2

QPO RPO4 COLOR KEY

RPO5

R1 RED/WHITE R2 YELLOW/WHITE S1 RED S3 BLACK S2 YELLOW S4 BLUE

RPO6

QPO1

5 SHIELD

FDBK1

7

FDBK1

9

SHIELD

11

SHIELD

RPO1/QPO1 RPO2/QPO2

SHIELD RPO3/QPO3

Make appropriate connections for remaining resolvers

RPO4/QPO4

FDBK2

RPO5/QPO5

FDBK3

13 FDBK2

RPO6/QPO6

Resolver 2

QPO1

FDBK3

15

FDBK5

17

FDBK5

19

SHIELD QPO2 QPO3

FDBK4

QPO4

Resolver 3

FDBK4

QPO5 SHIELD

QPO6

21 FDBK6

SHIELD SHIELD SHIELD SHIELD

Resolver 4

SHIELD

FDBK7

23 FDBK6

SHIELD SHIELD

FDBK7

25 SHIELD

SHIELD

SHIELD

SHIELD

SHIELD

SHIELD

FDBK9

27 FDBK8

FDBK9

29 FDBK8

Resolver 5

SHIELD

31 FDBK10

FDBK11

33

FDBK11

35

FDBK10

FDBK12

Resolver 6

SHIELD

37

SHIELD

39

FDBK12

D.3 -5

Page 260

Input Multi-Channel Resolver Module (12 channel)

Resolvers

A resolver (Figure D3-5) is a servo feedback device which provides absolute position over one electrical revolution. It receives RPO (reference phase output) and QPO (quadrature phase output) signals from the interface module. RPO and QPO signals are sine waves 90° out of phase with each other. They energize two stator coils positioned at 90° to each other. The stator coils induce a sine wave signal called FDBK (feedback) in the rotor coil. The phase of this signal, with respect to RPO, depends on the rotor coil's position.

R2

R1

Figure D3-4. Diagram of a Resolver

QPO ck ba ed Fe

S2 S4

RPO

S1

S3 AA85-1790

The recommended resolver has a part number in the specification sheet at the end of this section. Other resolvers may be used if they conform to the interface module specifications. Theory of Operation

The module sends out two sine wave signals, RPO and QPO. These signals have the same voltage amplitude and frequency but are 90° out of phase. The module then receives a FDBK sine wave signal whose phase is a measure of the angular rotation of the resolver. A phase shift of 360° corresponds to 4,000 counts of resolution, so one count represents 5.4 arc-minutes of rotation of the resolver. The value in the on-board memory represents the current position of the resolver. The on-board memory position is updated every 3.0 msec for each of the 12 resolvers. There is a loss of feedback indicator for each resolver.

D.3 -6

Page 261

Input Multi-Channel Resolver Module (12 channel)

Specification Table

Characteristic

Input Resolver (12 ch) ModuleSpecifications

Function

Measures the position of a transducer that accepts a 2phase quadrature excitation, such as a resolver or potentiometer

Part number

502-03722-02

Field side connector

40 pin card edge connector, screw terminals

Excitation method

2-phase quadrature for control transformer type of resolver

Excitation frequency

4KHz

RPO and QPO outputs Output voltage

15 VP-P (5.3VRMS)

Current per output channel, max.

100 mA

Resolver transformer ratio

.5 to 1.0

Resolution, resolver

4000 Feedback Units (FUs) per electrical revolution

Resolution, potentiometer

1000 Feedback Units (FUs) per electrical revolution

Accuracy at constant temperature ± 12 arc minutes Accuracy over temperature range ± 5.4 arc minutes /10˚F Velocity, max.

15000 electrical RPM (1M FU/Sec.)

Cable length, max.

6 ft. from module to terminal block (18 AWG) 100 ft. from terminal block to resolvers (twisted pair)

Stored position value range

0-3999

Indicator light, module

DIAG LED goes off when the module passes its power-on diagnostic tests

Logic side power requirements (typical)

200 mA @ +5V 60 mA @ +15V 60 mA @ -15V

Recommended resolver

Giddings & Lewis part number 501-98409-00 Harowe 11BRW 300-F-1/10

Other suggested resolvers

Clifton 11BHW-0IE/A004 Kearfott CR410959

Operating temperature range

7° C to 55° C (45° F to 131° F)

Storage temperature range

-40° C to 85° C (-40° F to 185° F)

D.3 -7

Page 262

Input Multi-Channel Resolver Module (12 channel)

Humidity

5 to 95%, non-condensing

CE Marked

Conforms to Directives 73/23/EEC, 89/336/EEC, 92/ 31/EEC, 93/68/EEC by conforming to the following standards: EN 50081-2:1993 EMC Generic Industrial Emissions EN 50082-2:1995 EMC Generic Industrial Immunity EN 61131-2:1994/A11:1996 Low voltage directive requirements for programmable controllers Operates with emissions below EN55011/ CISPR 11 Class A limits Immune to: • Electrostatic discharge (4K V contact mode, 8K V air discharge) per EN61000-4-2 • RF electromagnetic fields per EN61000-4-3, ENV 50141, and ENV50204 • Electrical fast transients per EN61000-4-4 • Magnetic fields per EN61000-4-8 Refer to the EMC Guidelines for more information.

UL and C/UL Listed

File No. E126417 NRAQ Programmable Controllers

Physical size

1.6" wide x 12" high x 8.4" deep (including latch) 41 mm x 305 mm x 213 mm

Vibration (per IEC 68-2-6)

10-57 Hz (constant amplitude .15 mm) 57 - 2000 Hz (acceleration 2 g)

Shock (per IEC 68-2-27)

D.3 -8

Four shocks per axis (15g/11 msec)