Page 315

D.8 - SERCOS Module Introduction

The SERCOS module is an interface between the PiC and one or two fiber optic rings. A ring can have from one to eight SERCOS slaves. The module contains an on board processor. Five LEDs provide diagnostic information and transmit and receive status for the SERCOS rings. There are one or two SERCOS ring ports located at the bottom of the module. Each ring port has a receive and a transmit fiber optic connector. There is also an RS232 port used for loading FLASH memory updates. Figure D8-1. SERCOS Module with Two Ring Ports

SERCOS

Name of module Diagnostic LED

Ring1 Ring 2

XMT REC XMT REC

SERCOS LEDs

RS232 port 9-pin D

T = Transmit R = Receive

R1

T2

T1

Ring 1

Key SERCOS Ring Ports Fiber Optic Connections on bottom (see inset)

R2

Ring 2

Bottom View of Ring Ports

D.8 -1

Page 316

SERCOS Module

Connections

SERCOS Ports

The SERCOS ports located on the bottom of the module can connect to one or two SERCOS rings. The connection to each ring is made through a pair of female fiber optic SMA connectors. The module’s transmitter is connected to the first receiver in the loop and the module’s receiver is connected to the last transmitter in the loop. Figure D8-2. SERCOS Connections - One Ring

PiC CSM CPU

PC connected to RS232 port for Field Updates of Giddings & Lewis system software

SERC

TR

Position, Velocity, or Torque Commands

Feedback and Diagnostics

Fiber Optic Ring

T

RT (Up to eight SERCOS slaves)

SERCOS Slave n

R SERCOS Slave 2

SERCOS Slave 1

R T

Serial Port

There is an RS232 serial port on the front of the module. This is used to connect to a PC in order to do a field update of the FLASH memory on the processor. The pinout is shown below. Figure D8-3. Pinout for the 9-Pin D Connector

D.8 -2

Pin #

Signal Name

In/Out

2 3 5

Receive Data Transmit Data Ground

In Out In/Out

Page 317

SERCOS Module

Theory of Operation

The SERCOS module is controlled by your LDO created in PiCPro. An on-board processor interprets the functions and performs appropriate operations according to the SERCOS communications protocol. The data transfer rate is 2M Baud with user-defined update rate. If a scan loss occurs, SERCOS communications are reset. There is no communication with the SERCOS slaves until you reinitialize.

D.8 -3

Page 318

SERCOS Module

Specification Table

Characteristic

SERCOS Module Specifications

Function

Interfaces with up to two rings with from one to eight digital drives

Part number

Two-Ring Module 502-03944-04

SERCOS port

SMA female connectors for interfacing to 1000 µ meter plastic fiber optic cable with SMA male connectors

Update port

RS232 interface

One-Ring Module 502-03944-14

Fiber optic receiver specifications: Peak input power (optical level low) Peak input power (optical level high

-31.2 dBm max -20.0 dBm min, -5 .0 dBm max

Fiber optic transmitter specifications: Peak output power (optical level high) -10.5 dBm min, -5.5 dBm max Logic side power requirements

575 mA @ 5V

Operating temperature range

7° C to 55° C (45° F to 131° F)

Storage temperature range

-40° C to 85° C (-40° F to 185° F)

Humidity

5 to 95%, non-condensing

D.8 -4

Page 319

SERCOS Module

CE Marked

Conforms to Directives 73/23/EEC, 89/336/EEC, 92/31/EEC, 93/ 68/EEC by conforming to the following standards: EN 50081-2:1993 EMC Generic Industrial Emissions EN 50082-2:1995 EMC Generic Industrial Immunity EN 61131-2:1994/A11:1996 Low voltage directive requirements for programmable controllers Operates with emissions below EN55011/ CISPR 11 Class A limits Immune to: • Electrostatic discharge (4K V contact mode, 8K V air discharge) per EN61000-4-2 • RF electromagnetic fields per EN61000-4-3, ENV 50141, and ENV50204 • Electrical fast transients per EN61000-4-4 • Magnetic fields per EN61000-4-8 Refer to the EMC Guidelines for more information.

UL and C/UL Listed

File No. E126417 NRAQ Programmable Controllers

Physical size

1.6" wide x 12" high x 8.4" deep (including latch) 41 mm x 305 mm x 213 mm

D.8 -5

Page 320

SERCOS Module

Specification Table for the Fiber Optic Cable

Characteristics

Fiber optic cable specifications

Function

For use with SERCOS rings with segments from 0 to 30 meters (98 feet)

Type

Plastic with step index profile

Core diameter Fiber diameter

980 µm ±60 µm 1000 µm ±60 µm

Operating temperature

0˚ C to 55˚ C (32˚ F to 131˚ F)

Minimum bend radius

One time: Continuous:

30 mm 80 mm

Tensile strength

One time: Continuous:

250 N 100 N

Connectors

SMA style which accommodates 1000 µm size cable

Vibration (per IEC 68-2-6)

10-57 Hz (constant amplitude .15 mm) 57 - 2000 Hz (acceleration 2 g)

Shock (per IEC 68-2-27)

D.8 -6

Four shocks per axis (15g/11 msec)