The text of a manual · part 37 of 60
PiC900 Hardware Manual: D.8 - SERCOS Module
Pages 315 to 320 of 508, from PiC900 Hardware Manual
The original document is the PDF (3.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Giddings & Lewis 502-03550-02
Page 315
D.8 - SERCOS Module Introduction
The SERCOS module is an interface between the PiC and one or two fiber optic rings. A ring can have from one to eight SERCOS slaves. The module contains an on board processor. Five LEDs provide diagnostic information and transmit and receive status for the SERCOS rings. There are one or two SERCOS ring ports located at the bottom of the module. Each ring port has a receive and a transmit fiber optic connector. There is also an RS232 port used for loading FLASH memory updates. Figure D8-1. SERCOS Module with Two Ring Ports
SERCOS
Name of module Diagnostic LED
Ring1 Ring 2
XMT REC XMT REC
SERCOS LEDs
RS232 port 9-pin D
T = Transmit R = Receive
R1
T2
T1
Ring 1
Key SERCOS Ring Ports Fiber Optic Connections on bottom (see inset)
R2
Ring 2
Bottom View of Ring Ports
D.8 -1
Page 316
SERCOS Module
Connections
SERCOS Ports
The SERCOS ports located on the bottom of the module can connect to one or two SERCOS rings. The connection to each ring is made through a pair of female fiber optic SMA connectors. The module’s transmitter is connected to the first receiver in the loop and the module’s receiver is connected to the last transmitter in the loop. Figure D8-2. SERCOS Connections - One Ring
PiC CSM CPU
PC connected to RS232 port for Field Updates of Giddings & Lewis system software
SERC
TR
Position, Velocity, or Torque Commands
Feedback and Diagnostics
Fiber Optic Ring
T
RT (Up to eight SERCOS slaves)
SERCOS Slave n
R SERCOS Slave 2
SERCOS Slave 1
R T
Serial Port
There is an RS232 serial port on the front of the module. This is used to connect to a PC in order to do a field update of the FLASH memory on the processor. The pinout is shown below. Figure D8-3. Pinout for the 9-Pin D Connector
D.8 -2
Pin #
Signal Name
In/Out
2 3 5
Receive Data Transmit Data Ground
In Out In/Out
Page 317
SERCOS Module
Theory of Operation
The SERCOS module is controlled by your LDO created in PiCPro. An on-board processor interprets the functions and performs appropriate operations according to the SERCOS communications protocol. The data transfer rate is 2M Baud with user-defined update rate. If a scan loss occurs, SERCOS communications are reset. There is no communication with the SERCOS slaves until you reinitialize.
D.8 -3
Page 318
SERCOS Module
Specification Table
Characteristic
SERCOS Module Specifications
Function
Interfaces with up to two rings with from one to eight digital drives
Part number
Two-Ring Module 502-03944-04
SERCOS port
SMA female connectors for interfacing to 1000 µ meter plastic fiber optic cable with SMA male connectors
Update port
RS232 interface
One-Ring Module 502-03944-14
Fiber optic receiver specifications: Peak input power (optical level low) Peak input power (optical level high
-31.2 dBm max -20.0 dBm min, -5 .0 dBm max
Fiber optic transmitter specifications: Peak output power (optical level high) -10.5 dBm min, -5.5 dBm max Logic side power requirements
575 mA @ 5V
Operating temperature range
7° C to 55° C (45° F to 131° F)
Storage temperature range
-40° C to 85° C (-40° F to 185° F)
Humidity
5 to 95%, non-condensing
D.8 -4
Page 319
SERCOS Module
CE Marked
Conforms to Directives 73/23/EEC, 89/336/EEC, 92/31/EEC, 93/ 68/EEC by conforming to the following standards: EN 50081-2:1993 EMC Generic Industrial Emissions EN 50082-2:1995 EMC Generic Industrial Immunity EN 61131-2:1994/A11:1996 Low voltage directive requirements for programmable controllers Operates with emissions below EN55011/ CISPR 11 Class A limits Immune to: • Electrostatic discharge (4K V contact mode, 8K V air discharge) per EN61000-4-2 • RF electromagnetic fields per EN61000-4-3, ENV 50141, and ENV50204 • Electrical fast transients per EN61000-4-4 • Magnetic fields per EN61000-4-8 Refer to the EMC Guidelines for more information.
UL and C/UL Listed
File No. E126417 NRAQ Programmable Controllers
Physical size
1.6" wide x 12" high x 8.4" deep (including latch) 41 mm x 305 mm x 213 mm
D.8 -5
Page 320
SERCOS Module
Specification Table for the Fiber Optic Cable
Characteristics
Fiber optic cable specifications
Function
For use with SERCOS rings with segments from 0 to 30 meters (98 feet)
Type
Plastic with step index profile
Core diameter Fiber diameter
980 µm ±60 µm 1000 µm ±60 µm
Operating temperature
0˚ C to 55˚ C (32˚ F to 131˚ F)
Minimum bend radius
One time: Continuous:
30 mm 80 mm
Tensile strength
One time: Continuous:
250 N 100 N
Connectors
SMA style which accommodates 1000 µm size cable
Vibration (per IEC 68-2-6)
10-57 Hz (constant amplitude .15 mm) 57 - 2000 Hz (acceleration 2 g)
Shock (per IEC 68-2-27)
D.8 -6