Page 485

O.1 - CE and EMC Guidelines

NOTE: The CE mark on PiC products assures compliance with both the EMC and low voltage European directives. Prior to this CE mark, EMC on the product label only assured compliance with the EMC directives. Background on EMC (Electromagnetic Compatibility) Compliance

In order to market products in the European Union after January 1, 1996, an electromagnetic compatibility directive (EU Directive 89/336/ECC) must be met. All products must be designed and manufactured in such a way that: 1.

Electromagnectic disturbances generated by the products do not cause interference to other systems.

2.

The performance of the product is not affected by electromagnetic disturbances within the environment in which the product is intended to operate.

The directive refers to relevant harmonized European EMC standards against which product conformity can be assessed, although other methods of assessment, notably the preparation of a Technical File, are permissible. The equipment manufacturer or the manufacturer’s agent in the Community must make a Declaration of Conformity and can place the CE mark on the product. Failure to conform with the requirements of the directive can result in a total ban on sales throughout the Single Market and legal action could be taken against the signatory of a false declaration of conformity. Background on Low Voltage Compliance

In order to market products in the European Union after January 1, 1997, the low voltage directive (EU Directive 73/23/EEC) must be met. The intention of the directive is to assure user safety under normal operating and fault conditions. The directive includes the use of certain warning labels and user instructions. It establishes limits to prevent electrical shock hazard, overheating and fire.

O.1 -3

Page 486

CE and EMC Guidelines

RFI Emission and Immunity

The EMC product characteristics are classified by the emission and immunity performance. Emissions not only include radiated noise from the product enclosure and cabling, but also that which is conducted away from the product along the cables connected to it. This may be subsequently radiated from the cable or conducted directly into another product which shares this cable e.g. the main AC supply. Immunity is how susceptible a product is (e.g. to the radiated and conducted emissions from the product mounted next to it). To ensure compatibility, the immunity of a product must always exceed the expected emissions in the environment in which it operates as is shown in the diagram below. This is to ensure a margin of safety. Figure O1-1. Safety Margin

Compatibility Levels

Immunity Level Safety Margin Emission Level Noise Level

In addition to conducted and radiated immunity, products must also be capable of withstanding: 1.

Electro-static discharges (ESD)

2.

Conducted fast transient voltages

The discharge spark generated from ESD can easily damage electronic components.The conducted fast transient voltages are induced in cables laid in close proximity to other cables in which large inductive loads are switched (such as relays, contactors, and AC motor starters). This is a good example of what can happen to sensitive control and signal cabling connected to drives when poorly installed in enclosures on industrial sites.

O.1 -4

Page 487

CE and EMC Guidelines

Classes of EMC Operating Environments

Before the correct level of EMC can be designed into equipment, the EMC operating environment must be defined. For example in industrial locations where high power equipment is in use, high levels of background electrical noise would be expected when compared to a household or office environment. Since it is more expensive to reduce the emissions from higher power equipment than to increase the immunity, the emission limits allowed in industrial environments are higher than for household or office environments. Vice versa for immunity because of the higher emission limits in industrial environments, the immunity requirements are more strict than for the household or office environment. Hence in order to achieve EMC between different equipment, it is essential to know what EMC operating environment it is to be installed in, and to compare the installation environment to the environment for which it was designed. Today using generic EMC standards, two environments are defined: 1.

Industrial

2.

Residential, commercial, and light industrial

The environments are locations defined on the basis of whether the AC supply is shared with other locations or is buffered from them with a distribution transformer. If your location is buffered via a distribution transformer, then you are in an industrial environment. If you share your AC supply with a neighboring location, then you are in a residential, commercial, or light industrial environment. For example, an industrial unit which shares its AC supply with a neighboring unit is defined as a residential, commercial, and light industrial location. If it is supplied from its own distribution transformer, then it is an industrial location. Conformance with the EMC Directive

Giddings & Lewis will comply with the Directive by self-certification to the following generic EMC standards: 1.

EN50081-2 for industrial emissions using EN55011 (based upon CISPR 11A)

2.

EN50082-2 for industrial immunity using IEC 61000-4-2 (ESD-4KV contact mode, 8 KV air discharge) IEC 61000-4-3 (Radiated susceptibility) IEC 61000-4-4 (Electrical fast transient) IEC 61000-4-8 (Magnetic Fields)

A statement of compliance will be made with the letters “EMC” or "CE" on the product, but will be valid only if the product is installed properly.

O.1 -5

Page 488

CE and EMC Guidelines

Conformance with the Low Voltage Directive

Giddings & Lewis will comply with the Directive by self-certification to the following standard: EN 61131-2:1994/A11:1996 Low Voltage Requirement for Programmable Controllers A statement of compliance will be made with the letters "CE" on the product but will be valid only if the equipment is properly installed. Changes to the PiC Products

Giddings & Lewis PiC products had originally been designed with a high level of noise immunity and tested according to standards such as NEMA showering arc and the original version of IEC 801-2. However, the EU directive for immunity requires testing to standards that have more variables and are more repeatable. The directive also requires control of emissions, something that is not regulated in U. S. industrial environments. As a result, changes have been made to the hardware modules within the PiC product line. The changes have included the addition of filtering, re-routing of foils and/or the addition of ground planes to printed circuit boards, use of some conductive enclosures, provision for shielded wires* for peer-to-peer communication, and internal connection of SPG to field side connectors. *A recommended shielded wire is: Belden

O.1 -6

24 AWG (7 X 32)

9729

Page 489

CE and EMC Guidelines

Changes Affecting the User

Many of the changes Giddings & Lewis has implemented are transparent to the user. However, there are some changes affecting user installation. Giddings & Lewis continues to recommend separation of low level signals (encoder, analog, communications, fast DC inputs) from high voltage or high current lines from any of the above. More specifically, maintain at least one inch of separation around encoder signals and around communication signals. It is no longer necessary to connect a wire from a module to SPG. This userinstalled wire had been a source of emissions and thus the connection should not be made. Analog modules typically had this requirement in the past. To prevent excessive conducted emissions from a DC power source (typically 24V) used for digital I/O, a 1000 picofarad capacitor should be used. Connect the capacitor from the +24V DC to COMMON at the distribution terminals. The same applies to any other external DC power source used with the PiC product. The figure on the left below illustrates the connection method before EMC compliant products were available. The figure on the right illustrates the recommended connections when using EMC compliant products. On the right, note that the SPG connection has been eliminated and that a capacitor is connected to the 24V DC supply. Figure O1-2. Connections before EMC Compliant Products

Recommended EMC Compliant Connections

COMMUNICATIONS

COMMUNICATIONS

ENCODER, ANALOG

PiC900

PiC900 SYSTEM

SYSTEM AC INPUT/OUTPUT and and MODULES

MODULES

DC INPUT/OUTPUT to AC I/O to DC I/O

+ AC INPUT POWER

ENCODER, ANALOG

GND

DC INPUT/OUTPUT to AC I/O

-

DC POWER SUPPLY

AC INPUT/OUTPUT to DC I/O Capacitor

+ AC INPUT POWER

-

DC POWER SUPPLY

GND

SINGLE-POINT GROUND

SINGLE-POINT GROUND

O.1 -7

Page 490

CE and EMC Guidelines

There is now a provision for shield termination to the CPU modules for peer-topeer communication. Shielded cable must be used to reduce emissions. Inside a control cabinet, the practice of connecting the shields of shielded cables at the modules should be continued. For shielded cable entering/leaving the cabinet, see the diagram below. Figure O1-3. Connecting Shielded Cable

PiC Module

External Device

C abinet Enclosure

The two different methods of terminating shields are used to accommodate two different immunity requirements. Immunity required inside an enclosure is considered lower because cables are typically less than 3 meters in length and/or can be separated from each other and from noise sources. Immunity required external to an enclosure is considered higher because the user may have less control over the noise environment. Low level signal cables that can be external to an enclosure and AC/DC digital I/O cables have been tested at a 2 KV level for electrical fast transients (EFTs). Low level signals that can be less than 3 meters in length or can be separated from noise sources are tested at a 1 KV level. Under the stated conditions, there will be no disturbance of digital I/O, encoder, or stepper operation. For analog signals, there may be momentary disturbances but there will be self-recovery when the noise subsides. In order to meet the EU directive requirement for emissions and immunity, fiber optics must be used for I/O expansion. Although the PiCs will pass the electrical fast transient test on incoming power lines, users may still want to use a power line conditioner as detailed in Chapter 1 of the PiC900 Hardware Manual. As a general precaution, do not operate transmitters, arc welding equipment, or other high noise radiators within one meter of a PiC enclosure that has the door open. Continue to equip inductive devices, if they are in series with a mechanical contact or switch, with arc suppression circuits. These devices include contactors, solenoids and motors. Shield all cables that carry heavy current near the system, using continuous foil wrap or conduit grounded at both ends. Such cables include power leads for high-frequency welders and for pulse-width-modulated motor drives. O.1 -8

Page 491

CE and EMC Guidelines

NOTE: Shields for signal wires are grounded at only one end, to provide immunity to outside noise sources. However, the shields for "noise sources" are grounded at both ends, to reduce emissions and "contain" the noise. Worst case tests with analog I/O modules have caused momentary disturbances no greater than .5V in a +10V to -10V range and .5 mA in a 4 to 20 mA range. Worst case tests with an RTD module have caused momentary disturbances no greater that + or -4°C in a range of -200° to 266°C. Worst case tests with a JK thermocouple module have caused momentary disturbances no greater than + or - 1 mV over a 100 to 1. NOTE: To assure compliance with the low voltage directive, it is necessary to follow installation instructions in the controller Hardware Manual. Also refer to any instructions specific to individual control modules.

O.1 -9

Page 492

CE and EMC Guidelines

Using CE/EMC and Non-CE/EMC Modules

IMPORTANT: Failure to follow these guidelines may result in undesired system performance! NOTE:

CE indicates compliance to both the EMC and low voltage directives. EMC indicates compliance to the EMC directive.

There are several issues that must be considered when using CE/EMC compliant and Non-CE/EMC compliant Modules. This document addresses these issues. Module Identification - To determine whether a module is CE/EMC or Non-CE/ EMC, look at the gray Unit Tag located on the side of the plastic module case. CE/ EMC modules will have "CE" or “EMC” printed near the “MAX. AMBIENT TEMP.” specification. Non-CE/EMC will not have “EMC” or "CE" printed in this location. Grounding - Due to differences in shielding requirements, it is extremely important to follow proper shielding guidelines for a given module. Failure to do so may result in intermittent operation in noisy environments. For modules that have an SPG terminal and/or one or more SHIELD terminal, perform the following: For CE/EMC modules, do not connect the SPG terminal or SHIELD terminals to the system’s Single Point Ground. • For Non-CE/EMC modules, connect the SPG terminal, or a SHIELD terminal, to the system’s Single Point Ground •

CE/EMC CSM and RSM Modules - Using an CE/EMC CSM, RSM, or CSM/ CPU (PiC90) with certain Non-CE/EMC analog modules may cause intermittent operation. Follow these guidelines for determining the type of CSM, RSM, or CSM/CPU that should be used in a particular rack: If your rack contains one or more Non-CE/EMC modules that perform D/A conversion or provide an Encoder interface, you must use a non-CE/EMC CSM, RSM, or CSM/CPU (PiC90). • If your rack does not contain one or more Non-CE/EMC modules that perform D/A conversion or provide an Encoder interface, you may use either a CE/EMC or Non-CE/EMC CSM, RSM, or CSM/CPU (PiC90). •

NOTE: All modules and backplanes must be CE/EMC compliant for a system to be CE/ EMC compliant.

O.1 -10

Page 493 read from a scan by OCR; it may hold reading errors

Application of Council Directives

Manufacturer’s Name: Manufacturer’s Address:

European Representative Name: European Representative Address:

CE and EMC Guidelines

EMC Directive and Low Voltage Directive

DECLARATION OF CONFORMITY

73/23/EEC, 89/336/EEC, 92/3 I/EEC, 93/68/EEC

Giddings & Lewis Controls, Measurement, and Sensing 660 South Military Road Fond du Lac, Wisconsin 54936-1658

Cross Hiller Randics Road, Knowsley Industrial Park

Prescot, Merseyside L34 9EZ England

Herewith declares that all PXC9IOG™/PiIC90™/ PiC9™ and Block /O modules listed below,

502-035 12-03,07 502-03674-02,22 $02-03839-04 502-04030-00 503-25 164-02 502-035 18-03,23 502-03674-42 502-03840-04,24 502-04050-00 §03-25187-01,11 502-03548-00 502-03676-03,23 $02-03840-44 502-04073-20 $03-25188-01,11 502-03549-02 302-03677-02,22 502-03842-02 502-04077-00,20 §03-25189-01,11 502-03 550-02,06 502-13677-42 502-03843-02 502-04077-40 §03-25768-01,11 502~0355 1-03,08 302-03679-02 502-03846-X3 502-04 104-0174 503-25906-01 502-03552-02,22 302-0368 1-02,07 502-03853-K3 502-04110-00, 10 $03-235907-01 302-03605-00,05 502-03692-03 502-03876-02 502-04111-01,11 303-25908-01 502-03640-02,07 502-03698-22 502-03882-KX 502-04112-01,11 303-25909-0L 3502-~03641-03,08 502-03722-02 502-03907-03 30204125401, 11 503-25910-01 502-03642-03,08 502-03732-03,07 302-03 944-KX 302-04126-00, 10 303-25986-01 302-03643-00 502-03782-02,22 502-03947-00 303=13704-00 303-25937-01 502-03644-03 502-03786-02,22 502-03956-02 303-18009-03,08 503-259383-01 502-0365 1-00 502-03809-02 302-03963-X 1 303-180 50-03,038 X=0 - >9 502-03657-03 07 502-038 10-03 5302-03973 -00 503-18011-03,08

502-03658-02 302-03813-03,07 502-03994-X1 503-19 184-02

502-03673-00 $02-03817-03,07 $02-04011-X1 503-19185-02 when installed in accordance with the instructions contained in the “PiC900 Hardware Manual” (P/N 401-545 14-00), conform to the following generic and basic standards.

EN 5$0081-2:1993 EMC Generic Industrial Emissions EN 50082-2;1995 EMC Generic Industrial Immunity EN 61131-2:1994/A11:1996 Low voltage requirements for programmable controllers

Future modules (with higher P/N’s) labeled with the CE mark will also conform to these standards.

We, the undersigned, hereby declare that the equipment specified above conforms to the above directive(s). Legal Representative 7 Europe

Signature \ Vv . Full Name Roger M. Collins Pesition Managing Director Place Cross Hiller Date

S718 AG

0.1 -11

Page 494 read from a scan by OCR; it may hold reading errors

CE and EMC Guidelines

EMC Directive and Low Voltage Directive DECLARATION OF CONFORMITY

Application of Council Directives _73/23/EEC, 89/336/EEC, 92/3 1/EEC, 93/68/EEC

Manufacturer’s Name: Giddings & Lewis Controls, Measurement, and Sensing Manufacturer’s Address: 660 South Military Road Fond du Lac, Wisconsin 54936-1658

European Representative Name: Cross Hiller European Representative Address: Randles Road, Knowsley Industrial Park Prescot, Merseyside L34 9EZ England

Herewith declares that all MMC (Machine and Motion Control) units listed below,

503-26606-XX, 503-26683-XX, 503-26684-XX, 503-26842-XX ~ 503-26856-XX (X=079)

and approved cables and accessories, when installed in accordance with the instructions contained in the “MMC Hardware Manual” (P/N 108-31050-00), conform to the following generic and basic standards.

EN 50081-2:1993 EMC Generic Industrial Emissions EN 50082-2:1995 EMC Generic Industrial Immunity EN 61131-2:1994/A11:1996 Low voltage requirements for programmable controllers

MMC units bear the CE mark to indicate conformance to these standards.

We, the undersigned, hereby declare that the equipment specified above conforms to the above directive(s).

Legal Representative in Europe

Signature \ ( LA

Full Name Roger M. Collins

Position Managing Director

Place Cross Hiiller

Date act \e@ 84

0.1 -12

Page 495 read from a scan by OCR; it may hold reading errors

Manufacturer’s Name: Manufacturer’s Address:

CE and EMC Guidelines

EMC Directive and Low Voltage Directive DECLARATION OF CONFORMITY

Application of Council Directive(s) _73/23/EEC,89/336/EEC, 92/3 L/EEC, 93/68/EEC

European Representative Name:

European Representative Address:

Cross Hiller

Giddings & Lewis Controls, Measurement, and Sensing 660 South Military Road Fond du Lac, Wisconsin 54936-1658

Randles Road, Knowsley Industrial Park Prescot, Merseyside L34 9EZ England

Herewith declares that all servo drives listed below,

Model Name DSMi 10 DSM120 DSM130 DSM175 DSM1150 DSM007 DSMO15

Part Number

401-34400-00 401-34401-00 401-34402-00 401-34403-00 401-34404-00 401-56451-00 401-56452-00

Model Name DSM030 DSM110P DSM120P DSM130P DSM175P DSM1150P DSM607P

Part Number

401-56453-00 401-34400-50 401-34401-50 401-34402-50 401-34403-50 401-34404-50 401-5645 1-50 when operating any of the following motor families, SSM, HSM, NSM, YSM and FSM when operating with or without the optional Touch Pad, P/N 401-34405-00 and when installed in accordance with the installation instructions contained in the “Centurion DSM100 Drive Hardware and Installation Manual” (P/N 108-30083-00), or “MicraDSM Installation Manual” (P/N 108-31017-00), conform to the following generic and basic standards.

EN 55011:1993 EN 50082-2:1995

61000-4-8

EN 60204: 1993

(CISPR 1} Group 1 class A EN 61000-4-2, ENV 50140, ENV 50204, EN 61000-4-4, ENV 50141, EN

Model Name DSMOI1SP DSM030P DSM110 SERCOS DSM120 SERCOS DSM130 SERCOS DSM175 SERCOS DSM11450 SERCOS

Part Number

40 1-56452-50 401-56453-50 401-30277-00 401-30278-006 401-30279-00 401-30230-00 401-3023 1-00

We, the undersigned, hereby declare that the equipment specified above conforms to the above directive(s). Legal Representatwe jn Europe Signature Full Name Roger M. Collins Position Managing Director Place Cross Huller Date Oczr 12 BV

0.1 -13

Page 496 read from a scan by OCR; it may hold reading errors

CE and EMC Guidelines

Ls} Cutler-Hammer E:T-N

/~ Declaration of Conformity

Cutler-Hammer Automation 173 Heatherdown Drive P. O. Box 6166 Westerville, Ohio 43086-6166 Phone (614) 882-3282

We as the manufacturer, declare under our sole responsibility that the products listed below bearing the “CE” Mark to which this Declaration relates are in conformity with the provisions of the directives and standards referenced:

Giddings & Lewis Operator Interface Products

Models:

Trueview 2180 Series Trueview 3100 Series Trueview 3300 Series Trueview 3400 Series

Directives and Standards 73/23(EEC Low-Voltage $9/336/EEC EMC (Electromagnetic Compatibility) Directive Directive EN 50081-2 Generic Emissions | EN 50082-2 Generic Immunity EN 61000-4-2, 1995 EN 61000-4-5, 1995 EN 61000-4-11, 1994 EN 61131-2, 1994 EN 61000-4-3, 1996 EN 61000-4-6, 1996 EN 61131-2, 1995 EN 61000-4-4, 1995 EN 61000-4-8, 1993 EN $5022 “A”, 1994

This Declaration is issued from the location shown above and is authorized by: Nha Re Eoashact 1--49

LO R. Gearhart, M Product Develop and Project Management Date