For the Giddings & Lewis 502-03550-02

Page 31

PiC904X- CSM/CPU Central Service Module/

Central Processing Unit Logic side power requirements (typical)

450 mA 650 mA 600 mA 800 mA

@ @ @ @

+5V +5V +5V +5V

5 mA @ +15V 10 mA @ -15V 40 mA @ -15V 5 µA @ +3V Operating temperature range

M.1016.9615 (old # 502-04104-01) M.1016.9617 (old # 502-04104-11) M.1016.9677 (old # 502-04125-01) M.1016.9679 (old # 502-04125-11), M.1016.9682 (old # 502-04126-10) all M.1016.9615 (old # 502-04104-01), M.1016.9677 (old # 502-04125-01) M.1016.9617 (old # 502-04104-11), M.1016.9678 (old # 502-04125-10), M.1016.9682 (old # 502-04126-10) (all) From the battery during power down

7° C to 55° C (45° F to 131° F)

Storage temperature range -40° C to 85° C (-40° F to 185° F) Humidity

5 to 95%, non-condensing

EMC Compliant

In progress

CE Marked

Conforms to Directives 73/23/EEC, 89/336/EEC, 92/31/EEC, 93/68/ EEC by conforming to the following standards: EN 50081-2:1993 EMC Generic Industrial Emissions EN 50082-2:1995 EMC Generic Industrial Immunity EN 61131-2:1994/A11:1996 Low voltage directive requirements for programmable controllers Operates with emissions below EN5501/CISPR 11 Class A limits Immune to: • Electrostatic discharge (4K V contact mode, 8K V air discharge) per EN61000-4-2 • RF electromagnetic fields per EN61100-4-3, ENV50141, and ENV50204 • Electrical fast transients per EN61000-4-4 • Magnetic fields per EN61000-40

UL and C/UL Listed

File No. E1226417 NRAQ Programmable Controllers

Physical size

2.4" wide x 12" high x 8.4" deep (including latch) 61 mm x 305 mm x 213 mm

Vibration (per IEC 68-26)

10-57 Hz (constant amplitude .15 mm)

Shock (per IEC 68-2-27)

Four shocks per axis (15g/11msec)

Giddings & Lewis

57-2000 Hz (acceleration 2 g)

PiC900 Controls Motion Solutions Product Guide

27

Page 32

PiC904X- CSM/CPU Central Service Module/Central Processing Unit

28

PiC900 Controls Motion Solutions Product Guide

Giddings & Lewis

Page 33

PiC900 CONTROLS MOTION SOLUTIONS PRODUCT GUIDE

PiC 900 Communications Modules

Giddings & Lewis

Page 34

This page is a scan with no text; see it in the PDF.

Page 35

Ethernet - TCP/IP Module

Ethernet - TCP/IP Module The Ethernet - TCP/IP module provides the PiC with Ethernet access and Internet connectivity. Connections for 10Base T, 10Base 2, and AUI (Attachment Unit Interface) are provided following the IEEE 802.3 specification. The data transfer rate is 10 Mbps. Applications can range from connecting several PiCs, connecting groups of PiCs and PCs, or connecting to a system that includes Internet access. The Remote Programmer Access key will allow you to enable/disable PiCPro for Windows running over Ethernet. The DIAG LED goes on briefly while the diagnostic tests are running shortly after power is applied. NOTE: The Ethernet module must be used with an EMC-compliant or CE-marked rack.

Ethernet - TCP/IP Module

Name of Module

ETHERNET - TCP/IP

Diagnostic LED

DIAG IN

OUT GDLNK

ETHERNET

Ethernet Port LEDs

PREV COL IN

OUT

IN

OUT

RS232-1

Ethernet Port LEDs

RS232-2

REMOTE PROGRAMMER ACCESS

Remote Programmer Access Key

Enable Disable STATUS

RS232 COMM Port 1

RS232 COMM Port 2

CNFG PORT

DeviceNet PORT tm

10Base T RJ-45 8-pin connector AIU 15-pin D connector CNFG PORT

Door 10 Base 2 BNC connector

Giddings & Lewis

PiC900 Controls Motion Solutions Product Guide

31

Page 36

Ethernet - TCP/IP Module Specification Table Characteristics

Ethernet - TCP/IP Module Specifications

Function

Provides the PiC with Ethernet access and Internet connectivity

Part number

M.1016.9694 (old # 502-04137-00)

RS232 Port 1

Com Port 1 modem (future)

RS232 Port 2

Com Port 2 (for firmware and configuration loading)

10Base T

RJ-45 8-pin connector Maximum twisted pair length is 100 m (328 ft.).

AUI

15-pin D connector Maximum twisted pair length is 50 m (164 ft.).

10Base 2

BNC connector Maximum coax cable length is 185 m (607 ft.).

Logic side power requirements (typical)

+5V +15V -15V

Operating temperature range

7° C to 55° C (45° F to 131° F)

Storage temperature range

-40° C to 85° C (-40° F to 185° F)

Humidity

5 to 95%, non-condensing

@ 1250 mA @ 30 mA @ 30 mA maximum maximum

EMC Compliant Emissions Noise immunity

Operates with emissions below EN55011/ CISPR 11 Class A limits Immune to: • Electrostatic discharge (4K V contact mode, 8KV air discharge) per IEC 1000-4-2 • RF electromagnetic fields per IEC 1000-4-3 • Electrical fast transients per IEC 1000-4-4 on incoming power lines Refer to the EMC Guidelines for more information.

32

PiC900 Controls Motion Solutions Product Guide

Giddings & Lewis

Page 37

Ethernet - TCP/IP Module

CE Marked

Conforms to Directives 73/23/EEC, 89/336/EEC, 92/ 31/EEC, 93/68/EEC by conforming to the following standards: EN 50081-2:1993 EMC Generic Industrial Emissions EN 50082-2:1995 EMC Generic Industrial Immunity EN 61131-2:1994/A11:1996 Low voltage directive requirements for programmable controllers Operates with emissions below EN5501/CISPR 11 Class A limits Immune to: • Electrostatic discharge (4K V contact mode, 8K V air discharge) per EN61000-4-2 • RF electromagnetic fields per EN61100-4-3, ENV50141, and ENV50204

UL and C/UL Listed

File No. E126417 NRAQ Programmable Controllers

Physical size

1.6" wide x 12" high x 8.4" deep (including latch) 41 mm x 305 mm x 213 mm

Vibration (per IEC 68-2-6)

10-57 Hz (constant amplitude .15 mm) 57 - 2000 Hz (acceleration 2 g)

Shock (per IEC 68-2-27)

Giddings & Lewis

Four shocks per axis (15g/11 msec)

PiC900 Controls Motion Solutions Product Guide

33

Page 38

DeviceNet Module

DeviceNet Module The DeviceNet scanner module is an interface between the PiC and a DeviceNet network. The module contains an on-board processor, a DeviceNet compliant interface, and firmware that makes it act as the master to all other nodes on the network. Prior to initial operation, a file is generated with specific configuration software in an external PC. This file must be downloaded via the RS232 configuration port to the DeviceNet module prior to initial operation. Two indicator LEDs (IN/OUT) are connected to this configuration port. Directly above the DeviceNet port are two LEDs that provide operation information: Network Status and DeviceNet Scanner Status. The DIAG LED goes on briefly while the diagnostics tests are running. NOTE: The DeviceNet module must be used with an EMC-compliant or CEmarked rack.

DeviceNet Module DeviceNet

Name of module

TM

Diagnostic LED

DIAG IN

OUT

CNFG PORT

NETWORK STATUS NETWORK STATUS

Configuration Port LEDs

SCANNER

SCANNER STATUS

Network Status DeviceNet Port Phoenix 5-pin

DeviceNet Scanner Status

Door

CNFG PORT

DeviceNet tm

PORT

STATUS

Configuration Port RS232 Port CNFG 9-pin D PORT

34

PiC900 Controls Motion Solutions Product Guide

Giddings & Lewis

Page 39

DeviceNet Module Specification Table

Characteristics

DeviceNet Module Specifications

Function

Interfaces to a DeviceNet network with up to 63 other nodes

Part number

M.1016.9719 (old # 502-04157-00)

DeviceNet Port

Phoenix style 5-pin male connector

Configuration Port

RS232 interface

Logic side power requirements (typical)

275 mA @ 5 V

Operating temperature range

7° C to 55° C (45° F to 131° F)

Storage temperature range

-40° C to 85° C (-40° F to 185° F)

Humidity

5 to 95%, non-condensing

EMC Compliant Emissions Noise immunity

Operates with emissions below EN55011/ CISPR 11 Class A limits Immune to: • Electrostatic discharge (4K V contact mode, 8KV air discharge) per IEC 1000-4-2 • RF electromagnetic fields per IEC 1000-4-3 • Electrical fast transients per IEC 1000-4-4 on incoming power lines Refer to the EMC Guidelines for more information.

UL and C/UL Listed

File No. E126417 NRAQ Programmable Controllers

Physical size

1.6" wide x 12" high x 8.4" deep (including latch) 41 mm x 305 mm x 213 mm

Vibration (per IEC 68-2-6)

10-57 Hz (constant amplitude .15 mm) 57 - 2000 Hz (acceleration 2 g)

Shock (per IEC 68-2-27)

Giddings & Lewis

Four shocks per axis (15g/11 msec)

PiC900 Controls Motion Solutions Product Guide

35

Page 40

Serial Communications Module (2, 4 channel)

Serial Communications Module (2, 4 channel) The serial communications module provides two or four channels to be used for asynchronous serial communication with external devices such as computers, operator interface devices, etc. For each channel, RS232 electrical interface is provided for data and control lines; RS422/485 electrical interface is provided for data lines. The DIAG LED goes on briefly while the diagnostic tests are running

Serial COMMUNICATIONS Module (2, 4 ch) COMMUNICATIONS

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39

36

Name of Module Diagnostic LED

Screw terminal connector

Door

PiC900 Controls Motion Solutions Product Guide

Giddings & Lewis