The text of a manual · part 4 of 15
PiC900 Controls Motion Solutions Product Guide, pages 31 to 40
Pages 31 to 40 of 150
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Giddings & Lewis 502-03550-02
Page 31
PiC904X- CSM/CPU Central Service Module/
Central Processing Unit Logic side power requirements (typical)
450 mA 650 mA 600 mA 800 mA
@ @ @ @
+5V +5V +5V +5V
5 mA @ +15V 10 mA @ -15V 40 mA @ -15V 5 µA @ +3V Operating temperature range
M.1016.9615 (old # 502-04104-01) M.1016.9617 (old # 502-04104-11) M.1016.9677 (old # 502-04125-01) M.1016.9679 (old # 502-04125-11), M.1016.9682 (old # 502-04126-10) all M.1016.9615 (old # 502-04104-01), M.1016.9677 (old # 502-04125-01) M.1016.9617 (old # 502-04104-11), M.1016.9678 (old # 502-04125-10), M.1016.9682 (old # 502-04126-10) (all) From the battery during power down
7° C to 55° C (45° F to 131° F)
Storage temperature range -40° C to 85° C (-40° F to 185° F) Humidity
5 to 95%, non-condensing
EMC Compliant
In progress
CE Marked
Conforms to Directives 73/23/EEC, 89/336/EEC, 92/31/EEC, 93/68/ EEC by conforming to the following standards: EN 50081-2:1993 EMC Generic Industrial Emissions EN 50082-2:1995 EMC Generic Industrial Immunity EN 61131-2:1994/A11:1996 Low voltage directive requirements for programmable controllers Operates with emissions below EN5501/CISPR 11 Class A limits Immune to: • Electrostatic discharge (4K V contact mode, 8K V air discharge) per EN61000-4-2 • RF electromagnetic fields per EN61100-4-3, ENV50141, and ENV50204 • Electrical fast transients per EN61000-4-4 • Magnetic fields per EN61000-40
UL and C/UL Listed
File No. E1226417 NRAQ Programmable Controllers
Physical size
2.4" wide x 12" high x 8.4" deep (including latch) 61 mm x 305 mm x 213 mm
Vibration (per IEC 68-26)
10-57 Hz (constant amplitude .15 mm)
Shock (per IEC 68-2-27)
Four shocks per axis (15g/11msec)
Giddings & Lewis
57-2000 Hz (acceleration 2 g)
PiC900 Controls Motion Solutions Product Guide
27
Page 32
PiC904X- CSM/CPU Central Service Module/Central Processing Unit
28
PiC900 Controls Motion Solutions Product Guide
Giddings & Lewis
Page 33
PiC900 CONTROLS MOTION SOLUTIONS PRODUCT GUIDE
PiC 900 Communications Modules
Giddings & Lewis
Page 34
Page 35
Ethernet - TCP/IP Module
Ethernet - TCP/IP Module The Ethernet - TCP/IP module provides the PiC with Ethernet access and Internet connectivity. Connections for 10Base T, 10Base 2, and AUI (Attachment Unit Interface) are provided following the IEEE 802.3 specification. The data transfer rate is 10 Mbps. Applications can range from connecting several PiCs, connecting groups of PiCs and PCs, or connecting to a system that includes Internet access. The Remote Programmer Access key will allow you to enable/disable PiCPro for Windows running over Ethernet. The DIAG LED goes on briefly while the diagnostic tests are running shortly after power is applied. NOTE: The Ethernet module must be used with an EMC-compliant or CE-marked rack.
Ethernet - TCP/IP Module
Name of Module
ETHERNET - TCP/IP
Diagnostic LED
DIAG IN
OUT GDLNK
ETHERNET
Ethernet Port LEDs
PREV COL IN
OUT
IN
OUT
RS232-1
Ethernet Port LEDs
RS232-2
REMOTE PROGRAMMER ACCESS
Remote Programmer Access Key
Enable Disable STATUS
RS232 COMM Port 1
RS232 COMM Port 2
CNFG PORT
DeviceNet PORT tm
10Base T RJ-45 8-pin connector AIU 15-pin D connector CNFG PORT
Door 10 Base 2 BNC connector
Giddings & Lewis
PiC900 Controls Motion Solutions Product Guide
31
Page 36
Ethernet - TCP/IP Module Specification Table Characteristics
Ethernet - TCP/IP Module Specifications
Function
Provides the PiC with Ethernet access and Internet connectivity
Part number
M.1016.9694 (old # 502-04137-00)
RS232 Port 1
Com Port 1 modem (future)
RS232 Port 2
Com Port 2 (for firmware and configuration loading)
10Base T
RJ-45 8-pin connector Maximum twisted pair length is 100 m (328 ft.).
AUI
15-pin D connector Maximum twisted pair length is 50 m (164 ft.).
10Base 2
BNC connector Maximum coax cable length is 185 m (607 ft.).
Logic side power requirements (typical)
+5V +15V -15V
Operating temperature range
7° C to 55° C (45° F to 131° F)
Storage temperature range
-40° C to 85° C (-40° F to 185° F)
Humidity
5 to 95%, non-condensing
@ 1250 mA @ 30 mA @ 30 mA maximum maximum
EMC Compliant Emissions Noise immunity
Operates with emissions below EN55011/ CISPR 11 Class A limits Immune to: • Electrostatic discharge (4K V contact mode, 8KV air discharge) per IEC 1000-4-2 • RF electromagnetic fields per IEC 1000-4-3 • Electrical fast transients per IEC 1000-4-4 on incoming power lines Refer to the EMC Guidelines for more information.
32
PiC900 Controls Motion Solutions Product Guide
Giddings & Lewis
Page 37
Ethernet - TCP/IP Module
CE Marked
Conforms to Directives 73/23/EEC, 89/336/EEC, 92/ 31/EEC, 93/68/EEC by conforming to the following standards: EN 50081-2:1993 EMC Generic Industrial Emissions EN 50082-2:1995 EMC Generic Industrial Immunity EN 61131-2:1994/A11:1996 Low voltage directive requirements for programmable controllers Operates with emissions below EN5501/CISPR 11 Class A limits Immune to: • Electrostatic discharge (4K V contact mode, 8K V air discharge) per EN61000-4-2 • RF electromagnetic fields per EN61100-4-3, ENV50141, and ENV50204
UL and C/UL Listed
File No. E126417 NRAQ Programmable Controllers
Physical size
1.6" wide x 12" high x 8.4" deep (including latch) 41 mm x 305 mm x 213 mm
Vibration (per IEC 68-2-6)
10-57 Hz (constant amplitude .15 mm) 57 - 2000 Hz (acceleration 2 g)
Shock (per IEC 68-2-27)
Giddings & Lewis
Four shocks per axis (15g/11 msec)
PiC900 Controls Motion Solutions Product Guide
33
Page 38
DeviceNet Module
DeviceNet Module The DeviceNet scanner module is an interface between the PiC and a DeviceNet network. The module contains an on-board processor, a DeviceNet compliant interface, and firmware that makes it act as the master to all other nodes on the network. Prior to initial operation, a file is generated with specific configuration software in an external PC. This file must be downloaded via the RS232 configuration port to the DeviceNet module prior to initial operation. Two indicator LEDs (IN/OUT) are connected to this configuration port. Directly above the DeviceNet port are two LEDs that provide operation information: Network Status and DeviceNet Scanner Status. The DIAG LED goes on briefly while the diagnostics tests are running. NOTE: The DeviceNet module must be used with an EMC-compliant or CEmarked rack.
DeviceNet Module DeviceNet
Name of module
TM
Diagnostic LED
DIAG IN
OUT
CNFG PORT
NETWORK STATUS NETWORK STATUS
Configuration Port LEDs
SCANNER
SCANNER STATUS
Network Status DeviceNet Port Phoenix 5-pin
DeviceNet Scanner Status
Door
CNFG PORT
DeviceNet tm
PORT
STATUS
Configuration Port RS232 Port CNFG 9-pin D PORT
34
PiC900 Controls Motion Solutions Product Guide
Giddings & Lewis
Page 39
DeviceNet Module Specification Table
Characteristics
DeviceNet Module Specifications
Function
Interfaces to a DeviceNet network with up to 63 other nodes
Part number
M.1016.9719 (old # 502-04157-00)
DeviceNet Port
Phoenix style 5-pin male connector
Configuration Port
RS232 interface
Logic side power requirements (typical)
275 mA @ 5 V
Operating temperature range
7° C to 55° C (45° F to 131° F)
Storage temperature range
-40° C to 85° C (-40° F to 185° F)
Humidity
5 to 95%, non-condensing
EMC Compliant Emissions Noise immunity
Operates with emissions below EN55011/ CISPR 11 Class A limits Immune to: • Electrostatic discharge (4K V contact mode, 8KV air discharge) per IEC 1000-4-2 • RF electromagnetic fields per IEC 1000-4-3 • Electrical fast transients per IEC 1000-4-4 on incoming power lines Refer to the EMC Guidelines for more information.
UL and C/UL Listed
File No. E126417 NRAQ Programmable Controllers
Physical size
1.6" wide x 12" high x 8.4" deep (including latch) 41 mm x 305 mm x 213 mm
Vibration (per IEC 68-2-6)
10-57 Hz (constant amplitude .15 mm) 57 - 2000 Hz (acceleration 2 g)
Shock (per IEC 68-2-27)
Giddings & Lewis
Four shocks per axis (15g/11 msec)
PiC900 Controls Motion Solutions Product Guide
35
Page 40
Serial Communications Module (2, 4 channel)
Serial Communications Module (2, 4 channel) The serial communications module provides two or four channels to be used for asynchronous serial communication with external devices such as computers, operator interface devices, etc. For each channel, RS232 electrical interface is provided for data and control lines; RS422/485 electrical interface is provided for data lines. The DIAG LED goes on briefly while the diagnostic tests are running
Serial COMMUNICATIONS Module (2, 4 ch) COMMUNICATIONS
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39
36
Name of Module Diagnostic LED
Screw terminal connector
Door
PiC900 Controls Motion Solutions Product Guide
Giddings & Lewis