HEIDENHAIN product information sheet (October 2006) for the EXE 600 series interpolation and digitizing electronics, which take 11 µAPP encoder signals and put out TTL signals. Its specification table lists the EXE 602 E and EXE 660 B; it does not name the EXE 610 C or EXE 650 B it is also filed under. It gives a dimension drawing, specifications, connecting cable part numbers and connector pin layouts.
- Device
- EXE 600 series interpolation and digitizing electronics p. 1, 2
- Input
- 11 µAPP on an M23 flange socket (female), 9-pin p. 2, 3
- Output
- TTL on an M23 flange socket (male), 12-pin p. 2, 3
- Power supply
- 5 V ± 5% p. 3
- Protection
- IP 65 p. 3
- Weight
- 0.7 kg p. 3
- Reference mark signal
- Pulse width 90° elec. or ungated (only without interpolation) or 270° elec. p. 3
- Fault indication
- Fault detection signal, or in addition Ua1/Ua2 high impedance p. 3
- Interpolation (series)
- Without, 5-fold, 25-fold, 50-fold, 100-fold, 200-fold or 400-fold, by version p. 3
- Output cable
- M23 connecting cable, 12-pin: complete Id. Nr. 298 399-xx; with one connector Id. Nr. 309 777-xx p. 4
- Cable and connector
- Cable only Id. Nr 244 957-01; 12-pin female connector Id. Nr. 291 697-05 p. 4
- Input cable
- Connecting or adapter cable with a 9-pin male M23 connector; see HEIDENHAIN catalogs p. 4
What this sheet walks you through
- Dimensions and mounting of the EXE 600 housing p. 2
- Specifications of the EXE 602 E and EXE 660 B p. 3
- Choosing connecting cables and connectors p. 4
- Pin layout of the 9-pin input and 12-pin output connectors p. 4
Good to know
- The actual input frequency can be up to 5% lower than the nominal value; exceeding the limit causes failure. p. 3
- Vacant pins or wires must not be used. p. 4
- The wire color assignment applies only to the extension cable. p. 4
- The sensor line is connected internally to the matching power line. p. 4
Questions this sheet answers
What input signal does the EXE 602 E take?
11 µAPP signals through a 9-pin female M23 flange socket. p. 3
What is the part number of the HEIDENHAIN 12-pin M23 connecting cable?
Id. Nr. 298 399-xx complete, or Id. Nr. 309 777-xx with one connector. p. 4
What supply voltage does the EXE 600 series need?
5 V ± 5%. p. 3
The file
Size and text
Every page · 4
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 4
Open in the PDF
The text of page 1, from the PDF itself
Product Information
EXE 600 Series Interpolation and Digitizing Electronics
October 2006
Page2of 4
Open in the PDF
The text of page 2, from the PDF itself
EXE 600 Series Interpolation and Digitizing Electronics
- Input signals » 11 µAPP
- Output signals « TTL
Tolerancing ISO 8015 ISO 2768 - m H < 6 mm: ±0.2 mm
57175 ¬ 4.38052±0.240¬ 8.5M4 x 20 ISO 476223HEIDENHAINM42274163±0.2614599
Product Information for Series EXE 600
10/2006
Page3of 4
Open in the PDF
The text of page 3, from the PDF itself
SpecificationsEXE 602 EInput» 11 µAPPElectrical Connection
M23 flange socket (female) 9-pin
Cable length
† 30 m for IEncoder † 120 mA
1)EXE 660 BInterpolationWithout, 5-fold
Input frequency1) for interpolation
Nominal values2)
25-fold, 50-fold, 100-fold, 200-fold, 400-fold
Without 50 kHz–5-fold 25 kHz–25-fold –50 kHz50 kHz25 kHz12.5 kHz50-fold –50 kHz25 kHz12.5 kHz6.25 kHz100-fold –25 kHz12.5 kHz6.25 kHz3.12 kHz200-fold –12.5 kHz6.25 kHz3.12 kHz1.56 kHz400-fold –6.25 kHz3.12 kHz1.56 kHz0.78 kHz‡ 0.370 µs‡ 0.760 µsOutput« TTL (unclocked)Electrical connection
M23 flange socket (male) 12-pin
Cable length† 100 m (¥ † 50 m)Edge separation a‡ 2.500 µs
Reference mark signal1)
Pulse width 90° elec. or ungated (only when without interpolation) or 270° elec.
Fault indication1)
through fault detection signal ¥ or, in addition, Ua1/Ua2 high impedance
Power supply5 V ± 5% 3)‡ 0.500 µsCurrent consumption† 90 mA
Operating temperature Storage temperature
0 °C to 70 °C –30 °C to 80 °C
Vibration 50 to 2000 Hz Shock 11 ms
† 10 m/s2 † 300 m/s2ProtectionIP 65Weight0.7 kg« TTL (clocked)‡ 0.075 µs‡ 0.175 µs† 120 mA
Bold: These preferred versions are available on short notice Adjustable 2) The actual input frequency can be up to 5 % lower. Exceeding this limit results in failure 3) Not including the current consumption of the encoder (see the corresponding brochure) and without output load (80 mA with recommended input circuitry) 1)
Product Information for Series EXE 600
10/2006
Page4of 4
Open in the PDF
The text of page 4, from the PDF itself
Electrical Connection
Connecting cable or adapter cable with M23 connector (male) 9-pin
M23 connecting cable 12-pin, ¬ 8 mm Complete Id. Nr. 298 399-xx With one connector Id. Nr. 309 777-xx
Cable and connector 9-pin See HEIDENHAIN catalogs for digital readout and length gauges as well as product Information sheets for the respective encoders
Cable only [4(2x0.14mm2) + (4x0.5 mm2)] Id. Nr 244 957-01 Connector (female) 12-pin Id. Nr. 291 697-05
EXE input – » 11 µAPP 9-pin Flange socket M23
Power supplyIncremental signals34Housing9125678UP0VExternal shieldInside shieldI1+I1–I2+I2–I0+I0–BrownWhite–White/ BrownGreenYellowBlueRedGrayPink
UP = power supply voltage Vacant pins or wires must not be used!
Shield on housing Color assignment applies only to extension cable.
Output of EXE – « TTL 12-pin M23 flange socket
12-pin M23 connectorPower supplyIncremental signalsOther signals12210115681347/9UPSensor 5V0VSensor 0VUa1Ua2£Ua0¤¥UaSVacantBrown/ GreenBlueWhite/ GreenWhiteBrownGreenGrayPinkRedBlackViolet/Yellow
Shield on housing; UP = power supply voltage Sensor: The sensor line is connected internally with the corresponding power line
For more information
- Product overview: Interface Electronics DR. JOHANNES HEIDENHAIN GmbH Dr.-Johannes-Heidenhain-Straße 5 83301 Traunreut, Germany { +49 (86 69) 31-0 | +49 (86 69) 50 61 E-Mail: info@heidenhain.de www.heidenhain.de 598 010-21 · 10 · 10/2006 · F&W · Printed in Germany · Subject to change without notice