Manual · Heidenhain
Interpolation and Digitizing Electronics
Manual19 pagesPDF 1.1 MB
Catalog of Heidenhain EXE and IBV interpolation and digitizing electronics, including the EXE 602E, EXE 610C and EXE 650B.
Covers · 3 models
The models it covers
Summary
What is in it
Heidenhain's catalog of interpolation and digitizing electronics, which interpolate the sinusoidal signals of linear, rotary and angle encoders and convert them to square-wave pulses. It explains measuring signal processing, input frequency, edge separation and connection recommendations, then gives model overviews, mechanical and electrical data, cable lengths and pin layouts for the EXE 600 series (EXE 602E, 610C, 612, 650B, 660B), the EXE 900 series with built-in power supply and the IBV 600 series for 1 VPP signals.
Its parts
- Measuring Signal Processing
- Input Frequency fi
- Edge Separation a
- Connection Recommendations
- EXE 600 Series
- EXE 900 Series
- IBV 600 Series
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
HEIDENHAIN catalog of interpolation and digitizing electronics, which turn sinusoidal encoder signals into TTL square-wave pulses. It covers the EXE 600 series (EXE 602E, EXE 610C, EXE 612, EXE 650B, EXE 660B), the EXE 900 series with a built-in 85 to 265 V AC supply, and the IBV 600 series for 1 VPP signals. For each series it gives model overviews, mechanical and electrical data, cable lengths, pin layouts and connecting cable part numbers, plus general advice on signal processing, edge separation and cabling.
- Device
- EXE 600 series interpolation and digitizing electronics with one input for 11 µAPP linear or angle encoders p. 8
- Input
- 9-pin input for 11 µAPP sinusoidal signals (I1, I2: 7 to 16 µAPP; I0: 2 to 8.5 µA) p. 10, 11
- Output
- TTL square-wave Ua1, Ua2 and their inverted signals per RS-422, plus reference pulse Ua0, on a 12-pin male flange socket p. 10, 11
- Power supply
- 5 V ± 5%, supplied by the subsequent electronics p. 8, 10
- Protection
- IP 65 (IEC 529) p. 9
- Weight
- Approx. 0.7 kg p. 9
- EXE 602E
- EXE 602E: without interpolation or 5-fold; non-clocked output p. 2
- EXE 610C
- EXE 610C: 5-fold or 10-fold interpolation; 2 MHz clock frequency p. 2
- Fault-detection pulse
- EXE 602E: 250 µs or 40 ms, switchable; other EXE 6xx: 20 ms p. 10
- Reference pulse width
- Standard 90° el., switchable to 270° el. with interpolation, or to non-gated without interpolation p. 10
- Tristate
- Ua1 and Ua2 outputs can be switched to high impedance by the fault signal; inactive as standard p. 10
- Cable lengths
- Input max. 30 m (100 ft) with HEIDENHAIN cable at an encoder current limit of 120 mA (EXE 612: 10 m); output max. 50 m (164 ft) p. 11
- Output cables
- 12-pin cable complete Id.-Nr. 298 399-xx; with one female connector 309 777-xx; cable only 244 957-01; 12-pin female connector 291 697-05 p. 11
- Encoder cable
- HEIDENHAIN cable or double-shielded cable [3 (2 x 0.14 mm2) + (2 x 1.0 mm2)] from an 11 µAPP encoder to the EXE p. 7
What this manual walks you through
- Choosing a model by interpolation, clock frequency and number of encoder inputs p. 2
- How interpolation and digitizing of encoder signals work p. 4
- Working out the permissible traversing or shaft speed from the input frequency p. 5
- Matching the edge separation to the subsequent electronics p. 6
- Cabling, shielding and keeping cables away from interference p. 7
- Recommended input circuitry of the subsequent electronics p. 11
- Pin layout of the 12-pin output socket p. 11
- EXE 900 and IBV 600 series data and connections p. 12, 16
Good to know
- Keep EXE connecting cables at least 0.1 m (4 in.) from sources of interference and 0.2 m (8 in.) from inductors. p. 7
- The edge separation can reach its minimum even when the encoder is nearly still, for example from vibration. p. 6
- Allow a safety margin of at least 20 ns + 0.2 ns/m for transit time over the output cable. p. 6
- On a painted surface, make metallic contact through the EXE grounding screw. p. 7
- All outputs may be shorted to 0 V only briefly; one output is permanently short-circuit proof below 25° C (77° F). p. 10
Questions this manual answers
What is the difference between the EXE 602E and EXE 610C?
The EXE 602E works without interpolation or at 5-fold with non-clocked output; the EXE 610C offers 5-fold or 10-fold interpolation with a 2 MHz clock. p. 2
What power supply does an EXE 600 unit need?
5 V ± 5%, which the subsequent electronics must provide. p. 8, 10
How long can the output cable of an EXE 600 be?
Up to 50 m (164 ft) with HEIDENHAIN cable and the recommended input circuitry, or 20 m (66 ft) at a minimum edge separation of 0.1 µs or 0.125 µs. p. 11
What is the part number of the EXE 600 output cable?
The complete 12-pin cable with female and male connectors is Id.-Nr. 298 399-xx; with one female connector it is Id.-Nr. 309 777-xx. p. 11
How is the maximum traversing speed worked out for an EXE?
v [m/min] = p × fi × 6 × 10-2, with p the grating period in µm and fi the maximum input frequency of the EXE in kHz. p. 5
The whole text · 2 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file