Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 1 of 2

Interpolation and Digitizing Electronics, pages 1 to 10

Pages 1 to 10 of 19

The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Heidenhain EXE 602, Heidenhain EXE 610 C and Heidenhain EXE 650 B

Page 1 read from a scan by OCR; it may hold reading errors

HEIDENHAIN

Interpolation and Digitizing Electronics

Page 2

Overview

EXE Type: input signals » 11 µAPP

Model

Interpolation

Clock frequency Encoder fT inputs

Power supply

Specifications see page

EXE 602E

Without and 5-fold

Non-clocked

1

5V ± 5%

8

EXE 610C

5-fold or 10-fold

2 MHz

1

EXE 612

5-fold or 10-fold

8 MHz

1

EXE 650B

25-fold

8 MHz

1

Primary-clocked power supply 85 to 265 V

12

5V ± 5%

16

50-fold

IBV Type: input signals » 1 VPP

2

EXE 660B

25-fold, 50-fold, 100-fold, 200-fold or 400-fold

20 MHz

1

EXE 914

25-fold

8 MHz

1

EXE 922

Without,

Non-clocked

2

5-fold or 10-fold

2 MHz

EXE 924

25-fold

8 MHz

2

EXE 932

Without,

Non-clocked

3

5-fold or 10-fold

2 MHz

EXE 934

25-fold

8 MHz

3

EXE 935

50-fold

8 MHz

3

IBV 600

Without

Non-clocked

1

IBV 606

2-fold

Non-clocked

1

IBV 610

5-fold or 10-fold

8 MHz

1

IBV 650

50-fold

8 MHz

1

IBV 660B

25-fold, 50-fold, 100-fold, 200-fold or 400-fold

20 MHz

1

Page 3

Contents Page General Information Measuring Signal Processing

4

Input Frequency fi

5

Edge Separation a

6

Connection Recommendations

7

EXE 600 Series

8

EXE 900 Series

12

IBV 600 Series

16

Specifications

3

Page 4

Measuring Signal Processing

HEIDENHAIN linear, rotary and angle encoders operate on the principle of photoelectrically scanning very fine gratings. These encoders normally produce sinusoidal scanning signals with levels of approximately 11 µAPP (current signals) or 1 VPP (voltage signals). The subsequent electronics first interpolates the scanning signals and then converts them into square-wave pulses (digitizing). The interpolation and digitizing circuitry is either integrated in the NC control (e.g. a HEIDENHAIN TNC) or display unit (e.g. an ND or POSITIP from HEIDENHAIN), or is available as a separate unit of the EXE type (for current signals I1, I2 and I0) or IBV type (for voltage signals A, B and R).

Within one signal period, each of the four signal edges of Ua1 and Ua2 can be used as a counting pulse. The distance between two subsequent edges of Ua1 and Ua2 is one measuring step. For example, after 5-fold interpolation this distance is 1/20 of a grating period (see the following example). Example: With 5-fold interpolation of the measuring signal and the usual 4-fold evaluation of the square-wave pulses in the subsequent electronics, a linear encoder with a grating period of 20 µm can provide a measuring step of 1 µm.

EXE and IBV units deliver two square-wave pulse trains Ua1 and Ua2 plus a reference pulse Ua0.

Signal period 360° el.

Ua1

I1, A

0

0

Ua2

I2, B

0

0

90° el.

I0, R

Ua0

Reference mark signal

Reference pulse

0

0

Scanning signals

Measuring step

Phase shift

EXE or IBV interpolation and digitizing electronics

Measuring signals after 5-fold interpolation and digitizing

The inverse signals Ua1, Ua2 and Ua0 have been omitted from the illustration to improve clarity.

4

Page 5

Input Frequency fi

The permissible traversing speed of linear encoders, and the permissible shaft speed of rotary and angle encoders, is limited by the mechanically and electrically permissible traversing or shaft speed (see encoder data sheets). The electrically permissible output frequency of the encoder is usually higher than the permissible input frequency of the EXE or IBV. For this reason, the electrically permissible traversing speed v or shaft speed n depends directly on the maximum input frequency fi of the EXE or IBV unit (see Overview). Exception: IBV 600 and IBV 606; in this case the –3dB limit frequency of the encoder cannot be exceeded.

Electrically permissible traversing speed v with linear encoders: v [m/min] = p × fi × 6 × 10-2 p signal or grating period of the linear encoder in µm fi maximum input frequency of the EXE/IBV in kHz

Electrically permissible shaft speed n with rotary encoders: n [rpm] = fi × 6 × 104 z fi maximum input frequency of the EXE/IBV in kHz Z line count of encoder

Input frequency fi of the interpolation and digitizing electronics and highest possible traversing speeds v with incremental linear encoders

Input frequency fi of the interpolation and digitizing electronics and highest possible shaft speeds n with incremental rotary encoders

Shaft speed n [rpm] z

00 kH

In pu tf re z qu en cy 5 z kH 0 z

20 kH 50 z kH z

0 kH 10 60 z z z kH kH z

10 z kH 6. 25 z

.5 z kH kH

20

20 z

100

10 kH z kH kH

40

25 z

25 kH kH

200

6.

10

12

60 z kH

40 z

300

.5

4 z kH

5 2 kH z z

20

12

10 kH

20

600 500

25

30

0 kH

1000

20

50

60 50 z kH kH

0

0

2000 z

60

60

3000 kH

100

4000 0

200 z kH

300

0

400

50

6000

10

Traversing speed v [m/min]

600

40

Signal period or grating period p [µm]

50 500

1 000

2 000

4 000

8 000 16 000 32 000

Line count z

5

Page 6

Edge Separation a

As a rule, the electronics subsequent to the EXE can only evaluate signals whose edge separation between any two successive square-wave signals Ua1 and Ua2 does not fall below a certain value. Minimum edge separation amin: the shortest time span between two successive edges of EXE output signals. The minimum edge separation is listed in the model overviews. The edge separation may reach the minimum permissible value even when the encoders are nearly motionless (for example due to vibration). For this reason, the subsequent electronics must be able to process the selected minimum edge separation correctly, regardless of the input frequency of the EXE or IBV. You should calculate a safety margin of at least 20 ns + 0.2 ns/m for differences in transit time over the transmission distances, taking into account the length of the output cable.

Ua1 0

Ua2 0

6

Edge separation a

Clocked EXE/IBV In the case of electronics with clocked output signals, the maximum input frequency and the edge separation are determined by the clock frequency fT. The indicated values for the maximum input frequency thus represent an absolute functional limit. The edge separation can assume whole-number multiples of amin without dropping below the minimum value of amin. To adjust the edge separation to the subsequent electronics, the time span between two successive edges can be varied. The maximum permissible input frequency changes correspondingly.

Non-clocked EXE/IBV For electronics with non-clocked output signals, the minimum edge separation amin resulting from the maximum permissible input frequency is listed in the specifications. If the input frequency is reduced, the edge separation increases correspondingly.

Page 7

Connection Recommendations

Connecting cable Ž Encoder » 11 µAPP to EXE: Use recommended HEIDENHAIN cable or double-shielded cable [3 (2 x 0.14 mm2) + (2 x 1.0 mm2)]. Ž Encoder » 1 VPP to IBV: Use recommended HEIDENHAIN cable or single-shielded cable [4 (2 x 0.14 mm2) + (4 x 0.5 mm2)]. Ž EXE/IBV to subsequent electronics: Use recommended HEIDENHAIN cable or single-shielded cable [4 (2 x 0.14 mm2) + (4 x 0.5 mm2)]. Ž Use original HEIDENHAIN connecting elements or metal connecting elements, preferably with insulating plastic covering.

Shielding The housings of the connecting elements, terminal boxes and EXE or IBV must be connected to each other via the outer cable shield. The cable shielding has the function of a potential compensating line. If compensating currents are to be expected within the total setup, a separate potential compensating line must be provided (> 6 mm2 Cu). Contact to the machine chassis is normally made at the machine mounting screws, on sealed linear encoders at the mounting block and scale unit. If the EXE or IBV unit is mounted on painted surfaces, provide metallic contact via the EXE/IBV grounding screw.

Cable configuration When configuring the cable, take into account possible influences from sources of electromagnetic interference such as power cables, contactors, motors, magnetic valves, or stray magnetic fields from switch-mode power supplies. To ensure trouble-free operation, maintain a minimum clearance of 0.1 m (4 in.) between EXE/IBV connecting cables and sources of interference, and at least 0.2 m (8 in.) to inductors. If a cable train contains connecting elements, take steps to prevent possible contact between the connector housings and other metal parts. Use original HEIDENHAIN cables and connecting elements with insulated housings.

Permissible bending radii for connecting cable without metal armor tubing

Permissible bending radii for connecting cable with metal armor tubing

Cable

Cable

Dia. 8 mm (0.31 in.) Dia. 6 mm (0.24 in.) Dia. 4.5 mm (0.18 in.)

Permissible bending radius for Frequent flexing

Rigid configuration

R ‡ 100 mm (4 in.) R ‡ 75 mm (3 in.) R ‡ 50 mm (2 in.)

R ‡ 40 mm (1.6 in.) R ‡ 20 mm (0.8 in.) R ‡ 10 mm (0.4 in.)

Permissible bending radius for

Dia. 10 mm (0.39 in.) Dia. 14 mm (0.55 in.)

Frequent flexing

Rigid configuration

R ‡ 75 mm (3 in.) R ‡ 100 mm (4 in.)

R ‡ 35 mm (1.4 in.) R ‡ 50 mm (2 in.)

Sources of interference

7

Page 8

EXE Interpolation and Digitizing Electronics Input: » 11 µAPP Output: « TTL

Model

Interpolation

Input frequency fi

EXE 602E

Adjustable

EXE 600 Series – Model Overview

Without

50

5-fold

25

5-fold

50 kHz 25 kHz 12.5 kHz 6.25 kHz

10-fold

50 kHz 25 kHz 12.5 kHz 6.25 kHz

5-fold

100 100 50 25 kHz kHz kHz kHz

10-fold

100 100 50 25 kHz kHz kHz kHz

50-fold

40 20 10 5 kHz kHz kHz kHz

8 MHz

0.125 µs 0.25 µs 0.5 µs 1 µs

25-fold

60 40 20 10 kHz kHz kHz kHz

8 MHz

0.125 µs 0.25 µs 0.5 µs 1 µs

25-fold

50 kHz 20 MHz 50 kHz 25 kHz 12.5 kHz

0.1 0.2 0.4 0.8

µs µs µs µs

50-fold

50 kHz 25 kHz 12.5 kHz 6.25 kHz

0.1 0.2 0.4 0.8

µs µs µs µs

100-fold

25 kHz 12.5 kHz 6.25 kHz 3.12 kHz

0.1 0.2 0.4 0.8

µs µs µs µs

200-fold

12.5 kHz 6.25 kHz 3.12 kHz 1.56 kHz

0.1 0.2 0.4 0.8

µs µs µs µs

400-fold

6.25 kHz 3.12 kHz 1.56 kHz 0.78 kHz

0.1 0.2 0.4 0.8

µs µs µs µs

EXE 610C Adjustable

The EXE 600 series features one input for linear or angle encoders with 11 µAPP sinusoidal output signals. These EXE units deliver TTL-compatible square-wave signals over a flange socket.

EXE 612 Adjustable

The necessary 5 V ± 5 % power supply must be provided by the subsequent electronics.

EXE 650B

Adjustable

EXE 660B

8

Clock Minimum frequency edge sepafT ration a kHz Nonclocked kHz 2 MHz

8 MHz

2.5

µs

0.5

µs

1 2 4 8

µs µs µs µs

0.5 1 2 4

µs µs µs µs

0.25 µs 0.5 µs 1 µs 2 µs 0.125 µs 0.25 µs 0.5 µs 1 µs

Page 9

EXE 600 Series

# Mechanical Data Weight

Approx. 0.7 kg

Protection (IEC 529)

IP 65

Operating temperature Storage temperature

–30 to 70° C (32 to 158° F) –30 to 80° C (–22 to 176° F)

Vibration (50 to 2000 Hz) Shock (11 ms)

† 10 m/s2 † 300 m/s2

Dimensions in mm/inches

9

Page 10

# Electrical Data

EXE 600 Series

Power supply

UP = 5 V ± 5 %

Current consumption (without encoder light source or output load)

EXE 602E EXE 610C EXE 612 EXE 650B EXE 660B typ. 55 mA, typ. 65 mA, typ. 65 mA, typ. 120 mA, typ. 100 mA, max. 90 mA max. 100 mA max. 100 mA max. 160 mA max. 120 mA

With the recommended input circuitry for the subsequent electronics, the maximum permissible current consumption increases by D I = 80 mA. Input signals

Sinusoidal scanning signals, preferably from HEIDENHAIN linear and angle encoders.

360° el. I1

0 90° el. 0

0

Output signals

I1, I2: 7 to 16 µAPP I0: 2 to 8.5 µA

Signal levels

Input frequency fi: see Model Overview I2

I0

Incremental signals: Square-wave pulse trains Ua1 and Ua2 and their inverted pulse trains ¢ and £ (according to RS-422). Edge separation a:

see Model Overview

Reference signal: Square-wave pulse Ua0 and its inverted pulse ¤. Width: EXE with interpolation Standard 90° el., switchable to 270° el.

EXE without interpolation Standard 90° el., switchable to non-gated (e > a/2) Fault-detection signal: Square-wave pulse ¥ Duration: EXE 6xx ts ‡ 20 ms EXE 602E ts ‡ 250 µs or ts ‡ 40 ms (switchable) Tristate: With ¥ = Low, outputs for Ua1, Ua2 and ¢, £ can be switched to high impedance. Standard setting: Tristate inactive, can be switched to active Signal levels TTL-compatible UHigh ‡ 2.5 V at –IHigh † 20 mA ULow † 0.5 V at ILow † 20 mA

10

Load capacity

–IHigh † 20 mA ILow † 20 mA CLoad † 1000 pF against 0 V Temporary short circuit of all outputs against 0 V permissible. One output permanently short-circuit proof when T0 < 25° C (77° F).

Switching times

With 1 m (3.3 ft) cable and recommended input circuitry of subsequent electronics: Rise time t+ = typ. 10 ns, max. 30 ns Fall time t– = typ. 10 ns, max. 30 ns