Page 11

Recommended input circuitry of subsequent electronics

+5V Ua Z0

Ua

AM 26 LS 32 MC 3486

RS - 422 DIN 66 259

SN75ALS193 SN75ALS195

+5V R1 R2

UaS

AM 26 LS 32 MC 3486

R1

SN75ALS193 SN75ALS195

R1 = 4.7 kW R2 = 1.8 kW Z0 = 120 W

Permissible cable lengths

Input

EXE 6xx: max. 30 m (100 ft) with HEIDENHAIN cable [3 (2 x 0.14 mm2) + (2 x 1.0 mm2)] when Iencoder † 120 mA EXE 612: max. 10 m (33 ft)

Output

Max. 50 m (164 ft) with HEIDENHAIN cable [4 (2 × 0.14 mm2) + (4 × 0.5 mm2)] and recommended input circuitry of subsequent electronics. The supply voltage level, measured at the cable end via the sensor line, must be maintained. Max. 20 m (66 ft) with minimum edge separation a = 0.1 µs or 0.125 µs

Pin layout – Output (Colors valid for HEIDENHAIN cable)

12-pin flange socket (male)

5

6

8

1

3

4

12

10

Ua1

¢

Ua2

£

Ua0

¤

5V (UP)

0V (UN)

Brown

Green

Gray

Pink

Red

Black

Brown/ green

White/ green

* The sensor line is connected internally to the supply line.

2

11

9

7

/

¥

1)

Violet

Yellow

0V Vacant 5V Sensor* Sensor* Blue

White

/

IEC742 EN 50178 Shield on housing

HEIDENHAIN connecting elements EXE 600

Output 12-pin « TTL

Cable and connector 9-pin, see HEIDENHAIN catalogs “Rotary Encoders,” “Angle Encoders,” ”Exposed Linear Encoders,” ”Sealed Linear Encoders”

9-pin » 11 µAPP

Input

« »

Cable 12-pin Complete with connector (female) and connector (male), Id.-Nr. 298 399-xx

With one connector (female) Id.-Nr. 309 777-xx

Cable only PUR [4(2 × 0.14 mm2) + (4 × 0.5 mm2)] Id.-Nr. 244 957-01

Connector (female) 12-pin Id.-Nr. 291 697-05

11

Page 12

EXE Interpolation and Digitizing Electronics Input: » 11 µAPP Output: « TTL The EXE 900 series features an integral primary-clocked power supply (85 to 265 V AC). Versions are available for one to a maximum of three incremental linear or angle encoders with sinusoidal output signals and a signal level of 11µAPP. The standard output signals of the EXE 900 series are TTL-compatible square-wave signals (one for each encoder connected).

Model

1

EXE 914

25-fold

60 40 20 10 kHz 8 MHz kHz kHz kHz

0.125 µs 0.25 µs 0.5 µs 1 µs

1 TTL Option: + 1 TTL +1»

2

EXE 922

Without

50 kHz Nonclocked

2.5

µs

5-fold

50 kHz 2 MHz 25 kHz 12.5 kHz 6.25 kHz

1 2 4 8

µs µs µs µs

1 TTL Option: + 1 TTL +1»

10-fold

50 kHz 25 kHz 12.5 kHz 6.25 kHz

0.5 1 2 4

µs µs µs µs

EXE 924

25-fold

60 40 20 10 kHz 8 MHz kHz kHz kHz

0.125 µs 0.25 µs 0.5 µs 1 µs

1 TTL Option: + 1 TTL +1»

EXE 932

See EXE 922

EXE 934

See EXE 924

EXE 935

50-fold

40 20 10 5 kHz 8 MHz kHz kHz kHz

0.125 µs 0.25 µs 0.5 µs 1 µs

1 TTL Option: + 1 TTL +1»

Additional flange sockets can be specified, providing one additional TTL signal for each encoder input. As a further option, the sinusoidal input signals can be output again.

3

12

Interpolation

Input frequency fi

Clock Minimum Outputs frequency edge sepa- per input fT ration a

Encoder inputs

Each input adjustable

EXE 900 Series – Model Overview

Page 13

EXE 900 Series

# Mechanical Data Weight

Approx. 5.0 kg

Protection (IEC 529)

IP 65

Operating temperature Storage temperature

–30 to 45° C (32 to 113° F) –30 to 80° C (–22 to 176° F)

Vibration (50 to 2000 Hz) Shock (11 ms)

† 10 m/s2 † 300 m/s2

Dimensions in mm/inches

13

Page 14

# Electrical Data

EXE 900 Series

Power supply

Incorporated primary-clocked power supply 85 to 265 V AC 48 to 62 Hz

Power consumption

Max. 15 VA

Input signals

Sinusoidal scanning signals, preferably from HEIDENHAIN linear and angle encoders.

360° el. I1

0 90° el. 0

0

Output signals

I2

Signal levels

I1, I2: 7 to 16 µAPP I0: 2 to 8.5 µA

Input frequency fi:

see Model Overview

Total current consumption of all connected encoders: max. 700 mA

I0

Incremental signals: Square-wave pulse trains Ua1 and Ua2 and their inverted pulse trains ¢ and £ (according to RS-422). Edge separation a:

see Model Overview

Reference signal: Square-wave pulse Ua0 and its inverted pulse ¤. Width: EXE with interpolation Standard 90° el., switchable to 270° el. EXE without interpolation Standard 90° el., switchable to non-gated (e > a/2) Fault-detection signal: Square-wave pulse ¥ (UaS is also provided). Duration: ts ‡ 20 ms Tristate: With ¥ = Low, outputs for Ua1, Ua2 and ¢, £ can be switched to high impedance. Standard setting: Tristate inactive, can be switched to active Signal levels TTL-compatible UHigh ‡ 2.5 V at –IHigh † 20 mA ULow † 0.5 V at ILow † 20 mA

14

Load capacity

–IHigh † 20 mA ILow † 20 mA CLoad † 1000 pF against 0 V Temporary short circuit of all outputs against 0 V permissible. One output permanently short-circuit proof when T0 < 25° C (77° F).

Switching times

With 1 m (3.3 ft) cable and recommended input circuitry of subsequent electronics: Rise time t+ = typ. 10 ns, max. 30 ns Fall time t– = typ. 10 ns, max. 30 ns

Page 15

Recommended input circuitry of subsequent electronics Square-wave signals

+5V Ua Z0

Ua

SN 75 ALS 193

AM 26 LS 32 MC 3486

RS - 422 DIN 66 259

SN 75 ALS 195

Z0 = 120 W

Sinusoidal signals zulässige Kabellängen see encoder specifications max. 30 m with HEIDENHAIN cable [3 (2 × 0.14 mm2) + (2 × 1.0 mm2)]

Input TTL output max. 50 m (164 ft) with HEIDENHAIN cable [25 x 0.34 mm2] and recommended input circuitry of subsequent electronics, max. 20 m (66 ft) with minimum edge separation a = 0.125 µs

»output max. 30 m (100 ft) with HEIDENHAIN cable [3 (2 x 0.14 mm2) + (2 x 1.0 mm2)]

Pin layout – Output (Colors valid for HEIDENHAIN cable)

25-pin flange socket (female)

X1 B2

A1

A2

C1

C2

X2 B3

B4

A3

A4

C3

C4

B5

B6

X3 A5

A6

C5

C6

B7

B8

A7

A8

* C7

A9

C8

C9

*UaN Reference potential for signals.

White/black

Brown/red

White/red

Brown/blue

White/blue

Pink/brown

White/pink

Gray/brown

White/gray

Yellow/brown

White/yellow

Brown/green

White/green

Red/blue

Gray/pink

Violet

Black

Red

Blue

Pink

Gray

Yellow

Green

Brown

White

¢ Ua1 £ Ua2 ¤ Ua0 ¥ UaS ¢ Ua1 £ Ua2 ¤ Ua0 ¥ UaS ¢ Ua1 £ Ua2 ¤ Ua0 ¥ UaS UaN

Shield on housing

HEIDENHAIN connecting elements EXE 900 9-pin » 11 µAPP

Output

« » « » « »

25-pin« TTL

Cable and connector 9-pin, see HEIDENHAIN catalogs “Rotary Encoders,” “Angle Encoders,” ”Exposed Linear Encoders,” ”Sealed Linear Encoders”

9-pin » 11 µAPP

Input

Cable 9-pin Complete with connector (female) and connector (male) Id.-Nr. 309 773-xx

Cable 25-pin Complete with connector (male) and connector (female) Id.-Nr. 207 620-xx

With one connector (male) Id.-Nr. 209 009-xx

Option: « TTL output assembly (for all encoder inputs) Id.-Nr. 284 477-xx

Option: » 11 µAPP output assembly (for each encoder input) Id.-Nr. 237 280-xx

Cable only PUR [25 × 0.34 mm2] Id.-Nr. 209 991-01

Connector (female) 12-pin Id.-Nr. 207 985-01

15

Page 16

IBV Interpolation and Digitizing Electronics Input: » 1 VPP Output: « TTL The IBV 600 series features one input for incremental linear or angle encoders with sinusoidal output signals and a signal level of 1 VPP.

Model

Clock Minimum frequency edge sepafT ration a

Without 600 kHz Nonclocked

0.2

IBV 606

2-fold

500 kHz Nonclocked

0.15 µs

IBV 610

5-fold

200 100 50 25 kHz 8 MHz kHz kHz kHz

0.25 µs 0.5 µs 1 µs 2 µs

10-fold

200 100 50 25 kHz kHz kHz kHz

0.125 µs 0.25 µs 0.5 µs 1 µs

IBV 650

50-fold

40 20 10 5 kHz 8 MHz kHz kHz kHz

0.125 µs 0.25 µs 0.5 µs 1 µs

IBV 660B

25-fold

100 50 25 12.5 kHz 20 MHz kHz kHz kHz

0.1 0.2 0.4 0.8

µs µs µs µs

50-fold

50 kHz 25 kHz 12.5 kHz 6.25 kHz

0.1 0.2 0.4 0.8

µs µs µs µs

100-fold

25 kHz 12.5 kHz 6.25 kHz 3.12 kHz

0.1 0.2 0.4 0.8

µs µs µs µs

200-fold

12.5 kHz 6.25 kHz 3.12 kHz 1.56 kHz

0.1 0.2 0.4 0.8

µs µs µs µs

400-fold

6.25 kHz 3.12 kHz 1.56 kHz 0.78 kHz

0.1 0.2 0.4 0.8

µs µs µs µs

Adjustable

The necessary 5 V ± 5 % power supply must be provided by the subsequent electronics.

16

Input frequency fi

IBV 600

IBV 600 models deliver TTL-compatible square-wave output signals over a flange socket. The IBV 606 provides output signals at two flange sockets simultaneously. The connections inside the IBV 606 can be changed such that either one flange socket or both flange sockets deliver sinusoidal voltage signals with a signal level of 1 VPP instead of square-wave output signals.

Interpolation

Adjustable

IBV 600 Series – Model Overview

µs

Page 17

IBV 600 Series

# Mechanical Data Weight

Approx. 0.7 kg

Protection (IEC 529)

IP 65

Operating temperature Storage temperature

–30 to 70° C (32 to 158° F) –30 to 80° C (–22 to 176° F)

Vibration (50 to 2000 Hz) Shock (11 ms)

† 10 m/s2 † 300 m/s2

Dimensions in mm/inches

IBV 606

17

Page 18

# Electrical Data

IBV 600 Series

Power supply

UP = 5 V ± 5 %

Current consumption (Without encoder light source or output load)

IBV 600 IBV 610 IBV 650 IBV 660 B typ. 50 mA, typ. 65 mA, typ. 120 mA, typ. 100 mA, max. 85 mA max. 110 mA max. 160 mA max. 120 mA

With the recommended input circuitry for the subsequent electronics, the maximum permissible current consumption increases by DI = 80 mA. Input signals

Output signals

Sinusoidal scanning signals, preferably from HEIDENHAIN linear and angle encoders. Signal levels

A, B: 0.6 to 1.2 VPP R: 0.2 to 0.85 V

Input frequency fi:

see Model Overview

Incremental signals: Square-wave pulse trains Ua1 and Ua2 and their inverted pulse trains ¢ and £ (according to RS-422). Edge separation a:

see Model Overview

Reference signal: Square-wave pulse Ua0 and its inverted pulse ¤. Width: IBV with interpolation Standard 90° el., switchable to 270° el. IBV without interpolation Standard 90° el., switchable to non-gated (e > a/2) Fault-detection signal: Square-wave pulse ¥ Duration: ts ‡ 20 ms Tristate: With ¥ = Low, outputs for Ua1, Ua2 and ¢, £ can be switched to high impedance. Standard setting: Tristate inactive, can be switched to active Signal levels TTL-compatible UHigh ‡ 2.5 V at – IHigh † 20 mA ULow † 0.5 V at ILow † 20 mA

18

Load capacity

–IHigh † 20 mA ILow † 20 mA CLoad † 1000 pF against 0 V Temporary short circuit of all outputs against 0 V permissible. One output permanently short-circuit proof when T0 < 25° C (77° F).

Switching times

With 1 m (3.3 ft) cable and recommended input circuitry of subsequent electronics: Rise time t+ = typ. 10 ns, max. 30 ns Fall time t– = typ. 10 ns, max. 30 ns

Page 19

Recommended input circuitry of subsequent electronics

+5V Ua Z0

Ua

AM 26 LS 32 MC 3486

RS - 422 DIN 66 259

SN75ALS193 SN75ALS195

+5V R1 R2

UaS

AM 26 LS 32 MC 3486

R1

SN75ALS193 SN75ALS195

R1 = 4.7 kW R2 = 1.8 kW Z0 = 120 W

Permissible cable lengths

Input

UP > 4.75 V: max. 30 m (100 ft) with HEIDENHAIN cable [4 (2 × 0.14 mm2) + (4 × 0.5 mm2)] when Iencoder † 120 mA UP > 4.9 V: max. 60 m (200 ft)

Output

Pin layout, Output (Colors valid for HEIDENHAIN cable)

max. 50 m (164 ft) with HEIDENHAIN cable [4 (2 × 0.14 mm2) + (4 × 0.5 mm2)] and recommended input circuitry of subsequent electronics. The supply voltage level, measured at the cable end via the sensor line, must be maintained. Max. 20 m (66 ft) with minimum edge separation a † 0.125 µs 12-pin flange socket (male)

5

6

8

1

3

4

12

10

2

11

9

7

/

Ua1

¢

Ua2

£

Ua0

¤

5 V* (UP)

0 V* (UN)

5V Sensor

0V Sensor

Vacant

¥

Vacant

Brown

Green

Gray

Pink

Red

Black

Brown/ green

White/ green

Blue

White

/

Violet

Yellow

IEC742 EN 50178 Shield on housing

The sensor line is connected internally to the supply line *With IBV 606: Power supply at X2 only. HEIDENHAIN connecting elements IBV 600

12-pin « TTL

Cable and connector 12-pin, see HEIDENHAIN catalogs “Rotary Encoders,” “Angle Encoders,” ”Exposed Linear Encoders,” ”Sealed Linear Encoders”

Output

12-pin » 1 VPP

Input

« »

Only IBV 606

Cable 12-pin Complete with connector (female) and connector (male) Id.-Nr. 298 399-xx

With one connector (female) Id.-Nr. 309 777-xx

Cable only PUR [4(2 × 0.14 mm2) + (4 × 0.5 mm2)] Id.-Nr. 244 957-01

Connector (male) 12-pin Id.-Nr. 291 697-05

19