Page 11
Recommended input circuitry of subsequent electronics
+5V Ua Z0
Ua
AM 26 LS 32 MC 3486
RS - 422 DIN 66 259
SN75ALS193 SN75ALS195
+5V R1 R2
UaS
AM 26 LS 32 MC 3486
R1
SN75ALS193 SN75ALS195
R1 = 4.7 kW R2 = 1.8 kW Z0 = 120 W
Permissible cable lengths
Input
EXE 6xx: max. 30 m (100 ft) with HEIDENHAIN cable [3 (2 x 0.14 mm2) + (2 x 1.0 mm2)] when Iencoder † 120 mA EXE 612: max. 10 m (33 ft)
Output
Max. 50 m (164 ft) with HEIDENHAIN cable [4 (2 × 0.14 mm2) + (4 × 0.5 mm2)] and recommended input circuitry of subsequent electronics. The supply voltage level, measured at the cable end via the sensor line, must be maintained. Max. 20 m (66 ft) with minimum edge separation a = 0.1 µs or 0.125 µs
Pin layout – Output (Colors valid for HEIDENHAIN cable)
12-pin flange socket (male)
5
6
8
1
3
4
12
10
Ua1
¢
Ua2
£
Ua0
¤
5V (UP)
0V (UN)
Brown
Green
Gray
Pink
Red
Black
Brown/ green
White/ green
* The sensor line is connected internally to the supply line.
2
11
9
7
/
¥
1)
Violet
Yellow
0V Vacant 5V Sensor* Sensor* Blue
White
/
IEC742 EN 50178 Shield on housing
HEIDENHAIN connecting elements EXE 600
Output 12-pin « TTL
Cable and connector 9-pin, see HEIDENHAIN catalogs “Rotary Encoders,” “Angle Encoders,” ”Exposed Linear Encoders,” ”Sealed Linear Encoders”
9-pin » 11 µAPP
Input
« »
Cable 12-pin Complete with connector (female) and connector (male), Id.-Nr. 298 399-xx
With one connector (female) Id.-Nr. 309 777-xx
Cable only PUR [4(2 × 0.14 mm2) + (4 × 0.5 mm2)] Id.-Nr. 244 957-01
Connector (female) 12-pin Id.-Nr. 291 697-05
11
Page 12
EXE Interpolation and Digitizing Electronics Input: » 11 µAPP Output: « TTL The EXE 900 series features an integral primary-clocked power supply (85 to 265 V AC). Versions are available for one to a maximum of three incremental linear or angle encoders with sinusoidal output signals and a signal level of 11µAPP. The standard output signals of the EXE 900 series are TTL-compatible square-wave signals (one for each encoder connected).
Model
1
EXE 914
25-fold
60 40 20 10 kHz 8 MHz kHz kHz kHz
0.125 µs 0.25 µs 0.5 µs 1 µs
1 TTL Option: + 1 TTL +1»
2
EXE 922
Without
50 kHz Nonclocked
2.5
µs
5-fold
50 kHz 2 MHz 25 kHz 12.5 kHz 6.25 kHz
1 2 4 8
µs µs µs µs
1 TTL Option: + 1 TTL +1»
10-fold
50 kHz 25 kHz 12.5 kHz 6.25 kHz
0.5 1 2 4
µs µs µs µs
EXE 924
25-fold
60 40 20 10 kHz 8 MHz kHz kHz kHz
0.125 µs 0.25 µs 0.5 µs 1 µs
1 TTL Option: + 1 TTL +1»
EXE 932
See EXE 922
EXE 934
See EXE 924
EXE 935
50-fold
40 20 10 5 kHz 8 MHz kHz kHz kHz
0.125 µs 0.25 µs 0.5 µs 1 µs
1 TTL Option: + 1 TTL +1»
Additional flange sockets can be specified, providing one additional TTL signal for each encoder input. As a further option, the sinusoidal input signals can be output again.
3
12
Interpolation
Input frequency fi
Clock Minimum Outputs frequency edge sepa- per input fT ration a
Encoder inputs
Each input adjustable
EXE 900 Series – Model Overview
Page 13
EXE 900 Series
# Mechanical Data Weight
Approx. 5.0 kg
Protection (IEC 529)
IP 65
Operating temperature Storage temperature
–30 to 45° C (32 to 113° F) –30 to 80° C (–22 to 176° F)
Vibration (50 to 2000 Hz) Shock (11 ms)
† 10 m/s2 † 300 m/s2
Dimensions in mm/inches
13
Page 14
# Electrical Data
EXE 900 Series
Power supply
Incorporated primary-clocked power supply 85 to 265 V AC 48 to 62 Hz
Power consumption
Max. 15 VA
Input signals
Sinusoidal scanning signals, preferably from HEIDENHAIN linear and angle encoders.
360° el. I1
0 90° el. 0
0
Output signals
I2
Signal levels
I1, I2: 7 to 16 µAPP I0: 2 to 8.5 µA
Input frequency fi:
see Model Overview
Total current consumption of all connected encoders: max. 700 mA
I0
Incremental signals: Square-wave pulse trains Ua1 and Ua2 and their inverted pulse trains ¢ and £ (according to RS-422). Edge separation a:
see Model Overview
Reference signal: Square-wave pulse Ua0 and its inverted pulse ¤. Width: EXE with interpolation Standard 90° el., switchable to 270° el. EXE without interpolation Standard 90° el., switchable to non-gated (e > a/2) Fault-detection signal: Square-wave pulse ¥ (UaS is also provided). Duration: ts ‡ 20 ms Tristate: With ¥ = Low, outputs for Ua1, Ua2 and ¢, £ can be switched to high impedance. Standard setting: Tristate inactive, can be switched to active Signal levels TTL-compatible UHigh ‡ 2.5 V at –IHigh † 20 mA ULow † 0.5 V at ILow † 20 mA
14
Load capacity
–IHigh † 20 mA ILow † 20 mA CLoad † 1000 pF against 0 V Temporary short circuit of all outputs against 0 V permissible. One output permanently short-circuit proof when T0 < 25° C (77° F).
Switching times
With 1 m (3.3 ft) cable and recommended input circuitry of subsequent electronics: Rise time t+ = typ. 10 ns, max. 30 ns Fall time t– = typ. 10 ns, max. 30 ns
Page 15
Recommended input circuitry of subsequent electronics Square-wave signals
+5V Ua Z0
Ua
SN 75 ALS 193
AM 26 LS 32 MC 3486
RS - 422 DIN 66 259
SN 75 ALS 195
Z0 = 120 W
Sinusoidal signals zulässige Kabellängen see encoder specifications max. 30 m with HEIDENHAIN cable [3 (2 × 0.14 mm2) + (2 × 1.0 mm2)]
Input TTL output max. 50 m (164 ft) with HEIDENHAIN cable [25 x 0.34 mm2] and recommended input circuitry of subsequent electronics, max. 20 m (66 ft) with minimum edge separation a = 0.125 µs
»output max. 30 m (100 ft) with HEIDENHAIN cable [3 (2 x 0.14 mm2) + (2 x 1.0 mm2)]
Pin layout – Output (Colors valid for HEIDENHAIN cable)
25-pin flange socket (female)
X1 B2
A1
A2
C1
C2
X2 B3
B4
A3
A4
C3
C4
B5
B6
X3 A5
A6
C5
C6
B7
B8
A7
A8
* C7
A9
C8
C9
*UaN Reference potential for signals.
White/black
Brown/red
White/red
Brown/blue
White/blue
Pink/brown
White/pink
Gray/brown
White/gray
Yellow/brown
White/yellow
Brown/green
White/green
Red/blue
Gray/pink
Violet
Black
Red
Blue
Pink
Gray
Yellow
Green
Brown
White
¢ Ua1 £ Ua2 ¤ Ua0 ¥ UaS ¢ Ua1 £ Ua2 ¤ Ua0 ¥ UaS ¢ Ua1 £ Ua2 ¤ Ua0 ¥ UaS UaN
Shield on housing
HEIDENHAIN connecting elements EXE 900 9-pin » 11 µAPP
Output
« » « » « »
25-pin« TTL
Cable and connector 9-pin, see HEIDENHAIN catalogs “Rotary Encoders,” “Angle Encoders,” ”Exposed Linear Encoders,” ”Sealed Linear Encoders”
9-pin » 11 µAPP
Input
Cable 9-pin Complete with connector (female) and connector (male) Id.-Nr. 309 773-xx
Cable 25-pin Complete with connector (male) and connector (female) Id.-Nr. 207 620-xx
With one connector (male) Id.-Nr. 209 009-xx
Option: « TTL output assembly (for all encoder inputs) Id.-Nr. 284 477-xx
Option: » 11 µAPP output assembly (for each encoder input) Id.-Nr. 237 280-xx
Cable only PUR [25 × 0.34 mm2] Id.-Nr. 209 991-01
Connector (female) 12-pin Id.-Nr. 207 985-01
15
Page 16
IBV Interpolation and Digitizing Electronics Input: » 1 VPP Output: « TTL The IBV 600 series features one input for incremental linear or angle encoders with sinusoidal output signals and a signal level of 1 VPP.
Model
Clock Minimum frequency edge sepafT ration a
Without 600 kHz Nonclocked
0.2
IBV 606
2-fold
500 kHz Nonclocked
0.15 µs
IBV 610
5-fold
200 100 50 25 kHz 8 MHz kHz kHz kHz
0.25 µs 0.5 µs 1 µs 2 µs
10-fold
200 100 50 25 kHz kHz kHz kHz
0.125 µs 0.25 µs 0.5 µs 1 µs
IBV 650
50-fold
40 20 10 5 kHz 8 MHz kHz kHz kHz
0.125 µs 0.25 µs 0.5 µs 1 µs
IBV 660B
25-fold
100 50 25 12.5 kHz 20 MHz kHz kHz kHz
0.1 0.2 0.4 0.8
µs µs µs µs
50-fold
50 kHz 25 kHz 12.5 kHz 6.25 kHz
0.1 0.2 0.4 0.8
µs µs µs µs
100-fold
25 kHz 12.5 kHz 6.25 kHz 3.12 kHz
0.1 0.2 0.4 0.8
µs µs µs µs
200-fold
12.5 kHz 6.25 kHz 3.12 kHz 1.56 kHz
0.1 0.2 0.4 0.8
µs µs µs µs
400-fold
6.25 kHz 3.12 kHz 1.56 kHz 0.78 kHz
0.1 0.2 0.4 0.8
µs µs µs µs
Adjustable
The necessary 5 V ± 5 % power supply must be provided by the subsequent electronics.
16
Input frequency fi
IBV 600
IBV 600 models deliver TTL-compatible square-wave output signals over a flange socket. The IBV 606 provides output signals at two flange sockets simultaneously. The connections inside the IBV 606 can be changed such that either one flange socket or both flange sockets deliver sinusoidal voltage signals with a signal level of 1 VPP instead of square-wave output signals.
Interpolation
Adjustable
IBV 600 Series – Model Overview
µs
Page 17
IBV 600 Series
# Mechanical Data Weight
Approx. 0.7 kg
Protection (IEC 529)
IP 65
Operating temperature Storage temperature
–30 to 70° C (32 to 158° F) –30 to 80° C (–22 to 176° F)
Vibration (50 to 2000 Hz) Shock (11 ms)
† 10 m/s2 † 300 m/s2
Dimensions in mm/inches
IBV 606
17
Page 18
# Electrical Data
IBV 600 Series
Power supply
UP = 5 V ± 5 %
Current consumption (Without encoder light source or output load)
IBV 600 IBV 610 IBV 650 IBV 660 B typ. 50 mA, typ. 65 mA, typ. 120 mA, typ. 100 mA, max. 85 mA max. 110 mA max. 160 mA max. 120 mA
With the recommended input circuitry for the subsequent electronics, the maximum permissible current consumption increases by DI = 80 mA. Input signals
Output signals
Sinusoidal scanning signals, preferably from HEIDENHAIN linear and angle encoders. Signal levels
A, B: 0.6 to 1.2 VPP R: 0.2 to 0.85 V
Input frequency fi:
see Model Overview
Incremental signals: Square-wave pulse trains Ua1 and Ua2 and their inverted pulse trains ¢ and £ (according to RS-422). Edge separation a:
see Model Overview
Reference signal: Square-wave pulse Ua0 and its inverted pulse ¤. Width: IBV with interpolation Standard 90° el., switchable to 270° el. IBV without interpolation Standard 90° el., switchable to non-gated (e > a/2) Fault-detection signal: Square-wave pulse ¥ Duration: ts ‡ 20 ms Tristate: With ¥ = Low, outputs for Ua1, Ua2 and ¢, £ can be switched to high impedance. Standard setting: Tristate inactive, can be switched to active Signal levels TTL-compatible UHigh ‡ 2.5 V at – IHigh † 20 mA ULow † 0.5 V at ILow † 20 mA
18
Load capacity
–IHigh † 20 mA ILow † 20 mA CLoad † 1000 pF against 0 V Temporary short circuit of all outputs against 0 V permissible. One output permanently short-circuit proof when T0 < 25° C (77° F).
Switching times
With 1 m (3.3 ft) cable and recommended input circuitry of subsequent electronics: Rise time t+ = typ. 10 ns, max. 30 ns Fall time t– = typ. 10 ns, max. 30 ns
Page 19
Recommended input circuitry of subsequent electronics
+5V Ua Z0
Ua
AM 26 LS 32 MC 3486
RS - 422 DIN 66 259
SN75ALS193 SN75ALS195
+5V R1 R2
UaS
AM 26 LS 32 MC 3486
R1
SN75ALS193 SN75ALS195
R1 = 4.7 kW R2 = 1.8 kW Z0 = 120 W
Permissible cable lengths
Input
UP > 4.75 V: max. 30 m (100 ft) with HEIDENHAIN cable [4 (2 × 0.14 mm2) + (4 × 0.5 mm2)] when Iencoder † 120 mA UP > 4.9 V: max. 60 m (200 ft)
Output
Pin layout, Output (Colors valid for HEIDENHAIN cable)
max. 50 m (164 ft) with HEIDENHAIN cable [4 (2 × 0.14 mm2) + (4 × 0.5 mm2)] and recommended input circuitry of subsequent electronics. The supply voltage level, measured at the cable end via the sensor line, must be maintained. Max. 20 m (66 ft) with minimum edge separation a † 0.125 µs 12-pin flange socket (male)
5
6
8
1
3
4
12
10
2
11
9
7
/
Ua1
¢
Ua2
£
Ua0
¤
5 V* (UP)
0 V* (UN)
5V Sensor
0V Sensor
Vacant
¥
Vacant
Brown
Green
Gray
Pink
Red
Black
Brown/ green
White/ green
Blue
White
/
Violet
Yellow
IEC742 EN 50178 Shield on housing
The sensor line is connected internally to the supply line *With IBV 606: Power supply at X2 only. HEIDENHAIN connecting elements IBV 600
12-pin « TTL
Cable and connector 12-pin, see HEIDENHAIN catalogs “Rotary Encoders,” “Angle Encoders,” ”Exposed Linear Encoders,” ”Sealed Linear Encoders”
Output
12-pin » 1 VPP
Input
« »
Only IBV 606
Cable 12-pin Complete with connector (female) and connector (male) Id.-Nr. 298 399-xx
With one connector (female) Id.-Nr. 309 777-xx
Cable only PUR [4(2 × 0.14 mm2) + (4 × 0.5 mm2)] Id.-Nr. 244 957-01
Connector (male) 12-pin Id.-Nr. 291 697-05
19