580 Series Controller Teach Pendant Operation Manual, pages 1 to 10

Pages 1 to 10 of 217

The original document is the PDF (3.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Hirata H3335

Page 1 read from a scan by OCR; it may hold reading errors

HD-3810E-1

OPERATION MANUAL

580 SERIES CONTROLLER TEACH PENDANT

Hirnin

World Leader in Production Technology

Page 2 read from a scan by OCR; it may hold reading errors

Hirnin

World Leader in Production Technology

Page 3

The information contained herein is the property of Hirata Corporation and shall not be reproduced in whole or in part without prior written approval of Hirata Corporation. The information contained herein is subject to change without notice and should not be constructed as a commitment by Hirata Corporation. Hirata Corporation assumes no responsibility for any errors or omissions in this document. Warranty All of Hirata's products which is passed our formal inspection test shall be guaranteed against faults due to the negligence of Hirata for either earlier period of one year or four thousand hours of operation from the day of shipment from Hirata Factory. This warranty shall be applicable to the parts replacement and/or labor for repair in our factory and transportation cost shall not be applied. We will charge the repair of faults caused by the following reasons: * Wrong usage which are prohibited in the instruction manual. * After the expiration of guarantee period. * Earthquake, fire, riot, violence, war and other force majeure. * Modification, repair or adjustment is performed by unauthorized person. Contact your sales agent for individual warranty coverage.

580 Series Controller Teach Pendant Operation Manual (HD-3810E-1) Copyright 1998 by Hirata Corporation All right reserved. First published in October 1998 First revision in June 1999 Printed in Japan Hirata Corporation Tokyo Head Quarters 3-9-20 Togoshi, Shinagawa, Tokyo 142-0041 JAPAN Phone (03) 3786-1226 Facsimile (03) 3786-1264 Robotics Division 1016-6 Kusuno, Kumamoto 861-5511 JAPAN Phone (096) 245-1333 Facsimile (096) 245-0816

Page 4

NOTATIONS

Notations 1

Dangers, Warnings, Cautions, and Notes There are four levels of special notations are used in this manual. Table 1 Special Notation List Notation

! DANGER ! WARINIG ! CAUTION ! NOTE 2

Description If the actions indicated by a DANGER are not complied with, sever injury or death could result. If the actions indicated by a WARNING are not complied with, injury or major equipment damage could result. If the action specified by the CAUTION is not complied with, damage to your equipment could result. A NOTE provides supplementary information, emphasizes a point or procedure, or gives a tip for easier operation.

Message, Menu, LED, and Keys There are four more types of notations are used in this manual. Table 2 The Other Types of Notation List Notation “Message” 「Menu」 『LED』

It describes keys on the Teach Pendant.

END

3

Description It describes the message on the Teach Pendant inside of “ “. It describes the menu on the Teach Pendant inside of 「 」. It describes the monitor LED on the Teach Pendant inside of 『 』 (e.g., the 『SHIFT』 LED)

Key Operation Following table describes notations for the key operation. Table 3 Key Operation Notation List Notation

Description It describes sigle key you need to press.

END

(In this

END key ) case, press the It describes 2 keys you need to press simultaneously. FUNC HIGH

+ spd CAN

(In this case, press the FUNC HIGH key.)

i spd CAN key while pressing the

Page 5

CHAPTER 1 ABOUT THIS MANUAL AND NOTICE

CHAPTER 1

About This Manual and Notice

This manual is quick start guide manual for Hirata HNC-580 series robot controller. This controller is designed to control SCARA (Hirata AR series : horizontal multi-articulated type) and Cartesian manipulators. The Hirata robot operating system is configured as in the following figure.

Hirata Robot System Configuration

Teach Pendant

Servo LINK

Repeater Servo driver RS-232C

HN C

580 series controller interface unit (Select one of the interface form the following.)

DI/DO Interface board

PC

580 series controller

CC-Link Interface board

Compo/Bus Interface board

PLC Fig.1.1 Hirata Robot System Configuration

1-1

Page 6

CHAPTER 1 ABOUT THIS MANUAL AND NOTICE The basic outline for setting up the robot system is described in this chapter. It may differs depending on robot and controller type. (1)

External cables Power cable, servo LINK cable, Motor line, etc.

(2)

E.S. release

• Check if the Deadman switch is not pressed in TEACH or CHECK mode when the power is ON.

• Check if the E.S. switch on the Teach Pendant is pressed when the power is ON.

• Check if the E.S. connectors on the controller are opened. • Check if the DC24 fuse is blown. Refer to separate volume, “Robot Controller Users Guide, Emergency Stop (E.S.) Functions” for details. (3)

A-CAL Refer to Chapter 3, “A-CAL (Automatic Calibration)” for details.

(4)

Teaching Before the robot starts automatic operation, it is required to preteach the operating positions. The Hirata robot operating system can accept following methods to teach the robot position. • • • •

Enter the coordinate manually via key pad on the Teach Pendant. MDI (Manual Data Input). Move the robot physically and store the position (hereinafter referred to as “Teaching”). Off-line teaching. Data transfer via memory card or RS232C. Data transfer via HR editor i.

After teaching positions to the robot, check to see that the robot moves to the taught position correctly. Then, automatic operation is performed by transmitting signals with external devices. Using the Teach Pendant, the robot data, which called “system data”, can be entered. Input and output operations can be performed. Refer to Chapter 5, “TEACH Mode” for details.

: Refer to separated volume, “HR Editor Operation Manual.” i

1-2

Page 7

CHAPTER 1 ABOUT THIS MANUAL AND NOTICE (5)

Check

• Set the conditions of robot operations using System Parameters. Speed, Acceleration/Deceleration, “PULL-UP” motion, “ARCH UP/DOWN” motion, etc. Refer to Chapter 19, “Details of System Parameters” for details.

• Check the entered position data in CHECK mode. Refer to Chapter 6, “CHECK Mode” for details. (6)

Automatic operation Check the robot operations after checking the following items. Refer to later chapter 7, “ON-LINE Mode” for details. • •

AUTO Mode I/O signal check ON-LINE Mode Data transmission speed with host PC. Station ID number for each robot.

There are some differences in operating procedures depending upon the robot model or system configuration. Ask your system integrator for detailed specification. Hirata also offers robot control language HARL-U1 and HARL-III as add-ons to the standard operating system. Contact your distributor for details.

・ Verify all the cable connectors are properly and firmly connected. ・ Confirm there is no operator or any obstacles in robot’s working envelope. ・ Unspecified usage of this robot may result severe injury or death. Do not install the robot in any other manner than the ones specified in this manual. ・ Do not throw or drop the Teach Pendant. ・ Do not use the entire system at higher than 40℃ and high humidity. The surroundings must be no dust, no smoke, no combustion, and no corrosion. ・ Do not stress the Teach Pendant cable connection. Hold the Pendant body when carrying. ・ When servicing or teaching, no one should put the system into operation. It is suggested to prepare a sign stating not to activate the system.

1-3

Page 8

CHAPTER 2 CONNECTING THE TEACH PENDANT

CHAPTER 2 2.1 2.1.1

Connecting the Teach Pendant

Naming and Function of the Teach Pendant Appearance of the Teach Pendant Emergency Stop (E.S.) Button

LCD (Liquid Crystal Display)

LED Display Function Keys Deadman Switch

Numeric Keys Set Keys

Axis Keys Data Entry Key

Fig.2.1 Naming of the Teach Pendant

2-1

Page 9

CHAPTER 2 CONNECTING THE TEACH PENDANT (1)

Emergency Stop (E.S.) button Emergency Stop button is equipped to the Teach-pendant for the purpose of stopping the robot immediately when an abnormal conditions occur. When this button is pressed, the servo amplifiers/drivers are disconnected electrically from the motors of each axis, and the indicator also lights. Rotate the button clockwise to release from the Emergency Stop status, 『E-STOP』 indicator will then go out after releasing the Emergency Stop status.

(2)

Deadman switch Keep pressing the Deadman-Switch when operating the robot in RO-TEACH, LI-TEACH, or CHECK mode. If this switch is released, the robot will be in Emergency Stop status and it will be stopped.

Release the Deadman switch if any error or abnormal occurrences are happened. (3)

Function keys Changes the mode on the Teach Pendant. To change the mode, F1

F2

F3

FUNC

F4

, , , or the key during pressing the HIGH press the key on the Teach Pendant. The controller is equipped with a MANUAL/AUTO mode selection key switch. Any conflict between the mode of the Teach Pendant and the controller MANUAL/AUTO selection causes the alert buzzer to sound and the conflicting key entry is ignored. Refer to 2.4, “Mode Select Operation” for details. (4)

Set keys Modifies the position data or the like.

(5)

Numeric keys Inputs the numeric data.

(6)

Axis keys Moves the robot axis by pressing the axis key. The robot axis moves during this key is pressed. The axis moves at high speed by pressing the axis key with the

(7)

FUNC HIGH key.

Data entry key Confirms the entered data by pressing the data entry key,

(8)

ENTER

.

LCD (Liquid Crystal Display) Displays the data and message. Refer to 2.7, “LCD (Liquid Crystal Display)” for details.

2-2

Page 10

CHAPTER 2 CONNECTING THE TEACH PENDANT (9)

LED display ① 『SHIFT』 SHIFT key is pressed, the 『SHIFT』 LED will Every time the switch between ON and OFF. When the 『SHIFT』 LED is lit, the functions of the lower case letters on the pink are selected. ② 『HOLD』 The 『HOLD』 LED is lit if any axis is held (servo lock). There is a “*” mark next to the axis which is held. (Example) Only Z-Axis is held 0050 M10 F99 S00 R 0 X 0500.05 Y 0080.00 *Z 0020.10 W 0100.00 LI-TEACH RB1 [WORLD]

In KEY-IN mode, the HOLD will be cleared; however, the only axes equipped with a brake is held by the brake instead. The 『HOLD』 LED becomes OFF. ③ 『READY』 Turns ON when the controller is ready for the automatic operation, and it satisfied the following conditions: • Mode is in ON-LINE on the Teach Pendant. • •

A-CAL is completed. No error is occurred.

• DI signal inputs the IN0 (SELECT signal). Normally ON during the automatic operation. Check the conditions if the 『READY』 LED becomes OFF during the automatic operation. ④ 『A-CAL』 Turns ON if A-CAL is/has been completed. ⑤ 『OVER』 Turns ON when the OVERRUN (OVR) sensor is ON. “OVERRUN” is also displayed on the message line. ⑥ 『E-STOP』 Turns ON when an abnormal condition or an error occurs. “EMERGENCY STOP” is also displayed on the message line.

2.1.2

Specification of the Teach Pendant Table 2.1 Specification of the Teach Pendant Item Type Size Cable length Weight Environment Modes Display Motion stop

Specification H-3335 107mm(W) 238mm(D) 40mm(H) 4m(15m as option) 1kg(including 4m cable) Operating temperature : 0 to 40 ℃ Storage temperature : -20 to 60℃ KEY-IN, TEACH, CHECK, ON-LINE LCD(20×4), LED Using by Emergency Stop button (lock type), Deadman switch

2-3