Page 71
CHAPTER 8 DATA EDITING
8.3
Deleting Position Data If you want to delete certain position data after creating position data in KEY-IN or TEACH mode, perform the following steps. Note that deletion of position data influences the data that have already been taught. Therefore, care should be taken before deleting. (1)
FUNC
Set the Teach Pendant to KEY-IN mode ( HIGH + (
SHIFT
FUNC HIGH
+
F2
F1
) or TEACH mode
).
(2)
Display the address where the position data will be deleted.
(3)
key to blink the 『SHIFT』 LED. Press the INS key. Press the Then, the message “DELETE OK?” appears on the message line and a buzzer sounds.
(4)
Confirm that the correct address and data are to be deleted. After del
SHIFT
ENTER key to delete the data. The the confirmation, press the current data will be deleted, and the data in the next address will be displayed. To cancel the data deleting operation, press any key other than the
ENTER key.
When the program controlling automatic operation of the robots is installed on the PLC, deleting position data will cause error in automatic operation. Data deletion changes the order of position data as in following table. Therefore, when data has been deleted, the sequencer program must be modified accordingly.
When data in an address has been deleted, the data in the last address specified by 「LIMIT」→「ADDRESS MAX」→「ADDRESS MAX」 in the System Generation mode will be copied into the address immediately before the last address. Data in each of the addresses following the address where the data have been deleted will be decremented one. Also, the last address is initialized. Table 8. 2 Position Data Deletion Before After Address Data Address Data 49 M0 F0 X0 Y0 Z0 W0 49 M0 F0 X0 Y0 Z0 W0 50 M1 F1 X1 Y1 Z1 W1 50 M1 F1 X1 Y1 Z1 W1 51 M2 F2 X2 Y2 Z2 W2 51 M3 F3 X3 Y3 Z3 W3 Data Deletion→ 52 M3 F3 X3 Y3 Z3 W3 52 M4 F4 X4 Y4 Z4 W4 *The position data includes the data for S-code and LOCAL code.
8-3
Page 72
CHAPTER 8 DATA EDITING
8.4
Copying Position Data To copy position data into other addresses, perform the steps described below.
8.5
FUNC
(1)
Set the Teach Pendant to KEY-IN mode ( HIGH +
(2)
Enter the source address, and press the
(3)
Enter the destination address, and press the
READ
F1
).
key. ENTER key twice.
Editing Position Data in Blocks FUNC p.ed
Press the HIGH + 5 keys. This activates the block operation mode for position memory. The position data blocks that can be edited in this mode are those in address 0 up to the address which is specified by 「LIMIT」→ 「ADDRESS MAX」→「ADDRESS MAX」 in the System Generation mode. The details are as described below.
8.5.1
Basic Operation The starting screen of this mode is illustrated below. Immediately after the activation of this mode, the shaded portion is displayed. To display the items following the “MODE COMMAND” in sequence, press the scroll.
up DOWN key to
POSITION COMMAND START ADDRESS 0000 END ADDRESS 0000 SET ADDRESS 0000 MODE COMMAND [MOVE] Push END Key !!
Fig. 8. 1 Position Data Block Edition (1)
Enter the desired address in the space next to each of the “START ADDRESS,” “END ADDRESS,” and “SET ADDRESS.” And press ENTER key twice to specify and set the data block. The entry the items are described in following table. Table 8. 3 Description of Entry Items for Position Data Block Edition Entry Item START ADDRESS END ADDRESS SET ADDRESS MODE COMMAND
Description Specifies the starting address of a block. Specifies the ending address of a block. Specifies the address for the block. Specifies the operation contents.
8-4
Page 73
CHAPTER 8 DATA EDITING (2)
There are five commands available as the 「MODE COMMAND」. io SEL
And each command can be selected by the s.ed 4 through key or one of the
* 0 numeric keys.
① MOVE : Moves a block. ② INS
: Inserts a block.
③ DEL ④ SET
: Deletes a block. : Sets a block.
⑤ INIT
: Initializes a block
(3)
Press the
END
(4)
To execute the selected command, press the key. The message “Position **** OK?” appears. ENTER key.
When “**** Completed!!” is displayed on the screen, the command has been executed. The “****” shown above indicates a selected command.
8.5.2
Moving Position Data Block (MOVE) With this command, data located in the 「START ADDRESS」 through 「END ADDRESS」 are moved to the 「SET ADDRESS」. This MOVE command is different from the INS command because the data originally located in the destination address specified as 「SET ADDRESS」 will be overridden and replaced with the block moved. For example, when position data addressed 10 through 14 are moved to the specified address 30, the result of this data moving is as shown in the table below. In this case, 100 is allotted for the addresses specified by 「LIMIT」→ 「ADDRESS MAX」→「ADDRESS MAX」 in the System Generation mode. Table 8. 4 Moving Position Data Block Before Address 9 10 11 12 13 14 15 ・ ・ ・ 98 99 100
After
Data Data 9 Data 10 Data 11 Data 12 Data 13 Data 14 Data 15 ・ ・ ・ Data 98 Data 99 Data 100
Moving the data
8-5
Address 29 30 31 32 33 34 35 ・ ・ ・ 98 99 100
Data Data 29 Data 10 Data 11 Data 12 Data 13 Data 14 Data 35 ・ ・ ・ Data 98 Data 99 Data 100
Page 74
CHAPTER 8 DATA EDITING
8.5.3
Inserting Position Data Block (INS) Data located in the 「START ADDRESS」 through 「END ADDRESS」 are inserted to the 「SET ADDRESS」 with this command. The data originally located in the 「SET ADDRESS」 and the following ones will be entirely shifted, and newly addressed with a larger number by the increase (the number of addresses inserted). The data pushed out of the address range set by 「LIMIT」→「ADDRESS MAX」→「ADDRESS MAX」 in the System Generation mode becomes invalid. For example, when position data addressed 10 through 14 are inserted to the specified address 30, the result of this data insertion is as shown in the table below. In this case, 100 is the allotted number of addresses specified by 「LIMIT」→「ADDRESS MAX」→「ADDRESS MAX」 in the System Generation mode. Therefore, the data previously addressed 96 through 100 will be pushed out of the range and become invalid. Table 8. 5 Position Data Block Insertion Before Address 9 10 11 12 13 14 15 ・ 96 97 98 99 100
After
Data Data 9 Data 10 Data 11 Data 12 Data 13 Data 14 Data 15 ・ Data 96 Data 97 Data 98 Data 99 Data 100
Data insertion
These data is pushed out if 100 is allocated at the 「ADDRESS MAX」.
Address 29 30 31 32 33 34 35 ・ ・ ・ 98 99 100
Data Data 29 Data 10 Data 11 Data 12 Data 13 Data 14 Data 30 ・ ・ ・ Data 93 Data 94 Data 95
When a block addressed by a larger number than that of the 「SET ADDRESS」 is inserted, it may take you several seconds to complete the insertion depending on the data size. If you do not need the data located in the destination addresses, use MOVE command. (Refer to 8.5.2, “Moving Position Data Block (MOVE)”) for a faster operation. Also, note that each address following the inserted block will become larger than its previous address number by the number of addresses inserted, when a block is inserted from downstream.
8-6
Page 75
CHAPTER 8 DATA EDITING
8.5.4
Deleting Position Data Block (DEL) Use this command to delete a position data block located in the 「START ADDRESS」 through 「END ADDRESS」. For example, when position data address 10 through 14 are deleted, the result of this data deletion is as shown in the table below. Here, 100 is the allotted number of addresses specified by 「LIMIT」→「ADDRESS MAX」→ 「ADDRESS MAX」 in the System Generation mode. Therefore, Addresses 96 through 100 are initialized. Table 8. 6 Position Data Block Deletion Before Address 9 10 11 12 13 14 15 ・ 96 97 98 99 100
8.5.5
After
Data Data 9 Data 10 Data 11 Data 12 Data 13 Data 14 Data 15 ・ Data 96 Data 97 Data 98 Data 99 Data 100
Data block deletion
Address 9 10 11 12 13 14 15 ・ 96 97 98 99 100
Data Data 9 Data 15 Data 16 Data 17 Data 18 Data 19 Data 20 ・ Initialized data Initialized data Initialized data Initialized data Initialized data
Setting Position Data Block (SET) Use this command to set data specified by 「SET ADDRESS」 into addresses specified by 「START ADDRESS」 through 「END ADDRESS」. For instance, when the data address 98 is set to addresses 10 through 14, the result of this data setting becomes as shown in the table below. Here, 100 is the allotted number of addresses specified by 「LIMIT」→「ADDRESS MAX」→「ADDRESS MAX」 in the System Generation mode. The data addressed 10 through 14 are overridden respectively by the data located in address 98. Table 8. 7 Position Data Block Setting Before Address 9 10 11 12 13 14 15 ・ ・ ・ 98 99 100
After
Data Data 9 Data 10 Data 11 Data 12 Data 13 Data 14 Data 15 ・ ・ ・ Data 98 Data 99 Data 100
The data of address 98 setting.
8-7
Address 9 10 11 12 13 14 15 ・ ・ ・ 98 99 100
Data Data 9 Data 98 Data 98 Data 98 Data 98 Data 98 Data 15 ・ ・ ・ Data 98 Data 99 Data 100
Page 76
CHAPTER 8 DATA EDITING
8.5.6
Initializing Position Data Block (INIT) When this command is executed, the data specified by 「START ADDRESS」 through 「END ADDRESS」 are initialized. 0010 M?? F99 X 0000.00 Y Z 0000.00 W R 0000.00 C
S00 L 0 0000.00 0000.00 0000.00
Fig. 8. 2 Position Data Initialization(The Robot has 6-Axes)
8-8
Page 77
CHAPTER 9 INPUT/OUTPUT OPERATIONS
CHAPTER 9 9.1
INPUT/OUTPUT Operations
DI/DO Monitor io
FUNC
Pressing the HIGH + SEL keys activates DI/DO monitor mode and the following display appears on the screen. In this mode, digital outputs (DO) in the line on which the cursor is placed can be turned ON/OFF with the numeric keys. DI 00000000 00000000←① 1 00000000 00000000←② DO 00000000 00000000←③ 1 00000000 00000000←④
a
c
d
b
DI 1-15 input status is displayed by bit. DI 16-31 input status is displayed by bit. DO 0-15 output status is displayed by bit. DO16-31output status is displayed by bit.
(Standard) (Option) (Standard) (Option)
Fig.9.1 DI/DO Monitor Mode up
(1)
Press the DOWN key to move the cursor “■” to the desired line. The cursor can be moved among the four positions indicated as “a”, “b”, “c”, and “d” in the figure above.
(2)
Turn ON/OFF the desired output. s.g
*
Each of the numeric keys, 0 through 7 , corresponds to each of the eight bits in the line on which the cursor “■” is currently placed. By pressing the corresponding numeric key, the output turns ON or OFF. That is, pressing a corresponding numeric key turns "0" to "1" or "1" to "0." The bit number 0 indicates that the output status is OFF, and 1 indicates the status is ON. 01234567
(3)
← Numeric key 0-7
a 00000000
← DO 0-7
b 00000000
← DO 8-15
c 00000000
← DO 16-23 (Option)
d 00000000
← DO 24-31 (Option)
To exit this mode, press the spd CAN key.
Most of the digital outputs (DO) can be output in each mode; however, in AUTO mode, BP outputs, ZONE outputs, A-CAL outputs, and AUTO outputs cannot be operated because they are controlled by the system.
9-1
Page 78
CHAPTER 9 INPUT/OUTPUT OPERATIONS
9.2
Manually Outputting M-Data Signals In KEY-IN, TEACH, or CHECK mode, the controller gives to its output signals the outputs corresponding to the values set as M-data. When output signals of the controller are used, you can check the operations of other components through operation of the output signals in CHECK mode or during teaching. For M-data, refer to "16.4.1, List of M-Data Functions." In this section, steps to manually output M-data are described. (1)
Select KEY-IN, TEACH, or CHECK mode by the Teach Pendant.
(2)
Move the cursor to the position for M-data.
(3)
Press the keys corresponding to the value of M-data to be output. For example, press the data to 10.
(4)
cal 1 key and then, the
* 0 key to set the M- m.c
Press the M.OUT key. The output conforming to the M-data value, displayed immediately before the key was pressed, will be given to the output signal of the controller. m.c
ENTER
・ If you press the key before pressing the M.OUT key, the position data, the address of which is currently displayed, will be entered and set. ENTER
When you have pressed the key by mistake, the confirming message "ENTER OK?" appears on the message line. Press any key ENTER other than the key to cancel the position data setting operation. ・ The output operation will be retained until the next output is given. If the mode is switched into ON-LINE, or the power supply is interrupted, all the outputs will be turned OFF.
9-2
Page 79
CHAPTER 10 HOLD FUNCTION
CHAPTER 10
HOLD Function
Currently this function is not used for this system. Normally, all axes are held in TEACH and CHECK mode. However, when the coordinates system display is set to “8”, the HOLD function will be cancelled and only the axes equipped with a brake are held. Also, in KEYIN mode, the HOLD function will be cancelled and only the axes equipped with a brake are held by the brake.
10-1
Page 80
CHAPTER 11 POSITIONING ADDRESS HISTORY
CHAPTER 11
Positioning Address History
The controller saves the addresses of the data determined during positioning in automatic operation. The controller saves such addresses at the time when the START or NEXT signal enters the leading edge. At the same time, the controller saves whether the positioning data has been successfully addressed or not. FUNC task
The display changes each time the HIGH + 2 keys are pressed. Press these two keys until the following display appears on the screen (Refer to (2) FUNC HIGH
+ task 2
[task] keys in 2.9 “Function Mode”).
POSITIONING HISTORY 0000○→ 0005○→ 0010○ 0021○→ 0004i→ 0007○ 0511○→ 0050○→ 0008×
Newest positioning address
: Interruption occurrence (Underbar) × : Error occurrence (The Alphabet letters assinged to each error will be displayed. Refer to the Table 11.1, Error Code for Positioning Address History.) ○ : Normal completion
Fig. 11.1 Positioning Address History In the figure above, Positioning Address History, the latest positioning address saved is “0008” while the oldest one is “0000.” When a new position is used, the address of this new position is displayed in the space where “0008” is currently displayed. The rest of the addresses are shifted up and the history is updated. The controller can save up to 9 positioning addresses including the most current one, clearing the oldest one. “×” in the figure is indicated next to “0008” as an error code. Actually, an alphabet letter, instead of “×,” is displayed to indicate an error. The description of error codes is given below. Table 11.1 Error Code for Positioning Address History Error Code A B C D E F G
H
Description Positioning is not completed. Emergency Stop is activated. A-CAL does not complete normally. Address value is outside the limit. M-data error No sensor found Free curve interpolation data error Position data is outside the limit. Overrun System generation data destroyed. Position data destroyed Servo parameter destroyed CPU board battery low Memory card battery low Encoder battery low CPU
11-1