L100 Series Inverter Instruction Manual: Drive Parameter Settings Tables
Pages 176 to 182 of 193, from L100 Series Inverter Instruction Manual
The original document is the PDF (5.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Hitachi L100-040HFU
Page 176
Drive Parameter
Settings Tables In This Appendix.... page, INTPOCUCTION 10.0... .... cece eeccceeeeeeeeceeecaeeeseeeeeeeeseees 2, Parameter Settings for Keypad Entry.............. 2
Page 177
B–2
Introduction
Introduction This appendix lists the user-programmable parameters for the L100 series inverters and the default values for European and U.S. product types. The right-most column of the tables is blank, so you can record values you have changed from the default. This involves just a few parameters for most applications. This appendix presents the parameters in a format oriented toward the keypad on the inverter.
Parameter Settings for Keypad Entry Appendix B
L100 series inverters provide many functions and parameters that can be configured by the user. We recommend that you record all parameters that have been edited, in order to help in troubleshooting or recovery from a loss of parameter data. Inverter model
}
This information is printed on the specification label located on the right side of the inverter.
L100
MFG. No.
Main Profile Parameters “F” Group Parameters Func. Code
Name
Default Setting -FE (Europe)
-FU (USA)
–FR (Japan)
F_01
Output frequency setting
0.0
0.0
0.0
F_02
Acceleration (1)
10.0
10.0
10.0
F_03
Deceleration (1)
10.0
10.0
10.0
F_04
Keypad Run key routing
00
00
00
User Setting
Page 178
L100 Inverter
B–3
Standard Functions “A” Group Parameters Func. Code
Name
Default Setting -FE (Europe)
-FU (USA)
–FR (Japan)
Frequency source setting
01
01
00
A_02
Run command source setting
01
01
02
A_03
Base frequency setting
50.0
60.0
60.0
A_04
Maximum frequency setting
50.0
60.0
60.0
A_11
O/OI–L input active range start frequency
0
0
0
A_12
O/OI–L input active range end frequency
0
0
0
A_13
O/OI–L input active range start voltage
0
0
0
A_14
O/OI–L input active range end voltage
100
100
100
A_15
O/OI–L input start frequency enable
01
01
01
A_16
External frequency filter time constant
8
8
8
A_20
Multi-speed 0 setting
0
0
0
A_21
Multi-speed 1 setting
0
0
5
A_22
Multi-speed 2 setting
0
0
10
A_23
Multi-speed 3 setting
0
0
15
A_24
Multi-speed 4 setting
0
0
20
A_25
Multi-speed 5 setting
0
0
30
A_26
Multi-speed 6 setting
0
0
40
A_27
Multi-speed 7 setting
0
0
50
A_28
Multi-speed 8 setting
0
0
60
A_29
Multi-speed 9 setting
0
0
0
A_30
Multi-speed 10 setting
0
0
0
A_31
Multi-speed 11 setting
0
0
0
A_32
Multi-speed 12 setting
0
0
0
A_33
Multi-speed 13 setting
0
0
0
A_34
Multi-speed 14 setting
0
0
0
A_35
Multi-speed 15 setting
0
0
0
Appendix B
A_01
User Setting
Page 179
B–4
Parameter Settings for Keypad Entry
Appendix B
“A” Group Parameters Func. Code
Name
A_38
Default Setting -FE (Europe)
-FU (USA)
–FR (Japan)
Jog frequency setting
1.0
1.0
1.0
A_39
Jog stop mode
00
00
00
A_41
Torque boost method selection
00
00
00
A_42
Manual torque boost value
11
11
11
A_43
Manual torque boost frequency adjustment
10.0
10.0
10.0
A_44
V/f characteristic curve selection
00
00
00
A_45
V/f gain setting
100
100
100
A_51
DC braking enable
00
00
00
A_52
DC braking frequency setting
0.5
0.5
0.5
A_53
DC braking wait time
0.0
0.0
0.0
A_54
DC braking force during deceleration
0
0
0
A_55
DC braking time during deceleration
0.0
0.0
0.0
A_61
Frequency upper limit setting
0.0
0.0
0.0
A_62
Frequency lower limit setting
0.0
0.0
0.0
A_63, A_65, A_67
Jump (center) frequency setting
0.0
0.0
0.0
A_64, A_66, A_68
Jump (hysteresis) frequency width setting
0.5
0.5
0.5
A_71
PID Enable
00
00
00
A_72
PID proportional gain
1.0
1.0
1.0
A_73
PID integral time constant
1.0
1.0
1.0
A_74
PID derivative gain
0.0
0.0
0.0
A_75
PV scale conversion
1.00
1.00
1.00
A_76
PV source setting
00
00
00
A_81
AVR function select
02
00
02
A_82
AVR voltage select
230/400
230/460
200/400
A_92
Second acceleration time setting
15.0
15.0
15.0
A_93
Second deceleration time setting
15.0
15.0
15.0
User Setting
Page 180
L100 Inverter
“A” Group Parameters Func. Code
Name
B–5
Default Setting -FE (Europe)
-FU (USA)
–FR (Japan)
Select method to switch to second accel/decel profile
00
00
00
A_95
Acc1 to Acc2 frequency transition point
0.0
0.0
0.0
A_96
Dec1 to Dec2 frequency transition point
0.0
0.0
0.0
A_97
Acceleration curve selection
00
00
00
A_98
Deceleration curve selection
00
00
00
Appendix B
A_94
User Setting
Page 181
B–6
Parameter Settings for Keypad Entry
Fine Tuning Functions “B” Group Parameters
Appendix B
Func. Code
Name
Default Setting -FE (Europe)
-FU (USA)
–FR (Japan)
B_01
Selection of automatic restart mode
00
00
00
B_02
Allowable under-voltage power failure time
1.0
1.0
1.0
B_03
Retry wait time before motor restart
1.0
1.0
1.0
B_12
Level of electronic thermal setting
Rated current for each inverter
Rated current for each inverter
Rated current for each inverter
B_13
Electronic thermal characteristic
01
01
00
B_21
Overload restriction operation mode
01
01
01
B_22
Overload restriction setting
Rated current x 1.25
Rated current x 1.25
Rated current x 1.25
B_23
Deceleration rate at overload restriction
1.0
1.0
1.0
B_31
Software lock mode selection
01
01
01
B_32
Reactive current setting
Rated current x 0.58
Rated current x 0.58
Rated current x 0.58
B_81
[FM] terminal analog meter adjustment
80
80
80
B_82
Start frequency adjustment
0.5
0.5
0.5
B_83
Carrier frequency setting
5.0
5.0
12.0
B_84
Initialization mode (parameters or trip history)
00
00
00
B_85
Country code for initialization
01
02
00
B_86
Frequency scaling conversion factor
1.0
1.0
1.0
B_87
STOP key enable
00
00
00
B_88
Restart mode after FRS
00
00
00
B_89
Data select for digital op. OPE-J
01
01
01
User Setting
Page 182
L100 Inverter
B–7
Intelligent Terminal Functions “C” Group Parameters Func. Code
Name
Default Setting -FE (Europe)
-FU (USA)
–FR (Japan)
Terminal [1] function
00
00
00
C_02
Terminal [2] function
01
01
01
C_03
Terminal [3] function
02
16
02
C_04
Terminal [4] function
03
13
03
C_05
Terminal [5] function
18
18
18
C_11
Terminal [1] active state
00
00
00
C_12
Terminal [2] active state
00
00
00
C_13
Terminal [3] active state
00
00
00
C_14
Terminal [4] active state
00
01
00
C_15
Terminal [5] active state
00
00
00
C_21
Terminal [11] function
01
01
01
C_22
Terminal [12] function
00
00
00
C_23
[FM] signal selection
00
00
00
C_31
Terminal [11] active state (–FU), 00, Reserved (–FE / FR)
00, 00
Terminal [12] active state (–FU), 00, Terminal [11] active state (–FE / FR)
00, 00
C_33
Alarm relay terminal active state
01
01
01
C_41
Overload level setting
Inverter rated current
Inverter rated current
Inverter rated current
C_42
Frequency arrival setting for accel
0.0
0.0
0.0
C_43
Arrival frequency setting for decel
0.0
0.0
0.0
C_44
PID deviation level setting
3.0
3.0
3.0
C_91
Debug mode enable
00
00
00
C_32
Appendix B
C_01
User Setting
Do not edit