Drive Parameter

Settings Tables In This Appendix.... page, INTPOCUCTION 10.0... .... cece eeccceeeeeeeeceeecaeeeseeeeeeeeseees 2, Parameter Settings for Keypad Entry.............. 2

Page 177

B–2

Introduction

Introduction This appendix lists the user-programmable parameters for the L100 series inverters and the default values for European and U.S. product types. The right-most column of the tables is blank, so you can record values you have changed from the default. This involves just a few parameters for most applications. This appendix presents the parameters in a format oriented toward the keypad on the inverter.

Parameter Settings for Keypad Entry Appendix B

L100 series inverters provide many functions and parameters that can be configured by the user. We recommend that you record all parameters that have been edited, in order to help in troubleshooting or recovery from a loss of parameter data. Inverter model

}

This information is printed on the specification label located on the right side of the inverter.

L100

MFG. No.

Main Profile Parameters “F” Group Parameters Func. Code

Name

Default Setting -FE (Europe)

-FU (USA)

–FR (Japan)

F_01

Output frequency setting

0.0

0.0

0.0

F_02

Acceleration (1)

10.0

10.0

10.0

F_03

Deceleration (1)

10.0

10.0

10.0

F_04

Keypad Run key routing

00

00

00

User Setting

Page 178

L100 Inverter

B–3

Standard Functions “A” Group Parameters Func. Code

Name

Default Setting -FE (Europe)

-FU (USA)

–FR (Japan)

Frequency source setting

01

01

00

A_02

Run command source setting

01

01

02

A_03

Base frequency setting

50.0

60.0

60.0

A_04

Maximum frequency setting

50.0

60.0

60.0

A_11

O/OI–L input active range start frequency

0

0

0

A_12

O/OI–L input active range end frequency

0

0

0

A_13

O/OI–L input active range start voltage

0

0

0

A_14

O/OI–L input active range end voltage

100

100

100

A_15

O/OI–L input start frequency enable

01

01

01

A_16

External frequency filter time constant

8

8

8

A_20

Multi-speed 0 setting

0

0

0

A_21

Multi-speed 1 setting

0

0

5

A_22

Multi-speed 2 setting

0

0

10

A_23

Multi-speed 3 setting

0

0

15

A_24

Multi-speed 4 setting

0

0

20

A_25

Multi-speed 5 setting

0

0

30

A_26

Multi-speed 6 setting

0

0

40

A_27

Multi-speed 7 setting

0

0

50

A_28

Multi-speed 8 setting

0

0

60

A_29

Multi-speed 9 setting

0

0

0

A_30

Multi-speed 10 setting

0

0

0

A_31

Multi-speed 11 setting

0

0

0

A_32

Multi-speed 12 setting

0

0

0

A_33

Multi-speed 13 setting

0

0

0

A_34

Multi-speed 14 setting

0

0

0

A_35

Multi-speed 15 setting

0

0

0

Appendix B

A_01

User Setting

Page 179

B–4

Parameter Settings for Keypad Entry

Appendix B

“A” Group Parameters Func. Code

Name

A_38

Default Setting -FE (Europe)

-FU (USA)

–FR (Japan)

Jog frequency setting

1.0

1.0

1.0

A_39

Jog stop mode

00

00

00

A_41

Torque boost method selection

00

00

00

A_42

Manual torque boost value

11

11

11

A_43

Manual torque boost frequency adjustment

10.0

10.0

10.0

A_44

V/f characteristic curve selection

00

00

00

A_45

V/f gain setting

100

100

100

A_51

DC braking enable

00

00

00

A_52

DC braking frequency setting

0.5

0.5

0.5

A_53

DC braking wait time

0.0

0.0

0.0

A_54

DC braking force during deceleration

0

0

0

A_55

DC braking time during deceleration

0.0

0.0

0.0

A_61

Frequency upper limit setting

0.0

0.0

0.0

A_62

Frequency lower limit setting

0.0

0.0

0.0

A_63, A_65, A_67

Jump (center) frequency setting

0.0

0.0

0.0

A_64, A_66, A_68

Jump (hysteresis) frequency width setting

0.5

0.5

0.5

A_71

PID Enable

00

00

00

A_72

PID proportional gain

1.0

1.0

1.0

A_73

PID integral time constant

1.0

1.0

1.0

A_74

PID derivative gain

0.0

0.0

0.0

A_75

PV scale conversion

1.00

1.00

1.00

A_76

PV source setting

00

00

00

A_81

AVR function select

02

00

02

A_82

AVR voltage select

230/400

230/460

200/400

A_92

Second acceleration time setting

15.0

15.0

15.0

A_93

Second deceleration time setting

15.0

15.0

15.0

User Setting

Page 180

L100 Inverter

“A” Group Parameters Func. Code

Name

B–5

Default Setting -FE (Europe)

-FU (USA)

–FR (Japan)

Select method to switch to second accel/decel profile

00

00

00

A_95

Acc1 to Acc2 frequency transition point

0.0

0.0

0.0

A_96

Dec1 to Dec2 frequency transition point

0.0

0.0

0.0

A_97

Acceleration curve selection

00

00

00

A_98

Deceleration curve selection

00

00

00

Appendix B

A_94

User Setting

Page 181

B–6

Parameter Settings for Keypad Entry

Fine Tuning Functions “B” Group Parameters

Appendix B

Func. Code

Name

Default Setting -FE (Europe)

-FU (USA)

–FR (Japan)

B_01

Selection of automatic restart mode

00

00

00

B_02

Allowable under-voltage power failure time

1.0

1.0

1.0

B_03

Retry wait time before motor restart

1.0

1.0

1.0

B_12

Level of electronic thermal setting

Rated current for each inverter

Rated current for each inverter

Rated current for each inverter

B_13

Electronic thermal characteristic

01

01

00

B_21

Overload restriction operation mode

01

01

01

B_22

Overload restriction setting

Rated current x 1.25

Rated current x 1.25

Rated current x 1.25

B_23

Deceleration rate at overload restriction

1.0

1.0

1.0

B_31

Software lock mode selection

01

01

01

B_32

Reactive current setting

Rated current x 0.58

Rated current x 0.58

Rated current x 0.58

B_81

[FM] terminal analog meter adjustment

80

80

80

B_82

Start frequency adjustment

0.5

0.5

0.5

B_83

Carrier frequency setting

5.0

5.0

12.0

B_84

Initialization mode (parameters or trip history)

00

00

00

B_85

Country code for initialization

01

02

00

B_86

Frequency scaling conversion factor

1.0

1.0

1.0

B_87

STOP key enable

00

00

00

B_88

Restart mode after FRS

00

00

00

B_89

Data select for digital op. OPE-J

01

01

01

User Setting

Page 182

L100 Inverter

B–7

Intelligent Terminal Functions “C” Group Parameters Func. Code

Name

Default Setting -FE (Europe)

-FU (USA)

–FR (Japan)

Terminal [1] function

00

00

00

C_02

Terminal [2] function

01

01

01

C_03

Terminal [3] function

02

16

02

C_04

Terminal [4] function

03

13

03

C_05

Terminal [5] function

18

18

18

C_11

Terminal [1] active state

00

00

00

C_12

Terminal [2] active state

00

00

00

C_13

Terminal [3] active state

00

00

00

C_14

Terminal [4] active state

00

01

00

C_15

Terminal [5] active state

00

00

00

C_21

Terminal [11] function

01

01

01

C_22

Terminal [12] function

00

00

00

C_23

[FM] signal selection

00

00

00

C_31

Terminal [11] active state (–FU), 00, Reserved (–FE / FR)

00, 00

Terminal [12] active state (–FU), 00, Terminal [11] active state (–FE / FR)

00, 00

C_33

Alarm relay terminal active state

01

01

01

C_41

Overload level setting

Inverter rated current

Inverter rated current

Inverter rated current

C_42

Frequency arrival setting for accel

0.0

0.0

0.0

C_43

Arrival frequency setting for decel

0.0

0.0

0.0

C_44

PID deviation level setting

3.0

3.0

3.0

C_91

Debug mode enable

00

00

00

C_32

Appendix B

C_01

User Setting

Do not edit