Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of L100 Series Inverter Instruction Manual

Manual · Hitachi

L100 Series Inverter Instruction Manual

Manual193 pagesPDF 5.1 MB

Instruction manual for Hitachi L100 Series inverters (variable-frequency drives), including the 400V class L100-040HFU.

Download the PDF5.1 MB

Covers · 1 model

The models it covers

Summary

What is in it

The instruction manual for the Hitachi L100 Series inverters in the single-phase 200V, three-phase 200V and three-phase 400V classes, a family that includes the L100-040HFE/HFU. It gives the specifications and derating curves, an introduction to variable-frequency drives, step-by-step mounting, wiring and powerup testing, the front panel keypad, every drive parameter group (D, F, A, B and C), use of the intelligent input and output terminals, PID and analog operation, accessories such as dynamic braking, and troubleshooting and maintenance.

Its parts

  1. Getting Started
  2. Inverter Mounting and Installation
  3. Configuring Drive Parameters
  4. Operations and Monitoring
  5. Inverter System Accessories
  6. Troubleshooting and Maintenance

From the manual

Key facts from this manual

Each line names its page in the PDF.

This is the Hitachi L100 Series Inverter Instruction Manual (NB576XE, December 2003), covering the whole L100 line of 200V and 400V class inverters, the L100-040HFU among them. It gives specifications, installation, parameter setup, terminal wiring, accessories, error codes and maintenance.

Read for this summary: pages 1, 21 to 31, 146 to 148 and 153 to 157 of 193.

What it is
L100-040HFU: Hitachi L100 series inverter, 400V class three-phase input, with digital operator (keypad) p. 21, 23
Motor size
L100-040HFU: 4.0 kW (5 HP) p. 23, 28
Input power
L100-040HFU: 3-phase 380 to 460V ±10%, 50/60 Hz ±5% p. 28
Rated output
L100-040HFU: 8.6 A, 3-phase 380 to 460V p. 28
Weight
L100-040HFU: 2.8 kg (6.17 lb) p. 28
Output frequency
0.5 to 360 Hz p. 28
Temperature
Operating (ambient) -10 to 50°C, derating above 40°C; storage -25 to 70°C p. 25, 29
Housing
IP20 p. 28
Communications
Built-in RS-422 interface for PC configuration and field bus modules p. 21
Overload rating
150%, 60 seconds p. 28
Intelligent terminals
Inputs: FW, RV, CF1~CF4, JG, 2CH, FRS, EXT, USP, SFT, AT, RS, PTC; outputs: RUN, FA1,2, OL, OD, AL p. 29
Alarm relay
250 VAC, 2.5A (R load) max.; 30 VDC, 3.0A (R load) max. p. 30
Options
SRW-0EX digital operator / copy unit, dynamic braking unit, FFL100 series EMI filter, DIN rail mounting adapter (35mm rail) p. 22, 148

What this manual walks you through

  • Reading the inverter model number p. 23
  • Choosing a carrier frequency from the derating curves p. 31
  • Choosing reactors, noise filters and braking accessories p. 146, 147, 148
  • Troubleshooting a motor that will not run, runs the wrong way or misses its speed p. 154, 155
  • Reading and clearing error codes p. 156, 157
  • Clearing the trip history p. 156
  • Daily and periodic inspection p. 153

Good to know

  • Wait at least five minutes after turning off input power before maintenance or inspection. p. 153
  • Between 40 and 50° C ambient, reduce the carrier frequency to 2.1 kHz, derate output current by 80% and remove the top cover, which nullifies the NEMA rating. p. 25
  • A braking unit is not included in the inverter. p. 25
  • Ground fault detection at powerup protects the inverter, not people. p. 157
  • After editing data, wait six seconds or more before turning power off. p. 155

Questions this manual answers

What does error E05 mean on a Hitachi L100?

Overload protection: the electronic thermal function detected a motor overload, so the inverter tripped and turned off its output. p. 156

How do I clear a fault on the L100 inverter?

Press the Stop/Reset key. p. 156

What does E08 mean on the L100?

An EEPROM error, caused by noise or excessive temperature; afterward, confirm the parameter values are still correct. p. 156, 157

What input voltage does the L100-040HFU need?

3-phase 380 to 460V ±10%, 50/60 Hz ±5%. p. 28

What motor size is the L100-040HFU for?

4.0 kW (5 HP). p. 23, 28

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Cover1
  2. Safety Messages2
    1. Definitions and Symbols2
    2. Hazardous High Voltage2
    3. General Precautions - Read These First!3
    4. Index to Warnings and Cautions in This Manual5
    5. General Warnings and Cautions10
    6. UL® Cautions, Warnings, and Instructions13
    7. Revisions18
    8. Contact Information19
  3. Getting Started20
    1. Introduction21
    2. L100 Inverter Specifications24
    3. Introduction to Variable-Frequency Drives37
    4. Frequently Asked Questions42
  4. Inverter Mounting and Installation45
    1. Orientation to Inverter Features46
    2. Basic System Description49
    3. Step-by-Step Basic Installation50
    4. Powerup Test63
    5. Using the Front Panel Keypad65
  5. Configuring Drive Parameters72
    1. Choosing a Programming Device73
    2. Using Keypad Devices74
    3. “D” Group: Monitoring Functions77
    4. “F” Group: Main Profile Parameters79
    5. “A” Group: Standard Functions80
    6. “B” Group: Fine Tuning Functions93
    7. “C” Group: Intelligent Terminal Functions103
  6. Operations and Monitoring112
    1. Introduction113
    2. Connecting to PLCs and Other Devices115
    3. Example Wiring Diagram116
    4. Using Intelligent Input Terminals119
    5. Using Intelligent Output Terminals132
    6. Analog Input Operation140
    7. Analog and Digital Monitor Output141
    8. PID Loop Operation143
    9. Configuring the Inverter for Multiple Motors144
20 more lines, from page 145 on
  1. Inverter System Accessories145
    1. Introduction146
    2. Component Descriptions147
    3. Dynamic Braking149
  2. Troubleshooting and Maintenance152
    1. Troubleshooting153
    2. Monitoring Trip Events, History, & Conditions156
    3. Restoring Factory Default Settings159
    4. Maintenance and Inspection160
    5. Warranty167
  3. Glossary and Bibliography168
    1. Glossary169
    2. Bibliography175
  4. Drive Parameter Settings Tables176
    1. Introduction177
    2. Parameter Settings for Keypad Entry177
  5. CE-EMC Installation Guidelines183
    1. CE-EMC Installation Guidelines184
    2. Hitachi EMC Recommendations188
  6. Index189

From the PDF’s own bookmarks.

The whole text · 23 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 151-15
  2. Table of Contents16-19
  3. Getting Started, pages 20 to 2820-28
  4. Getting Started, pages 29 to 3729-37
  5. Getting Started, pages 38 to 4438-44
  6. Inverter Mounting and Installation, pages 45 to 5345-53
  7. Inverter Mounting and Installation, pages 54 to 6254-62
  8. Inverter Mounting and Installation, pages 63 to 7163-71
  9. Configuring Drive Parameters, pages 72 to 8172-81
  10. Configuring Drive Parameters, pages 82 to 9182-91
  11. Configuring Drive Parameters, pages 92 to 10192-101
  12. Configuring Drive Parameters, pages 102 to 111102-111
  13. Operations and Monitoring, pages 112 to 120112-120
  14. Operations and Monitoring, pages 121 to 129121-129
  15. Operations and Monitoring, pages 130 to 138130-138
  16. Operations and Monitoring, pages 139 to 144139-144
  17. Inverter System Accessories145-151
  18. Troubleshooting and Maintenance, pages 152 to 159152-159
  19. Troubleshooting and Maintenance, pages 160 to 167160-167
  20. Glossary and Bibliography168-175
  21. Drive Parameter Settings Tables176-182
  22. CE-EMC Installation Guidelines183-188
  23. Index189-193

The file

Revision and size

RevisionNB576XE, December 2003
PublisherHitachi Industrial Equipment Systems Co., Ltd.
Pages193
PDF5.1 MB
TextText from the PDF itself; pages 145, 168, 176 and 187 are scans, read by OCR, which may hold reading errors.

The first pages · 3 of 193

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 193
Page 2
Page 2of 193
Page 3
Page 3of 193