Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of KBPB Cycler Solid State DC Motor Speed Controls, Installation and Operating Instructions

Manual · KB Electronics

KBPB Cycler Solid State DC Motor Speed Controls, Installation and Operating Instructions

Manual30 pagesPDF 1.4 MB

Installation and operating instructions for the KB Electronics KBPB DC motor speed and reversing controls (KBPB-125, KBPB-225), with a 2006 supplement.

Download the PDF1.4 MB

Covers · 1 model

The models it covers

Summary

What is in it

Installation and operating instructions from KB Electronics for the KBPB full wave solid state DC motor speed and reversing control (models KBPB-125 and KBPB-225), preceded by a 2006 supplement for the KBPB and KBCC-R that gives new connection figures and inhibit switch wiring after the anti-plug reversing module changed to APRM-3. It covers setup, electrical ratings and performance specifications, plug-in horsepower resistor selection, application limits, mounting and wiring, voltage following, fusing, trimpot adjustments, connection diagrams, troubleshooting and parts lists.

Its parts

  1. Simplified Instructions
  2. Introduction
  3. Application Information
  4. Installation Instructions
  5. Adjustments and Control Functions
  6. Application Information and Wiring Connection Diagrams
  7. Troubleshooting Guide
  8. Wiring Diagrams, Schematics and Parts Lists

From the manual

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

Installation and operating instructions for the KB Electronics KBPB Cycler solid state DC motor speed and reversing controls, covering the KBPB-125 (120 VAC) and KBPB-225 (240 VAC), with a front supplement on the APRM-3 reversing module that also applies to the KBCC-R. It covers ratings, plug-in horsepower resistors, mounting, wiring, fusing, trimpot adjustment, switching and reversing hookups, tach feedback and troubleshooting. Most pages are scanned, and it ends with parts lists for the speed control module.

Read for this summary: pages 1 to 21, 23 and 27 to 28 of 30.

Device
Full-wave solid state DC motor speed and reversing control with anti-plug reversing and dynamic braking p. 8, 9
KBPB-225 ratings
KBPB-225: 240 VAC line, 180 VDC motor; 8.0 A DC, or 16.0 A DC and 3 HP with auxiliary heatsink p. 6
Motors
PM and shunt wound DC motors; 240 VAC controls for 180 V SCR rated motors, 120 VAC controls for 90 V p. 8
Horsepower resistor
A Plug-in Horsepower Resistor, supplied separately, must match the motor horsepower and voltage p. 5
Switching
Run-brake, forward-brake-reverse and forward-reverse; up to 10 run-brake cycles per minute p. 9, 15
Acceleration
0.2 to 10 seconds from zero to full speed, factory 1 second p. 8
Ambient temperature
45°C/113°F maximum at full rating p. 9
Speed regulation
1% of set speed over a 50:1 speed range with tachometer feedback p. 19
Voltage following
Isolated analog voltage in place of the speed pot, source impedance 10K ohms or less; KBSI-240D isolator for non-isolated or 4-20 mA signals p. 11
Stopping
S2 terminal opens to brake to stop; an Inhibit switch on I1 and I2 closes to coast to stop p. 2
Tach feedback
7 V/1000 RPM tach to terminal T or 50 V/1000 RPM to terminal B, with jumper J1 cut (an 82K resistor on KBPB-225) p. 19
Fuses
AC line fuse 12 A or 25 A by control rating, armature fuse from the chart; Buss ABC or Littelfuse 326 ceramic p. 12
KBPB-125 ratings
KBPB-125: 120 VAC line, 90-130 VDC motor; 8.0 A DC, or 16.0 A DC with auxiliary heatsink p. 6
Accessories
SI-3 isolator board, KBSI-240D signal isolator, KBAP-240D overload protector, fuse kit KB Part #9870 p. 11, 12, 18, 21

What this manual walks you through

  • Quick setup before first power-up p. 5
  • Choosing the Plug-in Horsepower Resistor p. 5, 7
  • Mounting, AC line connection and supply wire sizes p. 9, 10
  • Fusing the AC line and armature p. 11, 12
  • Adjusting the accel, decel, speed, current limit and IR comp trimpots p. 13, 14, 15
  • Wiring forward-brake-reverse and run-brake-jog switches p. 16, 17, 18
  • Running the control from a programmable controller p. 18
  • Setting up tachometer feedback p. 19
  • Troubleshooting motor and control faults p. 23
  • Speed control module parts list, with changes for 240 V p. 27, 28

Good to know

  • The start/stop circuits are not safety disconnects; use only the AC line for that. p. 2
  • The control must be mounted in an enclosure, away from moisture, metal chips, dust and corrosive atmospheres. p. 2
  • Do not mount the control with the terminal block legend facing down. p. 9
  • Solid state relays and contacts with snubbers must not be used to switch the S terminals. p. 16
  • Consult the maker before use on constant horsepower loads such as saws or drill presses. p. 9

Questions this manual answers

What is the difference between the KBPB-125 and KBPB-225?

The KBPB-125 runs on 120 VAC for 90-130 VDC motors; the KBPB-225 runs on 240 VAC for 180 VDC motors. p. 6

Does the KBPB-225 need a plug-in horsepower resistor?

Yes. It is supplied separately, sized to the motor horsepower and voltage, and is needed for the current limit and IR comp to work properly. p. 5, 14

What is the factory current limit on the KBPB?

About 1.5 times the motor's full load rating; it can be reset with a DC ammeter and a locked motor shaft. p. 14, 15

Can a KBPB be controlled by a PLC?

Yes, with the SI-3 isolator board, which lets an analog signal operate the forward-brake-reverse function. p. 18

The whole text · 3 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30

The file

Revision and size

RevisionSupplement A40150 Rev. C, 7/2006; manual 1989
PublisherKB Electronics, Inc.
Pages30
PDF1.4 MB
TextThe pages are scans; their text was read by OCR, which may hold reading errors.

The first pages · 3 of 30

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 30
Page 2
Page 2of 30
Page 3
Page 3of 30