Page 11 read from a scan by OCR; it may hold reading errors

CAUTION: If control ts wired to a transformer, it is advisable to switch the secondary to disconnect power. If Ine primary is switched, additional snubber capacitors may have to be added across the transformer oulput to prevent damage to the power bridge

| (CAUTION; Do not bundle control wires P,, P,, Py. |, lp. S,-5, wilh line or motor leads. I! wires are over 18", use | shielded cables

C. Voltage Following. All models can be controlled with an isolated analog reference voltage ap ide in lieu of the main speed potentiometer. The voltage is connected to P,(+) and F-.

he contral output voltage will linearily follow the inpul voltage. The source impedance of the input should be 10K ohms or less. The Min trimpot can be used to provide an offset speed. If an offset is not required adjust the Min to0+ or 0O - speed as desired. The Max trimpot is rendered inoperative in the voltage following mode. Use auxiliary trimpot to limit the control range. If the input signal is not isolated, or is a current signal (4 - 20ma), the KBSI-240D Signal lsolator must be used. It will allow direct connection to process controllers and microprocessors.

CAUTION: 1. The voltage leeding P, and F- must be isolated from the AC line, Do not ground P, or F - to set up @ zero of ground reference 2. Do not bundle signal wires to P, and F= with AC line of motor connections. If signal wires are over 18", use shielded cables

D. Fusing. The KBPB™’has provision for a built-in AC line fuse and armature fuse, The AC line fuse protects the control against catastrophic failure. If the fuse blows, the control is miswired, the motor is shorted or grounded, or the KBPB“™controlis detective. The armature fuse provides overload protection for the motor and control. Choose the proper size armature fuse by multiply-ing the maximum de motor amps by 1.7, NOTE: Be sure to fuse each ungrounded AC line supply conductor. Do not fuse neutral or grounded conductors. All fuses should be normal blow ceramic 3AG, ABC or equivalent. (See Table 6 on page 10)

Page 12 read from a scan by OCR; it may hold reading errors

TABLE 6. ARMATURE FUSE CHART

90VDC | 180VDC | APPROX. MOTOR | MOTOR | DC MOTOR FUSE CURRENT RATING HORSEPOWER (AMPS) | (AC AMPS) 1/30 1/15 33 1/2 1/20 1/10 5 3/4 1/15 1/8 65 1 1/12 1/6 85 1-1/4 1/8 1/4 1.3 2 1/6 1/3 1.7 2-1/2 1/4 1/2 2.5 4 1/3 3/4 3.3 5 1/2 1 5.0 B 3/4 1-1/2 7.5 12° 1 2 10.0 15 1-1/2 3 15.0 25°

* Also used as AC Line Fuse.

NOTES:

1. AC Line Fuse is chosen according to the maximum rating of the control: 12 Amp fuse for all motors up to % HP-90V and 1% HP-180VDC.,

25 Amp fuse for all motors 1 and 11 HP-990V and 2 and 3 HP-180VDC. (Use Buss ABC, Litt. 326 ceramic fuse or equivalent.)

2. Armature Fuse can be chosen in accordance with the fuse chart. Note: The armature fuse is calculated based on the approximate full load DC current rating of the motor times a form fac-tor of 1.5. If motor has characteristics not consistent with these approximations, a different fuse value may have to be used. Fuses are available from your distributor. Also available is a Fuse

Kit (KB Part #9870) containing 700 assorted fuses.

Page 13 read from a scan by OCR; it may hold reading errors

SECTION IliI - ADJUSTMENTS AND CONTROL FUNCTIONS - See Safety Warning Page 18

The KBPB has been factory adjusted to provide 0-full speed using the speed control knob. Minimum and Maximum speed trimpots are provided to change the speed from other than O-full speed. The Acceleration (ACCEL) trimpot is provided to allow for a smooth start over an adjustable time period each time the AC power is applied or the speed pot is rotated. The DECEL trimpot controls the amount of ramp-down time when the speed pot is adjusted to a lower speed. Note: If P, is connected to P,, or the enable lead, P,, is opened, the control will ramp down to the MIN speed trimpot, setting. If |, is shorted to |, the control will coast down to zero speed. The Current Limit (CL, or torque output) adjustment is factory set to approximately 142 times the motor rating. The IR Compensation (IR) ts factory adjusted to provide excellent motor regulation under normal operation. The KBPB contains the KB APRM* which provides anti-plug “instant” reverse and solid state dynamic braking. The APRM® contains a trimpot which is used to preset a fixed speed for either the forward or reverse direction (see KBPB connection diagrams for additional information),

NOTE: In order for the IF.’ comp and CL trimpot settings to be correct, the proper Plug-in Horsepower Resistor® must be installed for the particular motor and input voltage being used. Da nol attempl io change the settings of ihe Inmpols unless absolutely necessary since ihey are factory adjusted to near oplimum seltings

The following procedure, presented in order of adjustment sequence, should be used when read-justing all trimpot functions: rectiR SETI 1 SEC FACTORY SETTING 1 SEC.

Fig. 4 ACCEL/DECEL TRIMPOT ADJUSTMENT wn

2 SEC. CAUTION!

[PM motors only], Adjusting the accel time below 5 seconds increases inrush current. Ii may be necessary to measure the peak ay inrush curren! and consull with moter man- @ SC. ufacturer since field magnet demaqnetiza- ot May occur

Rar Io 2 SEE.

fo 26c

ACCEL

Page 14 read from a scan by OCR; it may hold reading errors

A. Acceleration Start. The ACCEL is factory set at approx. 1 second. To readjust to different times, set the knob to the desired position as indicated in Fig. 4. B. Deceleration. The DECEL is factory set to provide minimum ramp-down time. To increase the ramp-down time adjust the DECEL trimpot as indicated in Fig. 4.

C. Maximum Speed Adjustment. Turn Speed Control Knob to full speed (maximum CW position). Adjust max. speed trimpot to new desired setting.

NOTE: Do no! atlempt to adjus! |he max. speed above the rated motor RPM since unstable motor operation may occur. For moderate changes in the max. speed, there will be a slight effect on the min. speed setting when the min, speed is set al zero. There may be a significant variation in the mun. speed setting if the min. speed is at a higher than zero setting

D. Minimum Speed Adjustment. |f a higher than zero minimum speed is desired, readjust the minimum speed by turning the speed control knob to zero setting (full CCW position). Then adjust the min. speed trimpot to the desired setting.

NOTE: The min, speed adjustment will alfect the max. speed selling. Therefore, il is necessary lo readjust the max speed alter the min. speed, and it may be necessary to repeal the sequence unt! both (he min. and max. speeds are sel to desired levels

E. Current Limit (CL/Torque Adjustment). CL circuitry is provided to protect the motor and control against overloads and demagnetization of PM motors. The CL also limits the inrush current to a safe level during startup. The CL is factory set to approximately 1.5 limes the full load rating of the motor (CL trimpot is nominally set to approx. 65% of full CW rotation.)

NOTE: The correct value Plug-in Horsepower Resistor” mus! be installed in order for the CL and IR comp, to operale properly.

To set the CL to factory specifications adjust as follows:

1. Set speed control knob at approximately 30-50% CW rotation. Set CL trimpot to full CCW position. 2. Gonnect a DC ammeter in series with the armature lead.

Page 15 read from a scan by OCR; it may hold reading errors

3, Lock shaft of motor (be sure CL pot is in full CCW position}. Apply power and rotate CL pot CW slowly until DC ammeter reads 1.5 times motor rating (do not exceed 2 times motor rating).

NOTE: If only an AC ammeter is available, it can be installed in series with AC input line. Follow above instructions; however, set AC amperage al 75 limes motor rating

F. iR Compensation Adjustment. IR compensation is provided to substantially improve load regulation. If the load presented to the motor does not vary substantially. the IR adjustment may be set at a minimum level (approximately V4 of full setting). The control ts factory adjusted to approximately 3% regulation. If superior performance is desired (less than 1% speed change of base speed from 0 to full load), then the IR comp. should be adjusted as follows:

NOTE: Excessive IR comp. will cause control to become unstable, which causes motor cogging,

1. Set IR comp. trimpot at approximately 25% of CW roation. Run motor unloaded at approximately V3 speed and record RPM.

2. Run motor with maximum load and adjust [FR comp. trimpot so that the motor speed under load equals the unloaded speed per step 1.

3. Remove load and recheck unloaded RPM. If unloaded RPM has shifted, repeat procedure for more exact regulation.

The KBPB is now compensated to provide minimal speed change under large variations of applied load.

SECTION IV. KBPB APPLICATION INFORMATION

The K8P6 is designed to offer a variety of switching functions. The APRM® module is the inter-face between command signals and the KBMM speed control module. By using terminals §,, 5; and 5, the KBPB can be made to perform the following functions: Run-Brake, Forward-Brake- Reverse and Farward-Reverse (instant anti-plug reverse). Terminal S, is used to supply a control voltage which is adjustable wilh the APRM® trimpot R11. This voltage is used to preset a

Page 16 read from a scan by OCR; it may hold reading errors

14

Jog or Run speed, either in Forward or Reverse direction. INHIBIT "cmaxe to stop » (DECEL Trimpot does not affect the brake time.)

In order for the KBPB control to drive a motor, S, and S; must oi be connected together for Forward and S, and $, must be con- ARM nected together for Reverse. If no connection is made to S,, the control will be in a ''Brake'’ mode. The brake circuit consists of I] le A-an SCR and dynamic brake resistor (AB). An LED indicator on the APRM® shows that power is applied to the SCR gate. If braking is not required, the wire to RB may be disconnected. (Note that the LED will still light with RB disconnected.) No

INHIBIT™: Terminals |, and! provide an Inhibit™ function which electronically extinguishes the output of the control. This circuit is activated by connecting the |, and |, terminals together, When installing the KBPB be sure to follow the mounting and wiring instructions found in Sec. Il.

NOTE: When switching terminals S,, S.. S,, approximately 10ma of current with full motor vollage may be present, Other terminals (1,, !,.P,.P,.P, and $3) are low vollage to each other, but line voltage fo ground, Any switch or relay can be used for switching except solid stale relays or conlacts with A-C networks (snubbers), 5, and 5. must be opened before 5, and 3, are closed and vice versa

The following wiring diagrams are presented to : : mest demonstrate the capabilities of the KBPB. DIA. St alah fy A. Forward-Brake-Reverse with Single Poten- A | alclelele | tiometer. Use an SPDT ON-OFF-ON switch. icoee | Close S, and S; for motor to run in FWD direce 9 | l tion. Open S, for Brake. Close S, and $, for a motor to run in Reverse direction, If Brake position is not required, an SPDT (non-center OFF) |, , ary may be used. This provides instant Anti-plug Ne i orn Reversing. cee poo | LY, wwe |

Page 17 read from a scan by OCR; it may hold reading errors

B. Forward-Brake-Reverse with Adjustable Reverse Speed. Reverse speed is adjustable with the trimpot on the APRM® board. Use a DPDT ON-OFF-ON switch. In the Forward direc- lion, the remote speed pot is used. In the Reverse direction, P, is connected to S, for speed adjustment. If Brake position is not required, a DPDT switch (non-center OFF) may be used. If, while in Forward or Reverse position, a separate Brake function is required, S; may be interrupted using a limit switch or relay. (For remote reverse speed pot adjustment, see Wiring Diagram C.)

C. Forward-Brake-Reverse with Run-Brake- Jog. Jog speed is adjusted with remote speed pot. For SW1 use an SPDT ON-OFF-ON switch. For SWe use DPDT ON-OFF-ON with momentary return from Jog position, (For non-remote Jog speed use trmpot on APRM®, see Wiring Diagram B).

D. Run-Brake-Jog with Adjustable Jog Speed. The Jog speed is adjustable with the trimpot on the APRM*" board. Use a DPDT ON-OFF-ON switch. In the Run mode, the external 5K speed pot is used. In the Jog mode P, is connected to S, and the Jog pot, located on the APRM® , is used for speed adjustment. If Brake position is not required, a DPOT switch (non-center OFF) may be used. If, while in Forward or Jog position,

F- PR P Py fy Te S, Se So Se O]OlOlOlololololo “a OTOlLOLOrOlToOlOlrolsalo * "wre? oe i masz t &-} O BRK Lavi, {) i REV ce POT a | F= P, Py Py 1, Ty Sy Se Sy Sy OVO /OlrolyOololol;alole DIA, Olololololololololo : | Pw Tl Lt | E SK POT PWD ¢} RUN | BRK d 6) 7a. REW WANA REV C} + +O J Oe Sk POT Sw 1 Sw 2

15

Page 18 read from a scan by OCR; it may hold reading errors

a separate Brake function is required, S. may be interrupted using a limit switch or relay. (For remote reverse speed pot adjustment, see Wiring Diagram C.) } | | = E. Isolated Input for $,, S,, $3. An isolator 1 | board SI-3 is available as an accessory. It allows the KBPB forward-brake-reverse function to be | activated by an analog signal. The SI-3 installs jf by removing the 4-pin connector on the APRM, I sg ay Install the SI-3 on the 4-pin header and plug the \.. \, _ mating connector into the Sl-3., - BRK The SI-3 is activated by applying an anal | voltage of 5-10VDE to ‘artninale S, S, for (or Bim ' oe ac ward, or S,, S, for reverse. The KBPB with the ei ial

Sl-3 option is suitable for operation with programmable controllers. For complete isolation of the voltage following input Model KBSI-240 Signal Isolator should also be used.

O, - i =

FWO-BRK-REY CONTROL USING PROGRAMMABLE CONTROLLER FwO-BRE-REW AND DUAL SPOCD CONTROL TL Pc contacts [Yr LL Lee contacts S-10V |+ $1 51 §- mel T S) Ce, [et ge = le E | 4g “ale EBCC-# 53 se_ | th Kace-@ sa)" [se = ad | ee |

SF

|

Hf 3 ls 10 Pe 5" asim Pad ili 2

Page 19 read from a scan by OCR; it may hold reading errors

F. Tachometer feedback (DC tachs only). The load regulation of the control can be improved to 1% of set speed over a 50:1 speed range by use of tachometer feedback. Since no provision is made for the tach input on the terminal block, the tach positive connection must be made directly to the B or T terminal on the speed control module. NOTE: If cantrol is used on a reversing application, the tach wires must also be reversed so that positive (+) is always connected to B or T. To set control for tachometer feedback:

(1) For tach feedback, cut jumper J1 on Printed Circuit Board. (Note: On Model KBPB-225, J1 is an 82K resistor) (2) Connect tach as follows: (a) 7 volts1000 RPM Connect (+) lead to Terminal “T”’ Connect ( - ) lead to Terminal |, or F- . wt (b) 50 volts/1000 RPM Connect (+) lead to Terminal “B” Connect ( - ) lead to Terminal |, or F-

Note: The tachometer voltage input is based on 1,800 RPM motors. For motors other than 1.800 RPM, or for tachometer voltages other than whal is specified, an external tachomeler resistor mus! be used. Install the resistor (Ry) in series with positive (+) tachometer laad and the 7V input on the control, The value of RT may be calculated using the following formula. Rr = (1.26 x Vz x S - 15,900] V7 = Tachometer voltage in volts/1,000 RPM 5 = Base speed of motor in RPM Example: Suppose you have a 3,600 RPM motor with a 20 voll/1,000 RPM tachometer:

Ay = 1.26 x 20 « 3,600, 15,900 = 74,820 Choose the closest ' watt resistor value, which is 75,000; therefore, Ry = 75,000. Re T SPEED + iiss CONTROL Fe-> | - TACHOMETER CONNECTION WITH ADDITION OF R,

Page 20 read from a scan by OCR; it may hold reading errors

G. Enable. Control can be made to start and stop electronically with Enable. This circuit is ‘make to run” which is opposite of Inhibit™.

Stop time is adjustable with DECEL trimpot. To obtain 0 speed when Enable is open MIN speed trimpot must be set to 0 speed. Two-speed operation can be obtained by setting the MIN speed to the desired level.

ENABLE cuake to Run

A+ ARM P3 Pe Pl 4- 2K SPEED POT er SAFETY WARNING - PLEASE READ CAREFULLY

This product should be serviced by a qualified technician, electrician or electrical maintenance personnel familiar with its operation and the hazards involved. Proper installation (see instruction information which accompanies product), which includes wiring, mounting in proper enclosure, fusing or other overcurrent protection and grounding, can reduce the chance of electric shocks, fires or explosion in this product or products used with this product, such as electric motors, switches, coils, solencids and/or relays. Eye protection must be worn when working wilh control under power This product is constructed of materials (plastics, metals, carbon, silicon, etc.) which may be a polen-lial hazard. Individual material salety data sheets (MSDS) are available upon request. Proper shielding, grounding and filtering of this product can reduce the emission of radio frequency interference (AFI) which may adversely affect sensitive electronic equipment. It information is required on this product, contact our factory, It is the respon-sibility of the equipment manufacturer and individual installer to supply this safely warning to the ultimate user of this product. (SW effective 3/83),