The text of a manual · part 1 of 2
Digital Fiber Sensor 2-Output Type FS-V33(P)/V34(P)/V33C(P)/V34C(P) Instruction Manual, pages 1 to 7
Pages 1 to 7 of 8
The original document is the PDF (2.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Keyence FS-V33CP
Page 1
96M11292
Input Circuit Diagram FS-V33/34 3.3 VDC Sensor main circuit
DIGITAL FIBER SENSOR 2-OUTPUT TYPE
FS-V33(P)/V34(P)/V33C(P)/V34C(P)
•
0V
12 to 24 VDC Brown* Sensor main circuit
•
PLC, etc. Blue*
FS-V33P/34P
Read this manual before using the product in order to achieve maximum performance. Keep this manual in a safe place after reading it so that it can be used at any time.
Warning
(Short-circuit current 1 mA or less)
* FS-V33 only
Instruction Manual •
Pink (input)
This product is just intended to detect the object(s). Do not use this product for the purpose to protect a human body or a part of human body. This product is not intended for use as explosion-proof product. Do not use this product in a hazardous location and/or potentially explosive atmosphere. This product is a sensor of DC power supply type. Do not apply AC power. The product may explode or burn if an AC voltage is applied.
PLC, etc.
Pink (input) (Short-circuit current 2 mA or less)
* FS-V33P only
Socket Cable (Sold Separately for FS-V33C (P)/V34C (P)) Precautions on Regulations and Standards
„ Connecting the Socket Cable
„ UL Certificate
Pin and wire color table
1 Connect the socket to the pin on the
This product is an UL/C-UL Listed product. • UL File No. E301717 • Category NRKH,NRKH7 • Enclosure Type 1 (Based on UL50)
amplifier.
Be sure to consider the following specifications when using this product as an UL/ C-UL Listed Product. • Use the power supply with Class 2 output defined in NFPA70 (NEC: National Electrical Code). • Power supply/ Control input/ Control output circuits shall be connected to a single Class 2 source only. • Use with the over current protection device which is rated 24V or more and not more than 2A.
4 3
2 1
Connected pin Core wire No. cover color (1)
Brown
(2)
White
(3)
Blue
(4)
Black
2 Turn the fixing ring on the socket clockwise to fix the socket.
Option (Sold Separately) Mounting bracket (main unit)
End unit
Socket cable Dedicated for FS-V33C(P)/34C(P)
Mounting Unit „ Mounting on a DIN Rail
1 Align the claw at the bottom of the main body with the OP-73880
OP-26751 (a set of two)
OP-73864 (cable length: 2 m) OP-73865 (cable length: 10 m)
DIN rail. While pushing the main body in the direction of the arrow 1, slant it in the direction of the arrow 2.
2 To dismount the sensor, raise the main body in
Part Names the direction of the arrow 3 while pushing the main body in the direction of the arrow 1.
Fiber lock lever
„ Installation on a Wall (Main Unit Only) Attach the unit to the optional mounting bracket (OP-73880), mount them together, and secure them with two M3 screws as shown in the illustration.
DSC
DSC
(
1 2
1 2
Operation status indicators (output 1) Operation status indicators (output 2) Setting value SET button (SET) (Displayed in green) DSC indicator Digital monitor Current value Manual button (Displayed in red) )
OP-73880
1
1
Expansion protective cover Expansion connector
2
2
Channel selection MODE button (MODE) Output selector (L/D ON)
Connecting Multiple Amplifiers Up to 16 sub units can be connected to one main unit.
1 Remove the protection cover on the side of
* Dust cover the main unit.
* FS-V33 (P)/34(P) is a cable, and FS-V33C(P)/34C(P) is a M8 connector.
Output Circuit Diagram
2 Install the amplifier one by one on the DIN rail.
FS-V33(C)/34(C) 12 to 24 VDC
Overcurrent protection circuit
Sensor main circuit
Brown* Black/white Load
Black: control output 1 White: control output 2
0V
FS-V33 (C)P/V34(C)P
4 3
(1) 12-24 VDC (FS-V33C/V33CP only)
recesses on the main unit side until you hear a click sound.
(2) Control output 2 Brown 12 to 24 VDC
Overcurrent protection circuit
2 1
3 Engage the two claws of the child unit with the
Blue
*FS-V33 only
Sensor main circuit
Pin assignment of the connector type
(3) 0 V (FS-V33C/V33CP only)
4 Attach the end units (option: OP-26751) to the
(4) Control output 1 Black/white Load both ends of the connected amplifiers in the same way as in step (2).
Black: control output 1 White: control output 2
5 Sandwich the amplifiers between the end units.
0V Blue*
*FS-V33P only
Tighten the screws at the top (two screws x two units) with a Phillips screwdriver to fix the end units.
1
OP-26751 (a set of two)
Page 2
Connecting Fiber Unit
Making Sensitivity Settings „ Two-point Calibration
1 Open the dust cover in the direction shown by arrow 1.
In this mode, the setting value used will be the mean value of two sensing values obtained with and without a workpiece.
2 Move down the fiber lock lever in the
1 Press the SET button without any workpiece placed in front of the fiber unit.
direction shown by arrow 2.
3 Insert a fiber unit into the fiber insertion holes DSC to a length of the fiber insertion sign (i.e., approximately 14 mm).
1 2
4 Move down the fiber lock lever in the
2 Place a workpiece placed in front of the fiber unit, and press the SET button.
Fiber insertion sign direction shown by arrow 4.
Note
Cable outer dia.
Adapter
φ1.3
Adapter A (OP-26500)
φ1.0
Adapter B (OP-26501)
Workpiece
If a thin fiber unit is used, an adapter provided with the thin fiber unit will be required. Unless the right adapter is connected, the thin fiber unit will not detect targets correctly. (The adapter is supplied with the fiber unit.)
DSC
1 2
When the setting is completed, the setting value is displayed.
Appearance
If the sensitivity difference does not have enough room, flashes for about two seconds after the calibration is complete. The set value is stored in memory even in that case.
„ Maximum Sensitivity Setting Set the sensitivity without a workpiece in the case of the reflective model, and with a workpiece in the case of the through-beam or retro-reflective model.
• To connect the coaxial reflective type fiber unit to the amplifier, connect the single-core fiber to the transmitter side, and connect the multiple-core fiber to the receiver side.
Reflective DSC
1 2
Thrubeam 3 sec or longer
Single-core fiber
Transmitter
Press the SET button for three seconds in the state as shown in the above figure. (Release the button when SET flashes.) The setting value is set slightly higher than the received light intensity at the time of setting the sensitivity.
Receiver
„ Full Auto Calibration
Multi-core fiber
In this mode, the setting value will be set to the mean value of the maximum and minimum incident values obtained within a certain period. Use this mode to detect moving workpieces.
External Input
1 Signals can be input externally by selecting an external input function (page 5, No. 5). 2 The signal can be accepted by short-circuiting the pink wire for 2 ms or more as
1 Press the set button for a minimum of three seconds while the target workpiece is passing the sensing area of the fiber unit. • While the set button is pressed, the sensitivity of the sensor will be set according to the incident values.
shown below for each model (20 ms for OFF). FS-V33P/V34P
Brown *
Brown *
+V
+V Workpiece
FS-V33/V34
Pink
Blue *
0V
Pink
Blue *
DSC
1 2
When the setting is completed, the setting value is displayed.
0V
* FS-V33/V33P only. * Setting using an external input is up to 1 million times. * No inputs are accepted while setting each mode.
• After the setting is completed, the setting value is displayed on the digital monitor.
„ Positioning Calibration
When external calibration is selected, the operation is the same as with the SET button.
1 Press the SET button without any workpiece placed in front of the fiber unit. Workpiece
„ Special Function By performing the following operation, both sensitivity setting and scaling can be performed using external input.Select external calibration (page 5, No. 5) and display scaling (page 6, No. 7).The following is the example when using the % calibration. % calibration
DSC
1 2
Display scaling
Input ON
2 Place a workpiece on the position where you want to perform positioning.
Input OFF
% calibration
Workpiece
3 seconds or less
DSC
1 2
% calibration
Input ON
Edge When the setting is completed, the setting value is displayed.
Input OFF 3 seconds or more
Press the SET button for 3 seconds or longer until the display flashes.
Fine-adjusting Sensitivity The setting value can be directly changed by pressing the manual button.
DSC
1 2
1
2
When extended display (page 6, No. 9) is set for the number of digits to be displayed for the received light intensity
1 Press the manual button quickly once, and check that the setting value flashes. 2 While the setting value is flashing, change the setting value with the Manual button. 2
Page 3
Percentage Calibration
Area Detection Mode This mode is suited to detecting the received light intensity only of a certain range. To set this mode, select the area detection mode at Detection mode selection (page 5, No.4). Received light intensity
This is a calibration method that can set the setting value by percentage with reference to the received light intensity at the time of sensitivity setting. For example, if the target value is set to -10P, the setting value is determined 10% lower than the received light intensity when the SET button is pressed.
1 When selecting the sensitivity setting method (page 5, No. 2), select the % calibration, and set the target value of calibration.
OFF
HI: Upper limit setting value
2 Taking the desired light intensity as a reference (normally without a
ON workpiece), press the SET button.
LO: Lower limit setting value OFF
Set the value so that the upper limit setting value is larger than the lower limit setting value. The unit does not respond when the upper limit setting value is less than or equal to the lower limit setting value.
DSC
1 2
1
2
* While the % calibration is in use, other calibrations (sensitivity setting) cannot be used.
Even when the above condition is satisfied, the unit may not respond when the HI and LO values are close to each other because of hysteresis. Be sure to operate the unit to check whether the values are valid.
Output Selection Either light-ON mode or dark-ON mode is selectable.
„ How to Switch the Upper Limit Setting Value (HI) and the Lower Limit Setting Value (LO)
(1) Press
When the button is pressed, HI or LO and the setting value alternately flash. When the MODE button is pressed while the display alternately flashes, the HI or LO display changes. How to configure the sensitivity setting is the same as when in the normal detection mode.
DSC
1 2
1
2
(2) When Area, Limit setting, Counter, or Alarm is selected, the selection options are NO and NC.
Press (2) within 5 seconds after pressing (1).
Setting the Display Scaling This is the function to adjust the current received light intensity to the ìscaling target value.
Dynamic Sensitivity Correction (DSC) Function
1 When selecting a display value correction function (page 6, No. 7), select the
DSC automatically corrects the setting value according to the changes in the received light intensity when there is no workpiece (output OFF). This function is effective when the light intensity difference is small when judging whether or not there is a workpiece. At Detection mode selection (page 5, No.4), select “Dynamic sensitivity correction mode” beforehand.* How to set the sensitivity is the same as in the normal mode.
display scaling function, and set the target value. (The explanation here deals with the case where the target value is set to 2000.)
2 During the normal display, press the SET button while pressing the MODE button. (Scaling is performed for the current light intensity at this time.)
The DSC indicator illuminates when the DSC function is set. DSC
1 2
DSC indicator
* *
2
The display changes as follows, and the target value (which is 2000) to be set as a scale is displayed.
DSC
1 2
*
1
1
2 DSC
When Light ON is selected, the upper limit of the correctable range is twice as much as the initial setting value. The value is stored in memory even after the power is turned off. The DSC indicator flashes when the light intensity during output OFF greatly fluctuates or the L/D ON selection is inappropriate. In such a case, check the setting again.
1 2
1
2
Ø The scaled value is displayed. DSC
1 2
1
2
Edge Detection Mode The reference light intensity can be set in the following range in reference with the currently received light intensity:
This mode detects the change in the received light intensity during a given period of time. (Set at page 5, No. 4) Rising edge detection
Detects the increase (rising edge) of the received light intensity
Falling edge detection
Detects the decrease (falling edge) of the received light intensity
„ Filter Setting Basically, leave this setting as its initial value. If the passage interval of workpieces is too short for the unit to respond, strengthen the level and try again. The selectable filter level differs depending on the power modes. Filter level
HSP*
FINE
TURBO
SUPER
ULTRA
Default state
5
8
9
9
9
9
Setting range
1 to 5
4 to 8
5 to 9
6 to 9
8 to 9
9 only
Power mode
Minimum value
Maximum value
HIGH SPEED
Approx. 1/20 times
Approx. 16 times
FINE
Approx. 1/20 times
Approx. 16 times
TURBO
Approx. 1/20 times
Approx. 16 times
SUPER
Approx. 1/40 times
Approx. 8 times
ULTRA
Approx. 1/160 times
Approx. 2 times
MEGA
Approx. 1/320 times
Approx. 1 time
If the value exceeds the range, 'TT is displayed and scaling is performed up to the possible range.
• No value can be set when the Edge detection mode is selected. • The value is stored in memory even after the power is turned off. • External input can be used when using FS-V33(P)/34(P) (page 5, No.5).
MEGA
Zero-shift Function
*HSP: HIGH SPEED As the number becomes smaller, the filter becomes stronger, which makes the unit difficult to respond to gradual changes in light intensity.
The Zero-shift function is used to forcibly set the current light intensity to zero.
1 At Display value correction function selection (page 6, No.7), select “Zero-shift function”. 2 When the SET button is pressed while the MODE button is pressed, the current
„ Making Sensitivity Settings light intensity is forcibly set to zero.
The sensitivity is set to maximum when the SET button is pressed quickly once. When the setting value is too low and the unit detects objects other than the workpiece, fine-adjust the setting value to a higher number.
DSC
„ Operation When Switching Outputs Setting
1 2
L-ON
Normally OFF. Turns ON only when the light intensity changes.
D-ON
Normally ON. Turns OFF only when the light intensity changes.
1
2
• This function cannot be used when the Dynamic sensitivity correction (DSC) or Edge detection mode is selected. • The value is stored in memory even after the power is turned off. • External input can be used when using FS-V33(P)/34(P) (page 5, No.5).
Operation
3
Page 4
Display Selection
Key Lock Function
The factory default value is “1” only. Other items can be displayed only after being selected at Display customization selection (page 6, No. 8).
The key lock function disables the operation of all keys.
1 While pressing the MODE button, press the
(1)
Press
DSC
Parameter
DSC
Current received light intensity
MODE
DSC
1 2
MODE
Press
(2)
) button for at least three
(7)
Power mode
Current received light intensity
( seconds.
MODE
Press
1
2
The same steps can be taken to deactivate key lock.
DSC
(6)
By selecting the key lock (page 6, No.12) level (1-3), key operations to be disabled can be changed. (The default value is level 1.)
DSC
Extension display (received light intensity) *1
DSC
MODE
Press
Excess gain (%) Hold value *4
(3) DSC
Bar display *2
Current received light intensity
Bar display *2
(5) DSC
DSC
Excess gain (%) *3
Received light Received light intensity intensity Hold value *4 Hold value *4
*1 When ULTRA/MEGA mode is selected, the current received light intensity can be displayed up to 5 digits. The setting value flashes when the button is pressed once. The setting can be changed by pressing the button while flashing. *2 The excess gain is displayed in a 5% increment from 85 to 115%. *3 The current light intensity for the setting value is displayed in percentage. *4 Holds and displays the peak value and the bottom value.
2
3
° c c c c
Channel selection (p.1)
Channel selection switch c c c
Output selection (p.2)
L/D ON
°
°
°
Menu selection (p.5)
Press and hold MODE
°
°
Level Advanced Operations
2
3
L/D ON + press and hold SET
°
°
°
Display scaling (p.4)
MODE + quickly press SET
° c c
Zero shift (p.4)
MODE + quickly press SET
° c c
Direct access menu (p.7)
Press and hold
°
°
Display OFF/ON (p.6)
L/D.ON + press and hold MODE c c c: °: :
„ User-friendly Functions (Direct Access Menu)
Button 1
Initialization (p.2)
How to reset peak or bottom value (with the (5)/(6) display) The value can be reset by pressing the SET button for 3 seconds or more while pressing the MODE button. With FS-V33(P)/34(P), the value can be reset externally by selecting Reset at External input function selection (page 5, No.5).The peak/bottom value is also reset after the power is turned off.
The hold display (5/6) can be set in detail by pressing the onds or longer.
SET
1
Sensitivity fine-adjustment (p.3)
MODE
Press
Button
Sensitivity Setting (p.3)
MODE
MODE
DSC
Basic Operations
Press
Press (4)
Level
Excess gain (%) Hold value *4 c
Normal operation is possible. Operation is not possible. The settings can be checked but cannot be changed.
PIN Number Key Lock Function button for 2 sec-
The unit can be locked using a PIN number to ensure securer locking effect.
1 While pressing the MODE button, press the
(
) button 10 times.
DSC
Press for 2 seconds or longer. DSC
MODE
Press
Hold display selection Select the setting by pressing the button. . Updates every time the current light intensity is less (or more) than the specified peak and bottom values. . Displays the maximum and minimum peak values since the power is turned on (total number). . Displays the maximum and minimum bottom values since the power is turned on (total number). . Displays the minimum peak value and the maximum bottom value since the power is turned on (total number). . Displays the maximum peak value and the minimum bottom value since the power is turned on (total number).
DSC
1 2
Follow the same step to disable the key lock. Use the same PIN number used for locking.
Note Write down the PIN number in case it is forgotten. The key lock cannot be disabled unless the correct PIN number is used.
DSC for 2 seconds or longer.
DSC
Press to select (see page 5, No. 1).
Press to select (see page 5, No. 5).
2
2 Select a PIN number between 0 and 9999 using the button. 3 Press the MODE button to activate key lock.
The power mode and emission power for the power mode display (7) can be switched by pressing the button for 2 seconds or longer.
Press
1
MODE
Press DSC
MODE
Press
4
Page 5
Operation Configuration
Detection Setting Menu
Normally, this unit can be used in the basic settings. Set other functions as necessary. Pressing
MODE
From the basic menu for 3 seconds or longer displays the basic menu.
Select a function with the button, and press
MODE
DSC to confirm.
MODE
The setting for each item is confirmed when selecting END and pressing
MODE
Press
.
DSC
3
1. Power mode selection 2. Sensitivity setting method selection
Basic setting menu
Press
When VQ(( is selected
When other than VQ(( is selected
3. Timer mode selection 4. Detection mode selection 5. Light emission power selection
Detection setting menu
Timer mode selection Select the setting by pressing the button. Timer OFF OFF-delay ON-delay One-shot ON-delay OFF-delay *1 ON-delay One-shot *1
MODE
DSC
Timer setting Configure setting by pressing the button. Can be set between 0.1 and 9999 ms. When 1 is selected, ON-delay timer is set.
MODE
Press
6. Display value correction function selection 7. Display reverse selection 8. Display customization selection
Display setting menu a b
At Timer mode selection, * other than 1 is selected * 1 is selected b a
DSC
Timer setting 2
9. APC function setting 10. Power save mode setting 11. Key lock level setting 12. Interference prevention function setting
System setting menu
Sets the time of OFF-delay (One-shot).
or
Configure setting by pressing the button. Can be set between 0.1 and 9999 ms.
DSC
MODE
Press
4 Detection mode selection DSC
Basic Setting Menu
MODE
Press
Set the channel selection switch to "1".
1
2
When dSc is selected
When Std or ArEA is selected
Channel selection switch MODE
Press for 3 seconds or longer
Select the setting by pressing the button. . Normal (light intensity) detection mode . Dynamic sensitivity correction mode (see page 3) . Area detection mode (see page 3) . Detects the rising edge of the received light intensity (Edge detection mode) (see page 3) . Detects the falling edge of the received light intensity (Edge detection mode) (see page 3)
DSC
Detection operation selection Select the setting by pressing the button. . Mainly reflective [Light intensity with workpiece > Light intensity without workpiece] (The output is ON when the light enters.) . Mainly thrubeam [Light intensity with workpiece < Light intensity without workpiece] (The output is ON when the light is blocked.)
MODE DSC
Press
1 Power mode (response time) selection Select the setting by pressing the button. . HIGH SPEED: 33 µs . FINE: 250 µs . TURBO: 500 µs . SUPER: 1 ms . ULTRA: 4 ms . MEGA: 16 ms (Can be switched when the power selection switch is set to SEL.)
MODE
Press
DSC
DSC
Correction speed selection Select the setting by pressing the button. 1 to 3 The correction is made faster as the number becomes larger. (Select 1 in normal cases.)
MODE
2 Sensitivity setting method selection
Press
Select the setting by pressing the button. Normal sensitivity setting (see page 2) % calibration (see page 2)
. .
MODE
Press
Power mode
When SEtP is selected
When Std is selected
Level 1 Level 2 Level 3 hSP
7.34s 114.7ms 1.8ms
FinE
52.43s 819.2ms 12.8ms
Turb/SuPr/Ultr/MEGA 104.86s 1.64s
DSC
A
MODE
Press
Percentage calibration target value setting Select the setting by pressing the button. Can be set between –99 and +99%.
25.6ms
When Edge detection is selected DSC
Filter time selection Select the setting by pressing the button. Select larger number (initial state) in normal cases. The selectable level depends on the power modes. (see page 3)
DSC
MODE
Press When StG-Func is selected
Detection When StG-diSP is selected
Display When StG-SYS When End is is selected selected System
Menu end/continue selection Select the setting by pressing the button. . Ends the menu. . Configures detection settings. (Timer, DSC, etc.) . Configures display settings. (Scaling, inversion, etc.) . Configures system settings. (APC, Power Save, etc.)
MODE
Press
When using FS-V33(P)/ 34(P)
When using FS-V33C(P)/ 34C(P) DSC
5 External input function selection MODE
Press
When other than SCAL is selected
End of basic menu display
When SCAL is selected
Select the setting by pressing the button. • Does not use external input. • External calibration • Display scaling Zero-shift • • Reset • Emission stop
DSC
MODE
Press
DSC
Display scaling target value setting Select the setting by pressing the button. The value can be set between 100 and 10000 in the unit of 100. 10000 is displayed as FuLL.
DSC
MODE
Press
6 Light emission power selection Select the setting by pressing the button.
Power mode Display hSP
FinE
Turb/SuPr/ uLtr/MEGA
Normal Approx. 15% of the normal time
A
5
Approx. 11% of the normal time
Approx. 3% of the normal time
Approx. 1.5% of the normal time
Page 6
Display Setting Menu
System Setting Menu
From the basic menu
From the basic menu
DSC
MODE
MODE
Press
Press
DSC
DSC
7 Display value correction function selection MODE
Press When oFF or ShFt is selected
9 S-APC setting
Select the setting by pressing the button. . Not to be used. . Uses the display scaling function. . Uses the zero-shift function.
Configure setting by pressing the . APC is enabled. . APC is disabled.
When SCAL is selected
About APC (Auto Power Control) In normal cases, use the sensor with APC disabled. When APC is enabled, the light intensity is monitored and corrected in order to maintain regular light transmission. If the environment is sufficiently clean, a highly accurate detection can constantly be performed. Note: Long-term use of APC imposes heavier load on the LED than when disabled.
MODE
Press
DSC
MODE
Press
DSC
Display scaling target value setting Configure setting by pressing the button. The value can be set between 100 and 10000 in unit of 100. 10000 is displayed as FuLL.
8 Display reverse selection
DSC
10 Power save mode setting
Select the setting by pressing the button. . Normal display Reverses the display. . Even when the display is reversed, the green light indicates setting values, and the red light indicates received light intensity.
MODE
Press
Configure setting by pressing the button. . Saves power (Turns off the display). While the power save mode is activated, only one segment on the digital monitor remains displayed. . Normal display MODE
To turn all the displays OFF (both digital monitor and operation status indicators) ALL can be selected when is pressed for 3 seconds or longer while “on” is selected. To restore the display from Display OFF, press MODE and L/D ON buttons simultaneously for 3 seconds or longer.
Press
9 Display customization selection
DSC
Select the setting by pressing the button. . Does not customize the display. . Customizes the display.
MODE
Press When no is selected
When no is selected
DSC
11 Key lock level setting (see page 6) Select the setting by pressing the Level 1 Level 2 Level 3
DSC
(1)
. . .
MODE
Normal
Press
MODE
Press (2)
button.
DSC
DSC
Expansion
MODE
Press DSC
(3)
Extension bar
MODE
Press
DSC
(4)
Excess gain (%)
Selectable display setting The items shown left are displayed in order every time the MODE button is pressed. (see page 3) Select the setting by pressing the button. . Adds the item to the selectable display. . Deletes the item from the selectable display.
12 Selecting the number of units of interference prevention Select the setting by pressing the button. . Normal . The number of units of interference prevention is twice as many as in the normal time. (The response time is also twice as long as in the normal time. The detection distance is the same as in the normal time.)
MODE
Press
Back to A of the basic setting.
MODE
Press
Initializing, Saving and Loading the Settings
DSC
(5)
HOLD
„ Initializing the settings
MODE
Press (6)
button.
1 While pressing , press for 5 seconds or longer. 2 Select “T5V“with the button, and press . 3 Select with the button, and press to initialize. L/D ON
DSC
SET
MODE
HOLD Excess gain (%)
MODE
MODE
Press
Default setting Power mode: FAIN Detection mode: Normal Setting value: 50 Output selection: L ON
DSC
(7)
Power mode
MODE
Press
Back to A of the basic setting.
„ Saving the Settings
1 While pressing , press for 5 seconds or longer. 2 Select “5#X'” with the button, and press . 3 Select “;'5” with the button, and press to save. L/D ON
MODE
Reference
When setting each mode, the display returns normal by pressing the button for 3 seconds or longer.
SET
MODE
MODE
„ Loading the setting
1 While pressing , press for 5 seconds or longer. 2 Select “T5V” with the button, and press . 3 Select “=X5V” with the button, and press to load. L/D ON
SET
MODE
MODE
6
Page 7
Channel Selection Switch 2
Special Functions of Channel 2 „ Limit Setting
1
To set channel 2, set the channel selection switch to "2".
2
This function issues a prediction alarm when the light intensity difference is small when judging whether or not there is a workpiece. Two types of limit setting function are available:
Channel selection switch
DSC
Peak limit setting Samples the peak values of setting value while the received light intensity is higher than the output 1 setting value, and issues an alarm when the minimum peak value is lower than the output 2 setting value.
MODE
Press for 3 seconds or longer
DSC
Bottom limit setting Samples the bottom values of setting value while the received light intensity is lower than the output 1 setting value, and issues an alarm when the maximum bottom value is higher than the output 2 setting value.
Output 2 function selection Select the setting by pressing the button. • Normal (light intensity) detection • Used as limit setting output. • Used as counter output. • Used as alarm output.
Peak hold minimum value When Std is selected
When LiMt is selected
Setting value when PEAk is selected 1ch value Setting value when botm is selected
DSC
Limit function setting Select the setting by pressing the button. • Sets the peak value. • Sets the bottom value.
MODE
Press
Bottom hold maximum value
1ch output
DSC
(Instantaneous display)
2ch output (PEAk setting value) 2ch output (botm setting value) DSC
(Normal display)
Channel 2 normal display when using the limit setting function DSC
When Cnt is selected
Alternate display
DSC
Counter function setting Select the setting by pressing the • Over count mode 1 • Over count mode 2 • Auto reset mode
MODE
Press When ovr1/ovr2 is selected
When Auto is selected button.
DSC
Setting value Peak/bottom value
How to reset the peak/bottom value The value can be reset by pressing the SET button for 3 seconds or more while pressing the MODE button. With FS-V33(P)/34(P), the value can be reset externally by selecting Reset at External input function selection (page 5, No.5). The peak/bottom value is also reset after the power is turned off.
DSC
One-shot time setting Select the setting by pressing the button. The value can be set between 0.1 and 9999 ms.
MODE
Press
Pressing the button can adjust the setting value.
„ Counter Function
DSC
(Instantaneous display)
This mode counts the output (edge of OFF to ON) of output 1, and compares it with the setting value. The following three count modes are available:
DSC
(Normal display)
Over counter 1
Q7T
When AlrM is selected
Over counter 2
The output turns ON with the value higher than the setting value.The counter value increases until it is reset. The output turns ON only when the value is the same as the setting value.The count value increases until it is reset.
DSC
#XVQ
(Instantaneous display)
One-shot output is performed when the value is the same as the setting value, and the count value is automatically reset.
Auto reset
DSC
(Normal display)
Channel 2 normal display when using the counter function DSC
DSC
(Instantaneous display)
Alternate display DSC
DSC
(Normal display)
Setting value
Count value
Pressing the button can adjust the setting value. The setting value can be displayed up to 65.535 on the Extension display (page 6, No. 9).
How to reset the count value The value can be reset by pressing the SET button for 3 seconds or more while pressing the MODE button. With FS-V33(P)/34(P), the value can be reset externally by selecting Reset at External input function selection (page 5, No.5). The count value is also reset after the power is turned off.
„ Alarm Output Function When using the APC function, the alarm output is issued when the load on the LED is too large.The alarm output is also issued when the DSC indicator is flashing (refer to Dynamic Sensitivity Correction (DSC) Function on page 4). Channel 2 normal display when using the alarm output function
Normal DSC
7
When the load on the LED is greater DSC