Digital Fiber Sensor 2-Output Type FS-V33(P)/V34(P)/V33C(P)/V34C(P) Instruction Manual, page 8

Page 8 of 8

The original document is the PDF (2.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Keyence FS-V33CP

Page 8

Specifications

Hints On Correct Use Cable type

• Do not wire the amplifier line along with power lines or high-tension lines, otherwise the sensor may malfunction or receive damage due to noise. • When using a commercially available switching regulator, ground the frame ground terminal and ground terminal. • Do not use the FS series outdoors, or in a place where extraneous light can enter the light-receiving surface directly. • Due to the individual dispersion of characteristics and the difference in fiber unit model, the maximum sensing distance or displayed value of all the units are not the same. • If the sensor is used in S-APC mode for a long time, the LED indicators will be imposed with a heavy load. In that case, the sensor will be automatically set to ACC mode where the current consumption of the sensor for light emission will be constant, and “END APC” will be displayed. The sensor can be continuously used in this case. Replace the sensor, however, if highly precise detection is required.

Connector type

Type Main unit

Sub unit

Main unit

Sub unit

NPN output

FS-V33

FS-V34

FS-V33C

FS-V34C

PNP output

FS-V33P

FS-V34P

FS-V33CP

FS-V34CP

Model Light source Control output (2 outputs) *1

Red 4-element LED (peak wave length: 640 nm typ.)

NPN output

Response time

NPN open collector 24 V 100 mA (2CH total) max

PNP output

PNP open collector 24 V 100 mA (2CH total) max

ON/OFF output

33 μs (HIGH SPEED)/250 μs (FINE)/500 μs (TURBO)/ 1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) Calibration/Scaling/ Zero-shift/Reset/Emission stop(input time ON: 2 ms, OFF: 20 ms)

Control input

WARRANTY

–

KEYENCE products are strictly factory-inspected. However, in the event of a failure, contact your nearest KEYENCE office with details of the failure.

1. WARRANTY PERIOD Normal time Number of interference prevention units When double is set *2

Power mode

HIGH SPEED

FINE

TURBO/SUPER/ULTRA/MEGA

Number of units required to prevent interference

0 units

4 units

8 units

Power mode

HIGH SPEED

FINE

TURBO/SUPER/ULTRA/MEGA

Number of units required to prevent interference

0 units

8 units

16 units

Power voltage

Operating ambient luminance

NPN output

PNP output

830 mW max. (Using 24 V, 35 mA max., using 12 V, 45 mA max.)/ Power saving 660 mW max. (Using 24 V, 27 mA max., using 12 V, 32 mA max.)

Incandescent lamp

20,000 lx max.

Sun light

30,000 lx max.

Operating ambient temperature

3. PRODUCT APPLICABILITY

35 to 85% RH (No condensation)

Vibration resistance

10 to 55 Hz Compound amplitude 1.5 mm, 2 hours for each of XYZ axes

Shock resistance

500 m/s2 3 times for each of XYZ axes

Material

*2 *3

KEYENCE products are designed and manufactured as general-purpose products for general industries. Therefore, our products are not intended for the applications below and are not applicable to them. If, however, the purchaser consults with us in advance regarding the employment of our product, understands the specifications, ratings, and performance of the product on their own responsibility, and takes necessary safety measures, the product may be applied. In this case, the warranty scope shall be the same as above. • Facilities where the product may greatly affect human life or property, such as nuclear power plants, aviation, railroads, ships, motor vehicles, or medical equipment • Public utilities such as electricity, gas, or water services • Usage outdoors, under similar conditions or in similar environments

-10 to +55 °C (No freezing)

Operating ambient humidity

*1

(1) If a failure attributable to KEYENCE occurs within the abovementioned warranty period, we will repair the product, free of charge. However, the following cases shall be excluded from the warranty scope. • Any failure resulting from improper conditions, improper environments, improper handling, or improper usage other than described in the instruction manual, the user’s manual, or the specifications specifically arranged between the purchaser and KEYENCE. • Any failure resulting from factors other than a defect of our product, such as the purchaser’s equipment or the design of the purchaser’s software. • Any failure resulting from modifications or repairs carried out by any person other than KEYENCE staff. • Any failure that can certainly be prevented when the expendable part(s) is maintained or replaced correctly as described in the instruction manual, the user’s manual, etc. • Any failure caused by a factor that cannot be foreseen at a scientific/technical level at the time when the product has been shipped from KEYENCE. • Any disaster such as fire, earthquake, and flood, or any other external factor, such as abnormal voltage, for which we are not liable. (2) The warranty scope is limited to the extent set forth in item (1), and KEYENCE assumes no liability for any purchaser’s secondary damage (damage of equipment, loss of opportunities, loss of profits, etc.) or any other damage resulting from a failure of our product.

12-24 VDC, Ripple (P-P): 10% max, Class2 Normal: 710 mW max. (Using 24 V, 29 mA max., using 12 V, 40 mA max.) Power saving: 540 mW max. (Using 24 V, 22 mA max., using 12 V, 28 mA max.)

Weight (including cable)

2. WARRANTY SCOPE

Timer OFF/Off-delay/On-delay/One-shot/ On-delay Off-delay/On-delay One-shot (Timer time: 0.1 ms to 9999 ms)

Timer function

Power consumption *3

The warranty period shall be for one year from the date that the product has been delivered to the location specified by the purchaser.

Main unit, housing material: Polycarbonate Approx. 80g

Approx. 70g

E 1040-1

Approx. 22g

When several units are connected, the operating ambient temperature varies depending on the number of units to be connected. When connecting several units, be sure to mount the units on the DIN rail (mounted on a metal plate), and keep the output current within 20 mA. When 1 to 2 units are connected: -10 to +55 °C, When 3 to 10 units are connected: -10 to +50 °C, When 11 to 16 units are connected: -10 to +45 °C When using the 2-output type, count one unit as two units. When double is set, the response time is twice longer. When using the 2-output type, be careful with the number of units to be connected. When using the HIGH SPEED mode, the power consumption increases by 160 mW (7 mA).

Error Displays and Corrective Actions Error display

Cause

Corrective action

'T=

Overcurrent is flowing in the control output.

Check the load and return the current within the rated value.

'T'

Failed to write/read the internal data.

Perform initialization (p.2).

The load on the light source is large.

If highly precise detection is required, replace the sensor.

Copyright (c) 2010 KEYENCE CORPORATION. All rights reserved.