Visual KV Series User's Manual 1: Installation, pages 101 to 102

Pages 101 to 102 of 102

The original document is the PDF (964 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Keyence KV-E4X

Page 101

2.2 Connecting Visual KV Series Expansion Units

An expansion unit operates at a cycle of 800 µs without depending on the scan time. When performing input while setting the input time constant of an expansion unit to 10 µs, or when synchronizing the output of a basic unit with the output of an expansion unit, pay strict attention to the following contents.

When inputting

Visual KV Series

2.2.4 Transferring I/O Information between Expansion Units and the Basic Unit

■ When the scan time is longer than 800 µs (communication cycle) plus 10 µs (input time constant) Set the input signal ON time equal to or longer than the scan time. Scan time Receive

Communication cycle in expansion unit Input signal

Receive

Receive

ON OFF

Incomplete receive

OK

■ When the scan time is equal to or shorter than 800 µs (communication cycle) plus 10 µs (input time constant) Set the input signal ON time to 810 µs or longer. Scan time Receive

Communication cycle in expansion unit

Receive

ON

Input signal OFF

Incomplete receive

OK

In the case of output The output of an expansion unit is delayed by a maximum of 800 µs from the output of a basic unit. When synchronizing the output of an expansion unit with the output of a basic unit, pay strict attention to the communication cycle. ON

Output of basic unit Output of expansion unit

OFF ON

800µs

800µs

OFF

Note: When the output ON time is 800 µs or shorter, the output may be aborted.

Chapter 2 System Installation

1-77

12

Page 102

2.3 Inspection and Maintenance

2.3 Inspection and Maintenance Visual KV Series

This section describes the inspection and maintenance procedures for units.

2.3.1 Inspection While basic units and other units have been used for a long period of time, the connector connection area may become loose, the battery may wear out, or another nonconformity may occur in operation. To avoid any nonconformities, inspect the basic units, other units, and the wiring periodically. The major inspection items are as follows. •

Check to ensure that the connector connection area is not disconnected or loose.

•

Check to ensure that terminals on terminal blocks are not loose.

•

Check to ensure that the wiring cables among units and each equipment are not damaged.

2.3.2 Maintenance While basic units and other units have been used for a long period of time, dirt will adhered. Wipe off any collected dirt with a clean, dry cloth. Wipe off any dust and dirt that has collected on small and narrow portions with cotton swabs.

2 CAUTION

1-78

Be sure to turn off the power before starting any inspection or maintenance of the units.

Chapter 2 System Installation