Page 9

Heavy duty construction in an ultra-light package

Test switch for easy adjustment The test mode allows you to confirm the optimal reading position at the point of installation by simply pressing a button. This valuable feature of the BL-600 results in faster installation and maintenance.

Thanks to its die-cast magnesium casing, the BL-600 is not only ultra light and compact, but also solidly constructed.

Exceptional resistance even in severe environments

5-bar LED display The BL-600 indicates the reading ratio (decoding rate/100 scans) in real time using a five-bar LED display. Current reading status can be checked at a glance, helping to prevent reading errors before they occur. *Reading ratio can be output to computers.

The highly resistant construction of the BL-600 passes the demanding IP-65 environmental standard for sensors. The BL-600 offers excellent protection in harsh or dirty environments and can be installed in almost any location.

5-bar LED reading status indicator

Easy maintenance

100% of max. rate 40% of max. rate

The flat reading surface of the BL-600 Series greatly reduces the tedious maintenance often involved with bar code readers.

Reading error

Applications

❚ Specifications Model Type Reading direction Scanning method 1. Light source Maximum output Pulse duration Class Reading distance

Wafer carriers

Medical

PC media drive

Thanks to the AGC function, the BL-600 can reliably read PFA-coated bar code labels even at extreme angles. * A special model for a 300 mm wafer load ports (SEMI E15.1 fully supported) is also available.

With its compact body and high speed reading capability, the BL-600 can easily read the bar codes on medical specimens.

Even with vibrations and unevenness, the BL-600 performs accurately and reliably.

BL600

BL-601

BL-600HA BL-601HA High-resolution

Standard Front Single

Raster

BL-650HA BL-651HA High resolution, side scanning type Side Single Raster

Single Raster Visible semiconductor laser (Wavelength: 650 nm) 1.5 mW FDA: 56 µs, IEC: 99 µs FDA: 56 µs, IEC: 82 µs FDA Class II, IEC Class 2 2.95" to 12.99" 75 to 330 mm (When narrow bar width is 0.04" 1.0 mm) 2.17" to 7.48" 55 to 190 mm (When narrow bar width is 0.02" 0.5mm) 1.77" to 6.89" 45 to 175 mm (When narrow bar width is 0.02" 0.5mm) 0.007" to 0.04" 0.19 to 1.0 mm 0.005" to 0.04" 0.125 to 1.0 mm Readable bar width 2. * 0.01" to 0.04" 0.25 to 1.0 mm for CODE 93 * 0.006" to 0.04" 0.15 to 1.0 mm for CODE 93 and CODE 128 and CODE 128 9.84" 250 mm (When reading distance is 11.02" 280 mm) 6.14" 156 mm (When reading distance is 6.85" 174 mm) 6.69" 170 mm (When reading distance is 6.10" 155 mm) Largest readable label width 3. PCS 0.6 or more (Reflectance of white part: 75% or more) Scanning rate 500 scans/sec Target code CODE39, ITF, Industrial2-of-5, COOP2-of-5, Codabar, CODE128, EAN-128, CODE93, EAN/UPC(A•E) Number of readable digits 32 digits max. 4. Trigger input Non-voltage input (contact, solid-state), TTL input is also possible. Serial interface RS-232C (Refer to the data of BL-700 Serial Interface in page 9 for details.) Output form NPN Rated load 24 VDC, 30 mA OK/NG output Leakage current (at OFF) 0.1 mA max. Residual voltage (at ON) 0.5 V max. Enclosure rating IP-65 Ambient light Sunlight: 10,000 lux, Incandescent lamp: 6,000 lux EnvironAmbient temperature 0 to +45°C (32 to 113°F), No condensation mental 35 to 85%, No condensation resistance Relative humidity Operating atmosphere No dust or corrosive gas present Vibration 10 to 55 Hz, 0.06" 1.5 mm double amplitude in X, Y, and Z directions, 2 hours respectively Power supply voltage 5 VDC ±5% Power rating Power consumption 330 mA max. Weight Approx. 115 g Approx. 130 g 1. Raster width: BL-601: 0.30" ±0.07" (7.1 ±1.8 mm) (When reading distance is 4.72" (120 mm)), BL-601HA: 0.22" ±0.06" (5.5 ±1.4 mm) (When reading distance is 3.54" (90 mm)), BL-651HA: 0.22" ±0.06" (5.5 ±1.4 mm) (When reading distance is 2.56" (65 mm)) 2. Reading bar width indicates the range of readable narrow bar width when the bar code type is CODE39. 3. Maximum reading label width includes the bar code margin (quiet zone). 4. When start/stop character of CODE128 is CODE-C, up to 64 digits are allowed. Note: The internal BL settings are written to the built-in EEPROM (erasable up to 100,000 times).

09

Page 10

BL-180 Series

CCD BAR CODE READER

Ultra Small Size... Half the Size of a Business Card The BL-180 Series ultra-small CCD bar code reader is easily mounted in any device, allowing the complete system to be downsized. Despite the small size, it features a built-in decoder and reads labels as wide as 3.15" (80 mm).

STABILITY LED for easy mounting The BL-180 Series is the first bar code reader in the world to feature a STABILITY LED indicator. The optimal mounting position can be determined quickly and easily. Moreover, reading errors can be prevented by checking the reading performance rate or the decode count output.

The LED shows the performance rate with three colors: green, orange, and red.

Fastest-in-class, 500 scans per second The BL-180 Series is the first CCD bar code reader that achieves a laser-typelevel, 500 scans per second. The reliability is dramatically improved with the high-speed processing circuit developed by KEYENCE.

10

Front-view type BL-180

Side-view type BL-185

Page 11

Ultra-small body reads labels as wide as 3.15" (80 mm).

Reads bars as narrow as 0.005" (0.125 mm)

The BL-180 Series is small in size but reads wide. KEYENCE’s original optical technology achieves 3.15" (80 mm) of readable label width.

The BL-180 Series offers the best reading capability of all other CCD bar code readers in the world. It can read bars as narrow as 0.005" (0.125 mm), being the ideal readers for today’s increasingly miniaturized bar codes.

3.15" (80 mm)

Scans bars as narrow as 0.005" (0.125 mm)

Sufficient reading depth of ±0.39" (±10 mm) Reading is reliable regardless of the vibration or position of the targets. The original optical technology and the high-intensity LED achieve a reading depth of ±0.39" (±10 mm), resulting in a stable reading performance.

±0.39" (±10 mm) BL-180

Reading depth

Applications Medical applications

PC board mounting process

Shelf management

The BL-180 Series excels at reading bar codes on specimen containers with its reading width of 3.15" (80 mm).

The compact body and high-speed reading capability of the BL-180 Series makes it ideal for reading bar codes on PC boards or wafer carriers.

The compact body can be mounted easily anywhere in the shelf.

❚ Specifications Model Reading direction Light source/Light receiving element Scanning distance Readable bar width 2. Largest readable label width PCS Scanning rate Target code Number of readable digits Trigger input Applied standard Synchronization Transmission code Serial Baud rate interface Data length Parity check Stop bit length Output form Rated load OK/NG output Leakage current (at OFF) Residual voltage (at ON) Ambient light Environ- Ambient temperature mental Relative humidity resistance Operating atmosphere Vibration Power supply voltage Power rating Current consumption Weight

BL-180 Front

BL-185 Side

LED/CCD image sensor 1.30" ±0.39" 33 ±10 mm 1. (Using narrow bars of at least 0.007" 0.19 mm in width) 0.005" to 0.04" 0.125 to 1.0 mm 3.15" 80 mm 3. (Using narrow bars of at least 0.007" 0.19 mm in width) 0.45 or more (Reflectance of white part: 75% or more) 500 scans/sec CODE39, ITF, Industrial2-of-5, COOP2-of-5, Codabar, CODE128, EAN/UPC(A•E) 32 digits Non-voltage input (contact or solid-state), TTL input is also possible. RS-232C Start-stop ASCII 600/1,200/2,400/4,800/9,600/19,200/31,250/38,400 bps 7/8 bits None/Even/Odd 1 bit/2 bits NPN 24 VDC, 100 mA 0.1 mA max. 0.5 V max. Sunlight, Incandescent lamp: 10,000 lux, Fluorescent lamp: 3,000 lux. 0 to +40°C (32 to 104°F), No condensation 35 to 85%, No condensation No dust or corrosive gas present 10 to 55 Hz, 0.06" 1.5 mm double amplitude in X, Y, and Z directions, 2 hours respectively 5 VDC ±5% 4. 300 mA max. Approx. 165 g Approx. 180 g

1. 1.30" ±0.20" (33 ±5 mm) when the narrowest bar is less than 0.007" (0.19 mm). 2. Readable bar width indicates the range of the narrowest readable bar. 3. 2.36" (60 mm) when the narrowest bar is less than 0.007" (0.19 mm). 4. Use a stable power supply of 5 VDC ±5%. The BL-U1 special power unit is available as an option. Note: The internal BL settings are written to the built-in EEPROM (erasable up to 100,000 times).

11

Page 12

D V- 9 0

NEW

AUTO ID DATA CONTROLLER

Automatic Bar Code Data Verification and Evaluation Immediate Verification/Evaluation of Bar Code Data

Two serial ports & USB interface are standard

The DV-90 compares the data read with a bar code reader to the data registered in advance (preset data) for verification. The evaluation result is output in parallel *. Setting is easy without any need for difficult programming.

Both of the two serial ports can be used to connect BL Series units (bar code readers) respectively. It is also possible to select a port from PORT 1 or 2 to verify data for each preset number. Moreover, a USB interface is featured as standard. Consequently, two BL Series units and a PC can be connected simultaneously.

* The output can be selected from bit, binary, and BCD. Up to 900 pieces of master data can be registered.

PNP output type available Readout data

ABC GHI DEF

A PNP open-collector output model is also available (DV-90PE)

Output NO. Preset data

001 002 003 004

ABC DEF GH I JKL

DV Quick Setup Code The included software allows users to setup the DV-90 by simply scanning the bar codes which are printed out from the software. Output 001 003 002

Bar code reader

DV-90

Easy preset registration The preset bar code data can be registered easily by simply scanning the bar codes applied on products or instruction sheets. Additions or a change of products can be registered easily without changing the program.

▼ 12

STEP1

Comparison result

* Up to 900 presets can be registered.

See page 20 for setup software.

DV-90 INITIALIZE

STEP2

Page 13

Bar Code Data Verification Functions DV-90 Series Verification Functions Normal Verification Compares readout data to the preset data and outputs the result with a corresponding output number.

Lamp

USB

PLC

Buzzer

Step Verification

Synchronization input

Parallel output

Compares two consecutive data readings and outputs whether the two data strings match or do not match.

Computer

Photoelectric sensor, etc

Bar Coder Reader

Active Verification

BL Series

Compares the readout data to one selected preset data and outputs whether they match or do not match.

DV-90

3-point A Verification

PLC

Compares the combinations of three pieces of data and outputs whether the combinations match or do not match.

PORT 1 RS-232C

PORT 2 RS-232C

3-point B Verification

Computer

Compares three bar codes in turn and determines that they are picked in the correct order.

BL Series

Applications Prevent Mixing

Changeover

POKA-YOKE

Wrong products can be effectively prevented from entering the line.

The DV-90 will handle product Make sure that the correct instruction differentiation and provide accurate sheet is included with the product. instructions to the upper (control) devices.

❚ Specifications DV-90NE (NPN output type), DV-90PE (PNP output type) BL-700/600/500/180/80RKE 900 max. Flash ROM (Rewritable: 100,000 times)

Model Applicable bar code reader Registered preset data number Memory backup Input (4 points) • Trigger input (2 points) • Unlock input • Remote input

I/0 terminal

Output (16 points) • Out 1 through 12 • OK output • NG output • Read error output • Quality error output

PORT1 (For connecting bar code reader) Serial interface

PORT2 (For connecting PC, PLC, or bar code reader) USB (Special for connecting PC)

Power output

Power for bar code reader Power for sensor

Enclosure rating Environmental Ambient temperature Relative humidity resistance Operating atmosphere Power supply voltage Power rating Current consumption Weight

Rated input voltage Maximum OFF current Output form Rated load Leakage current at OFF Residual voltage at ON Applied standards Synchronization Baud rate Data length Parity check Stop bit length

10 to 26 VDC, 10 mA, class 2 1.0 mA DV-90NE: NPN Open-collector DV-90PE: PNP Open-collector 30 VDC, 100 mA 0.1 mA max. Less than 1 V RS-232C Asynchronous 600/1,200/2,400/4,800/9,600/19,200/31,250/38,400/57,600/115,200 bps 7/8 bits None/Even/Odd 1 bit/2 bits USB 2.0 (B type) (Communication speed fixed to 115,200 bps) 5 VDC ±5%, 1,100 mA max. (at the ambient temperature of 0 to +40ºC (32 to 104°F)) 850 mA max. (at the ambient temperature of 40 to +50ºC (104°F to 122°F)) 24 VDC ±10%, 250 mA max. IP-65 (only the front panel when panel-mounted) 0 to +50ºC (32 to 122°F), No condensation 35 to 85%, No condensation No dust or no corrosive gas present 24 VDC ±10%, class 2 850 mA max. Approx. 360 g

13

Page 14

BL-V35E

BAR CODE DISPLAY INTERFACE

Converts Bar Code Data into ON/OFF Signals Once the preset bar code data is entered, the BL-V35E compares the readout data with the preset data and produces a parallel output (bit, binary, or BCD) for the matched registration number.

Up to 399 bar codes can be preset To preset a bar code, just read it with the BL-V35E. No difficult programming is required. A bar code system can be implemented with extremely simple operation and at low cost.

Compatible with all of KEYENCE’s bar code readers The BL-V35E can be connected directly with all of KEYENCE’s bar code readers. The BL-V35E provides added convenience with its built-in timing inputs.

BL setup software is available Easy-to-read character display The data reference function instantly converts the bar code data read into item names. Products can be quickly and reliably checked.

PLC link When the BL-V35E is connected to a PLC, the bar code data read can be directly written to the PLC data memory. It does not require a personal computer or tedious communication programs.

14

The software not only allows the preset and reference data to be loaded but also saved.

Setup software BL-H35W (optional)

Page 15

Packed with Convenient Features for Practical Applications ■ Bar code samples

Step verification feature The step verification feature compares the first and second readout data, and outputs whether or not both data match. This is convenient to compare slips with actual items.

COLA

Serial Number check feature

CHOCOLATE

The serial number check feature determines whether bar code labels are properly printed in serial order. This is ideal for checking the serial numbers of products. MILK

Preset-active feature The preset-active feature checks whether the readout data matches one of the preset data (399 max.) and outputs whether or not the two data match. This is convenient for changeovers while checking for the mixing of different products.

APPLE

ORANGE

Applications Smooth sorting

The preset number for the readout bar code can be output from the parallel port, enabling smooth sorting.

Checking for the mixing of different products

Instructions for operation or pickup

The readout bar code data is compared with the preset data, and a matched or unmatched signal can be output without a PC.

The readout bar code data can be sent directly to a PLC without any complicated communication programming.

❚ Specifications Model Number of storable preset data Memory backup Input (7 points) 1. Output (12 points) Parallel • OK output (Matched) interface • NG output (Unmatched) • OUT1 to OUT10 outputs (Output No.) • Serial port 1 (for connecting an external device 2. or bar code reader)

Serial interface • Serial port 2 (special for connecting a bar code reader) Power supply for bar code reader Environ- Ambient temperature Ambient humidity mental resistance Vibration Power supply voltage Power rating Power consumption Dimensions Panel cutout Weight

BL-V35E 399 data max. Lithium battery (service life: approx. 10 years at 25°C (77°F)) Non-voltage input (contact, solid-state) Output form NPN Rated load 30 VDC, 100 mA Leakage current (at OFF) 0.1 mA max. Residual voltage (at ON) Less than 1 V Conforms to RS-232C approved by EIA Applied standard Start-stop (Full duplex) Synchronization ASCII Transmission code 600 to 38400 bps Baud rate 7/8 bits Data length None/ Even/ Odd Parity check 1 bit/2 bits Stop bit length 5 V ±5%, 750 mA max. 0 to +50°C (32 to 122°F), No condensation 35 to 85%, No condensation 10 to 55 Hz, 0.06" 1.5 mm double amplitude in X, Y, and Z directions, 2 hours respectively 100 to 120 VAC, 50/60 Hz 20 VA 7.56" x 3.78" x 2.01" 192 x 96 x 51mm +1 +0.04" +0.8 +0.03" 3.62" 0 x 7.40" 0 92 0 x 188 0 mm Panel thickness: 0.24" 6 mm max. Approx. 600 g

1. Two synchronization inputs for bar code readers connected to serial 1 and 2. Five inputs for the same operation as that of the main keys( Preset , 2. Can be connected to a personal computer, a PLC (programmable logic controller), or a serial printer.

,

, Cancel , Enter ).

15

Page 16

N-400

MULTI-DROP CONTROLLER

Multi-drop Link can be Established Easily. Up to 31 bar code readers can be controlled with a single host computer. The N-400 controls the communication between the bar code readers, partially eliminating the need for programming the host computer.

N-400 Multi drop controller

BL-700/ BL-600/ BL-180

Host computer

N-400 TEST

Special power supply unit N-48 (DC type) BL-U1 (AC type)

RS-232C

SD

READER

POWER

SD

READER

RD

POWER

SD

RD

POWER

SD

RD

POWER TIMING

READER

RS

CS

SD RD RS-485

RS-232C

RD

TERMINATOR TERMINATOR

TERMINATOR

ON OFF

TERMINATOR

ON OFF

ON OFF

ON OFF

N-48

N-48

RS-232C

N-48

Up to 31 bar code readers can be controlled simultaneously. (Maximum total cable extension: 1.2 km) RS-485

Automatic polling 1234

No data

No data

%P01-1234

No data

5678 4321

8901

N-400

N-400

ID No.1

ID No.2

ID No.3

N-400

The N-400 inquires for data (polling) to the connected bar code readers all the time. The data is stored temporarily in the internal memory (sending buffer) of the N-400. 16

••••••••• %P02-5678 %P02-4321 %P03-8901

ID No.1

ID No.2

ID No.3

N-400

The N-400 polls the connected bar code readers. The N-400 receives data and sends it to the host computer immediately.