For the Keyence N-400

Page 17

Multiple Scanning Heads Multi-head mode

Mutual interference prevention function

The N-400 controls several bar code readers as if they were a single unit, without using a host computer. This mode is useful when several bar code readers are used simultaneously to read bar code labels pasted on various positions.

The N-400 controls several bar code readers so that they scan alternatively, eliminating mutual interference. This function is useful when several bar code readers must be installed close to each other to read a label with several bar codes.

Special power supply unit N-48 BL-U1

Special power supply unit N-48 BL-U1 RS-485

Host computer N-400 TEST

N-400

RS-232C

SD

RD

POWER TIMING

RS-232C

TERMINATOR ON

RS

CS

SD RD RS-485

RS-232C

BL-700/ BL-600/ BL-180

Host computer N-400 TEST

N-400

RS-232C

SD

RD

POWER TIMING

RS-232C

TERMINATOR

OFF

RS

CS

SD RD RS-485

RS-232C

ON OFF

Sensor for synchronization

Sensor for synchronization

BL-700/BL-600/ BL-180

Features of the N-400 Greatly reduced programming for the host computer

Setting change of bar code readers

Up to 31 bar code readers can be controlled with a single host computer.

You can change various settings of bar code readers using the N-400, such as adding bar code types or changing the maximum code length to be read.

24 KB memory (sending buffer) featured as standard The internal buffer can store up to approximately 3500 pieces of five-digit data. In the event of an accident the data is retained even when the host computer is turned off.

Reading test of each bar code reader You can use the handy functions of the BL Series, as well as the test mode, through the N-400. This allows remote access to the bar code readers to check settings and ensure correct operation.

Built-in test mode for connection check The N-400 features a test mode to enable an easy check of the connection with the bar code readers. No special programming or PC is required.

❚ Specifications Model N-400 BL-700 Series, BL-600 Series, BL-180 Series Connectable bar code reader 15 to 26 VDC, 10 mA max. Rated input Trigger input 1.0 mA Max. OFF current RS-232C Applied standards Start-stop (Full-duplex) Synchronization ASCII Transmission code 600/1,200/2,400/4,800/9,600/19,200/31,250/38,400 bps RS-232C Baud rate 7/8 bits Data length Even/Odd/None Parity check 1 bit/2 bits Stop bit length RS-485 Applied standards Start-stop (Full-duplex) Synchronization ASCII Transmission code 600/1,200/2,400/4,800/9,600/19,200/31,250/38,400 bps Baud rate 7/8 bits Data length RS-485 Even/Odd/None Parity check 1 bit/2 bits Stop bit length 31 Max. number of connectable units 1.2 km Max. total extension distance Environ0 to +50°C (32 to 122°F), No condensation Ambient temperature mental 35 to 85%, No condensation resistance Relative humidity 24 VDC +10% Power supply voltage Power -20% rating 140 mA max. Current consumption Weight Approx. 180 g

❚ Dimensions

1.07" 27.3 RS-232C

4.41" 3.94" 3.54" 112 100 90

SD

RD

RS

CS

1.39" 35.4

POWER TIMING SD RD RS-485 RS-232C

TERMINATOR ON OFF

1.57"40 2.36"60

ø0.20 4 x ø5 mounting hole

2.01" 51

17

Page 18

BL-80 Series

CCD HANDHELD BAR CODE READER

3.23" (82 mm)

Safe for the eyes

Directly connects to a PC

Uses LED’s, not a laser as the light source. This eliminates possible danger to the user’s eyes, preventing accidents from happening.

Transmitting bar code data is as easy as connecting the reader to a PC. There is no need for software.

Low price

Simple set up with data menu

This super-high-quality low-priced product is made possible through a streamlined manufacturing system integrating all processes from development to production.

Set-up is easily achieved by simply scanning the bar code menu located in the manual.

Superb reading ability. The BL-80 Series can reliably read bars as narrow as 0.005" (0.125 mm).

❚ Specifications Model Interface Connector type Light source Reading distance Readable bar width CODE39, ITF, IATA, Industrial 2 of 5, Codabar Resolution EAN/UPC CODE93, CODE128, EAN-128 Scanning rate Target codes Ambient temperature Relative humidity Power supply voltage Current consumption Weight Cable length

BL-80VE PS/2 Keyboard Interface External PS/2 keyboard Mini-DIN 6-pin or DIN 5-pin

BL-80RKE RS-232C

RS-232C general purpose

For Keyence products

D-sub 9-pin (Female) Red LED 0" to 0.71" 0 to 18 mm 3.23" 82 mm (included quiet zone)

0.006" 0.15 mm

0.005" 0.125 mm

0.01" 0.25 mm (0.8 times) 0.006" 0.15 mm 100 scans/second EAN/UPC (A•E), CODE39, Codabar, ITF, Industrial2-of-5, IATA, CODE93, CODE128, EAN-128 0 to +40°C (32 to 104°F), No condensation 35 to 85%, No condensation 5 VDC ±5% 5 VDC ±5% 1. Less than 95 mA Less than 175 mA Approx. 140 g (without cable) 6.6' 2.0 m 5.3' 1.6 m (coiled) 0.007" 0.17 mm

1. AC adapter is included with BL-80RE. The power supply voltage for the AC adapter is 120 VAC (60 Hz, 7 W)

18

BL-80RE

Page 19

Peripheral devices Power supply units

N-42

N-48

BL-U1

BL-U2

❚ Specifications Model Conversion interface Connectable bar code reader Power supply for bar code reader Input rating Trigger input Max. OFF current

N-42 N-48 RS-232C RS-485 (Level conversion) RS-422A (Level conversion) BL-700 Series, BL-600 Series, BL-180 Series 5 VDC ±5% (630 mA) 15 to 26 VDC, 10 mA max. 1.0 mA RS-485(Max. number of connectable units: 31) RS-422A (Max. total extension distance: 1.2 km ) (Max. total extension distance: 1.2 km) RS-232C

Interface Power rating

24 VDC +10% -20% 260 mA max. Approx. 100 g

Power supply voltage Current consumption

Weight Model Connectable bar code reader Power supply for bar code reader Power supply for sensor Trigger Input rating input Max. OFF current

BL-U2 BL-700 Series, BL-600 Series, BL-180 Series

5 VDC ±5% (1.5 A) 12 V ±10% (300 mA) 8.5 to 30 VDC, 10 mA max. 0.5 mA

5 VDC ±5% (630 mA) 8.5 to 26 VDC, 10 mA max. 1.0 mA

RS-232C, RS-422A, RS-485 multi-drop (Max. number of connectable units: 31) (Max. total extension distance: 1.2 km) 100 to 240 VAC (50/60 Hz)

Interface Power rating

BL-U1

Power supply voltage Power consumption Current consumption

Conforms to RS-232C approved by EIA 24 VDC +10% -20%

40 VA (100 VAC), 50 VA (240 VAC) 250 mA max. Approx. 80 g

Approx. 615 g (including cable)

Weight

❚ Dimensions N-42/N-48

0.22" 5.5

ø0.18" 2 x ø4.5 mounting hole

BL-U1

READER

POWER

1.70" 43.2

SD

RD

2.17" 55

TERMINATOR ON OFF

100 to 240 VAC ø0.26" ø6.5, Cable length: 6.6' 2 m

N-48

0.23" 5.9 0.23" 5.9

1.57" Approx. 40

2.49" 63.2 3.86" 4.33" 98 110

1.02" 26

2.95" 75

3.54" 90 120°

BL-U2

ø0.18" 2 x ø4.5 mounting hole

0.22" 5.5 0.16" 4

1.97" 50

0.16" 4

3.58" 91 max.

2.17" 55

1.70" 43.2

0.23" 5.9 0.23" 5.9

ø0.18" ø4.5 5.91" mounting hole 150 7.32" 186

2.49" 63.2 2.95" 75

0.83" 21

0.22" 5.5

19

Page 20

Setup software

A Practical Setup Tool Designed for Easy Operation FREE Setup software A FREE optional easy menu-driven setup software is available with the BL-700/600/180 Series. Settings are changed by simply clicking on the desired item. No serial commands are required. The software must be ordered separately.

1 2 3 1 Operation setting screen

2 Bar code preset screen

3 Readout data monitor screen

The standard Windows® -style interface makes setting up the bar code reader’s operating parameters easier than ever.

Included with the software are preset values for 8 common types of bar codes. Detailed settings let you adjust the parameters to suit your application.

When in test mode, the BL Series performance rate (% of maximum) and reading frequency (scans per second) are clearly displayed, using built-in monitor screen.

DV-90 Setup software User-friendly DV-90 setup software The included software provides a simple and intuitive interface for users to change the settings of the DV-90 with a PC. In addition, setup parameters can be printed out in the form of setup barcodes, enabling simple, timesaving setup of the DV-90. By simply scanning the codes into the DV-90, the settings can be changed, eliminating the need for a PC.

20

DV-90 Series software control panel

Page 21

❚ Dimensions

Unit: Inch mm

■ BL-700 Series

■ BL-180 Series Front-view type

53 2.09"

Side view type 4 0.16"

0.16" 4

(A) 2x2-M3 Depth 0.20" or less 5 mm

1.12" 28.5 0.39" 10

(*)

20 0.79" 80

2.17" 55

Laser transmitter 2 x ø3.5 ø0.14" mounting hole

0.39" 9.9

ø0.39" ø10 1.14" 29

0.20" 5 0.39 10 2.28" 58

1.30" 33

2.03" 51.5 0.16" 4

1.02" 26

80

0.59" 15

1.42" 36

1.30" 33

0.39" 10

ø0.18" ø4.5 Cable length 5.9' 1.8m

0.16" 4

0.13" 3.25 0.13" 1.83" 3.25 46.5 * The laser beam radiates at 10 ±0.5° perpendicular to side (A).

1.42" 36

■BL-600 Series Front-view type 1.18" 30 1.15" 29.3

Side view type 17°

Laser beam Laser beam 0.74" 18.9

0.69" 17.6

1.22" 31 2 x M3 Depth 0.16" 4 or less 0.89" 22.5

0.14" 3.5

2x2-M3 Depth 0.20 or less 5 mm 20 0.79"

ø0.39" 37 ø10 6 1.46" Receiver axis 0.24"

5 0.20" 0.49" 12.5

ø0.18" ø4.5 Cable length 5.9' 1.8m

0.39" 10

Receiver axis

0.67" 17

1.42" 36 2.17" 55

2.17" 55

0.60" 15.3

1.04" 26.5

0.59" 15

(Readable label width)

10°

0.24" 6

(Readable label width)

ø0.23" ø5.8 Cable length 5.9' 1.8m

Laser beam

1.02" 0.67" 17 26 1.85" 47

0.52" 13.3

22 0.87"

21 0.83"

Center of laser scan

1.57" 40 0.96" 24.3

1.30" 33

0.14" 3.5

0.59" 15 Min

1.89" 48

1.50" 38.1

0.96" 24.3 2 x M3 Depth 0.16" 4 or less

0.15" 3.8 ø0.17" ø4.2 Cable length 5.9' 1.8m

0.37" 9.5

0.48" 12.2

40.7 1.60" Center of laser scan

21 0.83"

3.5 0.14"

1.89" 48

0.14" 3.5

0.59" 15 Min

0.48" 12.3

0.37" 9.5

0.15" 3.8 ø0.17" ø4.2 Cable length 5.9' 1.8 m

❚ Warning The BL-600 Series conforms to FDA and IEC standards as follows:

The BL-700 Series conforms to FDA and IEC standards as follows:

Model

BL-600/601/600HA/601HA/650HA/651HA

Model

BL-700/701/740/741/780/781

FDA

Class II

FDA

Class II

IEC

Class 2

IEC

Class 2

Protective housing labels

Protective housing labels

FDA

FDA

CAUTION

IEC LASER RADIATION WHEN OPEN. DO NOT STARE INTO BEAM.

CAUTION

CAUTION Laser radiation when open. Do not stare into beam.

Warning labels BL- 600/601/ 600HA/ 601HA

IEC LASER RADIATION WHEN OPEN. DO NOT STARE INTO BEAM.

Warning labels FDA Class II AVOID EXPOSURE LASER RADIATION IS EMITTED FROM THIS APERTURE.

CAUTION LASER RADIATIONDO NOT STARE INTO BEAM.

IEC Class 2

BL-700/701

LASER RADIATION DO NOT STARE INTO BEAM Maximum output Pulse duration Emitted wavelength

LASER RADIATION IS EMITTED FROM THIS APERTURE.

in conformity to IEC 60825-1 1998-01 SEMICONDUCTOR LASER 650 nm MAXIMUM OUTPUT 1.5 mW PULSE DURATION 56 µs CLASS II LASER PRODUCT

CAUTION - Laser radiation when open. Do not stare into beam.

BL-740/741 FDA Class II CAUTION AVOID EXPOSURE LASER RADIATION IS EMITTED FROM THIS APERTURE.

LASER RADIATIONDO NOT STARE INTO BEAM. SEMICONDUCTOR LASER 650 nm MAXIMUM OUTPUT 1.5 mW PULSE DURATION 56 µs CLASS II LASER PRODUCT

FDA Class II AVOID EXPOSURE

1.5 mW 99 µs 650 nm

CLASS 2 LASER PRODUCT CAUTION LASER RADIATION WHEN OPEN. DO NOT STARE INTO BEAM.

BL- 650HA/ 651HA

CAUTION Laser radiation when open. Do not stare into beam.

LASER RADIATION DO NOT STARE INTO BEAM

AVOID EXPOSURE

CLASS 2 LASER PRODUCT in conformity to IEC 60825-1 1998-01

1.5 mW 82 µs 650 nm

LASER RADIATION IS EMITTED FROM THIS APERTURE.

BL-780/781

AVOID EXPOSURE

LASER RADIATION DO NOT STARE INTO BEAM Maximum output Pulse duration Emitted wavelength

SEMICONDUCTOR LASER 650 nm MAXIMUM OUTPUT 1.4 mW PULSED DURATION 50 µs CLASS II LASER PRODUCT

CLASS 2 LASER PRODUCT

CAUTION LASER RADIATIONDO NOT STARE INTO BEAM SEMICONDUCTOR LASER 650 nm MAXIMUM OUTPUT 1.8 mW PULSED DURATION 50 µs CLASS II LASER PRODUCT

FDA Class II

LASER RADIATION IS EMITTED FROM THIS APERTURE.

IEC Class 2

LASER RADIATIONDO NOT STARE INTO BEAM

FDA Class II

IEC Class 2 Maximum output Pulse duration Emitted wavelength

CAUTION

CAUTION LASER RADIATIONDO NOT STARE INTO BEAM SEMICONDUCTOR LASER 650 nm MAXIMUM OUTPUT 2.0 mW PULSED DURATION 50 µs CLASS II LASER PRODUCT

1.4 mW 91 µs 650 nm in conformity to IEC825-1 11.1993

IEC Class 2 LASER RADIATION DO NOT STARE INTO BEAM Maximum output Pulse duration Emitted wavelength

1.8 mW 91 µs 650 nm

CLASS 2 LASER PRODUCT in conformity to IEC825-1 11.1993

IEC Class 2 LASER RADIATION DO NOT STARE INTO BEAM Maximum output Pulse duration Emitted wavelength

2.0 mW 91 µs 650 nm

CLASS 2 LASER PRODUCT in conformity to IEC825-1 11.1993

21

Page 22

❚ Reading range characteristics

Unit: Inch mm

■ BL-700/701

■ BL-740/741

■ BL-780/781

Readable label width 600 500 400 300 200 100 0 100 200 300 400 500 600

Readable label width 400 300 200 100 0 100 200 300 400 15.75" 11.81" 7.87" 3.94" 3.94" 7.87" 11.81" 15.75"

Readable label width 100 100 0 3.94" 3.94"

200 7.87"

200 7.87"

47.24" 1,200 43.31" 1,100 29.53" 750 25.59" 650

14.57" 370

19.29" 490 17.32" 440

22.83" 580

DC B AE

8.07" 205 7.48" 190 7.28" 185 6.89" 175 6.30" 160

9.06" 230 (Focal distance)

(Measuring conditions) • The KEYENCE standard barcode is used. • Skew: 0° • Pitch: 0° • Tilt: 0° • Ratio 1:2.5 • Including the margins

A B C D E

14.17" 360 12.99" 330

D C B A

18.90" 480

19.69" 500 (Focal distance)

15.75" 400 (Focal distance)

D C E B A

■ BL-600/601

34.25" 870

21.65" 550

12.80" 325 12.60" 320 11.81" 300 10.83" 275

Narrow bar width 0.006" 0.15 mm 0.007" 0.19 mm 0.01" 0.25 mm 0.02" 0.5 mm 1 (EAN)

39.76" 1,010 35.43" 900 27.56" 700 17.13" 435 18.31" 465 15.75" 400

23.62 600 20.08" 510 16.93" 430 13.78" 350 12.99" 330 13.70" 348 11.81" 300

12.20" 310 10.83" 275 10.63" 270 10.00" 254 8.27" 210 8.46" 215 7.28" 185

A B C D E

23.82"19.69"15.75"11.81"7.87"3.94" 3.94"7.87"11.81"15.75"19.69"23.82"

9.06" 230 5.91" 150

(Measuring conditions) • The KEYENCE standard barcode is used. • Skew: 0° • Pitch: 0° • Tilt: 0° • Ratio 1:2.5 • Including the margins

Narrow bar width 0.01" 0.25 mm 0.01" 0.32 mm 0.02" 0.5 mm 0.04" 1 mm 1 (EAN)

A B C D

12.60" 320 7.87" 200

(Measuring conditions) • The KEYENCE standard barcode is used. • Skew: 0° • Pitch: 0° • Tilt: 0° • Ratio 1:2.5 • Including the margins

Narrow bar width 0.01" 0.32 mm 0.02" 0.5 mm 0.04" 1.0 mm 0.08" 2.0 mm

Readable label width

100 3.94"

100 3.94"

0

9.84" 250 4.33" 110

■ BL-600HA/601HA

12.99"330

100 3.94"

11.42"290

6.70" 170 3.78" 96

5.91" 150 5.51" 140

Narrow bar width 0.049" 0.125 mm 0.007" 0.19 mm 0.010" 0.25 mm 0.02" 0.5 mm

(Measuring conditions) • The KEYENCE standard barcode is used. • Skew: 15° • Pitch: 0° • Tilt: 0° • Ratio 1:2.5 • Including the margins

B

STABILITY

10 0.39" 1.30" 33 5 0.20"

Readable label width

OK/NG

0.39" 10 Reading distance 0.20" 5

A B

Narrow bar width Less than 0.007" 0.19 0.007" 0.19 Min.

(Measuring conditions) • The KEYENCE standard barcode is used. • Skew: -10° • Pitch: 0° • Tilt: 0°

3.35" 85

2.76" 70 2.36" 60 2.17" 55

A

2.36" 3.15" 60 80

22

A B C D

5.51" 140 4.92" 125

DC B A

A B C D

2.56" 65 (Focal distance)

(Measuring conditions) • The KEYENCE standard barcode is used. • Skew: 15° • Pitch: 0° • Tilt: 0° • Ratio 1:2.5 • Including the margins

■ BL-180/185

BL-180

DC BA

3.54" 90 (Focal distance)

3.54" 90 2.95" 75

6.89" 175

Narrow bar width 0.0049" 0.125 mm 0.007" 0.19 mm 0.010" 0.25 mm 0.02" 0.5 mm

1.77" 45

(Measuring conditions) • The KEYENCE standard barcode is used. • Skew: 0° • Pitch: 0° • Til: 0° • Ratio 1:2.5 • Including the margins

Reading distance

7.48" 190

4.13" 105

4.72" 120 (Focal distance)

Narrow bar width 0.007" 0.19 mm 0.010" 0.25 mm 0.02" 0.5 mm 0.04" 1.0 mm

100 3.94"

3.39" 86

DC B A

A B C D

Readable label width 0

Reading distance

6.30" 160

100 3.94"

100 3.94"

6.14" 156

Reading distance

7.87" 200

■ BL-650HA/651HA

Readable label width 0

Page 23

❚ Barcode samples

NB= Narrow bar width WB= Wide bar width * The bar codes given below do not show the bar code reader performance criteria.

CODE39 NB=0.25mm,NB:WB=1:3.0

NB=0.5mm,NB:WB=1:2.5

NB=1.0mm,NB:WB=1:2.2

CODABAR NB=0.25mm,NB:WB=1:2.5

NB=0.38mm,NB:WB=1:2.67

NB=0.5mm,NB:WB=1:2.25

UPC-A

UPC-E

EAN

UPC/EAN

CODE128 NB=0.25mm

NB=0.25mm

ITF NB=0.25mm,NB:WB=1:3.0

NB=0.5mm,NB:WB=1:2.2

NB=1.0mm,NB:WB=1:2.5

23

Page 24

For More Information Visit

CALL TOLL FREE www.keyence.com/BL

TO CONTACT YOUR LOCAL OFFICE

Fax : 201-930-0099

1 - 8 8 8 - 5 3 9 - 3 6 2 3

KEYENCE CORPORATION OF AMERICA Corporate Office

50 Tice Blvd., Woodcliff Lake, NJ 07677

■ Regional offices

Arizona Phoenix California N.California Los Angeles Florida Tampa

Phone:201-930-0100 Fax:201-930-0099 E-mail:keyence@keyence.com

Atlanta Georgia Chicago Illinois Indianapolis Indiana Massachusetts Boston

New Jersey New Jersey Detroit Grand Rapids North Carolina Charlotte Minnesota Minneapolis Ohio Cincinnati Missouri St. Louis Cleveland Michigan

Portland Oregon Pennsylvania Philadelphia Tennessee Nashville Texas Dallas

Richmond Virginia Washington Seattle

KEYENCE CANADA INC. 1450 Meyerside Drive, #301, Mississauga, Ontario L5T 2N5 CANADA

Phone:905-696-9970 Fax:905-696-8340

E-mail:keyence@keyence.com

©KEYENCE CORPORATION,2005 BLG05-KA-C-E-0220 0025-1 Printed in Japan