Page 17
Multiple Scanning Heads Multi-head mode
Mutual interference prevention function
The N-400 controls several bar code readers as if they were a single unit, without using a host computer. This mode is useful when several bar code readers are used simultaneously to read bar code labels pasted on various positions.
The N-400 controls several bar code readers so that they scan alternatively, eliminating mutual interference. This function is useful when several bar code readers must be installed close to each other to read a label with several bar codes.
Special power supply unit N-48 BL-U1
Special power supply unit N-48 BL-U1 RS-485
Host computer N-400 TEST
N-400
RS-232C
SD
RD
POWER TIMING
RS-232C
TERMINATOR ON
RS
CS
SD RD RS-485
RS-232C
BL-700/ BL-600/ BL-180
Host computer N-400 TEST
N-400
RS-232C
SD
RD
POWER TIMING
RS-232C
TERMINATOR
OFF
RS
CS
SD RD RS-485
RS-232C
ON OFF
Sensor for synchronization
Sensor for synchronization
BL-700/BL-600/ BL-180
Features of the N-400 Greatly reduced programming for the host computer
Setting change of bar code readers
Up to 31 bar code readers can be controlled with a single host computer.
You can change various settings of bar code readers using the N-400, such as adding bar code types or changing the maximum code length to be read.
24 KB memory (sending buffer) featured as standard The internal buffer can store up to approximately 3500 pieces of five-digit data. In the event of an accident the data is retained even when the host computer is turned off.
Reading test of each bar code reader You can use the handy functions of the BL Series, as well as the test mode, through the N-400. This allows remote access to the bar code readers to check settings and ensure correct operation.
Built-in test mode for connection check The N-400 features a test mode to enable an easy check of the connection with the bar code readers. No special programming or PC is required.
❚ Specifications Model N-400 BL-700 Series, BL-600 Series, BL-180 Series Connectable bar code reader 15 to 26 VDC, 10 mA max. Rated input Trigger input 1.0 mA Max. OFF current RS-232C Applied standards Start-stop (Full-duplex) Synchronization ASCII Transmission code 600/1,200/2,400/4,800/9,600/19,200/31,250/38,400 bps RS-232C Baud rate 7/8 bits Data length Even/Odd/None Parity check 1 bit/2 bits Stop bit length RS-485 Applied standards Start-stop (Full-duplex) Synchronization ASCII Transmission code 600/1,200/2,400/4,800/9,600/19,200/31,250/38,400 bps Baud rate 7/8 bits Data length RS-485 Even/Odd/None Parity check 1 bit/2 bits Stop bit length 31 Max. number of connectable units 1.2 km Max. total extension distance Environ0 to +50°C (32 to 122°F), No condensation Ambient temperature mental 35 to 85%, No condensation resistance Relative humidity 24 VDC +10% Power supply voltage Power -20% rating 140 mA max. Current consumption Weight Approx. 180 g
❚ Dimensions
1.07" 27.3 RS-232C
4.41" 3.94" 3.54" 112 100 90
SD
RD
RS
CS
1.39" 35.4
POWER TIMING SD RD RS-485 RS-232C
TERMINATOR ON OFF
1.57"40 2.36"60
ø0.20 4 x ø5 mounting hole
2.01" 51
17
Page 18
BL-80 Series
CCD HANDHELD BAR CODE READER
3.23" (82 mm)
Safe for the eyes
Directly connects to a PC
Uses LED’s, not a laser as the light source. This eliminates possible danger to the user’s eyes, preventing accidents from happening.
Transmitting bar code data is as easy as connecting the reader to a PC. There is no need for software.
Low price
Simple set up with data menu
This super-high-quality low-priced product is made possible through a streamlined manufacturing system integrating all processes from development to production.
Set-up is easily achieved by simply scanning the bar code menu located in the manual.
Superb reading ability. The BL-80 Series can reliably read bars as narrow as 0.005" (0.125 mm).
❚ Specifications Model Interface Connector type Light source Reading distance Readable bar width CODE39, ITF, IATA, Industrial 2 of 5, Codabar Resolution EAN/UPC CODE93, CODE128, EAN-128 Scanning rate Target codes Ambient temperature Relative humidity Power supply voltage Current consumption Weight Cable length
BL-80VE PS/2 Keyboard Interface External PS/2 keyboard Mini-DIN 6-pin or DIN 5-pin
BL-80RKE RS-232C
RS-232C general purpose
For Keyence products
D-sub 9-pin (Female) Red LED 0" to 0.71" 0 to 18 mm 3.23" 82 mm (included quiet zone)
0.006" 0.15 mm
0.005" 0.125 mm
0.01" 0.25 mm (0.8 times) 0.006" 0.15 mm 100 scans/second EAN/UPC (A•E), CODE39, Codabar, ITF, Industrial2-of-5, IATA, CODE93, CODE128, EAN-128 0 to +40°C (32 to 104°F), No condensation 35 to 85%, No condensation 5 VDC ±5% 5 VDC ±5% 1. Less than 95 mA Less than 175 mA Approx. 140 g (without cable) 6.6' 2.0 m 5.3' 1.6 m (coiled) 0.007" 0.17 mm
1. AC adapter is included with BL-80RE. The power supply voltage for the AC adapter is 120 VAC (60 Hz, 7 W)
18
BL-80RE
Page 19
Peripheral devices Power supply units
N-42
N-48
BL-U1
BL-U2
❚ Specifications Model Conversion interface Connectable bar code reader Power supply for bar code reader Input rating Trigger input Max. OFF current
N-42 N-48 RS-232C RS-485 (Level conversion) RS-422A (Level conversion) BL-700 Series, BL-600 Series, BL-180 Series 5 VDC ±5% (630 mA) 15 to 26 VDC, 10 mA max. 1.0 mA RS-485(Max. number of connectable units: 31) RS-422A (Max. total extension distance: 1.2 km ) (Max. total extension distance: 1.2 km) RS-232C
Interface Power rating
24 VDC +10% -20% 260 mA max. Approx. 100 g
Power supply voltage Current consumption
Weight Model Connectable bar code reader Power supply for bar code reader Power supply for sensor Trigger Input rating input Max. OFF current
BL-U2 BL-700 Series, BL-600 Series, BL-180 Series
5 VDC ±5% (1.5 A) 12 V ±10% (300 mA) 8.5 to 30 VDC, 10 mA max. 0.5 mA
5 VDC ±5% (630 mA) 8.5 to 26 VDC, 10 mA max. 1.0 mA
RS-232C, RS-422A, RS-485 multi-drop (Max. number of connectable units: 31) (Max. total extension distance: 1.2 km) 100 to 240 VAC (50/60 Hz)
Interface Power rating
BL-U1
Power supply voltage Power consumption Current consumption
Conforms to RS-232C approved by EIA 24 VDC +10% -20%
40 VA (100 VAC), 50 VA (240 VAC) 250 mA max. Approx. 80 g
Approx. 615 g (including cable)
Weight
❚ Dimensions N-42/N-48
0.22" 5.5
ø0.18" 2 x ø4.5 mounting hole
BL-U1
READER
POWER
1.70" 43.2
SD
RD
2.17" 55
TERMINATOR ON OFF
100 to 240 VAC ø0.26" ø6.5, Cable length: 6.6' 2 m
N-48
0.23" 5.9 0.23" 5.9
1.57" Approx. 40
2.49" 63.2 3.86" 4.33" 98 110
1.02" 26
2.95" 75
3.54" 90 120°
BL-U2
ø0.18" 2 x ø4.5 mounting hole
0.22" 5.5 0.16" 4
1.97" 50
0.16" 4
3.58" 91 max.
2.17" 55
1.70" 43.2
0.23" 5.9 0.23" 5.9
ø0.18" ø4.5 5.91" mounting hole 150 7.32" 186
2.49" 63.2 2.95" 75
0.83" 21
0.22" 5.5
19
Page 20
Setup software
A Practical Setup Tool Designed for Easy Operation FREE Setup software A FREE optional easy menu-driven setup software is available with the BL-700/600/180 Series. Settings are changed by simply clicking on the desired item. No serial commands are required. The software must be ordered separately.
1 2 3 1 Operation setting screen
2 Bar code preset screen
3 Readout data monitor screen
The standard Windows® -style interface makes setting up the bar code reader’s operating parameters easier than ever.
Included with the software are preset values for 8 common types of bar codes. Detailed settings let you adjust the parameters to suit your application.
When in test mode, the BL Series performance rate (% of maximum) and reading frequency (scans per second) are clearly displayed, using built-in monitor screen.
DV-90 Setup software User-friendly DV-90 setup software The included software provides a simple and intuitive interface for users to change the settings of the DV-90 with a PC. In addition, setup parameters can be printed out in the form of setup barcodes, enabling simple, timesaving setup of the DV-90. By simply scanning the codes into the DV-90, the settings can be changed, eliminating the need for a PC.
20
DV-90 Series software control panel
Page 21
❚ Dimensions
Unit: Inch mm
■ BL-700 Series
■ BL-180 Series Front-view type
53 2.09"
Side view type 4 0.16"
0.16" 4
(A) 2x2-M3 Depth 0.20" or less 5 mm
1.12" 28.5 0.39" 10
(*)
20 0.79" 80
2.17" 55
Laser transmitter 2 x ø3.5 ø0.14" mounting hole
0.39" 9.9
ø0.39" ø10 1.14" 29
0.20" 5 0.39 10 2.28" 58
1.30" 33
2.03" 51.5 0.16" 4
1.02" 26
80
0.59" 15
1.42" 36
1.30" 33
0.39" 10
ø0.18" ø4.5 Cable length 5.9' 1.8m
0.16" 4
0.13" 3.25 0.13" 1.83" 3.25 46.5 * The laser beam radiates at 10 ±0.5° perpendicular to side (A).
1.42" 36
■BL-600 Series Front-view type 1.18" 30 1.15" 29.3
Side view type 17°
Laser beam Laser beam 0.74" 18.9
0.69" 17.6
1.22" 31 2 x M3 Depth 0.16" 4 or less 0.89" 22.5
0.14" 3.5
2x2-M3 Depth 0.20 or less 5 mm 20 0.79"
ø0.39" 37 ø10 6 1.46" Receiver axis 0.24"
5 0.20" 0.49" 12.5
ø0.18" ø4.5 Cable length 5.9' 1.8m
0.39" 10
Receiver axis
0.67" 17
1.42" 36 2.17" 55
2.17" 55
0.60" 15.3
1.04" 26.5
0.59" 15
(Readable label width)
10°
0.24" 6
(Readable label width)
ø0.23" ø5.8 Cable length 5.9' 1.8m
Laser beam
1.02" 0.67" 17 26 1.85" 47
0.52" 13.3
22 0.87"
21 0.83"
Center of laser scan
1.57" 40 0.96" 24.3
1.30" 33
0.14" 3.5
0.59" 15 Min
1.89" 48
1.50" 38.1
0.96" 24.3 2 x M3 Depth 0.16" 4 or less
0.15" 3.8 ø0.17" ø4.2 Cable length 5.9' 1.8m
0.37" 9.5
0.48" 12.2
40.7 1.60" Center of laser scan
21 0.83"
3.5 0.14"
1.89" 48
0.14" 3.5
0.59" 15 Min
0.48" 12.3
0.37" 9.5
0.15" 3.8 ø0.17" ø4.2 Cable length 5.9' 1.8 m
❚ Warning The BL-600 Series conforms to FDA and IEC standards as follows:
The BL-700 Series conforms to FDA and IEC standards as follows:
Model
BL-600/601/600HA/601HA/650HA/651HA
Model
BL-700/701/740/741/780/781
FDA
Class II
FDA
Class II
IEC
Class 2
IEC
Class 2
Protective housing labels
Protective housing labels
FDA
FDA
CAUTION
IEC LASER RADIATION WHEN OPEN. DO NOT STARE INTO BEAM.
CAUTION
CAUTION Laser radiation when open. Do not stare into beam.
Warning labels BL- 600/601/ 600HA/ 601HA
IEC LASER RADIATION WHEN OPEN. DO NOT STARE INTO BEAM.
Warning labels FDA Class II AVOID EXPOSURE LASER RADIATION IS EMITTED FROM THIS APERTURE.
CAUTION LASER RADIATIONDO NOT STARE INTO BEAM.
IEC Class 2
BL-700/701
LASER RADIATION DO NOT STARE INTO BEAM Maximum output Pulse duration Emitted wavelength
LASER RADIATION IS EMITTED FROM THIS APERTURE.
in conformity to IEC 60825-1 1998-01 SEMICONDUCTOR LASER 650 nm MAXIMUM OUTPUT 1.5 mW PULSE DURATION 56 µs CLASS II LASER PRODUCT
CAUTION - Laser radiation when open. Do not stare into beam.
BL-740/741 FDA Class II CAUTION AVOID EXPOSURE LASER RADIATION IS EMITTED FROM THIS APERTURE.
LASER RADIATIONDO NOT STARE INTO BEAM. SEMICONDUCTOR LASER 650 nm MAXIMUM OUTPUT 1.5 mW PULSE DURATION 56 µs CLASS II LASER PRODUCT
FDA Class II AVOID EXPOSURE
1.5 mW 99 µs 650 nm
CLASS 2 LASER PRODUCT CAUTION LASER RADIATION WHEN OPEN. DO NOT STARE INTO BEAM.
BL- 650HA/ 651HA
CAUTION Laser radiation when open. Do not stare into beam.
LASER RADIATION DO NOT STARE INTO BEAM
AVOID EXPOSURE
CLASS 2 LASER PRODUCT in conformity to IEC 60825-1 1998-01
1.5 mW 82 µs 650 nm
LASER RADIATION IS EMITTED FROM THIS APERTURE.
BL-780/781
AVOID EXPOSURE
LASER RADIATION DO NOT STARE INTO BEAM Maximum output Pulse duration Emitted wavelength
SEMICONDUCTOR LASER 650 nm MAXIMUM OUTPUT 1.4 mW PULSED DURATION 50 µs CLASS II LASER PRODUCT
CLASS 2 LASER PRODUCT
CAUTION LASER RADIATIONDO NOT STARE INTO BEAM SEMICONDUCTOR LASER 650 nm MAXIMUM OUTPUT 1.8 mW PULSED DURATION 50 µs CLASS II LASER PRODUCT
FDA Class II
LASER RADIATION IS EMITTED FROM THIS APERTURE.
IEC Class 2
LASER RADIATIONDO NOT STARE INTO BEAM
FDA Class II
IEC Class 2 Maximum output Pulse duration Emitted wavelength
CAUTION
CAUTION LASER RADIATIONDO NOT STARE INTO BEAM SEMICONDUCTOR LASER 650 nm MAXIMUM OUTPUT 2.0 mW PULSED DURATION 50 µs CLASS II LASER PRODUCT
1.4 mW 91 µs 650 nm in conformity to IEC825-1 11.1993
IEC Class 2 LASER RADIATION DO NOT STARE INTO BEAM Maximum output Pulse duration Emitted wavelength
1.8 mW 91 µs 650 nm
CLASS 2 LASER PRODUCT in conformity to IEC825-1 11.1993
IEC Class 2 LASER RADIATION DO NOT STARE INTO BEAM Maximum output Pulse duration Emitted wavelength
2.0 mW 91 µs 650 nm
CLASS 2 LASER PRODUCT in conformity to IEC825-1 11.1993
21
Page 22
❚ Reading range characteristics
Unit: Inch mm
■ BL-700/701
■ BL-740/741
■ BL-780/781
Readable label width 600 500 400 300 200 100 0 100 200 300 400 500 600
Readable label width 400 300 200 100 0 100 200 300 400 15.75" 11.81" 7.87" 3.94" 3.94" 7.87" 11.81" 15.75"
Readable label width 100 100 0 3.94" 3.94"
200 7.87"
200 7.87"
47.24" 1,200 43.31" 1,100 29.53" 750 25.59" 650
14.57" 370
19.29" 490 17.32" 440
22.83" 580
DC B AE
8.07" 205 7.48" 190 7.28" 185 6.89" 175 6.30" 160
9.06" 230 (Focal distance)
(Measuring conditions) • The KEYENCE standard barcode is used. • Skew: 0° • Pitch: 0° • Tilt: 0° • Ratio 1:2.5 • Including the margins
A B C D E
14.17" 360 12.99" 330
D C B A
18.90" 480
19.69" 500 (Focal distance)
15.75" 400 (Focal distance)
D C E B A
■ BL-600/601
34.25" 870
21.65" 550
12.80" 325 12.60" 320 11.81" 300 10.83" 275
Narrow bar width 0.006" 0.15 mm 0.007" 0.19 mm 0.01" 0.25 mm 0.02" 0.5 mm 1 (EAN)
39.76" 1,010 35.43" 900 27.56" 700 17.13" 435 18.31" 465 15.75" 400
23.62 600 20.08" 510 16.93" 430 13.78" 350 12.99" 330 13.70" 348 11.81" 300
12.20" 310 10.83" 275 10.63" 270 10.00" 254 8.27" 210 8.46" 215 7.28" 185
A B C D E
23.82"19.69"15.75"11.81"7.87"3.94" 3.94"7.87"11.81"15.75"19.69"23.82"
9.06" 230 5.91" 150
(Measuring conditions) • The KEYENCE standard barcode is used. • Skew: 0° • Pitch: 0° • Tilt: 0° • Ratio 1:2.5 • Including the margins
Narrow bar width 0.01" 0.25 mm 0.01" 0.32 mm 0.02" 0.5 mm 0.04" 1 mm 1 (EAN)
A B C D
12.60" 320 7.87" 200
(Measuring conditions) • The KEYENCE standard barcode is used. • Skew: 0° • Pitch: 0° • Tilt: 0° • Ratio 1:2.5 • Including the margins
Narrow bar width 0.01" 0.32 mm 0.02" 0.5 mm 0.04" 1.0 mm 0.08" 2.0 mm
Readable label width
100 3.94"
100 3.94"
0
9.84" 250 4.33" 110
■ BL-600HA/601HA
12.99"330
100 3.94"
11.42"290
6.70" 170 3.78" 96
5.91" 150 5.51" 140
Narrow bar width 0.049" 0.125 mm 0.007" 0.19 mm 0.010" 0.25 mm 0.02" 0.5 mm
(Measuring conditions) • The KEYENCE standard barcode is used. • Skew: 15° • Pitch: 0° • Tilt: 0° • Ratio 1:2.5 • Including the margins
B
STABILITY
10 0.39" 1.30" 33 5 0.20"
Readable label width
OK/NG
0.39" 10 Reading distance 0.20" 5
A B
Narrow bar width Less than 0.007" 0.19 0.007" 0.19 Min.
(Measuring conditions) • The KEYENCE standard barcode is used. • Skew: -10° • Pitch: 0° • Tilt: 0°
3.35" 85
2.76" 70 2.36" 60 2.17" 55
A
2.36" 3.15" 60 80
22
A B C D
5.51" 140 4.92" 125
DC B A
A B C D
2.56" 65 (Focal distance)
(Measuring conditions) • The KEYENCE standard barcode is used. • Skew: 15° • Pitch: 0° • Tilt: 0° • Ratio 1:2.5 • Including the margins
■ BL-180/185
BL-180
DC BA
3.54" 90 (Focal distance)
3.54" 90 2.95" 75
6.89" 175
Narrow bar width 0.0049" 0.125 mm 0.007" 0.19 mm 0.010" 0.25 mm 0.02" 0.5 mm
1.77" 45
(Measuring conditions) • The KEYENCE standard barcode is used. • Skew: 0° • Pitch: 0° • Til: 0° • Ratio 1:2.5 • Including the margins
Reading distance
7.48" 190
4.13" 105
4.72" 120 (Focal distance)
Narrow bar width 0.007" 0.19 mm 0.010" 0.25 mm 0.02" 0.5 mm 0.04" 1.0 mm
100 3.94"
3.39" 86
DC B A
A B C D
Readable label width 0
Reading distance
6.30" 160
100 3.94"
100 3.94"
6.14" 156
Reading distance
7.87" 200
■ BL-650HA/651HA
Readable label width 0
Page 23
❚ Barcode samples
NB= Narrow bar width WB= Wide bar width * The bar codes given below do not show the bar code reader performance criteria.
CODE39 NB=0.25mm,NB:WB=1:3.0
NB=0.5mm,NB:WB=1:2.5
NB=1.0mm,NB:WB=1:2.2
CODABAR NB=0.25mm,NB:WB=1:2.5
NB=0.38mm,NB:WB=1:2.67
NB=0.5mm,NB:WB=1:2.25
UPC-A
UPC-E
EAN
UPC/EAN
CODE128 NB=0.25mm
NB=0.25mm
ITF NB=0.25mm,NB:WB=1:3.0
NB=0.5mm,NB:WB=1:2.2
NB=1.0mm,NB:WB=1:2.5
23
Page 24
For More Information Visit
CALL TOLL FREE www.keyence.com/BL
TO CONTACT YOUR LOCAL OFFICE
Fax : 201-930-0099
1 - 8 8 8 - 5 3 9 - 3 6 2 3
KEYENCE CORPORATION OF AMERICA Corporate Office
50 Tice Blvd., Woodcliff Lake, NJ 07677
■ Regional offices
Arizona Phoenix California N.California Los Angeles Florida Tampa
Phone:201-930-0100 Fax:201-930-0099 E-mail:keyence@keyence.com
Atlanta Georgia Chicago Illinois Indianapolis Indiana Massachusetts Boston
New Jersey New Jersey Detroit Grand Rapids North Carolina Charlotte Minnesota Minneapolis Ohio Cincinnati Missouri St. Louis Cleveland Michigan
Portland Oregon Pennsylvania Philadelphia Tennessee Nashville Texas Dallas
Richmond Virginia Washington Seattle
KEYENCE CANADA INC. 1450 Meyerside Drive, #301, Mississauga, Ontario L5T 2N5 CANADA
Phone:905-696-9970 Fax:905-696-8340
E-mail:keyence@keyence.com
©KEYENCE CORPORATION,2005 BLG05-KA-C-E-0220 0025-1 Printed in Japan