Page 21

Chapter 2

Installation Procedure

Connecting trigger input To use multi-head scan mode, connect the trigger input to the N-400 only, instead of to each BL series unit. TIM COM SG

Internal circuit

TIM

+ Contact or solid state

+

+

2

COM

+

15 to 26 VDC

2.2.2 Connecting RS-232C Pin assignment

13

1

25

14

Pin No.

CAUTION

D-sub 25-pin (male) DCE specification (defined as terminal) M2.6 screw

Symbol

Function

1

FG

Frame ground

Signal direction

2

SD (TXD)

Sends data.

Input

3

RD (RXD)

Receives data.

Output

4

RS (RTS)

Ready to send data.

Input

5

CS (CTS)

Request to send data.

Output

6

DR (DSR)

Connected to pin No. 20 inside.

Output

7

SG

Signal ground

20

ER (DTR)

Connected to pin No. 6 inside.

Input

25

+5 V

5 V power supply output (100 mA)

Output, - Pin No. 25 is used for a 5 V power supply output. Do not connect this terminal to the ground terminal or any other terminal when it is unused. Doing this may damage the N-400 or the external device connected to this terminal.

RS-232C cable connections ■ Connecting personal computer • Connecting the computer with 25-pin Computer

PC

N-400

FG

1

1

FG

Connector case

1

FG

SD

2

2

SD

RD

2

2

SD

RD

3

3

RD

SD

3

3

RD

RS

4

4

SG

ER

4

4

RS

CS

5

5

RS

SG

5

5

CS

DR

6

6

CS

DR

6

6

DR

SG

7

7

DR

RS CS

7

7

SG

8

8

CD

1

20 ER

ER 20 D-sub 25-pin (male) M2.6 screw

20 ER D-sub 25-pin (male) M2.6 screw

* The OP-98769 cable (1.5 m: manufactured by KEYENCE) can be used.

Tips

• Connecting IBM PC

N-400

D-sub 9-pin (female) #4-40 screw

D-sub 25-pin (male) M2.6 screw

* The OP-98769 cable (1.5 m: manu factured by KEYENCE) and the OP25057 conversion connector can be used.

A commercially-available straight cable (D-sub 25 pin - 25 pin, or D-sub 25 pin - 9 pin) can be used.

13

Page 22

Chapter 2

Installation Procedure ■ Connecting KV series/Handheld programmer port Use the optional cable manufactured by KEYENCE.

N-400 TEST

RS-232C

SD

RD

POWER TIMING

CS SD

RS RD RS-455

TERMINATOR ON OFF

OP-24045 (1 m) or OP-24025 (5 m)

KV-10, 16, 24 KV-40, 80

OP-96369

2 1. KV-300 and KV-L2 are not available in Europe.

KV-300 1.

■ Connecting KV-L2 1. Port 1

Terminal block

KV-L2

N-400

KV-L2

N-400

FG

1

1

FG

SD

3

1

FG

SD

2

2

SD

RD

5

2

SD

RD

3

3

RD

3

RD

RS

4

4

SG

4

RS

CS

5

5

RS

5

CS

DR

6

6

CS

6

DS

SG

7

7

DR

20 ER 7 SG

ER 20 D-sub 25-pin (male) M2.6 screw

20 ER D-sub 25-pin (male) M2.6 screw

* The OP-98769 cable (1.5 m: manufactured by KEYENCE) or a commercially-available straight cable can be used.

SG

1

Terminal block

D-sub 25-pin (male) M2.6 screw

1. KV-300 and KV-L2 are not available in Europe.

■ Connecting MELSEC-A series Connection with AJ71C24, AL71C24-S*, A0J2-C214S1, AJ71UC24

Link unit

Link unit

N-400

N-400

FG

1

1

FG

Connector case

1

FG

SD

2

2

SD

RD

2

2

SD

RD

3

3

RD

SD

3

3

RD

RS

4

4

RS

ER

4

4

RS

CS

5

5

CS

SG

5

5

CS

DR

6

6

DR

DR

6

6

DR

SG

7

7

SG

RS CS

7

7

SG

8

8

CD

1

20 ER

CD 8 ER 20 D-sub 25-pin (male) M2.6 screw

14

Connection with A1SJ71C24-R2/PRF, A2CCPUC24, A2CCPUC24-PRF, A1SJ71UC24-R2/PRF

8 20 ER D-sub 25-pin (male) M2.6 screw

D-sub 25-pin (male) M2.6 screw

D-sub 25-pin (male) M2.6 screw

Page 23

Chapter 2 ■ SYSMAC-C series Connection with C-200H-LK201(-V1), C-500-LK203, C-500-LK201-V1, C120LK201-V1

Installation Procedure

Connection with C-20H, C-28H, C-40H, C-60H, C-80H

PLC

N-400

FG

1

1

FG

FG

1

1

FG

SD

2

2

SD

SD

2

2

SD

RD

3

3

RD

RD

3

3

RD

RS

4

4

RS

RS

4

4

RS

CS

5

5

CS

CS

5

5

CS

SG

7

7

SG

SG

7

7

SG

Link unit

D-sub 25-pin (male) M2.6 screw

N-400

D-sub 25-pin (male) M2.6 screw

D-sub 25-pin (male) M2.6 screw

2

D-sub 25-pin (male) M2.6 screw

* The OP-98769 cable (1.5 m: manufactured by KEYENCE) or a commercially-available straight cable can be used.

Connection with C-200HS(CPU21/23/31/ 33), CQM1(CPU21/41/42/43/44), C200HE(CPU42), C200HG(CPU43/63), C200HX(CPU44/64), C200HWCOM02/ COM04/COM05/COM06 PLC

N-400

FG

1

1

FG

SD

2

2

SD

RD

3

3

RD

RS

4

4

RS

CS

5

5

CS

SG

9

7

SG

D-sub 25-pin (male) M2.6 screw

D-sub 25-pin (male) M2.6 screw

■ SYSMAC-CV series Connection with CV500-LK201(Port 1)

Link unit FG

1

Connection with CV500LK201(Port 2), CV500, CV1000, CVM1 PLC

N-400

FG

FG

1

1

FG

2

2

SD

N-400 1

SD

2

2

SD

SD

RD

3

3

RD

RD

3

3

RD

RS

4

4

RS

RS

4

4

RS

CS

5

5

CS

CS

5

5

CS

SG

7

7

SG

SG

9

7

SG

D-sub 25-pin (male) M2.6 screw

D-sub 25-pin (male) M2.6 screw

D-sub 25-pin (male) M2.6 screw

D-sub 25-pin (male) M2.6 screw

* The OP-98769 cable (1.5 m: manufactured by KEYENCE) or a commercially-available straight cable can be used.

15

Page 24

Chapter 2

2.3

Installation Procedure

Connecting N-48 and Wiring

2.3.1 Connecting the BL series Connect the BL series to the READER port of the N-48.

BL series

N-48

2

READER

POWER

SD

RD

Pin assignment 1

2

3

4

5

D-sub 9-pin (male) DCE specification (defined as terminal) #4-40 screw 6

Pin No.

7

Symbol

8

9

Function

Signal direction

1

TIM

Trigger input

Output

2

RD (RXD)

Receives data.

Output

3

SD (TXD)

Sends data.

Input

4

OK

OK

Input

5

GND (SG)

Ground (Common ground for respective signal), 6

NG

NG

Input

7

RS (RTS)

Ready to send data.

Input

8

CS (CTS)

Request to send data.

Output

9

+5 V

5 V power supply output (600mA)

Output

2.3.2 Terminals of I/O terminal block and connections TIM COM OK NG COM

* Viewed from the left of the unit

16

Symbol

Description

Signal direction

TIM

Trigger input

Input

COM

Common terminal for trigger input

Input

OK

OK output

Output

NG

NG output

Output

COM

Common terminal for output

Output

Page 25

Chapter 2

RS-485 SG

+

-

24V DC OUT

Installation Procedure

RS-485

24V DC IN – +

-

+

SG

* Viewed from the bottom of the unit

Symbol

Description

Signal direction

RS-485 SG

RS-485 signal ground

–––

RS-485 +

RS-485 + terminal

Input/Output

RS-485 -

RS-485 - terminal

Input/Output

24 VDC IN (OUT)

24 VDC power supply input (output) + terminal

Input(Output)

24 VDC power supply input (output) - terminal

Input(Output)

2

• The following I-type clips can be used for connections.

2.0 mm max.

5 mm max.

6 mm min

Connecting power supply Connect a 24 VDC power supply to the “IN” terminal. When a 24 VDC power supply is connected to the “IN” terminal, the “OUT” terminal can be used as a 24 VDC power supply output terminal. In this case, the “OUT” terminal can be used as a power supply for other N-48 unit connected in the multidrop link configuration. (➮ For a connection example, see p. 19.)

-

24V DC OUT

24V DC IN – +

-

24 VDC +

CAUTION

•

Do not connect a power supply other than 24 VDC or the unit may be damaged.

•

Connecting a power supply to the RS-485 terminal may damage the N-48.

•

Do not connect different types of power supplies to the IN and OUT terminals or the unit may not start normally due to the potential difference between the power supplies.

17

Page 26

Chapter 2

Installation Procedure

Connecting trigger input The trigger input allows the BL series to start reading bar codes (turn on the laser beam). To connect the BL series in multi-head mode, send the trigger input to the N-400 instead of the N-48.

TIM COM OK TIM

Internal circuit

2 +

+

+

COM

+ 15 to 26 VDC

Connecting OK/NG output

OK NG COM

+

Internal circuit

The OK/NG output indicates the result of the comparison with preset data, or indicates whether reading is successful or not.

Load

Load Load *Rated load: 30 V max. (100mA)

18

+

Page 27

Chapter 2

Installation Procedure

2.3.3 Connecting RS-485 For the RS-485 connections, use the “RS-485 +” and “RS-485 -” terminals provided on the terminal block.

* TIM COM RS-485 SG RS-485 + RS-485 – 24V DC OUT + 24V DC OUT – 24V DC IN + 24V DC IN –

Shield cable Twisted pair cable RS-485 SG RS-485 + RS-485 – 24V DC IN + 24V DC IN –

2

N-400

24V DC OUT – 24V DC OUT + RS-485 + RS-485 – RS-485 SG

+ 24 VDC

N-48

RS-485 SG RS-485 + RS-485 – 24V DC IN + 24V DC IN – 24V DC OUT – 24V DC OUT + RS-485 + RS-485 – RS-485 SG

N-48

RS-485 SG RS-485 + RS-485 – 24V DC IN + 24V DC IN – 24V DC OUT – 24V DC OUT + RS-485 + RS-485 – RS-485 SG

* N-48

19

Page 28

Chapter 2

Installation Procedure •

The diagram on the previous page shows the connections to supply 24 VDC power to the N-48 from the power supply connected to the N-400. In this case, the 24 VDC power supply connected to the N-400 must have a capacity of at least “140 mA (N-400 current consumption) + 260 mA (N-48 current consumption) x n (Number of N48 units connected)”.

Example When five N-48 units are connected: 140 mA + 260 mA x 5 = 1.44 A Use a power supply with at least 1.44 A capacity.

2

Note: The RS-485 cable can be extended up to 1.2 km. With the power supply cable, however, the 1.2 km extension is not guaranteed. To extend the power supply cable as shown in the connection diagram on the previous page, ensure that the power voltage supplied to all the N-48 units is within the range of 24 VDC -20% to +10%. •

To connect a 24 VDC power supply to each N-48 unit, remove the 24 VDC wiring shown in the previous page. To connect the power supply, use the following cable. Recommended RS-485 cable • 0.75 mm2 x 2 cores, sheilded

•

Up to thirty-one N-48 (BL series) units can be connected in multi-drop link mode.

•

The total extension length of the RS-485 cable must be within 1.2 km.

•

Turn ON the equipment terminator (termination resistance: 100 Ω) at both ends of the RS-485 connection (marked with * in the figure above).

•

Turn ON/OFF the N-48 terminator using the terminator switch. (➮ See p. 7.)

•

Turn ON/OFF the N-400 terminator using the terminator switch. (➮ See p. 6.)

Note: Be sure not to connect the RS-485 cable using the terminal block. Incorrect

Correct

Note 1: Do not place the RS-485 cable in the same conduit as a power cable. Note 2: Do not branch the RS-485 connection as shown below. Incorrect (Connection with branch)

N-48

N-48

C orrect (Connection without branch)

N-400

N-48

N-48

N-400

*

* N-48

N-48 * Terminator ON

20

Page 29

Chapter 2

2.4

Installation Procedure

Connecting BL-U1 and Wiring To use the BL-U1 AC power supply, connect it as described below.

2.4.1 Connecting power supply Plug the BL-U1 power cable into an outlet.

2 FG line

CAUTION

Use a power supply of 100 to 240 VAC ± 10% (50/60 Hz).

2.4.2 Connecting BL series Connect the BL series to the READER port of the BL-U1.

BL-U1 READER port pin assignment 1 2 3 4 5

6 7 8 9

Pin No.

D-sub 9-pin (male) DCE specification (defined as terminal) #4-40 screw (female)

Symbol

Function

1

TIM

Trigger input

Signal direction Output

2

RD (RXD)

Receives RS-232C data.

Output

3

SD (TXD)

Sends RS-232C data.

Input

4

OK

OK

Input

5

GND (SG)

Ground (Common ground for respective signal), 6

NG

NG

Input

7

RS (RTS)

Ready to send RS-232C data.

Input

8

CS (CTS)

Request to send RS-232Cdata. Output (Control method can be selected with the DIP switches. See p. 22.)

9

+5 V

+5 V power supply (1.5 A)

Output

21

Page 30

Chapter 2

Installation Procedure

2.4.3 Setting BL-U1 DIP switches Switch the interface setting to “RS-485 multi-drop” using the BL-U1 DIP switches. Switch the RS-485 terminator according to p. 25.

OFF

ON

* The figure on the left shows the default settings. 1

2

3

4

5

6

2 DIP Switch No. Interface selection

22

1

2

3

RS-232C

ON OFF OFF

RS-422A

OFF ON OFF

RS-485 multidrop

OFF OFF ON

4

5

6

RS-422A terminator

OFF

OFF

(Termination resistance: 100 Ω)

ON

ON

RS-485 terminator

OFF

OFF

(Termination resistance: 100 Ω)

ON

ON

Selection of READER port CS control method

ON or OFF according to the RS-232C port CS signal status.

OFF

Normally ON

ON