Manual · Keyence
N-400 User's Manual: Multi-Drop Controller for BL Series
Manual150 pagesPDF 1.3 MB
User's manual for the Keyence N-400 multi-drop controller that links BL series bar code readers to a host computer or PLC.
Covers · 1 model
The models it covers
Summary
What is in it
Keyence user's manual for the N-400 multi-drop controller for BL series bar code readers (BL-700, BL-180 and BL-500 series), used with the N-48 or BL-U1 units. It covers installation and RS-232C and RS-485 wiring, mounting, the Windows setup software, multi-drop link mode, multi-head scan mode with interference suppression, and the PLC link function. Appendices give specifications, dimensions, sample programs, troubleshooting and parameter lists.
Its parts
- Overview of the N-400
- Installation Procedure
- N-400 Setup Procedure
- Multi-Drop Link Mode Control Procedure
- Multi-Head Mode Control Procedure
- PLC Link
From the manual
Key facts from this manual
Each line names its page in the PDF.
The Keyence user's manual for the N-400 multi-drop controller for BL series bar code readers, which also describes the N-48 and BL-U1 power supply units used with it. It explains multi-drop link, multi-head scan and PLC link modes, wiring, setup software, specifications, troubleshooting and the N-400's display codes.
- Device
- Multi-drop controller letting one host computer control up to 31 BL series readers over RS-485, up to 1.2 km p. 10
- Connectable readers
- BL-700, BL-500 and BL-180 series bar code readers p. 128
- Power
- 24 VDC +10%/-20%, 140 mA max. p. 128
- Ports
- RS-232C D-sub 25-pin (male) for a host computer or PLC; RS-485 terminal; trigger input terminal; 24 VDC power terminal p. 13, 21
- Communication
- RS-232C and RS-485, 600 to 38400 bps, ASCII, 7 or 8 data bits, even/odd/none parity, 1 or 2 stop bits p. 128
- Trigger input
- Rated 15 to 26 VDC, 10 mA max.; max. OFF current 1.0 mA; used in multi-head scan mode p. 13, 128
- Environment
- 0 to 50°C (32 to 122°F), no freezing; 35 to 85% RH, no condensation; no dust or corrosive gas p. 128
- Weight
- Approx. 180 g p. 128
- Error codes
- 99 unit defective; 98 EEPROM memory error (settings initialized); 97 buffer data overflow; 95 or 96 PLC link error p. 141
- PLC link
- KEYENCE KV series, Mitsubishi MELSEC-A series, OMRON SYSMAC-C, SYSMAC-CQM1 and SYSMAC-CV series p. 110
- PC cable
- OP-98769 (1.5 m); add the OP25057 conversion connector for a 9-pin IBM PC port p. 21
- Reader power units
- N-48 (24 VDC) or BL-U1 (100 to 240 VAC); the BL-U1 is not available in Europe, where BL-U2 is used p. 4, 14, 15
- N-48 unit
- N-48: RS-232C & RS-485 level conversion; 24 VDC +10%/-20%, 260 mA max.; approx. 100 g p. 129
- Package contents
- N-400, User's Manual and N-400 setup software p. 4
What this manual walks you through
- Choosing between multi-drop link, multi-head scan and PLC link modes p. 10, 11
- Planning the system configuration p. 12
- Identifying the parts and indicator LEDs of the N-400, N-48 and BL-U1 p. 13, 14, 15
- Wiring the terminal block, power supply and trigger input p. 20, 21
- Connecting the RS-232C port to a personal computer p. 21
- Setup software error messages p. 63
- Setting up a PLC link and its memory areas p. 110, 111
- Specifications of the N-400, N-48 and BL-U1 p. 128, 129
- Troubleshooting failed communication p. 139, 140
- Reading the N-400 status and error codes p. 141
Good to know
- Use only a 24 VDC supply; a higher voltage or AC may damage the unit. For UL compliance the supply needs NEC class 2 output. p. 20
- Pin 25 of the RS-232C port is a 5 V output; leave it unconnected when unused, never tied to ground. p. 21
- With interference suppression the readers fire in turn, so with many units they may miss codes if the line runs too fast. p. 11
- Over a PLC link the PLC cannot change settings or send commands to the N-400 or readers; ID numbers are registered with the setup software. p. 110
- The N-400 must not be used to protect the human body. p. 3
Questions this manual answers
What does error 97 mean on a Keyence N-400?
A data overflow in the N-400's buffer; press the test switch to reset it. p. 141
What power supply does the N-400 need?
24 VDC (+10%/-20%), drawing up to 140 mA; AC or more than 24 VDC may damage it. p. 20, 128
Which PLCs can the N-400 PLC link write to?
KEYENCE KV series, Mitsubishi MELSEC-A series and OMRON SYSMAC-C, SYSMAC-CQM1 and SYSMAC-CV series, through the listed CPU ports and link units. p. 110
How many BL readers can one N-400 control, and how far?
Up to 31 BL series readers, over a total RS-485 cable extension of up to 1.2 km. p. 128
What should I check when the N-400 cannot talk to the readers?
Run the connection test mode, then check power, matching RS-485 parameters, multi-drop mode on each reader, unique ID numbers, cable length and terminators. p. 139
Contents
Chapters and sections
Each line opens the PDF at its page.
- N-400 User's Manual1
- Software License Agreement2
- Safety Precautions3
- Warnings and Cautions Specific to the N-4003
- List of Package Contents4
- Chapter 1 Overview of the N-4009
- Chapter 2 Installation Procedure17
- Chapter 3 N-400 Setup Procedure39
- Chapter 4 Multi-Drop Link Mode Control Procedure65
- Chapter 5 Multi-Head Mode Control Procedure95
- Chapter 6 PLC Link109
- Appendices127
- WARRANTIES AND DISCLAIMERS:149
The whole text · 15 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 101-10
- Pages 11 to 2011-20
- Pages 21 to 3021-30
- Pages 31 to 4031-40
- Pages 41 to 5041-50
- Pages 51 to 6051-60
- Pages 61 to 7061-70
- Pages 71 to 8071-80
- Pages 81 to 9081-90
- Pages 91 to 10091-100
- Pages 101 to 110101-110
- Pages 111 to 120111-120
- Pages 121 to 130121-130
- Pages 131 to 140131-140
- Pages 141 to 150141-150
The file