The text of a manual · part 6 of 15

N-400 User's Manual: Multi-Drop Controller for BL Series, pages 51 to 60

Pages 51 to 60 of 150

The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Keyence N-400

Page 51

Chapter 3

N-400 Setup Procedure

RS-485 The RS-485 screen is used to set the RS-485 communication parameters for the N-400. Set these parameters so that they conform to those of the connected BL series.

3

Note: We recommend that you set the baud rate to “38400 bits/s” to increase the processing speed, since the RS-485 communication between the N-400 and the BL series transfers a large volume of data.

43

Page 52

Chapter 3

N-400 Setup Procedure

3.3.2 Reading/Saving/Printing File The FILES screen is used to save updated settings in a file, to read a saved setting file, and to print the contents of a setting file.

3

•

Open: Reads a saved setting file.

•

Save: Saves updated settings in a file.

•

Compare: Compares the settings currently edited with a file previously saved.

•

Print: Prints contents of a setting file.

•

Default (Initialize settings): Restores updated settings to the default settings.

•

Version info: Displays the version information of this software.

Reading a previously saved setting file 1. To read a previously saved setting file, click on [Open]. The following screen will appear.

2. When you click on [OK] after selecting a file, the selected file can be opened.

44

Page 53

Chapter 3

N-400 Setup Procedure

Saving updated settings in a file 1. To save updated settings in a file, click on [Save]. The following screen will appear.

3

2. Click on the file name entry field, and enter a file name using the keyboard. Specify a file name within eight characters. Be sure to add the extension “NCF”. After entering the file name, click on [OK] to save the file.

Note: This software cannot accept a long file name in Windows 95.

Tips

When the saved setting file is sent to the N-400, the name of the file is simultaneously sent to the N-400. When you read the settings of the N-400 using this software, the file name is also read. It is convenient for maintenance since you can find the file that stores the settings. To enter a file name, use alphanumerics (letters and numbers) only. Otherwise, the file name cannot be sent to the N-400, because it can only recognize alphanumerics. To send a file name, be sure to enter the file name using alphanumerics and then save it. (If the file name is not saved, it cannot be sent to the N-400.)

45

Page 54

Chapter 3

N-400 Setup Procedure

Comparing the settings currently edited with a saved file 1. To compare the settings currently edited with the setting file previously saved, click on [Compare].

3

2. Select a file to be compared, and click on [OK]. Then, the system compares the selected file with the settings currently edited, and displays the result. Matched

46

Not matched

Page 55

Chapter 3

N-400 Setup Procedure

Printing contents of a setting file 1. To print settings, click on [Print]. The following screen will appear.

3 2. Adjust “Printer Setup” as required, and click on [OK]. Printing will then start.

Restoring the settings currently edited to the default (initial) settings 1. To restore the settings currently being edited to the default settings, click on [Default (Initialize settings)]. 2. If you try to initialize the settings currently being edited without saving them, the following message appears. If you wish to execute initialization, click on [OK].

Note: The initialization procedure described in this section is used to initialize the settings being edited with the setup software. The settings on the N-400 cannot be initialized.

47

Page 56

Chapter 3

3.4

N-400 Setup Procedure

Sending/Receiving Settings

Sending updated settings to the N-400 To send updated settings to the N-400, perform the following procedure. 1. Press and hold the N-400 test switch for five seconds. When the N-400 displays “S0 (50)”, the communication parameters are temporarily set as follows:

3 Tips

•

Baud rate: 9600 bits/s

•

Step bit length: 1 bit

•

Data length: 7 bits

•

PLC link: Disabled

•

Parity: Even

If you know the current communication parameter settings of the N-400, this step is not necessary. You can send data to the N-400 by setting the communication parameters of the host computer using [COM PORT] so that they conform to the current settings of the N-400. However, if PLC link is enabled, you cannot send data to the N-400 without performing this step because the handshaking protocol is set for PLC link only. 2. Click on [COM PORT] to set the communication parameters of the host computer according to the values listed in the step 1. (above procedure). Select an RS-232C port, and click on [OK].

3. Click on [Send setting (Save in N-400 EEP-ROM]. The updated settings are then sent to the N-400.

48

Page 57

Chapter 3

N-400 Setup Procedure

4. If the settings were successfully sent to the N-400, the following message appears.

If the host computer failed to send the data to the N-400, the following message appears.

3

If this message is displayed, check the following points: •

• •

Check that [COM PORT] is set to the values listed in step 1. when the N400 displays “S0 (50)”. Check that the power to the N-400 is ON. Check that the RS-232C cable pin assignment of the N-400 is the same as that of the host computer.

5. After the settings are sent, press the N-400 test switch once to reset the “S0 (50)” condition. (If the N-400 does not display “S0 (50)”, you do not need to press the test switch. ) When the N-400 displays “00”, the sending procedure is completed. (The communication parameters of the N-400 are set to the updated settings.)

49

Page 58

Chapter 3

N-400 Setup Procedure

Reading the current settings of the N-400 To read the current settings of the N-400, perform the following procedure. (This procedure is almost the same as the procedure for sending settings.) 1. Press and hold the N-400 test switch for five seconds. When the N-400 displays “S0 (50)”, the communication parameters are temporarily set as follows:

3

Tips

•

Baud rate: 9600 bits/s

•

Data length: 7 bits

•

Parity: Even

•

Step bit length: 1 bit

•

PLC link: Disabled

If you know the current communication parameter settings of the N-400, step 1. is not necessary. You can send data to the N-400 by setting the communication parameters of the host computer using [COM PORT] so that they conform to the current settings of the N-400. However, if PLC link is enabled, you cannot send data to the N-400 without performing step 1., because the handshaking protocol is set for PLC link only. 2. Click on [COM PORT] to set the communication parameters of the host computer according to the values listed in step 1. Select an RS-232C port and click on [OK].

3. Click on [Send setting (Save in N-400 EEP-ROM)]. When you click on [Read N-400 settings], the settings of the N-400 can be read on the host computer.

50

Page 59

Chapter 3

N-400 Setup Procedure

4. If the settings of the N-400 were successfully read, the following message appears.

If the host computer failed to read the data, the following message appears.

3

If this message is displayed, check the following points: •

• •

Check that [COM PORT] is set to the values listed in step 1. when the N400 displays “S0 (50).” Check that the power to the N-400 is ON. Check that the RS-232C cable pin assignment of the N-400 is the same as that of the host computer.

5. After the settings are read, press the N-400 test switch once to reset the “S0 (50)” condition. (If the N-400 does not display “S0 (50)”, you do not need to press the test switch. ) When the N-400 displays “00”, the reading procedure is completed.

51

Page 60

Chapter 3

3.5

N-400 Setup Procedure

Using Monitor This setup software provides the “Monitor” program to check if the N-400 can send data properly. The “Monitor” program allows you to display the data read by the BL series on the host computer’s monitor screen, and also to send a command from the host computer to the N-400 or BL series. 1. Click on [COM PORT] to set the communication parameters of the host computer according to the current settings of the N-400. 2. Click on [Monitor]. The MONITOR screen will appear.

3

3. When the BL series reads bar codes, the data read by the BL series is listed on the screen (in the [Received Data] field). A record of up to 1000 lines of data can be obtained. Using the scroll bar at the right of the [Received Data] field, you can see the previous data.

4. If you click [Stop], received data is not listed. (The button name is changed to [Start].) If you try to display received data again, click on [Start].

52