Page 29

GETTING STARTED

CHAPTER

1

In This Chapter... Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–2 Conventions Used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–3 DL205 System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–4 Programming Methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–7 DirectLOGIC™ Part Numbering System . . . . . . . . . . . . . . . . . . . . . .1–8 Quick Start for PLC Validation and Programming . . . . . . . . . . . . . .1–10 Steps to Designing a Successful System . . . . . . . . . . . . . . . . . . . . .1–13

Page 30

Chapter 1: Getting Started

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D

Introduction

1–2

The Purpose of this Manual Thank you for purchasing our DL205 family of products. This manual shows you how to install, program, and maintain the equipment. It also helps you understand how to interface them to other devices in a control system. This manual contains important information for personnel who will install DL205 PLCs and components and for the PLC programmer. If you understand PLC systems, our manuals will provide all the information you need to start and keep your system up and running.

Where to Begin If you already understand PLCs please read Chapter 2, “Installation, Wiring, and Specifications”, and proceed on to other chapters as needed. Keep this manual handy for reference when you have questions. If you are a new DL205 customer, we suggest you read this manual completely to understand the wide variety of features in the DL205 family of products. We believe you will be pleasantly surprised with how much you can accomplish with our products.

Supplemental Manuals If you have purchased operator interfaces or DirectSOFT, you will need to supplement this manual with the manuals that are written for these products.

Technical Support We strive to make our manuals the best in the industry. We rely on your feedback to let us know if we are reaching our goal. If you cannot find the solution to your particular application, or, if for any reason you need technical assistance, please call us at: 770–844–4200 Our technical support group will work with you to answer your questions. They are available Monday through Friday from 9:00 A.M. to 6:00 P.M. Eastern Time. We also encourage you to visit our web site where you can find technical and non-technical information about our products and our company. http://www.automationdirect.com If you have a comment, question or suggestion about any of our products, services, or manuals, please fill out and return the ‘Suggestions’ card that was included with this manual.

DL205 User Manual, 4th Edition, Rev. A

Page 31

Chapter 1: Getting Started

Conventions Used When you see the “notepad” icon in the left–hand margin, the paragraph to its immediate right will be a special note. The word NOTE in boldface will mark the beginning of the text. When you see the “exclamation mark” icon in the left–hand margin, the paragraph to its immediate right will be a warning. This information could prevent injury, loss of property, or even death (in extreme cases). The word WARNING in boldface will mark the beginning of the text.

Key Topics for Each Chapter The beginning of each chapter will list the key topics that can be found in that chapter.

Getting Started

CHAPTER

1

In This Chapter... General Information .................................................................1-2 Specifications...........................................................................1-4

DL205 User Manual, 4th Edition, Rev. A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D

1–3

Page 32

Chapter 1: Getting Started

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D

DL205 System Components

1–4

The DL205 family is a versatile product line that provides a wide variety of features in an extremely compact package. The CPUs are small, but offer many instructions normally only found in larger, more expensive systems. The modular design also offers more flexibility in the fast moving industry of control systems. The following is a summary of the major DL205 system components.

CPUs There are four feature-enhanced CPUs in this product line, the DL230, DL240, DL250–1 and DL260. All CPUs include built-in communication ports. Each CPU offers a large amount of program memory, a substantial instruction set and advanced diagnostics. The DL250–1 features drum timers, floating–point math, 4 built-in PID loops with automatic tuning and 2 bases of local expansion capability. The DL260 features ASCII IN/OUT and extended MODBUS communications, table and trigonometric instructions, 16 PID loops with autotuning and up to 4 bases of local expansion. Details of these CPU features and more are covered in Chapter 3, CPU Specifications and Operation.

Bases Four base sizes are available: 3, 4, 6 and 9 slot. The DL205 PLCs use bases that can be expanded. The part numbers for these bases end with –1. These bases have a connector for local expansion located on the right end of the base. They can serve in local, local expansion and remote I/O configurations. All bases include a built-in power supply. The bases with the –1 suffix can replace existing bases without a suffix if expansion is required.

I/O Configuration The DL230 and DL240 CPUs can support up to 256 local I/O points. The DL250–1 can support up to 768 local I/O points with up to two expansion bases. The DL260 can support up to 1280 local I/O points with up to four expansion bases. These points can be assigned as input or output points. The DL240, DL250–1 and DL260 systems can also be expanded by adding remote I/O points. The DL250–1 and DL260 provide a built–in master for remote I/O networks. The I/O configurations are explained in Chapter 4, System Design and Configuration. I/O Modules

I/O Modules The DL205 has some of the most powerful modules in the industry. A complete range of discrete modules which support 24 VDC, 110/220 VAC and up to 10A relay outputs (subject to derating) are offered. The analog modules provide 12 and 16 bit resolution and several selections of input and output signal ranges (including bipolar). Several specialty and communications modules are also available.

DL205 User Manual, 4th Edition, Rev. A

Page 33

Chapter 1: Getting Started

DL205 System Diagrams The diagram below shows the major components and configurations of the DL205 system. The next two pages show specific components for building your system.

Machine Control

Packaging Conveyors

Simple Motion Control

Elevators

Flexible solutions in one package High-speed counting (up to 100 KHz) Pulse train output (up to 50KHz High–speed Edge timing

Handheld Programmer DL240

DL260 with H2–CTRIO High Speed I/O Module

Stepper Motor

Pulse Output

RS232C (max.50ft/16.2m) Programming or Computer Interface

Local I/O Expansion

Simple programming through the RLL Program

Drive Amplifier

Networking Programming or Computer Interface

Operator Interface DCM

Handheld Programmer RS232C (max.50ft/16.2m) DL240

RS232C (max.50ft/16.2m)

(max. 6.5ft / 2m) DL250–1 or DL260 DL305

RS232/422 Convertor

RS232/422 Convertor

DL205 User Manual, 4th Edition, Rev. A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D 1–5

Page 34

Chapter 1: Getting Started

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D 1–6

Direct LOGIC DL205 Family DC INPUT 8pt 12–24 VDC 16pt 24 VDC 32pt 24 VDC 32pt 5–15 VDC DC OUTPUT 4pt 12–24 VDC 8pt 12–24 VDC 16pt 12–24 VDC 2 Commons 32pt 12–24 VDC 4 Commons

AC INPUT 8pt 110 VAC 16pt 110 VAC AC OUTPUT 8pt 18–220 VAC 12pt 18–110 VAC 2 commons

RELAY OUTPUT 4pt 5–30 VDC 5–240VAC 8pt 5–30 VDC 5 –240 VAC 12pt 5–30VDC 5–240VAC (isolated pts.module available)

CPUs DL230 – 2.0K Built-in EEPROM Memory DL240 – 2.5K Built-in EEPROM Memory DL250–1 – 7.6K Built-in Flash Memory DL260 – 15.8K Built-in Flash Memory BASES 3 Slot Base, 110/220VAC, 24VDC 4 Slot Base, 110/220VAC, 24VDC 6 Slot Base, 110/220VAC, 24VDC, 125 VDC 9 Slot Base, 110/220VAC, 24VDC, 125 VDC

SPECIALTY MODULES High Speed Counters CPU Slot Controllers Remote Masters Remote Slaves Communications Temperature Input Filler Module

PROGRAMMING Handheld Programmer with Built-in RLL PLUS Direct SOFT Programming for Windows

DL205 User Manual, 4th Edition, Rev. A

ANALOG 4CH INPUT 8CH INPUT 2CH OUTPUT 8CH OUTPUT 4 IN/2 OUT 8 IN/4 OUT

Page 35

Chapter 1: Getting Started

Programming Methods There are two programming methods available for the DL205 CPUs, RLL (Relay Ladder Logic) and RLLPLUS (Stage Programming). Both the DirectSOFT5 programming package and the handheld programmer support RLL and Stage.

DirectSOFT Programming for Windows. The DL205 can be programmed with one of the most advanced programming packages in the industry ––DirectSOFT5. DirectSOFT5 is a Windows-based software package that supports many Windows features you already know, such as cut and paste between applications, point and click editing, viewing and editing multiple application programs at the same time, etc. DirectSOFT5 universally supports the DirectLOGIC CPU families. This means you can use the same DirectSOFT5 package to program DL05, DL06, DL105, DL205, DL305, DL405 or any new CPUs we may add to our product line. There is a separate manual that discusses the DirectSOFT5 programming software which is included with your software package.

Handheld Programmer All DL205 CPUs have a built-in programming port for use with the handheld programmer (D2–HPP). The handheld programmer can be used to create, modify and debug your application program. A separate manual that discusses the DL205 Handheld Programmer is available.

DL205 User Manual, 4th Edition, Rev. A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D 1–7

Page 36

Chapter 1: Getting Started

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D

DirectLOGIC™ Part Numbering System

1–8

As you examine this manual, you will notice there are many different products available. Sometimes it is difficult to remember the specifications for any given product. However, if you take a few minutes to understand the numbering system, it may save you some time and confusion. The charts below show how the part numbering systems work for each product category. Part numbers for accessory items such as cables, batteries, memory cartridges, etc., are typically an abbreviation of the description for the item. CPUs Specialty CPUs DL05/06 Product family DL105 Product family DL205 Product family DL305 Product family DL405 Product family

D0/F0 D1/F1 D2/F2 D3/F3 D4/F4

Class of CPU / Abbreviation

230...,330...,430...

Denotes a differentiation between similar modules

–1, –2, –3, –4

D4–

440DC

–1

D3–

05B

DC

Bases DL205 Product family DL305 Product family DL405 Product family

D2/F2 D3/F3 D4/F4

Number of slots Type of Base

##B DC or empty

Discrete I/O DL05/06 Product family DL205 Product family DL305 Product family DL405 Product family

D0/F0 D2/F2 D3/F3 D4/F4

Number of points

04/08/12/16/32/64

Input

N

Output

T

Combination AC

C A

DC

D

Either

E

Relay Current Sinking

R 1

Current Sourcing

2

Current Sinking/Sourcing High Current

3 H

Isolation

S

Fast I/O Denotes a differentiation between similar modules

F –1, –2, –3, –4

DL205 User Manual, 4th Edition, Rev. A

D4–

16

N

D

2

D3–

16

N

D

2

F –1

Page 37

Chapter 1: Getting Started

–8

Analog I/O

F3–

DL05/06 Product family

D0/F0

DL205 Product family

D2/F2

DL305 Product family

D3/F3

DL405 Product family Number of channels

D4/F4 02/04/08/16

Input (Analog to Digital)

AD

Output (Digital to Analog)

DA

Combination Isolated

AND S

Denotes a differentiation between Similar modules

–1, –2, –3, –4

Communication and Networking Special I/O and Devices

04

AD

S

–1

Alternate example of Analog I/O using abbreviations F3–

08

THM

D4–

DCM

DCM (Data Communication Module)

D3–

HSC

D3–

HPP

HSC (High Speed Counter) HPP (RLL PLUS Handheld Programmer)

F4–

CP

128

Programming DL205 Product family

D2/F2

DL305 Product family

D3/F3

DL405 Product family

D4/F4

Name Abbreviation see example

CoProcessors and ASCII BASIC Modules DL205 Product family

D2/F2

DL305 Product family

D3/F3

DL405 Product family

D4/F4

CoProcessor

CP

ASCII BASIC

AB

64K memory

64

128K memory

128

512K memory Radio modem

512 R

Telephone modem

T

–n note: –n indicates thermocouple type such as: J, K, T, R, S or E

– R

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D

DL205 User Manual, 4th Edition, Rev. A

1–9

Page 38

Chapter 1: Getting Started

Quick Start for PLC Validation and Programming

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D 1–10

If you have experience using PLCs, or want to setup a quick example, this section is what you want to use. This example is not intended to explain everything needed to start-up your system. It is only intended to provide a general picture of what is needed to get your system powered-up.

Step 1: Unpack the DL205 Equipment Unpack the DL205 equipment and verify you have the parts necessary to build this demonstration system. The minimum parts needed are as follows: • Base • CPU • A discrete input module such as a D2–16ND3–2 DC or a F2–08SIM input simulator module • A discrete output module such as a D2–16TD1–2 DC • *Power cord • *Hook up wire • *One or more toggle switches (if not using the input simulator module) • *A screwdriver, blade or Phillips type *These items are not supplied with your PLC.

You will need at least one of the following programming options: • DirectSOFT5 Programming Software, DirectSOFT5 Manual, and a programming cable (connects the CPU to a personal computer), or • D2–HPP Handheld Programmer and the Handheld Programmer Manual.

DL205 User Manual, 4th Edition, Rev. A

Page 39

Chapter 1: Getting Started

Step 2: Install the CPU and I/O Modules Insert the CPU and I/O into the base. The CPU must be inserted into the first slot of the base (next to the power supply).

1 • Each unit has a plastic retaining clip at the top and 2 bottom. Slide the retainer clips to the out position before installing the module. 3 • With the unit square to the base, slide it in using the upper and lower guides. • Gently push the unit back until it is firmly seated in the backplane. 4 • Secure the unit to the base by pushing in the retainer clips. 5 Placement of discrete, analog and relay modules are not critical and may go in any slot in any base, however for this example, install the output module in the slot next to the CPU and the input module in the next. Limiting factors for other types of modules are discussed in 6 Chapter 4, System Design and Configuration. You must also make sure you do not exceed the power budget for each base in your system configuration. Power budgeting is also 7 discussed in Chapter 4. Step 3: Remove Terminal Strip Access Cover 8 Remove the terminal strip cover. It is a small strip of clear plastic that is located on the base power supply. 9 Step 4: Add I/O Simulation 10 To finish this quick start exercise or study other examples in this manual, you will need to install an input simulator module (or wire an input switch as shown below), and add an output module. Using an input simulator is the quickest way to get physical inputs for 11 checking out the system or a new program. To monitor output status, any discrete output module will work. 12 13 14 A B C Wire the switches or other field devices prior to applying power to the system to ensure a point is not accidentally turned on during the wiring operation. This example uses DC input and output modules. Wire the input module, X0, to the toggle switch and 24VDC auxiliary D power supply on the CPU terminal strip as shown. Chapter 2, Installation, Wiring, and Retaining Clips

CPU must reside in first slot!

Lift off

Toggle switch

Output Module

Input Module

Specifications provides a list of I/O wiring guidelines.

DL205 User Manual, 4th Edition, Rev. A

1–11

Page 40

Chapter 1: Getting Started

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D 1–12

Step 5: Connect the Power Wiring Connect the wires as shown. Observe all precautions stated earlier in this manual. For details on wiring see Chapter 2 Installation, Wiring, and Specifications. When the wiring is complete, replace the CPU and module covers. Do not apply power at this time.

Line Neutral Ground

Step 6: Connect the Programmer Either connect the programming cable connected to a computer loaded with DirectSOFT Programming Software or a D2-HPP Handheld Programmer (comes with programming cable) to the top port of the CPU.

Step 7: Switch On the System Power Apply power to the system and ensure the PWR indicator on the CPU is on. If not, remove power from the system, check all wiring and refer to the troubleshooting section in Chapter 9 for assistance.

Step 8: Enter the Program Slide the switch on the CPU to the STOP position (250–1 / 260 only) and then back to the TERM position. This puts the CPU in the program mode and allows access to the CPU program. Edit a DirectSOFT program using the relay ladder diagram below and load it into the PLC. If using an HPP, the PGM indicator should be illuminated on the HPP. Enter the following keystrokes on the HPP: NOTE: It is not necessary for you to configure the I/O for this system since the DL205 CPUs automatically examine any installed modules and establish the correct configuration.

X0

Handheld Program Keystrokes B

$ STR GX OUT

1 C 2

Y0

ENT ENT

END

After entering the example program put the CPU in the RUN mode with DirectSOFT or after entering the program using the HPP, slide the switch from the TERM position to the RUN position and back to TERM. The RUN indicator on the CPU will come on indicating the CPU has entered the run mode. If not repeat Step 8 insuring the program is entered properly or refer to the troubleshooting guide in chapter 9. During Run mode operation, the output status indicator “0” on the output module should reflect the switch status. When the switch is on the output should be on.

DL205 User Manual, 4th Edition, Rev. A

Page 41

Chapter 1: Getting Started

Steps to Designing a Successful System Step 1: Review the Installation Guidelines Always make safety your first priority in any system application. Chapter 2 provides several guidelines that will help provide a safer, more reliable system. This chapter also includes wiring guidelines for the various system components.

Step 2: Understand the CPU Setup Procedures The CPU is the heart of your automation system and is explained in Chapter 3. Make sure you take time to understand the various features and setup requirements.

Step 3: Understand the I/O System Configurations It is important to understand how your local I/O system can be configured. It is also important to understand how the system Power Budget is calculated. This can affect your I/O placement and/or configuration options. See Chapter 4 for more information.

16pt Input

8pt Input

8pt Output

X0 X17

X20 X27

Y0 Y7

Step 4: Determine the I/O Module Specifications and Wiring Characteristics There are many different I/O modules available with the DL205 system. Chapter 2 provides the specifications and wiring diagrams for the discrete I/O modules.

NOTE: Analog and specialty modules have their own manuals and are not included in this manual.

Step 5: Understand the System Operation Before you begin to enter a program, it is very helpful to understand how the DL205 system processes information. This involves not only program execution steps, but also involves the various modes of operation and memory layout characteristics. See Chapter 3 for more information.

Power up Initialize hardware Check I/O module config. and verify

DL205 User Manual, 4th Edition, Rev. A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D

1–13

Page 42

Chapter 1: Getting Started

Step 6: Review the Programming Concepts

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D 1–14

The DL205 provides four main approaches to solving the application program, including the PID loop task depicted in the next figure. • RLL diagram style programming is the best tool for solving boolean logic and general CPU register/ accumulator manipulation. It includes dozens of instructions, which will augment drums, stages and loops. • The DL250-1 and DL260 have four timer/event drum types, each with up to 16 steps. They offer both time and/or event-based step transitions. Drums are best for a repetitive process based on a single series of steps. • Stage programming, called RLLPLUS, is based on state-transition diagrams. Stages divide the ladder program into sections which correspond to the states in a flow chart of your process. • The DL260 PID loop operation uses setup tables to configure 16 loops. The DL250-1 PID loop operation uses setup to configure 4 loops. Features include: auto tuning, alarms, SP ramp/soak generation and more. Standard RLL Programming (see Chapter 5) X0

Timer/Event Drum Sequencer (see Chapter 6)

LDD V1076 CMPD K309482

SP62

Y0 OUT

Stage Programming (see Chapter 7) Push–UP

PID Loop Operation (see Chapter 8)

RAISE

SP DOWN

LIGHT

UP

+ 욾씵 –

PID

Process

PV LOWER

Push– DOWN

Step 7: Choose the Instructions Once you have installed the system and understand the theory of operation, you can choose from one of the most powerful instruction sets available.

Step 8: Understand the Maintenance and Troubleshooting Procedures Equipment failures can occur at any time. Switches fail, batteries need to be replaced, etc. In most cases, the majority of the troubleshooting and maintenance time is spent trying to locate the problem. The DL205 system has many built-in features that help you quickly identify problems. Refer to Chapter 9 for diagnostics. DL205 User Manual, 4th Edition, Rev. A

TMR

T1 K30

CNT CT3 K10