Volume 1 of the AutomationDirect DL205 PLC User Manual. It covers getting started, installation and wiring, specifications for the DL205 discrete I/O modules (among them the D2-08ND3 DC input module), CPU specifications and operation for the DL230, DL240, DL250-1 and DL260 CPUs, system design and configuration including networking, and the RLL and Intelligent Box (IBox) instruction set.
Its parts
- Chapter 1: Getting Started
- Chapter 2: Installation, Wiring and Specifications
- Chapter 3: CPU Specifications and Operations
- Chapter 4: System Design and Configuration
- Chapter 5: RLL and Intelligent Box (IBOX) Instructions
From the manual
Key facts from this manual
Each line names its page in the PDF.
Volume 1 of the DL205 PLC User Manual (D2-USER-M, 4th Edition, Rev. A), covering the whole DL205 family with the DL230, DL240, DL250-1 and DL260 CPUs; the D2-08ND3 DC input module has one specification page, shared with the D2-16ND3-2. It explains system components, installation and wiring, I/O module specifications, CPU features and power budgeting.
- Inputs
- D2-08ND3: DC input module, 8 inputs (sink/source) p. 71
- Field supply
- D2-08ND3: 12-24VDC, wired sinking or sourcing p. 71
- Input current
- D2-08ND3: 4.0 mA @ 12 VDC; 8.5 mA @ 24 VDC p. 71
- Base power
- D2-08ND3: 50 mA at 5VDC p. 71
- Response time
- D2-08ND3: 1 to 8 ms OFF to ON and ON to OFF p. 71
- Terminal block
- D2-08ND3: removable D2-8IOCON, included p. 71
- Weight
- D2-08ND3: 2.3 oz. (65 g) p. 71
- Wire size
- 16-24 AWG for 4, 8, 12 and 16 point modules; 16 AWG Type TFFN or MTW recommended p. 70
- DL205 CPUs
- DL230, DL240, DL250-1 and DL260 p. 32
- DL205 bases
- 3, 4, 6 and 9 slot, each with a built-in power supply p. 32
- System power
- 110/220 VAC, 24 VDC or 125 VDC, by base p. 49
- Local I/O
- DL230 and DL240: up to 256 points; DL250-1: 768 with two expansion bases; DL260: 1280 with four p. 32
- Status indicators
- LED status indicators for the input points p. 68
- Manual number
- D2-USER-M, Volume 1 of 2 p. 1
What this manual walks you through
- DL205 system components and configurations p. 32, 33, 34
- Grounding the base and choosing an enclosure p. 49
- Environmental and base power supply specifications p. 50
- Removing and wiring the I/O module connectors p. 69, 70
- D2-08ND3 specifications, derating chart and wiring diagram p. 71
- Comparing the DL230, DL240, DL250-1 and DL260 CPU features p. 98, 99
- Calculating the base power budget p. 171, 172
Good to know
- Field device power may still be on the terminal block with the PLC turned off; check it before removing the connector. p. 69
- Exceeding the power budget may make the system operate unpredictably. p. 171
- Thick or stiff 16 AWG insulation may stop the terminal cover closing or pull the connector away. p. 70
- Aim for about 0.1 ohm of DC resistance between the base and the single point ground. p. 49
- Static electricity problems are much more frequent below 30% humidity. p. 50
Questions this manual answers
How much base power does the D2-08ND3 need?
50 mA at 5VDC from the base. p. 71
What terminal block does the D2-08ND3 use?
A removable D2-8IOCON terminal block, included with the module. p. 71
How fast does the D2-08ND3 respond?
1 to 8 ms from OFF to ON and from ON to OFF. p. 71
Which CPUs are in the DL205 family?
The DL230, DL240, DL250-1 and DL260, all with built-in communication ports. p. 32
What wire size fits DL205 I/O module terminals?
16-24 AWG for 4 to 16 point modules; 16 AWG Type TFFN or Type MTW is recommended. p. 70
Contents
Chapters and sections
Each line opens the PDF at its page.
- DL205 PLC User ManualVolume 1 of 21
- Warning3
- Publication History5
- Table of Contents for Volumes 1 & 27
- Volume One: Table of Contents7
- Chapter 1: Getting Started7
- Chapter 2: Installation, Wiring and Specifications7
- Chapter 3: CPU Specifications and Operations10
- Chapter 4: System Design and Configuration13
- Chapter 5: RLL and Intelligent Box (IBOX) Instructions15
- Volume Two: Table of Contents17
- Chapter 6: Drum Instruction Programming (DL250-1/DL260 only)17
- Chapter 7: RLLPLUS Stage Programming18
- Chapter 8: PID Loop Operation19
- Chapter 9: Maintenance and Troubleshooting21
- Appendix A: Auxiliary Functions23
- Appendix B: DL205 Error Codes24
- Appendix C: Instruction Execution Times24
- Appendix D: Special Relays25
- Appendix E: PLC Memory26
- Appendix F: DL205 Product Weight Table26
- Appendix G: ASCII Table26
- Appendix H: Numbering Systems26
- Appendix I: European Union Directives (CE)27
- Index27
- Chapter 1: Getting Started29
- Chapter 2: Installation, Wiring and Specifications43
87 more lines, from page 67 on
- I/O Modules Position, Wiring, and Specification67
- D2-08ND3, DC Input71
- D2-16ND3-2, DC Input71
- D2–32ND3, DC Input72
- D2–32ND3–2, DC Input73
- D2-08NA-1, AC Input74
- D2-08NA-2, AC Input75
- D2-16NA, AC Input76
- F2-08SIM, Input Simulator76
- D2-04TD1, DC Output77
- D2–08TD1, DC Output78
- D2–08TD2, DC Output78
- D2–16TD1–2, DC Output79
- D2–16TD2–2, DC Output79
- F2–16TD1(2)P, DC Output With Fault Protection80
- D2–32TD1, DC Output83
- D2–32TD2, DC Output83
- F2–08TA, AC Output84
- D2–08TA, AC Output84
- D2–12TA, AC Output85
- D2–04TRS, Relay Output86
- D2–08TR, Relay Output87
- F2–08TR, Relay Output88
- F2–08TRS, Relay Output89
- D2–12TR, Relay Output90
- D2–08CDR, 4 pt. DC Input / 4pt. Relay Output91
- Glossary of Specification Terms92
- Chapter 3: CPU Specifications and Operations95
- CPU Overview96
- CPU General Specifications98
- CPU Base Electrical Specifications99
- CPU Hardware Setup100
- Selecting the Program Storage Media103
- Using Battery Backup108
- CPU Operation115
- I/O Response Time121
- CPU Scan Time Considerations123
- PLC Numbering Systems129
- Memory Map131
- DL230 System V-memory135
- DL240 System V-memory137
- DL250–1 System V-memory (DL250 also)140
- DL260 System V-memory143
- DL205 Aliases146
- DL230 Memory Map147
- DL240Memory Map148
- DL250–1Memory Map (DL250 also)149
- DL260 Memory Map150
- X Input/Y Output Bit Map151
- Control Relay Bit Map153
- Stage Control/Status Bit Map157
- Timer and Counter Status Bit Maps159
- Remote I/O Bit Map160
- Chapter 4: System Design and Configuration165
- Chapter 5: RLL and Intelligent Box Instructions223
- Introduction224
- Using Boolean Instructions227
- Boolean Instructions232
- Comparative Boolean249
- Immediate Instructions255
- Timer, Counter and Shift Register Instructions263
- Accumulator/Stack Load and Output Data Instructions275
- Logical Instructions (Accumulator)293
- Math Instructions310
- Transcendental Functions (DL260 only343
- Bit Operation Instructions345
- Number Conversion Instructions (Accumulator)352
- Table Instructions366
- Clock/Calendar Instructions397
- CPU Control Instructions399
- Program Control Instructions401
- Interrupt Instructions409
- Intelligent I/O Instructions413
- Network Instructions415
- Message Instructions419
- Modbus RTU Instructions (DL260)427
- ASCII Instructions (DL260)433
- Intelligent Box (IBox) Instructions (DL250-1/DL260 Only)452
The whole text · 61 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 41-4
- Pages 5 to 125-12
- Pages 13 to 2013-20
- Pages 21 to 2821-28
- Chapter 1: Getting Started29-42
- Chapter 2: Installation, Wiring and Specifications, pages 43 to 5143-51
- Chapter 2: Installation, Wiring and Specifications, pages 52 to 6052-60
- Chapter 2: Installation, Wiring and Specifications, pages 61 to 6961-69
- Chapter 2: Installation, Wiring and Specifications, pages 70 to 7870-78
- Chapter 2: Installation, Wiring and Specifications, pages 79 to 8779-87
- Chapter 2: Installation, Wiring and Specifications, pages 88 to 9488-94
- Chapter 3: CPU Specifications and Operations, pages 95 to 10495-104
- Chapter 3: CPU Specifications and Operations, pages 105 to 114105-114
- Chapter 3: CPU Specifications and Operations, pages 115 to 124115-124
- Chapter 3: CPU Specifications and Operations, pages 125 to 134125-134
- Chapter 3: CPU Specifications and Operations, pages 135 to 144135-144
- Chapter 3: CPU Specifications and Operations, pages 145 to 154145-154
- Chapter 3: CPU Specifications and Operations, pages 155 to 164155-164
- Chapter 4: System Design and Configuration, pages 165 to 174165-174
- Chapter 4: System Design and Configuration, pages 175 to 184175-184
- Chapter 4: System Design and Configuration, pages 185 to 194185-194
- Chapter 4: System Design and Configuration, pages 195 to 204195-204
- Chapter 4: System Design and Configuration, pages 205 to 214205-214
- Chapter 4: System Design and Configuration, pages 215 to 222215-222
- Chapter 5: RLL and Intelligent Box Instructions, pages 223 to 232223-232
- Chapter 5: RLL and Intelligent Box Instructions, pages 233 to 242233-242
- Chapter 5: RLL and Intelligent Box Instructions, pages 243 to 252243-252
- Chapter 5: RLL and Intelligent Box Instructions, pages 253 to 262253-262
- Chapter 5: RLL and Intelligent Box Instructions, pages 263 to 272263-272
- Chapter 5: RLL and Intelligent Box Instructions, pages 273 to 282273-282
- Chapter 5: RLL and Intelligent Box Instructions, pages 283 to 292283-292
- Chapter 5: RLL and Intelligent Box Instructions, pages 293 to 302293-302
- Chapter 5: RLL and Intelligent Box Instructions, pages 303 to 312303-312
- Chapter 5: RLL and Intelligent Box Instructions, pages 313 to 322313-322
- Chapter 5: RLL and Intelligent Box Instructions, pages 323 to 332323-332
- Chapter 5: RLL and Intelligent Box Instructions, pages 333 to 342333-342
- Chapter 5: RLL and Intelligent Box Instructions, pages 343 to 352343-352
- Chapter 5: RLL and Intelligent Box Instructions, pages 353 to 362353-362
- Chapter 5: RLL and Intelligent Box Instructions, pages 363 to 372363-372
- Chapter 5: RLL and Intelligent Box Instructions, pages 373 to 382373-382
- Chapter 5: RLL and Intelligent Box Instructions, pages 383 to 392383-392
- Chapter 5: RLL and Intelligent Box Instructions, pages 393 to 402393-402
- Chapter 5: RLL and Intelligent Box Instructions, pages 403 to 412403-412
- Chapter 5: RLL and Intelligent Box Instructions, pages 413 to 422413-422
- Chapter 5: RLL and Intelligent Box Instructions, pages 423 to 432423-432
- Chapter 5: RLL and Intelligent Box Instructions, pages 433 to 442433-442
- Chapter 5: RLL and Intelligent Box Instructions, pages 443 to 452443-452
- Chapter 5: RLL and Intelligent Box Instructions, pages 453 to 462453-462
- Chapter 5: RLL and Intelligent Box Instructions, pages 463 to 472463-472
- Chapter 5: RLL and Intelligent Box Instructions, pages 473 to 482473-482
- Chapter 5: RLL and Intelligent Box Instructions, pages 483 to 492483-492
- Chapter 5: RLL and Intelligent Box Instructions, pages 493 to 502493-502
- Chapter 5: RLL and Intelligent Box Instructions, pages 503 to 512503-512
- Chapter 5: RLL and Intelligent Box Instructions, pages 513 to 522513-522
- Chapter 5: RLL and Intelligent Box Instructions, pages 523 to 532523-532
- Chapter 5: RLL and Intelligent Box Instructions, pages 533 to 542533-542
- Chapter 5: RLL and Intelligent Box Instructions, pages 543 to 552543-552
- Chapter 5: RLL and Intelligent Box Instructions, pages 553 to 562553-562
- Chapter 5: RLL and Intelligent Box Instructions, pages 563 to 572563-572
- Chapter 5: RLL and Intelligent Box Instructions, pages 573 to 582573-582
- Chapter 5: RLL and Intelligent Box Instructions, pages 583 to 592583-592
The file