Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of DL205 PLC User Manual, Volume 1 of 2

Manual · Koyo

DL205 PLC User Manual, Volume 1 of 2

Manual592 pagesPDF 13 MB

User manual, volume 1, for the DL205 PLC system, including wiring and specifications for the D2-08ND3 DC input module.

Download the PDF13 MB

Covers · 2 models

The models it covers

Summary

What is in it

Volume 1 of the AutomationDirect DL205 PLC User Manual. It covers getting started, installation and wiring, specifications for the DL205 discrete I/O modules (among them the D2-08ND3 DC input module), CPU specifications and operation for the DL230, DL240, DL250-1 and DL260 CPUs, system design and configuration including networking, and the RLL and Intelligent Box (IBox) instruction set.

Its parts

  1. Chapter 1: Getting Started
  2. Chapter 2: Installation, Wiring and Specifications
  3. Chapter 3: CPU Specifications and Operations
  4. Chapter 4: System Design and Configuration
  5. Chapter 5: RLL and Intelligent Box (IBOX) Instructions

From the manual

Key facts from this manual

Each line names its page in the PDF.

Volume 1 of the DL205 PLC User Manual (D2-USER-M, 4th Edition, Rev. A), covering the whole DL205 family with the DL230, DL240, DL250-1 and DL260 CPUs; the D2-08ND3 DC input module has one specification page, shared with the D2-16ND3-2. It explains system components, installation and wiring, I/O module specifications, CPU features and power budgeting.

Read for this summary: pages 1, 30, 32 to 34, 36 to 37, 49 to 50, 67 to 71, 98 to 99 and 171 to 172 of 592.

Inputs
D2-08ND3: DC input module, 8 inputs (sink/source) p. 71
Field supply
D2-08ND3: 12-24VDC, wired sinking or sourcing p. 71
Input current
D2-08ND3: 4.0 mA @ 12 VDC; 8.5 mA @ 24 VDC p. 71
Base power
D2-08ND3: 50 mA at 5VDC p. 71
Response time
D2-08ND3: 1 to 8 ms OFF to ON and ON to OFF p. 71
Terminal block
D2-08ND3: removable D2-8IOCON, included p. 71
Weight
D2-08ND3: 2.3 oz. (65 g) p. 71
Wire size
16-24 AWG for 4, 8, 12 and 16 point modules; 16 AWG Type TFFN or MTW recommended p. 70
DL205 CPUs
DL230, DL240, DL250-1 and DL260 p. 32
DL205 bases
3, 4, 6 and 9 slot, each with a built-in power supply p. 32
System power
110/220 VAC, 24 VDC or 125 VDC, by base p. 49
Local I/O
DL230 and DL240: up to 256 points; DL250-1: 768 with two expansion bases; DL260: 1280 with four p. 32
Status indicators
LED status indicators for the input points p. 68
Manual number
D2-USER-M, Volume 1 of 2 p. 1

What this manual walks you through

  • DL205 system components and configurations p. 32, 33, 34
  • Grounding the base and choosing an enclosure p. 49
  • Environmental and base power supply specifications p. 50
  • Removing and wiring the I/O module connectors p. 69, 70
  • D2-08ND3 specifications, derating chart and wiring diagram p. 71
  • Comparing the DL230, DL240, DL250-1 and DL260 CPU features p. 98, 99
  • Calculating the base power budget p. 171, 172

Good to know

  • Field device power may still be on the terminal block with the PLC turned off; check it before removing the connector. p. 69
  • Exceeding the power budget may make the system operate unpredictably. p. 171
  • Thick or stiff 16 AWG insulation may stop the terminal cover closing or pull the connector away. p. 70
  • Aim for about 0.1 ohm of DC resistance between the base and the single point ground. p. 49
  • Static electricity problems are much more frequent below 30% humidity. p. 50

Questions this manual answers

How much base power does the D2-08ND3 need?

50 mA at 5VDC from the base. p. 71

What terminal block does the D2-08ND3 use?

A removable D2-8IOCON terminal block, included with the module. p. 71

How fast does the D2-08ND3 respond?

1 to 8 ms from OFF to ON and from ON to OFF. p. 71

Which CPUs are in the DL205 family?

The DL230, DL240, DL250-1 and DL260, all with built-in communication ports. p. 32

What wire size fits DL205 I/O module terminals?

16-24 AWG for 4 to 16 point modules; 16 AWG Type TFFN or Type MTW is recommended. p. 70

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. DL205 PLC User ManualVolume 1 of 21
  2. Warning3
  3. Publication History5
  4. Table of Contents for Volumes 1 & 27
    1. Volume One: Table of Contents7
    2. Chapter 1: Getting Started7
    3. Chapter 2: Installation, Wiring and Specifications7
    4. Chapter 3: CPU Specifications and Operations10
    5. Chapter 4: System Design and Configuration13
    6. Chapter 5: RLL and Intelligent Box (IBOX) Instructions15
    7. Volume Two: Table of Contents17
    8. Chapter 6: Drum Instruction Programming (DL250-1/DL260 only)17
    9. Chapter 7: RLLPLUS Stage Programming18
    10. Chapter 8: PID Loop Operation19
    11. Chapter 9: Maintenance and Troubleshooting21
    12. Appendix A: Auxiliary Functions23
    13. Appendix B: DL205 Error Codes24
    14. Appendix C: Instruction Execution Times24
    15. Appendix D: Special Relays25
    16. Appendix E: PLC Memory26
    17. Appendix F: DL205 Product Weight Table26
    18. Appendix G: ASCII Table26
    19. Appendix H: Numbering Systems26
    20. Appendix I: European Union Directives (CE)27
    21. Index27
  5. Chapter 1: Getting Started29
    1. Introduction30
    2. Conventions Used31
    3. DL205 System Components32
    4. Programming Methods35
    5. DirectLOGIC™ Part Numbering System36
    6. Quick Start for PLC Validation and Programming38
    7. Steps to Designing a Successful System41
  6. Chapter 2: Installation, Wiring and Specifications43
    1. Safety Guidelines44
    2. Mounting Guidelines47
    3. Installing DL205 Bases52
    4. Installing Components in the Base54
    5. Base Wiring Guidelines55
    6. I/O Wiring Strategies56
87 more lines, from page 67 on
  1. I/O Modules Position, Wiring, and Specification67
    1. D2-08ND3, DC Input71
    2. D2-16ND3-2, DC Input71
    3. D2–32ND3, DC Input72
    4. D2–32ND3–2, DC Input73
    5. D2-08NA-1, AC Input74
    6. D2-08NA-2, AC Input75
    7. D2-16NA, AC Input76
    8. F2-08SIM, Input Simulator76
    9. D2-04TD1, DC Output77
    10. D2–08TD1, DC Output78
    11. D2–08TD2, DC Output78
    12. D2–16TD1–2, DC Output79
    13. D2–16TD2–2, DC Output79
    14. F2–16TD1(2)P, DC Output With Fault Protection80
    15. D2–32TD1, DC Output83
    16. D2–32TD2, DC Output83
    17. F2–08TA, AC Output84
    18. D2–08TA, AC Output84
    19. D2–12TA, AC Output85
    20. D2–04TRS, Relay Output86
    21. D2–08TR, Relay Output87
    22. F2–08TR, Relay Output88
    23. F2–08TRS, Relay Output89
    24. D2–12TR, Relay Output90
    25. D2–08CDR, 4 pt. DC Input / 4pt. Relay Output91
    26. Glossary of Specification Terms92
  2. Chapter 3: CPU Specifications and Operations95
    1. CPU Overview96
    2. CPU General Specifications98
    3. CPU Base Electrical Specifications99
    4. CPU Hardware Setup100
    5. Selecting the Program Storage Media103
    6. Using Battery Backup108
    7. CPU Operation115
    8. I/O Response Time121
    9. CPU Scan Time Considerations123
    10. PLC Numbering Systems129
    11. Memory Map131
    12. DL230 System V-memory135
    13. DL240 System V-memory137
    14. DL250–1 System V-memory (DL250 also)140
    15. DL260 System V-memory143
    16. DL205 Aliases146
    17. DL230 Memory Map147
    18. DL240Memory Map148
    19. DL250–1Memory Map (DL250 also)149
    20. DL260 Memory Map150
    21. X Input/Y Output Bit Map151
    22. Control Relay Bit Map153
    23. Stage Control/Status Bit Map157
    24. Timer and Counter Status Bit Maps159
    25. Remote I/O Bit Map160
  3. Chapter 4: System Design and Configuration165
    1. DL205 System Design Strategies166
    2. Module Placement167
    3. Calculating the Power Budget171
    4. Local Expansion I/O175
    5. Expanding DL205 I/O181
    6. Network Connections to Modbus and DirectNET196
    7. Network Slave Operation199
    8. Network Modbus RTU Master Operation (DL260 only)209
    9. Non–Sequence Protocol (ASCII In/Out and PRINT)218
  4. Chapter 5: RLL and Intelligent Box Instructions223
    1. Introduction224
    2. Using Boolean Instructions227
    3. Boolean Instructions232
    4. Comparative Boolean249
    5. Immediate Instructions255
    6. Timer, Counter and Shift Register Instructions263
    7. Accumulator/Stack Load and Output Data Instructions275
    8. Logical Instructions (Accumulator)293
    9. Math Instructions310
    10. Transcendental Functions (DL260 only343
    11. Bit Operation Instructions345
    12. Number Conversion Instructions (Accumulator)352
    13. Table Instructions366
    14. Clock/Calendar Instructions397
    15. CPU Control Instructions399
    16. Program Control Instructions401
    17. Interrupt Instructions409
    18. Intelligent I/O Instructions413
    19. Network Instructions415
    20. Message Instructions419
    21. Modbus RTU Instructions (DL260)427
    22. ASCII Instructions (DL260)433
    23. Intelligent Box (IBox) Instructions (DL250-1/DL260 Only)452

From the PDF’s own bookmarks.

The whole text · 61 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 41-4
  2. Pages 5 to 125-12
  3. Pages 13 to 2013-20
  4. Pages 21 to 2821-28
  5. Chapter 1: Getting Started29-42
  6. Chapter 2: Installation, Wiring and Specifications, pages 43 to 5143-51
  7. Chapter 2: Installation, Wiring and Specifications, pages 52 to 6052-60
  8. Chapter 2: Installation, Wiring and Specifications, pages 61 to 6961-69
  9. Chapter 2: Installation, Wiring and Specifications, pages 70 to 7870-78
  10. Chapter 2: Installation, Wiring and Specifications, pages 79 to 8779-87
  11. Chapter 2: Installation, Wiring and Specifications, pages 88 to 9488-94
  12. Chapter 3: CPU Specifications and Operations, pages 95 to 10495-104
  13. Chapter 3: CPU Specifications and Operations, pages 105 to 114105-114
  14. Chapter 3: CPU Specifications and Operations, pages 115 to 124115-124
  15. Chapter 3: CPU Specifications and Operations, pages 125 to 134125-134
  16. Chapter 3: CPU Specifications and Operations, pages 135 to 144135-144
  17. Chapter 3: CPU Specifications and Operations, pages 145 to 154145-154
  18. Chapter 3: CPU Specifications and Operations, pages 155 to 164155-164
  19. Chapter 4: System Design and Configuration, pages 165 to 174165-174
  20. Chapter 4: System Design and Configuration, pages 175 to 184175-184
  21. Chapter 4: System Design and Configuration, pages 185 to 194185-194
  22. Chapter 4: System Design and Configuration, pages 195 to 204195-204
  23. Chapter 4: System Design and Configuration, pages 205 to 214205-214
  24. Chapter 4: System Design and Configuration, pages 215 to 222215-222
  25. Chapter 5: RLL and Intelligent Box Instructions, pages 223 to 232223-232
  26. Chapter 5: RLL and Intelligent Box Instructions, pages 233 to 242233-242
  27. Chapter 5: RLL and Intelligent Box Instructions, pages 243 to 252243-252
  28. Chapter 5: RLL and Intelligent Box Instructions, pages 253 to 262253-262
  29. Chapter 5: RLL and Intelligent Box Instructions, pages 263 to 272263-272
  30. Chapter 5: RLL and Intelligent Box Instructions, pages 273 to 282273-282
  31. Chapter 5: RLL and Intelligent Box Instructions, pages 283 to 292283-292
  32. Chapter 5: RLL and Intelligent Box Instructions, pages 293 to 302293-302
  33. Chapter 5: RLL and Intelligent Box Instructions, pages 303 to 312303-312
  34. Chapter 5: RLL and Intelligent Box Instructions, pages 313 to 322313-322
  35. Chapter 5: RLL and Intelligent Box Instructions, pages 323 to 332323-332
  36. Chapter 5: RLL and Intelligent Box Instructions, pages 333 to 342333-342
  37. Chapter 5: RLL and Intelligent Box Instructions, pages 343 to 352343-352
  38. Chapter 5: RLL and Intelligent Box Instructions, pages 353 to 362353-362
  39. Chapter 5: RLL and Intelligent Box Instructions, pages 363 to 372363-372
  40. Chapter 5: RLL and Intelligent Box Instructions, pages 373 to 382373-382
  41. Chapter 5: RLL and Intelligent Box Instructions, pages 383 to 392383-392
  42. Chapter 5: RLL and Intelligent Box Instructions, pages 393 to 402393-402
  43. Chapter 5: RLL and Intelligent Box Instructions, pages 403 to 412403-412
  44. Chapter 5: RLL and Intelligent Box Instructions, pages 413 to 422413-422
  45. Chapter 5: RLL and Intelligent Box Instructions, pages 423 to 432423-432
  46. Chapter 5: RLL and Intelligent Box Instructions, pages 433 to 442433-442
  47. Chapter 5: RLL and Intelligent Box Instructions, pages 443 to 452443-452
  48. Chapter 5: RLL and Intelligent Box Instructions, pages 453 to 462453-462
  49. Chapter 5: RLL and Intelligent Box Instructions, pages 463 to 472463-472
  50. Chapter 5: RLL and Intelligent Box Instructions, pages 473 to 482473-482
  51. Chapter 5: RLL and Intelligent Box Instructions, pages 483 to 492483-492
  52. Chapter 5: RLL and Intelligent Box Instructions, pages 493 to 502493-502
  53. Chapter 5: RLL and Intelligent Box Instructions, pages 503 to 512503-512
  54. Chapter 5: RLL and Intelligent Box Instructions, pages 513 to 522513-522
  55. Chapter 5: RLL and Intelligent Box Instructions, pages 523 to 532523-532
  56. Chapter 5: RLL and Intelligent Box Instructions, pages 533 to 542533-542
  57. Chapter 5: RLL and Intelligent Box Instructions, pages 543 to 552543-552
  58. Chapter 5: RLL and Intelligent Box Instructions, pages 553 to 562553-562
  59. Chapter 5: RLL and Intelligent Box Instructions, pages 563 to 572563-572
  60. Chapter 5: RLL and Intelligent Box Instructions, pages 573 to 582573-582
  61. Chapter 5: RLL and Intelligent Box Instructions, pages 583 to 592583-592

The file

Revision and size

Part no.D2-USER-M
Revision4th Edition, Rev. A, 4/10
PublisherAutomationDirect
Pages592
PDF13 MB
TextText from the PDF itself; page 1 is a scan, read by OCR, which may hold reading errors.
D2-USER-M

The first pages · 3 of 592

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 592
Page 2
Page 2of 592
Page 3
Page 3of 592

More documents · 1

For the same models