Chapter 5: Standard RLL Instructions - Logical
Logical Instructions (Accumulator)
1 And (AND) The And instruction is a 16-bit instruction that logically ANDs 2 the value in the lower 16 bits of the accumulator with a specified V-memory location (Aaaa). The result resides in the 3 accumulator. The discrete status flag indicates if the result of the
And is zero. 4 Operand Data Type DL230 Range DL240 Range DL250-1 Range DL260 Range A aaa aaa aaa aaa 5 6 Discrete Bit Flags Description 7 8 NOTE: The status flags are only valid until another instruction that uses the same flags is executed. In the following example, when X1 is on, the value in V2000 will be loaded into the accumulator using the Load instruction. The value in the accumulator is anded with the value 9 in V2006 using the And instruction. The value in the lower 16 bits of the accumulator is output to V2010 using the Out instruction. 10 11 12 13 14 A B C D 230
AND
240
A aaa
250-1 260
V-memory
V
All. See memory map
Pointer
P
-
SP63
All. See memory map All V-memory. See memory map
All. See All. See memory map memory map All V-memory. All V-memory. See memory map See memory map on when the result of the instruction causes the value in the accumulator to be zero.
DS Used HPP Used DirectSOFT X1
V2000
LD
V2000
Load the value in V2000 into the lower 16 bits of the accumulator
2
8
? 7
A
The upper 16 bits of the accumulator will be set to 0
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7
6 5
Acc.
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
1
0
0
0
0
1
4 3
1 1
2
1
0
1
0
1
0
AND
V2006
AND the value in the accumulator with the value in V2006
Acc.
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
1
0
0
0
0
1 1
1
1
0
1
0
6A38 AND (V2006)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1 1
0
1
0
1
0
0
0
1
1
1
0
0
0
Acc.
0
0
0
0
0
0 1
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
1 1
1
0
0
0
2
8
3
8
1
OUT
V2010
Copy the lower 16 bits of the accumulator to V2010
V2010
Handheld Programmer Keystrokes $
B
1
STR
SHFT
V AND
GX OUT
L ANDST
ENT
D
C
A
2
3
SHFT
V AND
C
SHFT
V AND
C
A
0
A
2
0
A 2
A
0
A
0
B 0
0
G
6
A 1
0
ENT ENT ENT
DL205 User Manual, 4th Edition, Rev. A
5–71
Page 294
Chapter 5: Standard RLL Instructions - Logical
1
2
3 4 5 6 7 8 9 10 11 12 13 14 A B C D
And Double (ANDD) 230 240 250-1 260
DS Used HPP Used
The And Double is a 32-bit instruction that logically ANDs the value in the accumulator with two consecutive V-memory locations or an 8-digit (max.) constant value (Aaaa). The result resides in the accumulator. Discrete status flags indicate if the result of the And Double is zero or a negative number (the most significant bit is on). Operand Data Type
DL230 Range
ANDD A aaa
DL240 Range DL250-1 Range DL260 Range
A aaa aaa aaa aaa
V-memory
V
-
-
Pointer
P
-
-
Constant
K
0-FFFFFFFF
0-FFFFFFFF
All. See memory map All V-memory. See memory map 0-FFFFFFFF
All. See memory map All V-memory. See memory map 0-FFFFFFFF
Discrete Bit Flags
Description
SP63 SP70
Will be on if the result in the accumulator is zero Will be on if the result in the accumulator is negative
NOTE: The status flags are only valid until another instruction that uses the same flags is executed.
In the following example, when X1 is on, the value in V2000 and V2001 will be loaded into the accumulator using the Load Double instruction. The value in the accumulator is anded with 36476A38 using the And Double instruction. The value in the accumulator is output to V2010 and V2011 using the Out Double instruction.
DirectSOFT
V2000
X1
5
LDD
4
7
V2000 E
2
8
7
A
V2000 Load the value in V2000 and V2001 into the accumulator
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7
6 5
Acc.
0
1
0
1
0
1
0
0
0
1
1
1
1 1
1
0
0
0
1
0
1
0
0
0
0
1
Acc.
0
1
0
1
0
1
0
0
0
1
1
1
1 1
1
0
0
0
1
0
1
0
0
0
0
1 1
AND 36476A38
0
0
1 1
0
1 1
0
0
1
0
0
0
1
1 1
0
1
1
0
1
0
1
0
0
0
Acc.
0
0
0
0
1
0
0
1 0
0
0
0
1 0
1 0
0
0
1
0
1
0
0
0
0
0
1 1
4
4
6
2
8
3
8
4 3
2
1
0
1
0
1
0
1
1
0
1
0
1 1
1
0
0
0
1
0
0
0
1 1
ANDD K36476A38 AND the value in the accumulator with the constant value 36476A38
1 0
0
0
OUTD V2010
1
V2011
Copy the value in the accumulator to V2010 and V2011
V2010
Handheld Programmer Keystrokes $
B STR
1
SHFT
L ANDST
D
V AND
SHFT
D
SHFT
D
GX OUT
5–72
ENT D
3 3 3
C
A
SHFT
K JMP
D
C
A
B
2
0
A 0
2
3
A 0
G 3
6 A
1
0 E
0
ENT H
4
G 7
ENT
DL205 User Manual, 4th Edition, Rev. A
6
SHFT
A 0
SHFT
D
I 3
8
ENT
Page 295
Chapter 5: Standard RLL Instructions - Logical
And Formatted (ANDF) And Formatted instruction logically ANDs the binary value in 230 The the accumulator and a specified range of discrete memory bits (1 to 240
32). The instruction requires a starting location (Aaaa) and number 250-1 of bits (Kbbb) to be ANDed. Discrete status flags indicate if the 260 result is zero or a negative number (the most significant bit =1). Operand Data Type DS Used HPP Used
Inputs Outputs Control Relays Stage bits Timer bits Counter bits Special Relays Global I/O Constant
ANDF A aaa K bbb
DL250-1 Range
DL260 Range
A aaa bbb aaa bbb
X Y C S T CT SP GX/GY K
0–777 0–777 0–1777 0–1777 0–377 0–177 0-777 -
– – – – – – – – 1–32
0–1777 0–1777 0–3777 0–1777 0–377 0–377 0–777 0-3777 -
– – – – – – – – 1–32
Discrete Bit Flags
Description
SP63 SP70
Will be on if the result in the accumulator is zero Will be on if the result in the accumulator is negative
NOTE: Status flags are valid only until another instruction uses the same flag.
In the following example, when X1 is on the Load Formatted instruction loads C10–C13 (4 binary bits) into the accumulator. The accumulator contents is logically ANDed with the bit pattern from Y20–Y23 using the And Formatted instruction. The Out Formatted instruction outputs the accumulator’s lower four bits to C20–C23. DirectSOFT X1
C10
LDF K4
Load the status of 4 consecutive bits (C10-C13) into the accumulator ANDF
Location
Constant
C10
K4
C13 C12 C11 C10 ON ON ON OFF
The unused accumulator bits are set to zero 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7 6 5
4 3
2
1
0
0
0
0 0
0
0
1 1
0
Y20 K4
0
0
0 0
0
0
0
0
0 0
0 0
0
0
0
0
0
0 0
0 0
0
0
0
0
0
0
Acc.
0
0
0 0
0
0
0 0
0
0
0
0 0
0
0
0
0 1
1
1
0
1
0
0
0
0 0
0
0
0
0 0
0
0
0
0 1
0
0
0
Accumulator
And the binary bit pattern (Y20-Y23) with the value in the accumulator
0
Acc.
0 0
0
0
0
0
Y23 Y22 Y21 Y20 ON OFF OFF OFF
AND (Y20-Y23) C20
OUTF
1
K4 Copy the value in the lower 4 bits in accumulator to C20-C23
Location
Handheld Programmer Keystrokes $
B STR
1
SHFT
L ANDST
D
V AND
SHFT
F
GX OUT
SHFT
F
C20
5 5
C23 C22 C21 C20
K4
ON OFF OFF OFF
ENT F
3
Constant
NEXT
NEXT
NEXT
C
A
PREV
PREV
5
2
NEXT
A 2
B
E
ENT
4
0 C
NEXT
A 1
E 0
4
E 0
4
ENT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D
ENT
DL205 User Manual, 4th Edition, Rev. A
5–73
Page 296
Chapter 5: Standard RLL Instructions - Logical
1 2
3 4 5 6 7 8 9 10 11 12 13 14 A B C D
And with Stack (ANDS) 230 240 250-1 260
DS Used HPP Used
The And with Stack instruction is a 32-bit instruction that logically ANDs the value in the accumulator with the first level of the accumulator stack. The result resides in the accumulator. The value in the first level of the accumulator stack is removed from the stack and all values are moved up one level. Discrete status flags indicate if the result of the And with Stack is zero or a negative number (the most significant bit is on). Discrete Bit Flags Description SP63 SP70
ANDS
Will be on if the result in the accumulator is zero Will be on if the result in the accumulator is negative
NOTE: Status flags are valid only until another instruction uses the same flag.
In the following example, when X1 is on, the binary value in the accumulator will be anded with the binary value in the first level of the accumulator stack. The result resides in the accumulator. The 32 bit value is then output to V1500 and V1501.
DirectSOFT X1
V1401
LDD 5
V1400
E
2
V1400 8 7
A
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8 7
6 5
4 3
2
1
0
Acc.
0
1
0 1
0
1
0
0 0
1
1
1
1 1
1
0
0
0
1 0
1
0
0
0 0
1
1
1
1 0
1
0
Acc.
0
1
0 1
0
1
0
0 0
1
1
1
1 1
1
0
0
0
1 0
1
0
0
0 0
1
1
1
1 0
1
0
(top of stack)
0
0
1
0 1
1
0
1 0
0
0
1 1
0
1
1
1 0
1
0
0 1
1
1
0
0 0
Acc.
0
0
0 0 1
0
0
0 0
1 0
0
0 0 1
1 0
0
0
1 0
1
0
0 0
0
1
1 0
0 0
4
6
8
8
ANDS
AND the value in the accumulator with the first level of the accumulator stack
36476A38 AND
1
1
0
0
1
0
0
0
0
OUTD V1500 1
Copy the value in the accumulator to V1500 and 1501
$
B
STR
1 D
D 3
3
V AND
SHFT
S RST
ENT
GX OUT
SHFT
D
B
E
F 1
A 4
1
B 3
4
V1501
ENT
L ANDST
5–74
7
Load the value in V1400 and 1401 into the accumulator
Handheld Programmer Keystrokes
SHFT
4
A 5
A 0
A 0
0
0
ENT
ENT
DL205 User Manual, 4th Edition, Rev. A
2
3
V1500
1
Page 297
Chapter 5: Standard RLL Instructions - Logical
Or (OR)
230 240 250-1 260
The Or instruction is a 16-bit instruction that logically ORs the value in the lower 16 bits of the accumulator with a specified V-memory location (Aaaa). The result resides in the accumulator. The discrete status flag indicates if the result of the Or is zero.
DS Used HPP Used
Operand Data Type
OR A aaa
DL230 Range DL240 Range DL250-1 Range DL260 Range A aaa aaa aaa aaa
V-memory
V
All See memory map
Pointer
P
-
All See memory map All V-memory. See memory map
All See memory map All V-memory. See memory map
All See memory map All V-memory. See memory map
Discrete Bit Flags
Description
SP63
Will be on if the result in the accumulator is zero
NOTE: The status flags are only valid until another instruction that uses the same flags is executed.
In the following example, when X1 is on, the value in V2000 will be loaded into the accumulator using the Load instruction. The value in the accumulator is ored with V2006 using the Or instruction. The value in the lower 16 bits of the accumulator are output to V2010 using the Out instruction. DirectSOFT X1
V2000
LD 2
V2000
8
7
A
The upper 16 bits of the accumulator will be set to 0
Load the value in V2000 into the lower 16 bits of the accumulator
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7
6 5
2
1
0
Acc.
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
1
0
0
0
0
1
1 1
1
0
1
0
V2006
Acc.
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
1
0
0
0
0
1
1 1
1
0
1
0
Or the value in the accumulator with the value in V2006
6A38 OR (V2006)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
0
1
0
1
0
0
0
1 1
1
0
0
0
Acc.
0
0
0
0
0
0 1
0
0
0
0
0
0
0
0
0
0
0
1
1
0
1
0
1
0
0
1
1 1
1
0
1
0
6
A
7
A
4 3
OR
OUT V2010 Copy the value in the lower 16 bits of the accumulator to V2010
V2010
Handheld Programmer Keystrokes $
B STR
SHFT Q OR GX OUT
1 L ANDST
ENT
D
C 3
A 2
SHFT
V AND
C
SHFT
V AND
C
A 0
A 2
A 0
A 2
A 0
6
0 B
0
0 G A
1
0
ENT ENT ENT
DL205 User Manual, 4th Edition, Rev. A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D
5–75
Page 298
Chapter 5: Standard RLL Instructions - Logical
1 2
3 4 5 6 7 8 9 10 11 12 13 14 A B C D
Or Double (ORD) 230 240 250-1 260
The Or Double is a 32-bit instruction that ORs the value in the accumulator with the value (Aaaa) or an 8-digit (max.) constant value. The result resides in the accumulator. Discrete status flags indicate if the result of the Or Double is zero or a negative number (the most significant bit is on). Operand Data Type
DS Used HPP Used
DL230 Range
ORD A aaa
DL240 Range DL250-1 Range DL260 Range
A aaa aaa aaa aaa
V-memory
V
-
-
Pointer
P
-
-
Constant
K
0-FFFFFFFF
0-FFFFFFFF
All. See memory map All V-memory. See memory map 0-FFFFFFFF
All. See memory map All V-memory. See memory map 0-FFFFFFFF
Discrete Bit Flags
Description
SP63 SP70
Will be on if the result in the accumulator is zero Will be on if the result in the accumulator is negative
NOTE: The status flags are only valid until another instruction that uses the same flags is executed.
In the following example, when X1 is on, the value in V2000 and V2001 will be loaded into the accumulator using the Load Double instruction. The value in the accumulator is ored with 36476A38 using the Or Double instruction. The value in the accumulator is output to V2010 and V2011 using the Out Double instruction.
DirectSOFT X1
V2001
LDD 5
V2000
4
7
V2000 E
2
8
7
A
Load the value in V2000 and V2001 into accumulator 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7
6 5
Acc.
0
1
0
1
0
1
0
0
0
1
1
1
1 1
1
0
0
0
1
0
1
0
0
0
0
1
Acc.
0
1
0
1
0
1
0
0
0
1
1
1
1 1
1
0
0
0
1
0
1
0
0
0
0
1 1
OR 36476A38
0
0
1
1
0
1
1
0
0
1
0
0
0
1 1
1
0
1 1
0
1
0
1
0
0
Acc.
0
0 1
0 1 10
0
1 10
0
0
0 1
0 1
1 0
1 0 10
1 0 10
0
1
0
1
0
1
0
0
6
7
F
6
A
7
A
K36476A38 OR the value in the accumulator with the constant value 36476A38
GX OUT
5–76
0
1
0
1
1
0
1
0
1
0
1 1
1
0
0
0
1
1 1
1
0
1
0
V2010 7
Copy the value in the accumulator to V2010 and V2011
B
STR
OR
1
0
OUTD
$
Q
2
1
ORD
V2011
V2010
Handheld Programmer Keystrokes
SHFT
4 3
1 1
1 L ANDST
D
SHFT
D
SHFT
D
ENT D
3 3 3
C
A
SHFT
K JMP
D
C
A
B
2
0
A 0
2
3
A 0
G 3
6 A
1
0 E
0
ENT H
4
G 7
ENT
DL205 User Manual, 4th Edition, Rev. A
6
SHFT
A 0
SHFT
D
I 3
8
ENT
Page 299
Chapter 5: Standard RLL Instructions - Logical
Or Formatted (ORF)
1 K bbb 2 3 Operand Data Type DL250-1 Range DL260 Range A aaa bbb aaa bbb 4 5 6 7 8 Discrete Bit Flags Description 9 10 NOTE: Status flags are valid only until another instruction uses the same flag. In the following example, when X1 is on the Load Formatted instruction loads C10–C13 11 (4 binary bits) into the accumulator. The Or Formatted instruction logically ORs the accumulator contents with Y20–Y23 bit pattern. The Out Formatted instruction outputs the accumulator’s lower four bits to C20–C23. 12 13 14 A B C D The Or Formatted instruction logically ORs the binary value in the accumulator and a specified range of discrete bits (1 to 32). The instruction requires a starting location (Aaaa) and the number of bits (Kbbb) to be ORed. Discrete status flags indicate if the result is zero or negative (the most significant bit =1).
230 240 250-1 260 DS Used HPP Used
Inputs Outputs Control Relays Stage bits Timer bits Counter bits Special Relays Global I/O Constant
X Y C S T CT SP GX/GY K
SP63 SP70
0–777 0–777 0–1777 0–1777 0–377 0–177 0-777 -
– – – – – – – – 1–32
A aaa
0–1777 0–1777 0–3777 0–1777 0–377 0–377 0–777 0-3777 -
– – – – – – – – 1–32
Will be on if the result in the accumulator is zero Will be on if the result in the accumulator is negative
DirectSOFT X1
ORF
LDF
C10
Location
Constant
C13 C12 C11 C10
C10
K4
OFF ON ON OFF
K4
The unused accumulator bits are set to zero
Load the status of 4 consecutive bits (C10-C13) into the accumulator ORF
Acc.
Y20
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7 6 5
4 3
2
1
0
0
0
0 0
0
0
1 1
0
1
0
0
0
0
0
0 1
1
1
0
0
0
0 0
0
0
0
0 0
0
0
0
0 0
0
0
0
0
0
0
0 0
0
0
0
0 0
0
0
0 0
0 0
0
0
0
0
0 0
0
K4
OR the binary bit pattern (Y20 - Y23) with the value in the accumulator OUTF
Y23 Y22 Y21 Y20
ON OFF OFF OFF
OR (Y20- Y23)
Acc.
C20
0
0
0
0 0
0
0
0
K4
Copy the specified number of bits from the accumulator to C20-C23
Handheld Programmer Keystrokes $
B
STR
1
SHFT
L ANDST
D
Q
SHFT
F
SHFT
F
OR GX OUT
5 5
Constant
C23 C22 C21 C20
C20
K4
ON ON ON OFF
ENT
F
3
Location
NEXT
NEXT
NEXT
C
A
PREV
PREV
5
NEXT
C
A 2
B
E
ENT
4
0
2
NEXT
A
1
E 0
4
E
0
4
ENT
ENT
DL205 User Manual, 4th Edition, Rev. A
5–77
Page 300
Chapter 5: Standard RLL Instructions - Logical
1 2
3 4 5 6 7 8 9 10 11 12 13 14 A B C D
Or with Stack (ORS) 230 240 250-1 260
DS Used HPP Used
The Or with Stack instruction is a 32-bit instruction that logically ORs the value in the accumulator with the first level of the accumulator stack. The result resides in the accumulator. The value in the first level of the accumulator stack is removed from the stack and all values are moved up one level. Discrete status flags indicate if the result of the Or with Stack is zero or a negative number (the most significant bit is on). Discrete Bit Flags
OR S
Description
SP63 SP70
Will be on if the result in the accumulator is zero Will be on if the result in the accumulator is negative
In the following example, when X1 is on, the binary value in the accumulator will be ORed with the binary value in the first level of the stack. The result resides in the accumulator.
DirectSOFT X1
V1400
V1401
LDD
5
V1400
4
7
E
2
8
7
A
Load the value in V1400 and V1401 in the accumulator
Acc.
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8 7
6 5
4 3
0
0 0
1
1
1
1
0 1
0
1
0
0 0
1
1
1
1 1
1
0
0
0
1 0
1
0
0
2
1
0
1 0
1
0
0
ORS
OR the value in the accumulator with the value in the first level of the accumulator stack
Acc.
0
1
0 1
0
1
0
0 0
1
1
1
1 1
1
0
0
0
1 0
1
0
0
0 0
1
1
1
1 0
1
36476A38 OR (top of stack)
0
0
1
0 1
1
0
1 0
0
0
1 1
0
1
1
1 0
1
0
0 1
1
1
0 0
0
1 0
1 0 0 1
0
1 0
0 0
1 0
1 0
1 0 0 1
1 0
0
1
1 0
1
1
0 0
1
1
1 0
6
F
A
A
Acc.
1
1
0
1 0
1
1 0
0
0
0
OUTD V1500 Copy the value in the accumulator to V1500 and V1501
7
Handheld Programmer Keystrokes
5–78
$
B 1
STR
ENT
SHFT
L ANDST
D 3
3
Q
SHFT
S RST
ENT
SHFT
D
OR GX OUT
D
B
E
F 1
A 4
1
B 3
7
V1501
A 5
A 0
A 0
0
0
ENT
ENT
DL205 User Manual, 4th Edition, Rev. A
6
7
V1500
1
0
1
0
Page 301
Chapter 5: Standard RLL Instructions - Logical
Exclusive Or (XOR)
230 240 250-1 260 DS Used HPP Used
1 2 3 Operand Data Type DL230 Range DL240 Range DL250-1 Range DL260 Range A aaa aaa aaa aaa 4 5 Discrete Bit Flags Description 6 7 NOTE: The status flags are only valid until another instruction that uses the same flags is executed. 8 In the following example, when X1 is on, the value in V2000 will be loaded into the accumulator using the Load instruction. The value in the accumulator is exclusive ORed with V2006 using the Exclusive Or instruction. The value in the lower 16 bits of the accumulator 9 are output to V2010 using the Out instruction. 10 11 12 13 14 A B C D The Exclusive Or instruction is a 16-bit instruction that performs an exclusive OR of the value in the lower 16 bits of the accumulator and a specified V-memory location (Aaaa). The result resides in the accumulator. The discrete status flag indicates if the result of the XOR is zero.
V-memory
V
All See memory map
Pointer
P
-
SP63 SP70
DirectSOFT X1
All See memory map All V-memory. See memory map
XOR
A aaa
All See memory map All V-memory. See memory map
All See memory map All V-memory. See memory map
Will be on if the result in the accumulator is zero Will be on if the result in the accumulator is negative
V2000
LD
2
V2000
8
7
A
The upper 16 bits of the accumulator will be set to 0
Load the value in V2000 into the lower 16 bits of the accumulator
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Acc. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0 0 1 0 0 1
0 0 0 1 1 1
1 0 1 0
XOR
V2006
XOR the value in the accumulator with the value in V2006
Acc.
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0 0 1 0 0 1 0 0 0 1 1 1
1 0 1 0
6A38 XOR (V2006)
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0 1 1
1 0 0 0
0 0 0 0 0 0 0 0 0 0 0 Acc. 0 0 0 0 0 1
0 1 0 1 0 0 0 1 1
0 1 0 0 1 1 1 0 0 1 0 0 0 0 1 0
OUT
V2010
4
Copy the lower 16 bits of the accumulator to V2010
E
4
2
V2010
Handheld Programmer Keystrokes $
B
STR
1
SHFT
L D 3 ANDST
SHFT
X SET
GX OUT
ENT
SHFT
SHFT
Q
SHFT
V AND
OR
C 2
V AND
C
SHFT
V AND
C
A
B
A
0
A
2
1
A
0
A
0
A
2 0
0
A
0
ENT
G
0
6
ENT
ENT
DL205 User Manual, 4th Edition, Rev. A
5–79
Page 302
Chapter 5: Standard RLL Instructions - Logical
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D
Exclusive Or Double (XORD) Exclusive Or Double is a 32-bit instruction that 230 The performs an exclusive OR of the value in the 240 accumulator and the value (Kaaa), which is an 250-1 8-digit (max.) constant. The result resides in the 260 accumulator. Discrete status flags indicate if the DS Used HPP Used
XORD K aaa result of the Exclusive Or Double is zero or a negative number (the most significant bit is on). Operand Data Type Constant
DL230 Range K
DL240 Range DL250-1 Range DL260 Range aaa aaa aaa aaa
0-FFFFFFFF
0-FFFFFFFF
0-FFFFFFFF
0-FFFFFFFF
NOTE: The status flags are only valid until another instruction that uses the same flags is executed.
In the following example, when X1 is on, the value in V2000 and V2001 will be loaded into Discrete Bit Flags
Description
SP63 SP70
Will be on if the result in the accumulator is zero Will be on if the result in the accumulator is negative the accumulator using the Load Double instruction. The value in the accumulator is exclusively ORed with 36476A38 using the Exclusive Or Double instruction. The value in the accumulator is output to V2010 and V2011 using the Out Double instruction.
DirectSOFT
V2001
X1
5
LDD
4 ?
7
V2000 E
2
8
7
A
V2000 Load the value in V2000 and V2001 into the accumulator
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7
6 5
Acc.
0
1
0
1
0
1
0
0
0
1
1
1
1 1
1
0
0
0
1
0
1
0
0
0
0
1
Acc.
0
1
0
1
0
1
0
0
0
1
1
1
1 1
1
0
0
0
1
0
1
0
0
0
0
1 1
XORD 36476A38
0
0
1
1
0
1
1
0
0
1
0
0
0
1 1
1
0
1 1
0
1
0
1
0
0
Acc.
0
1 0
1 0
0
0
0 1
1 0
0
0
0
1 0
1 0
1 0
0
1 0
0
1
0
0
0
1
0
0
2
3
9
4
2
4
2
XORD
4 3
2
1
0
1
0
1
0
1
1
0
1
0
0
1 1
1
0
0
0
1
0
0
0
1
0
1 1
K36476A38 XORD the value in the accumulator with the constant value 36476A38 OUTD
0
0
V2010 Copy the value in the accumulator to V2010 and V2011
6
V2011
Handheld Programmer Keystrokes $
B 1
STR SHFT
L ANDST
D
SHFT
X SET
Q
D
G
E
3 GX OUT
5–80
3 OR
6 SHFT
ENT D
4 D
C
SHFT
D
H
G 6 2
A
SHFT
K JMP
SHFT
A
SHFT
D
A
B
A
ENT
3
7
A 0
2
C 3
A 0
3
0
0 1
0
ENT
0
I 3
8
DL205 User Manual, 4th Edition, Rev. A
ENT
V2010
0