Chapter 5: Standard RLL Instructions - Program Control In the following example, when X1 is on, the application program inside the For/Next loop will be executed three times. If X1 is off the program inside the loop will not be executed. The immediate instructions may or may not be necessary depending on your application. Also, The RSTWT instruction is not necessary if the For/Next loop does not extend the scan time larger the Watch Dog Timer setting. For more information on the Watch Dog Timer, refer to the RSTWT instruction. DirectSOFT X1

1

K3

2

3

FOR

RSTWT

X20

Y5 OUT

NEXT

Handheld Programmer Keystrokes $

B 1

STR SHFT

F 5

O INST#

SHFT

R ORN

S RST

SHFT

I

$ STR GX OUT SHFT

T MLR

8 F 5

N TMR

ENT R ORN

E 4

D 3

ENT

W ANDN

T MLR

ENT

C

A

ENT

2

0

T MLR

ENT

ENT X SET

DL205 User Manual, 4th Edition, Rev. A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D

5–181

Page 404

Chapter 5: Standard RLL Instructions - Program Control

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D

Goto Subroutine (GTS) (SBR) Goto Subroutine instruction allows a section of 230 The ladder logic to be placed outside the main body of the 240 program and execute only when needed. There can be a 250-1 maximum of 128 GTS instructions and 64 SBR 260 instructions used in a program. The GTS instructions DS Used HPP Used can be nested up to 8 levels. An error E412 will occur if the maximum limits are exceeded. Typically this will be used in an application where a block of program logic may be slow to execute and is not required to execute every scan. The subroutine label and all associated logic is placed after the End statement in the program. When the subroutine is called from the main program, the CPU will execute the subroutine (SBR) with the same constant number (K) as the GTS instruction which called the subroutine. By placing code in a subroutine it is only scanned and executed when needed since it resides after the End instruction. Code which is not scanned does not impact the overall scan time of the program. Operand Data Type Constant

K

K aaa GTS

K aaa

SBR

DL240 Range

DL250-1 Range aaa aaa

DL260 Range aaa

1-FFFF

1-FFFF

1-FFFF

Subroutine Return (RT) When a Subroutine Return is executed in the subroutine,

CPU will return to the point in the main body of the 240 the program from which it was called. The Subroutine 250-1 Return is used as termination of the subroutine, which 260 must be the last instruction in the subroutine and is a 230

RT stand alone instruction (no input contact on the rung).

Subroutine Return Conditional (RTC) Subroutine Return Conditional instruction is a 230 The optional instruction used with an input contact to 240 implement a conditional return from the subroutine. The 250-1 Subroutine Return (RT) is still required for termination 260 of the Subroutine. DS Used HPP Used

5–182

DL205 User Manual, 4th Edition, Rev. A

RTC

Page 405

Chapter 5: Standard RLL Instructions - Program Control In the following example, when X1 is on, Subroutine K3 will be called. The CPU will jump to the Subroutine Label K3 and the ladder logic in the subroutine will be executed. If X35 is on the CPU will return to the main program at the RTC instruction. If X35 is not on, Y0–Y17 will be reset to off and then the CPU will return to the main body of the program.

DirectSOFT

X1

K3 GTS

C0 LD K10

END

SBR

K3

X20

Y5 OUTI

X21

Y10 OUTI

X35 RTC

X35

Y0

Y17 RSTI

RT

Handheld Programmer Keystrokes STR SHFT

G

1

ENT

T

S

K

3

ENT

E

N

D

ENT

SHFT

S

SHFT

B

R

1 K

3

STR

SHFT

I

X

2

0

ENT

OUT

SHFT

I

Y

5

ENT

STR

SHFT

I

X

2

1

ENT

OUT

SHFT

I

Y

1

0

ENT

STR

SHFT

I

X

3

5

ENT

SHFT

R

T

STRN

SHFT

I

X

3

5

ENT

RST

SHFT

I

Y

0

Y

1

SHFT

R

T

ENT

Standard RLL Instructions

SHFT

ENT

C

7

ENT

ENT

DL205 User Manual, 4th Edition, Rev. A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D

5–183

Page 406

Chapter 5: Standard RLL Instructions - Program Control

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D

In the following example, when X1 is on, Subroutine K3 will be called. The CPU will jump to the Subroutine Label K3 and the ladder logic in the subroutine will be executed. The CPU will return to the main body of the program after the RT instruction is executed. Direct SOFT X1

END

SBR

K3

X20

Y5 OUT

X21

Y10 OUT

RT

Handheld Programmer Keystrokes $

B STR

SHFT

1 G

ENT

6

T MLR

S RST

N TMR

D

4

B

D 3

ENT

SHFT

E

SHFT

S RST

SHFT

SHFT

I

$ STR GX OUT $ STR

D 3 A

2

0

ENT

ENT

I

C 8

B R ORN

1

ENT R ORN

8 5

SHFT

3

C

F

GX OUT SHFT

5–184

K3 GTS

B 2

A 1

0

T MLR

ENT

ENT

DL205 User Manual, 4th Edition, Rev. A

1

ENT

ENT

Page 407

Chapter 5: Standard RLL Instructions - Program Control

Master Line Set (MLS) The Master Line Set instruction allows the program to control

230 sections of ladder logic by forming a new power rail controlled by the 240 main left power rail. The main left rail is always master line 0. When 250-1 a MLS K1 instruction is used, a new power rail is created at level 1. power 260 Master Line Sets and Master Line Resets can be used to nestPLUS

K aaa MLS rails up to seven levels deep. Note that unlike stages in RLL , the logic within the master control relays is still scanned and updated even though it will not function if the MLS is off.

Operand Data Type Constant

K

DL230 Range

DL240 Range

DL250-1 Range

DL260 Range aaa aaa aaa aaa

1-7

1-7

1-7

1-7

Master Line Reset (MLR) The Master Line Reset instruction marks the end of control for the

230 corresponding MLS instruction. The MLR reference is one less than 240 the corresponding MLS. 250-1 260 Operand Data Type Constant

K

K aaa MLR

DL230 Range

DL240 Range

DL250-1 Range

DL260 Range aaa aaa aaa aaa

0-6

0-6

0-6

0-6

Understanding Master Control Relays The Master Line Set (MLS) and Master Line Reset (MLR) instructions allow you to quickly enable (or disable) sections of the RLL program. This provides program control flexibility. The following example shows how the MLS and MLR instructions operate by creating a sub power rail for control logic. DS Used HPP Used

DirectSOFT X0

K1 MLS

When contact X0 is ON, logic under the first MLS will be executed.

Y7

X1

OUT K2

X2

MLS

X3

When contact X0 and X2 are ON, logic under the second MLS will be executed.

Y10 OUT K1 MLR K0

The MLR instructions note the end of the Master Control area.

MLR X10

Y11

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D

OUT

DL205 User Manual, 4th Edition, Rev. A

5–185

Page 408

Chapter 5: Standard RLL Instructions - Program Control

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D

MLS/MLR Example In the following MLS/MLR example logic between the first MLS K1 (A) and MLR K0 (B) will function only if input X0 is on. The logic between the MLS K2 (C) and MLR K1 (D) will function only if input X10 and X0 is on. The last rung is not controlled by either of the MLS coils. DirectSOFT

Handheld Programmer Keystrokes

X0

K1

X1

X2

A

Y MLS

B

OUT

$

B STR

1

C1

GX OUT

SHFT

C

$

C

ENT

Y0

K2

C

Y1

Y2

D MLR

OUT X6

Y3

SHFT

C

$

D

ENT

MLR X7

Y4 OUT

A

$

B

0

C

$

F 5

GX OUT

B

$

E

1

B

4

GX OUT

C

T MLR

B

$

F

2 1

0

ENT ENT ENT ENT ENT

SHFT

C

$

G

ENT

GX OUT

D

T MLR

A

$

H

3 0 7 E 4

ENT

ENT

GX OUT

6

ENT

ENT

5

STR

1

ENT

ENT

STR

STR

DL205 User Manual, 4th Edition, Rev. A

B

A

2

0

2

1

Y MLS

GX OUT

5–186

3

GX OUT

OUT K0

A 2

GX OUT

STR

C2

ENT

2

STR

K1

ENT

STR

OUT

X5

1

STR

OUT X4

0

STR

MLS X5

ENT

C0

OUT X10

A STR

OUT X3

$

MLS

C 2

ENT ENT ENT ENT

2

ENT

Page 409

Chapter 5: Standard RLL Instructions - Interrupt

Interrupt Instructions

1 Interrupt (INT) The Interrupt instruction allows a section of ladder logic to 2 be placed outside the main body of the program and executed when needed. Interrupts can be called from the 3 program or by external interrupts via the counter interface module (D2–CTRINT), which provides 4 interrupts.

4 The software interrupt uses interrupt #00 which means the hardware interrupt #0 and the 5 software interrupt cannot be used together. Typically, interrupts will be used in an application where a fast response to an input is needed 6 or a program section needs to execute faster than the normal CPU scan. The interrupt label and all associated logic must be placed after the End statement in the program. When the interrupt routine is called from the interrupt module or software interrupt, the CPU will 7 complete execution of the instruction it is currently processing in ladder logic, then execute the designated interrupt routine. Interrupt module interrupts are labeled in octal to 8 correspond with the hardware input signal (X1 will initiate interrupt INT1). There is only one software interrupt and it is labeled INT 0. The program execution will continue from where it was before the interrupt occurred once the interrupt is serviced. 9 The software interrupt is setup by programming the interrupt time in V7634. The valid range is 3 to 999 ms. The value must be a BCD value. The interrupt will not execute if the value is 10 out of range. NOTE: See the example program of a software interrupt. 11 Operand Data Type DL240 Range DL250-1 Range DL260 Range 12 aaa aaa aaa 13 DL240/250-1/260 Software DL240/250-1/260 Hardware 14 Interrupt Input Interrupt Routine Interrupt Input Interrupt Routine A B C D 230

O aaa

INT

240

250-1 260

DS Used HPP Used

Constant

0

0-3

0-3

0-3

V7634 sets interrupt time

INT 0

INT 0

-

-

X0 (cannot be used along with s/w interrupt) X1 X2 X3

INT 1 INT 2 INT 3

DL205 User Manual, 4th Edition, Rev. A

5–187

Page 410

Chapter 5: Standard RLL Instructions - Interrupt

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D

Interrupt Return (IRT) When an Interrupt Return is executed in the interrupt routine, the

230 CPU will return to the point in the main body of the program from 240 which it was called. The Interrupt Return is programmed as the last 250-1 instruction in an interrupt routine and is a stand alone instruction 260 (no input contact on the rung).

IRT

Interrupt Return Conditional (IRTC)

The Interrupt Return Conditional instruction is a optional

230 instruction used with an input contact to implement a condtional 240 return from the interrupt routine. The Interrupt Return is required to 250-1 terminate the interrupt routine. 260 Enable Interrupts (ENI)

IRTC

The Enable Interrupt instruction is programmed in the main body of

230 the application program (before the End instruction) to enable 240 hardware or software interrupts. Once the coil has been energized, 250-1 interrupts will be enabled until they are disabled by the Disable 260 Interrupt instruction.

ENI

Disable Interrupts (DISI) The Disable Interrupt instruction is programmed in the main body of

230 the application program (before the End instruction) to disable both 240 hardware or software interrupts. Once the coil has been energized, 250-1 interrupts will be disabled until they are enabled by the Enable 260 Interrupt instruction.

5–188

DL205 User Manual, 4th Edition, Rev. A

DISI

DS Used HPP Used

Page 411

Chapter 5: Standard RLL Instructions - Interrupt

Interrupt Example for Interrupt Module In the following example, when X40 is on, the interrupts will be enabled. When X40 is off the interrupts will be disabled. When a interrupt signal X1 is received, the CPU will jump to the interrupt label INT O 1. The application ladder logic in the interrupt routine will be performed. The CPU will return to the main body of the program after the IRT instruction is executed. DirectSOFT

Handheld Programmer Keystrokes $

X40

E STR

ENI

SHFT

E 4

SP STRN X40 DISI

. . . END

O1

X20

Y5 SETI

X21

Y10

I

E

A 0

3

8

S RST

N TMR

D

4 8

N TMR

T MLR

SHFT

E

SHFT

I

$

SHFT

I

X SET

SHFT

I

$

SHFT

I

X SET

SHFT

I

SHFT

I

R ORN

STR

I

8

ENT

8

4 D

ENT

0

N TMR

SHFT

STR INT

A 4

3

ENT I 8

ENT

ENT B 1 C

8

A 2

F 8

5 C

8

0

B

B T MLR

1 A

1

ENT

ENT

2

8

ENT

0

ENT

SETI

IRT

DL205 User Manual, 4th Edition, Rev. A

ENT ENT

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D

5–189

Page 412

Chapter 5: Standard RLL Instructions - Interrupt

In the following example, when X1 is on, the value 10 is copied to V7634. This value sets the software interrupt to 10 ms. When X20 turns on, the interrupt will be enabled. When X20 turns off, the interrupt will be disabled. Every 10 ms the CPU will jump to the interrupt label INT O 0. The application ladder logic in the interrupt routine will be performed. If X35 is not on Y0–Y17 will be reset to off and then the CPU will return to the main body of the program. DirectSOFT

Handheld Programmer Keystrokes SP0

$

LD

SHFT

STR

K40

SHFT

L ANDST

SP STRN

D 3

A 0

ENT

SHFT

K JMP

B

H

G

D

A 4

0

ENT

OUT V7633

X1

GX OUT

SHFT

$

B

K104*

SHFT

Load the constant value (K10) into the lower 16 bits of the accumulator *

GX OUT $

L ANDST

SHFT

Copy the value in the lower 16 bits of the accumulator to V7634

4

SP STRN

ENI

X20

. . . END

INT

SHFT

K JMP

B

SHFT

G

D

C

A

ENT

O0

I

C

A 0

3

8

S RST D

4

N TMR

8

N TMR

T MLR

SHFT

E

SHFT

I

$

SHFT

I

X SET

SHFT

I

SP STRN

SHFT

I

S RST

SHFT

I

SHFT

I

R ORN

8

3

8

4

ENT

ENT

ENT

A 0

8

A 2

F 8

5 D

8

0

3

ENT ENT

ENT F

A

5

ENT B

0 T MLR

3

4

ENT

H 1

7

ENT

ENT

Y5 SETI

Y0

Y17 RSTI

5–190

6

E 0

E

ENT I

C

8

A 1

* The value entered, 3-999, must be followed by the digit 4 to complete the instruction.

X20

X35

3

ENT

ENT

8

2 I

7

0

N TMR

SHFT

STR DISI

3

H

D

X20

6

V AND

3

2 E

7

D

ENT

D

STR V7634

V

1

STR

LD

OUT ard RLL uctions

1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D

Interrupt Example for Software Interrupt

IRT

NOTE: Only one software interrupt is allowed and it must be Int0.

DL205 User Manual, 4th Edition, Rev. A