Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of Discrete Output Modules (DL305 User Manual, chapter 7)

Manual · Koyo

Discrete Output Modules (DL305 User Manual, chapter 7)

Manual22 pagesPDF 517 KB

Discrete output modules chapter of the DL305 User Manual: specification sheets for DL305/FL305 DC, AC and relay output modules.

What this file really is

The old site listed this file as a manual for the Koyo d3--05. This is only the discrete output modules chapter of the DL305 User Manual, not a full user manual for the D3-05, which it does not mention.

Download the PDF517 KB

Filed with · 1 model

Also filed with these models on the old site

Summary

What is in it

Chapter 7 of the DL305 User Manual, Rev. D: the I/O specification sheets for the DL305/FL305 discrete output modules. It explains module identification, color coding and the terms used in the specifications, gives an application note on relay arc suppression for the F3-08TRS relay modules, then one sheet per module (24 VDC, 110-220 VAC, isolated AC and relay output modules from D3-08TD1 to D3-16TR) with ratings, derating chart and wiring diagram.

Its parts

  1. Discrete Output Module Identification and Terminology
  2. Relay Arc Suppression - DC and AC Applications
  3. D3-08TD1, 24 VDC Output Module
  4. D3-08TD2, 24 VDC Output Module
  5. D3-16TD1-1, 24 VDC Output Module
  6. D3-16TD1-2, 24 VDC Output Module
  7. D3-16TD2, 24 VDC Output Module
  8. D3-04TAS, 110-220 VAC Output Module
  9. F3-08TAS, 250 VAC Isolated Output Module
  10. F3-08TAS-1, 125 VAC Isolated Output Module
  11. D3-08TA-1, 110-220 VAC Output Module
  12. D3-08TA-2, 110-220 VAC Output Module
  13. F3-16TA-2, 20-125 VAC Output Module
  14. D3-16TA-2, 110-220 VAC Output Module
  15. D3-08TR, Relay Output Module

From the manual

Key facts from this manual

Each line names its page in the PDF.

Chapter 7 of the Koyo DL305 User Manual, revision D: specification sheets for the DL305/FL305 discrete output modules, from the 24 VDC D3--08TD1 to D3--16TD2, through AC modules such as the D3--08TA--1 and F3--08TAS, to the relay modules D3--08TR, F3--08TRS--1, F3--08TRS--2 and D3--16TR. It explains the specification terms and relay arc suppression, then gives ratings, derating charts and wiring for each module. The D3--05 it is filed under is not named in this chapter.

Read for this summary: pages 1 to 21 of 22.

Contents
Spec sheets for 18 DL305/FL305 discrete output modules: 24 VDC transistor, AC triac or SSR, and relay types p. 1, 2
24 VDC modules
D3--08TD1, D3--08TD2, D3--16TD1--1, D3--16TD1--2, D3--16TD2 p. 1
AC modules
110--220 VAC: D3--04TAS, D3--08TA--1, D3--08TA--2, D3--16TA--2; F3--08TAS (250 VAC isolated); F3--08TAS--1 (125 VAC isolated); F3--16TA--2 (20--125 VAC) p. 1
Relay modules
D3--08TR, F3--08TRS--1, F3--08TRS--2, D3--16TR p. 1
24 VDC outputs
0.5A per point; sinking: D3--08TD1, D3--16TD1--1, D3--16TD1--2; sourcing: D3--08TD2, D3--16TD2 p. 6, 7, 8, 9, 10
D3 relay ratings
D3--08TR: Form A, 4A/point AC, 5A/point DC, 6A/common; D3--16TR: 16 Form A, 2A/point, 8A/common p. 18, 21
F3 relay ratings
F3--08TRS--1: 10A/point, 30A/module; F3--08TRS--2: 5A/point, 40A/module; both 6 Form A and 2 Form C p. 19, 20
Motor starters
F3--08TRS--1: up to NEMA size 4; F3--08TRS--2 and F3--16TA--2: up to NEMA size 3 p. 16, 19, 20
F3 relay DC limit
F3--08TRS--1 and F3--08TRS--2: 120 VDC at 0.5 A maximum, 30,000 cycles typical p. 19, 20
Isolation
F3--08TAS: 500V point-to-point; F3--08TAS--1: 1500V point-to-point p. 12, 13
Fuses
F3--08TAS--1 and F3--16TA--2: 5A 125V fast blow, order D3--FUSE--4 (5 per pack); F3--08TAS: BK/PCE--5 Bussman, one spare included p. 12, 13, 16
SSR output types
F3--08TAS and F3--16TA--2: SSR array (triac); F3--08TAS--1: SSR (triac with zero cross-over) p. 12, 13, 16
Relay life
F3--08TRS--2: expected mechanical life 100 million operations p. 20
Color code
Output modules have a red color bar below the part number p. 2

What this manual walks you through

  • Identifying output modules by status indicators and color bar p. 2
  • What each output specification term means p. 2, 3
  • Choosing a transistor, triac or relay output p. 3
  • Adding RC contact protection to the F3--08TRS--1 and F3--08TRS--2 p. 4
  • Protecting relay contacts on DC inductive loads p. 4
  • Picking resistor and capacitor values with the nomogram p. 5
  • Ratings, derating charts and wiring diagrams for each module p. 6, 11, 18, 21

Good to know

  • F3--08TAS, F3--08TRS--1 and F3--08TRS--2: 125--250 VAC operation requires external fuses. p. 12, 19, 20
  • F3--16TA--2: the fuse blows at a 20 amp surge. p. 16
  • Relay modules draw more internal power and have a limited relay life. p. 3
  • Arc suppression can lengthen relay contact life beyond the listed values. p. 19
  • Base power use varies by module; the power budget section in chapter 4 explains how to plan it. p. 3

Questions this manual answers

Which DL305 output modules are relay modules?

The D3--08TR, F3--08TRS--1, F3--08TRS--2 and D3--16TR. p. 1

What replacement fuse does the F3--08TAS--1 use?

A 5A, 125V fast blow fuse, ordered as D3--FUSE--4 in packs of 5. p. 13

Can the F3--08TRS--1 switch a motor starter?

Yes, motor starters up to and including NEMA size 4 can be used with it. p. 19

How do I tell a DL305 output module from an input module?

Output modules have a red color bar on the front below the part number; input modules have blue. p. 2

How do I protect F3--08TRS relay contacts from arcing?

Add an RC network across the relay contacts, plus a diode across a DC inductive load, sized with the formulas or nomogram given. p. 4, 5

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Discrete Output Modules1
  2. Discrete Output Module Identification and Terminology2
  3. Relay Arc Suppression - DC and AC Applications4
  4. D3-08TD1, 24 VDC Output Module6
  5. D3-08TD2, 24 VDC Output Module7
  6. D3-16TD1-1, 24 VDC Output Module8
  7. D3-16TD1-2, 24 VDC Output Module9
  8. D3-16TD2, 24 VDC Output Module10
  9. D3-04TAS, 110-220 VAC Output Module11
  10. F3-08TAS, 250 VAC Isolated Output Module12
  11. F3-08TAS-1, 125 VAC Isolated Output Module13
  12. D3-08TA-1, 110-220 VAC Output Module14
  13. D3-08TA-2, 110-220 VAC Output Module15
  14. F3-16TA-2, 20-125 VAC Output Module16
  15. D3-16TA-2, 110-220 VAC Output Module17
  16. D3-08TR, Relay Output Module18
  17. F3-08TRS-1, Relay Output Module19
  18. F3-08TRS-2, Relay Output Module20
  19. D3-16TR, Relay Output Module21

From the PDF’s own bookmarks.

The whole text · 3 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 81-8
  2. Pages 9 to 169-16
  3. Pages 17 to 2217-22

The file

Revision and size

RevisionDL305 User Manual, Rev. D
Pages22
PDF517 KB
TextText from the PDF itself.

The first pages · 3 of 22

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 22
Page 2
Page 2of 22
Page 3
Page 3of 22