Spec sheet · Lenze
SMVector Frequency Inverter
Spec sheet8 pagesPDF 1.3 MB
Product brochure for the Lenze SMVector frequency inverter (AC drive), .33 to 60 Hp, in NEMA 1 and NEMA 4X versions.
Covers · 1 model
The models it covers
Summary
What is in it
A product brochure for the Lenze SMVector frequency inverter, an AC drive range from .33 to 60 Hp (.25 to 45 kW) in IP31 (NEMA 1) and IP65 (NEMA 4/4X) housings. It covers features and modes of operation, the Electronic Programming Module (EPM), performance examples, specifications for control, protection, monitoring and environment, the keypad and display, network connectivity options, and ratings and dimensions tables with model numbers.
Its parts
- Features and Benefits
- Performance
- Specifications
- Connectivity
- Ratings & Dimensions
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
Lenze product brochure for the SMVector (SMV) frequency inverter range, .33 to 60 Hp, in NEMA 1 (IP31) and NEMA 4X (IP65) enclosures. It describes the control modes, I/O, keypad, memory module and communication options. It also lists the ESV model numbers by input voltage and power, with enclosure dimensions by size code.
- Device
- AC frequency inverter drive, .33 to 60 Hp (.25 to 45 kW), IP31 (NEMA 1) or IP65 (NEMA 4/NEMA 4X) p. 1
- Input voltages
- 120/240V 1Ø up to 1.5 Hp; 200/240V 1/3Ø up to 3 Hp; 200/240V 3Ø up to 20 Hp; 400/480V and 480/600V 3Ø up to 60 Hp p. 2
- Control modes
- V/Hz, enhanced V/Hz, vector speed control with 60:1 speed range, vector torque control p. 2
- Output frequency
- 500 Hz; carrier frequency 4, 6, 8 or 10 kHz p. 4
- Ambient temperature
- -10 to 55°C, derate 2.5% per °C above 40°C p. 4
- Voltage tolerance
- +10/-15% p. 4
- Control terminals
- Dedicated start/stop and 3 programmable digital inputs; Form A relay and open collector outputs; 0-10 VDC and 4-20 mA analog inputs; 0-10/2-10 VDC analog output p. 5
- Memory module
- Electronic Programming Module (EPM) holds the parameter setup, plugs into a replacement drive, and can be swapped with or without power p. 2
- Communications
- RS-485 Modbus terminals on NEMA1 15HP and greater models; optional plug-in communication modules snap into the terminal cover p. 5, 6
- Keypad
- Six buttons (Start, Stop, Forward/Reverse, Scroll Up, Scroll Down, Enter/Mode), LED display, five status LEDs p. 5
- Speed commands
- Keypad, potentiometer, jog, 8 preset speeds, 16-segment sequencer, scalable 0-10 VDC or 4-20 mA p. 4
- Braking
- DC injection braking, optional dynamic braking, flux braking p. 4
- Fault history
- 8 register fault history p. 4
- Model example
- ESV751N04TXB: 1 Hp (0.75 kW), 400/480V 3Ø input, NEMA1, size G1 p. 7
What this sheet walks you through
- Choosing a model number by voltage, power and enclosure p. 7, 8
- Checking enclosure dimensions by size code p. 8
- Copying a drive setup with the EPM p. 2
- Adding a network communication module p. 6
- Keypad buttons, status LEDs and control terminals p. 5
Good to know
- 120/240V models give 0-230V output even when fed 120V. p. 7
- Model ESV251N02SXB takes single-phase input only. p. 7
- The disconnect switch and potentiometer options are for NEMA 4X models only. p. 2
- Above 40°C the drive is derated 2.5% per °C. p. 4
Questions this sheet answers
What horsepower range does the Lenze SMVector cover?
.33 to 60 Hp (.25 to 45 kW). p. 1
What is the SMVector maximum output frequency?
500 Hz. p. 4
Can an SMVector run a 230V motor from 120V single-phase?
The 120/240V single-phase models, up to 1.5 Hp, give 0-230V output even with 120V input. p. 2, 7
Does the SMVector have Modbus?
NEMA1 models of 15HP and greater have RS-485 Modbus terminals; optional plug-in communication modules are also offered. p. 5, 6
What is the EPM on an SMVector drive?
The Electronic Programming Module keeps the drive's parameter setup, so a replacement drive is set up by plugging it in. p. 2
The whole text · 1 part
Read the sheet here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file