Spec sheet · Lenze
Lenze SMVector Spec Sheet
Spec sheet2 pagesPDF 295 KB
Both pages are below, each with its text.
Covers · 1 model
The models it covers
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
Lenze two-page data sheet (DS-V101E) for the SMVector NEMA1 standard duty inverter. Page one lists the control modes, keypad, terminals, protection functions and environment. Page two gives the ESV model numbers with power and output current from 0.33 to 60 Hp, dimensions, and part numbers for communication modules, remote keypads, I/O modules and braking modules.
- Device
- SMVector NEMA1 standard duty AC inverter, 0.33 to 60 Hp p. 1, 2
- Input voltages
- 120/240V 1Ø; 200/240V 1 or 3Ø; 200/240V 3Ø; 400/480V 3Ø; 480/600V 3Ø; +10/-15% tolerance p. 1
- Control modes
- Open loop flux vector speed or torque control with or without auto tuning; V/Hz; enhanced V/Hz with auto-tuning p. 1
- Output frequency
- 500 Hz; carrier frequency 4, 6, 8 or 10 kHz p. 1
- Ambient temperature
- -10 to 55°C, derate 2.5% per °C above 40°C p. 1
- Status outputs
- Programmable Form A relay, programmable open collector, scalable 0-10 VDC / 2-10 VDC analog output, 4-20mA w/500 Ohm p. 1
- Speed commands
- Keypad, potentiometer, jog, 8 preset speeds, 16-segment sequencer, scalable 0-10 VDC or 4-20 mA p. 1
- 15 HP and up terminals
- 15 HP & up: extra programmable digital input, common, and RS-485 Modbus (TXA, TXB) p. 1
- Communication modules
- ESVZAC0 CANopen, ESVZAR0 RS-485/Modbus, ESVZAP0 PROFIBUS DP, ESVZAD0 DeviceNet, ESVZAE0 EtherNet/IP p. 2
- Remote keypads
- ESVZXK1 with drive interface module and cable, up to 10HP (7.5kW); ESVZXH0 with cable, 15HP (11kW) and up p. 2
- Additional I/O
- ESVZAL0 Form C relay output module; ESVZAL1 module with 1 Form C relay output and 2 digital inputs p. 2
- Braking modules
- EZXDB modules with built-in resistors for 0.33 to 10 HP; EZXDC1532A1, EZXDC2234A1 and EZXDC2236A1 without resistors for 15 HP and larger p. 2
- Restarts
- Four restarts, three flying and one auto, user enabled p. 1
- Fault history
- 8 register fault history p. 1
What this sheet walks you through
- Finding the model number, size and output current by voltage and horsepower p. 2
- Choosing communication, keypad and I/O options p. 2
- Choosing dynamic braking modules and resistors p. 2
- Keypad buttons, status LEDs and control modes p. 1
Good to know
- Only one communication module can be installed and used at a time. p. 2
- Additional I/O modules cannot be used with communication modules or the ESVZXK1 remote keypad. p. 2
- Model ESV251N02SXB takes single-phase input only. p. 2
- 120/240V models give 0-230V output even when fed 120V. p. 2
Questions this sheet answers
Which network modules fit the Lenze SMVector?
ESVZAC0 CANopen, ESVZAR0 RS-485/Modbus, ESVZAP0 PROFIBUS DP, ESVZAD0 DeviceNet and ESVZAE0 EtherNet/IP, one at a time. p. 2
What remote keypad fits a 15 HP SMVector?
ESVZXH0, the remote keypad with cable for 15HP (11kW) and up. p. 2
Can an SMVector use an I/O module and a communication module together?
No. Additional I/O modules cannot be used with communication modules or the ESVZXK1 remote keypad. p. 2
What output current does the SMVector ESV402N02TXB give?
16.5 A; it is the 5 Hp (4 kW) 200/240V three-phase model in size G3. p. 2
What carrier frequencies does the SMVector support?
4, 6, 8 or 10 kHz. p. 1
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
SMVector NEMA1
Standard Duty Inverter Keypad & Display Simple Six Button Programming
- Start
- Stop
- Forward/Reverse
- Scroll Up
- Scroll Down
- Enter/Mode
Informative LED Display
World Class Control
Modes of Operation Open Loop Flux Vector, Speed or Torque Control with/without Auto Tuning V/Hz (Constant or Variable) Base Frequency Adjustable to Motor Specs Enhanced V/Hz with Auto-tuning Acceleration/Deceleration Profiles Two Independent Accel Ramps Two Independent Decel Ramps Linear, S-Type Auxiliary Ramp(or Coast)-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency High Carrier (PWM Sine-Coded) Frequency 4, 6, 8, 10 kHz Universal Logic Assertion (Selectable) Positive or Negative Logic Input Digital Reference Available Braking Functions DC Injection Braking Optional Dynamic Braking Flux Braking w/ Adjustable Flux Level & Decel Time Speed Commands Keypad, Potentiometer Jog, 8 Preset Speeds Floating Point Control Sequencer, 16 Segments Voltage: Scalable 0 –10 VDC Current: Scalable 4 – 20 mA Process Control PID Modes: Direct and Reverse Acting PID Sleep Mode w/ Adjustable Recovery Threshold Analog Output (Speed, Load, Torque, kW) Network Speed (Baud Rate) Terminal and Keypad Status Elapsed Run or Power On Time (Hours) Status Outputs Programmable Form “A” Relay Output Programmable Open Collector Output Scalable 0-10 VDC / 2-10 VDC Analog Output 4-20mA w/500 Ohm Total Impedance
Environment
Ambient Temperature -10 to 55°C Derate 2.5% per °C Above 40°C
Comprehensive Diagnostic Tools Real Time Monitoring 8 Register Fault History Software Version Drive Network ID DC Bus Voltage (V) Motor Voltage (V) Output Current (%) Motor Current (A) Motor Torque (%) Power (kW) Energy Consumption (kWh) Heatsink Temperature (°C) 0 – 10 VDC Input (User Defined) 4 – 20 mA Input (User Defined) PID Feedback (User Defined)
Vigilant System Protection
Voltage Monitoring Low and High DC Bus V Protection Low Line V Compensation Current Monitoring Motor Overload Protection Current Limiting Safeguard Ground Fault Short Circuit Protection Four ReStarts Three Flying and One Auto User Enabled Loss of Follower Management Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification Over Temperature Protection
International Voltages +10/-15% Tolerance 120/240V, 1Ø 200/240V, 1 or 3Ø 200/240V, 3Ø 400/480V, 3Ø 480/600V, 3Ø
Global Standards UL GOST cUL C-Tick CE Low Voltage (EN61800-5-1) CE EMC (EN61800-3) with optional EMC filter
Vivid Illumination Easily Read from a Distance Five Status LEDs
- Run
- Automatic Speed mode
- Manual Speed Mode
- Forward Rotation
- Reverse Rotation Status Display
- Motor Status
- Fault Management
- Operational Information AUTO
FWDREVRUNSTOP
NEMA1 (Up to 10HP) Keypad NEMA1 (15HP and greater) Keypad CTRL
REMOTEMANHzRPMLOCALAUTO%AMPS /UNITSAUTOFWDREVRUNSTOP
Additional CTRL Button Switch between control modes
- Local-Manual
- Local Auto
- Remote-Manual • Remote Auto
Additional LED Indicators Define the units being displayed
- Hz
- RPM
- %
- Amps • /Units
Control Terminals
Digital Inputs Digital Outputs
- Dedicated Start/Stop • Form “A” Relay
- (3) Programmable
- Open Collector Analog Inputs Analog Outputs
- 0 - 10 VDC
- 0 - 10 VDC
- 4 - 20 mA
- 2 - 10 VDC Power Supplies
- 10 VDC Potentiometer Ref
- 12 VDC, 20 mA DI Ref or 0VDC Com
- 12 VDC, 50 mA Supply Common
Additional Control Terminals (15 HP & up) 1 Programmable Digital Input 1 Common RS-485 Modbus Communications
- TXA
- TXB
Lenze Americas • 630 Douglas Street • Uxbridge, MA 01569 • USA • Sales 800 217-9100 • Service 508 278-9100 • www.lenzeamericas.com
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
SMVector NEMA1 Ratings
Standard Duty Inverter Dimensions Dimensions
120/240V* - 1Ø Input (3Ø Output) Power
Output CurrentNEMA1HpkWIN [A]ModelSize0.33 0.5 1 1.50.25 0.37 0.75 1.11.7 2.4 4.2 6.0
ESV251N01SXB ESV371N01SXB ESV751N01SXB ESV112N01SXB
G1 G1 G1 G2
G1 G2 G3 H1 J1 K1 K2 K3
*120/240V models provide 0-230V output even with 120V input applied.
200/240V - 1 or 3Ø Input (3Ø Output) Power
Output Current
in. 7.50 7.60 7.60 9.90 12.50 14.19 17.19 20.19
H
mm 190 191 191 250 318 360 436 513
in. 3.90 3.90 3.90 5.20 7.00 8.72 8.72 8.72
W
mm 99 99 99 130 176 221 221 221
in. 4.40 5.50 5.80 6.30 8.10 10.07 10.07 10.07
D
mm 111 138 147 160 205 256 256 256
NEMA1HpkWIN [A]ModelSize0.330.251.7ESV251N02SXB***G10.50.372.4ESV371N02YXBG110.754.2ESV751N02YXBG11.51.16.0ESV112N02YXBG221.57.0ESV152N02YXBG232.29.6ESV222N02YXBG2SMV NEMA 1 (IP31)
***Model ESV251N02SXB is single-phase input only.
200/240V - 3Ø Input (3Ø Output) Power
Output Current
Bottom Entry with IP21 Finger Guard
NEMA1HpkWIN [A]ModelSize1.51.16.0ESV112N02TXBG221.57.0ESV152N02TXBG232.29.6ESV222N02TXBG25416.5ESV402N02TXBG37.55.523ESV552N02TXBH1107.529ESV752N02TXBH1151142ESV113N02TXBJ1201554ESV153N02TXBJ1HD
400/480V - 3Ø Input (3Ø Output) Power
Output CurrentHpkW0.5 1ModelSize0.371.3/1.1ESV371N04TXBG10.752.4/2.1ESV751N04TXBG11.51.13.5/3.0ESV112N04TXBG221.54.0/3.5ESV152N04TXBG232.25.5/4.8ESV222N04TXBG2549.4/8.2ESV402N04TXBG37.55.512.6/11ESV552N04TXBH1107.516.1/14ESV752N04TXBH1151124/21ESV113N04TXBJ1201531/27ESV153N04TXBJ12518.539/34ESV183N04TXBJ1302246/40ESV223N04TXBJ1403060/52ESV303N04TXBK15037.575/65ESV373N04TXBK2604588/77ESV453N04TXBK3
600V - 3Ø Input (3Ø Output) Power
Output CurrentWNEMA1IN [A]NEMA1HpkWIN [A]ModelSize10.751.7ESV751N06TXBG121.52.7ESV152N06TXBG232.23.9ESV222N06TXBG2546.1ESV402N06TXBG37.55.59ESV552N06TXBH1107.511ESV752N06TXBH1151117ESV113N06TXBJ1201522ESV153N06TXBJ12518.527ESV183N06TXBJ1302232ESV223N06TXBJ1403041ESV303N06TXBK15037.552ESV373N06TXBK2604562ESV453N06TXBK3
Bottom Entry with NEMA 1 (IP31) Steel Conduit Plate
Options Communication Modules * Item Number
Item Description
ESVZAC0
CANopen Communications Interface Module
ESVZAR0
RS-485/Modbus Communications Interface Module
ESVZAP0
PROFIBUS DP Communications Interface Module
ESVZAD0
DeviceNet Communications Interface Module
ESVZAE0
EtherNet/IP Communications Interface Module
- Only one Communication module can be installed and used at a time.
Keypad ESVZXK1
Remote Keypad w/ drive interface module & cable up to 10HP (7.5kW)
ESVZXH0
Remote Keypad w/ cable 15HP (11kW) and up
Additional I/O ** ESVZAL0
Additional Form C Relay Output Module
ESVZAL1
Additional I/O Module w/ 1 Form C Relay Output and 2 Digital Inputs
** Additional I/O modules cannot be used with Communication modules or Remote keypad ESVZXK1.
Dynamic Braking Modules with Built-in Resistors Motor Voltage HP
(kW)
208 to 230 V Part Number
400 to 480 V Part Number
480 to 600 V Part Number
0.33 - 0.5(0.25-0.37)EZXDB3712A1EZXDB3714A1N/A1 - 1.5(0.75 - 1.1)EZXDB1122A1EZXDB1124A1EZXDB1126A12-3(1.5 - 2.2)EZXDB2222A1EZXDB2224A1EZXDB2226A15(4)EZXDB4022A1EZXDB4024A1EZXDB4026A17.5(5.5)EZXDB5522A1EZXDB5524A1EZXDB5526A110(7.5)EZXDB7522A1EZXDB7524A1EZXDB7526A1
Dynamic Braking Modules without Built-in Resistors 15 - 20
(11 - 15)EZXDC1532A1N/AN/A15 - 30(11 - 22)N/AEZXDC2234A1EZXDC2236A1
Open Dynamic Braking Resistors with mounting brackets 15 - 20
(11 - 15)841-009841-009841-01025 - 30(18.5 - 22)N/A841-011841-012
Lenze Americas • 630 Douglas Street • Uxbridge, MA 01569 • USA • Sales 800 217-9100 • Service 508 278-9100 • www.lenzeamericas.com DS-V101E