Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of Lenze SMVector Spec Sheet

Spec sheet · Lenze

Lenze SMVector Spec Sheet

Spec sheet2 pagesPDF 295 KB

Both pages are below, each with its text.

Download the PDF295 KB

Covers · 1 model

The models it covers

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

Lenze two-page data sheet (DS-V101E) for the SMVector NEMA1 standard duty inverter. Page one lists the control modes, keypad, terminals, protection functions and environment. Page two gives the ESV model numbers with power and output current from 0.33 to 60 Hp, dimensions, and part numbers for communication modules, remote keypads, I/O modules and braking modules.

Device
SMVector NEMA1 standard duty AC inverter, 0.33 to 60 Hp p. 1, 2
Input voltages
120/240V 1Ø; 200/240V 1 or 3Ø; 200/240V 3Ø; 400/480V 3Ø; 480/600V 3Ø; +10/-15% tolerance p. 1
Control modes
Open loop flux vector speed or torque control with or without auto tuning; V/Hz; enhanced V/Hz with auto-tuning p. 1
Output frequency
500 Hz; carrier frequency 4, 6, 8 or 10 kHz p. 1
Ambient temperature
-10 to 55°C, derate 2.5% per °C above 40°C p. 1
Status outputs
Programmable Form A relay, programmable open collector, scalable 0-10 VDC / 2-10 VDC analog output, 4-20mA w/500 Ohm p. 1
Speed commands
Keypad, potentiometer, jog, 8 preset speeds, 16-segment sequencer, scalable 0-10 VDC or 4-20 mA p. 1
15 HP and up terminals
15 HP & up: extra programmable digital input, common, and RS-485 Modbus (TXA, TXB) p. 1
Communication modules
ESVZAC0 CANopen, ESVZAR0 RS-485/Modbus, ESVZAP0 PROFIBUS DP, ESVZAD0 DeviceNet, ESVZAE0 EtherNet/IP p. 2
Remote keypads
ESVZXK1 with drive interface module and cable, up to 10HP (7.5kW); ESVZXH0 with cable, 15HP (11kW) and up p. 2
Additional I/O
ESVZAL0 Form C relay output module; ESVZAL1 module with 1 Form C relay output and 2 digital inputs p. 2
Braking modules
EZXDB modules with built-in resistors for 0.33 to 10 HP; EZXDC1532A1, EZXDC2234A1 and EZXDC2236A1 without resistors for 15 HP and larger p. 2
Restarts
Four restarts, three flying and one auto, user enabled p. 1
Fault history
8 register fault history p. 1

What this sheet walks you through

  • Finding the model number, size and output current by voltage and horsepower p. 2
  • Choosing communication, keypad and I/O options p. 2
  • Choosing dynamic braking modules and resistors p. 2
  • Keypad buttons, status LEDs and control modes p. 1

Good to know

  • Only one communication module can be installed and used at a time. p. 2
  • Additional I/O modules cannot be used with communication modules or the ESVZXK1 remote keypad. p. 2
  • Model ESV251N02SXB takes single-phase input only. p. 2
  • 120/240V models give 0-230V output even when fed 120V. p. 2

Questions this sheet answers

Which network modules fit the Lenze SMVector?

ESVZAC0 CANopen, ESVZAR0 RS-485/Modbus, ESVZAP0 PROFIBUS DP, ESVZAD0 DeviceNet and ESVZAE0 EtherNet/IP, one at a time. p. 2

What remote keypad fits a 15 HP SMVector?

ESVZXH0, the remote keypad with cable for 15HP (11kW) and up. p. 2

Can an SMVector use an I/O module and a communication module together?

No. Additional I/O modules cannot be used with communication modules or the ESVZXK1 remote keypad. p. 2

What output current does the SMVector ESV402N02TXB give?

16.5 A; it is the 5 Hp (4 kW) 200/240V three-phase model in size G3. p. 2

What carrier frequencies does the SMVector support?

4, 6, 8 or 10 kHz. p. 1

The file

Size and text

Pages2
PDF295 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Lenze SMVector Spec Sheet

The text of page 1, from the PDF itself

SMVector NEMA1

Standard Duty Inverter Keypad & Display Simple Six Button Programming

  • Start
  • Stop
  • Forward/Reverse
  • Scroll Up
  • Scroll Down
  • Enter/Mode

Informative LED Display

World Class Control

Modes of Operation Open Loop Flux Vector, Speed or Torque Control with/without Auto Tuning V/Hz (Constant or Variable) Base Frequency Adjustable to Motor Specs Enhanced V/Hz with Auto-tuning Acceleration/Deceleration Profiles Two Independent Accel Ramps Two Independent Decel Ramps Linear, S-Type Auxiliary Ramp(or Coast)-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency High Carrier (PWM Sine-Coded) Frequency 4, 6, 8, 10 kHz Universal Logic Assertion (Selectable) Positive or Negative Logic Input Digital Reference Available Braking Functions DC Injection Braking Optional Dynamic Braking Flux Braking w/ Adjustable Flux Level & Decel Time Speed Commands Keypad, Potentiometer Jog, 8 Preset Speeds Floating Point Control Sequencer, 16 Segments Voltage: Scalable 0 –10 VDC Current: Scalable 4 – 20 mA Process Control PID Modes: Direct and Reverse Acting PID Sleep Mode w/ Adjustable Recovery Threshold Analog Output (Speed, Load, Torque, kW) Network Speed (Baud Rate) Terminal and Keypad Status Elapsed Run or Power On Time (Hours) Status Outputs Programmable Form “A” Relay Output Programmable Open Collector Output Scalable 0-10 VDC / 2-10 VDC Analog Output 4-20mA w/500 Ohm Total Impedance

Environment

Ambient Temperature -10 to 55°C Derate 2.5% per °C Above 40°C

Comprehensive Diagnostic Tools Real Time Monitoring 8 Register Fault History Software Version Drive Network ID DC Bus Voltage (V) Motor Voltage (V) Output Current (%) Motor Current (A) Motor Torque (%) Power (kW) Energy Consumption (kWh) Heatsink Temperature (°C) 0 – 10 VDC Input (User Defined) 4 – 20 mA Input (User Defined) PID Feedback (User Defined)

Vigilant System Protection

Voltage Monitoring Low and High DC Bus V Protection Low Line V Compensation Current Monitoring Motor Overload Protection Current Limiting Safeguard Ground Fault Short Circuit Protection Four ReStarts Three Flying and One Auto User Enabled Loss of Follower Management Protective Fault Go to Preset Speed or Preset Setpoint Initiate System Notification Over Temperature Protection

International Voltages +10/-15% Tolerance 120/240V, 1Ø 200/240V, 1 or 3Ø 200/240V, 3Ø 400/480V, 3Ø 480/600V, 3Ø

Global Standards UL GOST cUL C-Tick CE Low Voltage (EN61800-5-1) CE EMC (EN61800-3) with optional EMC filter

Vivid Illumination Easily Read from a Distance Five Status LEDs

  • Run
  • Automatic Speed mode
  • Manual Speed Mode
  • Forward Rotation
  • Reverse Rotation Status Display
  • Motor Status
  • Fault Management
  • Operational Information AUTO

FWDREVRUNSTOP

NEMA1 (Up to 10HP) Keypad NEMA1 (15HP and greater) Keypad CTRL

REMOTEMANHzRPMLOCALAUTO%AMPS /UNITSAUTOFWDREVRUNSTOP

Additional CTRL Button Switch between control modes

  • Local-Manual
  • Local Auto
  • Remote-Manual • Remote Auto

Additional LED Indicators Define the units being displayed

  • Hz
  • RPM
  • %
  • Amps • /Units

Control Terminals

Digital Inputs Digital Outputs

  • Dedicated Start/Stop • Form “A” Relay
  • (3) Programmable
  • Open Collector Analog Inputs Analog Outputs
  • 0 - 10 VDC
  • 0 - 10 VDC
  • 4 - 20 mA
  • 2 - 10 VDC Power Supplies
  • 10 VDC Potentiometer Ref
  • 12 VDC, 20 mA DI Ref or 0VDC Com
  • 12 VDC, 50 mA Supply Common

Additional Control Terminals (15 HP & up) 1 Programmable Digital Input 1 Common RS-485 Modbus Communications

  • TXA
  • TXB

Lenze Americas • 630 Douglas Street • Uxbridge, MA 01569 • USA • Sales 800 217-9100 • Service 508 278-9100 • www.lenzeamericas.com

Page 2 of Lenze SMVector Spec Sheet

The text of page 2, from the PDF itself

SMVector NEMA1 Ratings

Standard Duty Inverter Dimensions Dimensions

120/240V* - 1Ø Input (3Ø Output) Power

Output CurrentNEMA1HpkWIN [A]ModelSize0.33 0.5 1 1.50.25 0.37 0.75 1.11.7 2.4 4.2 6.0

ESV251N01SXB ESV371N01SXB ESV751N01SXB ESV112N01SXB

G1 G1 G1 G2

G1 G2 G3 H1 J1 K1 K2 K3

*120/240V models provide 0-230V output even with 120V input applied.

200/240V - 1 or 3Ø Input (3Ø Output) Power

Output Current

in. 7.50 7.60 7.60 9.90 12.50 14.19 17.19 20.19

H

mm 190 191 191 250 318 360 436 513

in. 3.90 3.90 3.90 5.20 7.00 8.72 8.72 8.72

W

mm 99 99 99 130 176 221 221 221

in. 4.40 5.50 5.80 6.30 8.10 10.07 10.07 10.07

D

mm 111 138 147 160 205 256 256 256

NEMA1HpkWIN [A]ModelSize0.330.251.7ESV251N02SXB***G10.50.372.4ESV371N02YXBG110.754.2ESV751N02YXBG11.51.16.0ESV112N02YXBG221.57.0ESV152N02YXBG232.29.6ESV222N02YXBG2SMV NEMA 1 (IP31)

***Model ESV251N02SXB is single-phase input only.

200/240V - 3Ø Input (3Ø Output) Power

Output Current

Bottom Entry with IP21 Finger Guard

NEMA1HpkWIN [A]ModelSize1.51.16.0ESV112N02TXBG221.57.0ESV152N02TXBG232.29.6ESV222N02TXBG25416.5ESV402N02TXBG37.55.523ESV552N02TXBH1107.529ESV752N02TXBH1151142ESV113N02TXBJ1201554ESV153N02TXBJ1HD

400/480V - 3Ø Input (3Ø Output) Power

Output CurrentHpkW0.5 1ModelSize0.371.3/1.1ESV371N04TXBG10.752.4/2.1ESV751N04TXBG11.51.13.5/3.0ESV112N04TXBG221.54.0/3.5ESV152N04TXBG232.25.5/4.8ESV222N04TXBG2549.4/8.2ESV402N04TXBG37.55.512.6/11ESV552N04TXBH1107.516.1/14ESV752N04TXBH1151124/21ESV113N04TXBJ1201531/27ESV153N04TXBJ12518.539/34ESV183N04TXBJ1302246/40ESV223N04TXBJ1403060/52ESV303N04TXBK15037.575/65ESV373N04TXBK2604588/77ESV453N04TXBK3

600V - 3Ø Input (3Ø Output) Power

Output CurrentWNEMA1IN [A]NEMA1HpkWIN [A]ModelSize10.751.7ESV751N06TXBG121.52.7ESV152N06TXBG232.23.9ESV222N06TXBG2546.1ESV402N06TXBG37.55.59ESV552N06TXBH1107.511ESV752N06TXBH1151117ESV113N06TXBJ1201522ESV153N06TXBJ12518.527ESV183N06TXBJ1302232ESV223N06TXBJ1403041ESV303N06TXBK15037.552ESV373N06TXBK2604562ESV453N06TXBK3

Bottom Entry with NEMA 1 (IP31) Steel Conduit Plate

Options Communication Modules * Item Number

Item Description

ESVZAC0

CANopen Communications Interface Module

ESVZAR0

RS-485/Modbus Communications Interface Module

ESVZAP0

PROFIBUS DP Communications Interface Module

ESVZAD0

DeviceNet Communications Interface Module

ESVZAE0

EtherNet/IP Communications Interface Module

  • Only one Communication module can be installed and used at a time.

Keypad ESVZXK1

Remote Keypad w/ drive interface module & cable up to 10HP (7.5kW)

ESVZXH0

Remote Keypad w/ cable 15HP (11kW) and up

Additional I/O ** ESVZAL0

Additional Form C Relay Output Module

ESVZAL1

Additional I/O Module w/ 1 Form C Relay Output and 2 Digital Inputs

** Additional I/O modules cannot be used with Communication modules or Remote keypad ESVZXK1.

Dynamic Braking Modules with Built-in Resistors Motor Voltage HP

(kW)

208 to 230 V Part Number

400 to 480 V Part Number

480 to 600 V Part Number

0.33 - 0.5(0.25-0.37)EZXDB3712A1EZXDB3714A1N/A1 - 1.5(0.75 - 1.1)EZXDB1122A1EZXDB1124A1EZXDB1126A12-3(1.5 - 2.2)EZXDB2222A1EZXDB2224A1EZXDB2226A15(4)EZXDB4022A1EZXDB4024A1EZXDB4026A17.5(5.5)EZXDB5522A1EZXDB5524A1EZXDB5526A110(7.5)EZXDB7522A1EZXDB7524A1EZXDB7526A1

Dynamic Braking Modules without Built-in Resistors 15 - 20

(11 - 15)EZXDC1532A1N/AN/A15 - 30(11 - 22)N/AEZXDC2234A1EZXDC2236A1

Open Dynamic Braking Resistors with mounting brackets 15 - 20

(11 - 15)841-009841-009841-01025 - 30(18.5 - 22)N/A841-011841-012

Lenze Americas • 630 Douglas Street • Uxbridge, MA 01569 • USA • Sales 800 217-9100 • Service 508 278-9100 • www.lenzeamericas.com DS-V101E

More documents · 1

For the same models