Spec sheet · Leuze
AS-Interface Safety at Work: Safety Monitors, ASM1, ASM1E
Spec sheet7 pagesPDF 416 KB
Catalog pages for the Leuze ASM1 and ASM1E AS-i Safety Monitors: functions, ordering data, wiring example and technical data.
Names · 1 model
The models it names
Filed with · 1 model
Also filed with these models on the old site
Summary
What is in it
Leuze catalog pages for the ASM1 and ASM1E AS-Interface Safety at Work safety monitors, which watch the safety-related AS-i bus participants (light curtains, safety switches, control devices) and drive one or two release circuits. The pages compare the ASM1, ASM1E and ASM1E-m (muting) variants, list article numbers, show an ASM1 connection example with a light curtain, and give technical data, safety ratings and dimensions.
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
Leuze catalog pages (2010) for the ASM1 and ASM1E AS-i Safety Monitors, covering the versions ASM1/1, ASM1/2, ASM1E/1, ASM1E/2, ASM1E-m/1 and ASM1E-m/2. They give the functions of each version, article numbers, a connection example, technical data and dimensions. A reader can use them to identify a monitor, compare versions and wire it.
- What it is
- AS-i Safety Monitor that watches the safety-related AS-Interface bus participants assigned to it and switches release circuits p. 1
- Versions
- ASM1/1 (580020) and ASM1E/1 (580024): 1 release circuit; ASM1/2 (580021) and ASM1E/2 (580025): 2 release circuits; Muting versions ASM1E-m/1 (580055), ASM1E-m/2 (580056) p. 4
- Supply
- 24 V DC, ±15%; 150 mA (ASM1/1, ASM1E/1), 200 mA (ASM1/2, ASM1E/2) p. 2, 6
- Safety outputs
- Up to 2 potential-free safety-related switching outputs (OSSDs); max. contact load 1 A with 24 V DC, 3 A with 230 V AC p. 7
- AS-i network
- Up to 31 safe AS-i slaves; 4 Safety Monitors per AS-Interface network p. 2, 6
- Configuration interface
- RS 232 at 9600 baud, no parity, 1 start bit, 1 stop bit, 8 data bits; asimon configuration and diagnostics software p. 2, 6
- Function modules
- ASM1/1 and ASM1/2: 32; ASM1E/1 and ASM1E/2: 48 p. 3
- Dimensions
- 45 mm x 105 mm x 120 mm (W x H x D) p. 2, 6
- Operating temperature
- -20...+60°C p. 2
- Housing and mounting
- Polyamide PA 66 housing; snap-on fastening on DIN rails in accordance with EN 50022 p. 6
- Inputs and signal output
- Start and feedback inputs: opto-coupled, high-active, approx. 10 mA at 24 V DC; signal output: pnp transistor, 200 mA p. 7
- Fuse
- External, max. 4 A MT p. 7
- Wire sizes
- 1x 0.5 to 4.0 mm2 and 2x 0.5 to 2.5 mm2 (single-wired); 2x 20 to 14 (AWG) p. 6
- Safety ratings
- The manual states SIL 3, PL e and Category 4 p. 2
What this sheet walks you through
- Configuring and diagnosing the monitor from a PC over RS 232 p. 1, 2
- Comparing the functions of the ASM1 and ASM1E versions p. 3
- Ordering the right version by article number p. 4
- Wiring an ASM1 with a COMPACTplus light curtain p. 5
- Setting up Muting with the ASM1E-m versions p. 1, 2
Good to know
- IP 20 means the unit belongs only in electrical rooms or cabinets rated at least IP 54. p. 6
- The data sheet points to the connecting and operating instructions for further information. p. 7
- Programmable Muting logic is available only on the ASM1E-m/1 and ASM1E-m/2. p. 2
Questions this sheet answers
What is the article number of the Leuze ASM1/2?
580021, the AS-i Safety Monitor with 2 release circuits. p. 4
What power supply does the ASM1 need?
24 V DC ±15%, drawing 150 mA (ASM1/1) or 200 mA (ASM1/2). p. 2, 6
How many safe AS-i slaves can one ASM1 monitor?
Up to 31 safe AS-i slaves can be connected. p. 2
What is the difference between the ASM1 and ASM1E?
The ASM1E has 48 configurable function modules instead of 32, plus extra logic, diagnostics and an activation/deactivation mode. p. 1, 3
How is the ASM1 configured?
From a PC through its RS 232 interface, using the asimon configuration and diagnostics software. p. 2
The whole text · 1 part
Read the sheet here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file