The text of a spec sheet · part 1 of 1
AS-Interface Safety at Work: Safety Monitors, ASM1, ASM1E, pages 1 to 7
Pages 1 to 7 of 7
The original document is the PDF (416 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Leuze ASM1
Page 1
AS-Interface Safety at Work Safety Monitors, ASM1, ASM1E two dependent or independent release circuits with configurable contactor monitoring are available. With an extended scope of functions, the ASM1E device type provides even more convenience with the configuration and diagnostics of a safety application monitored via an AS-Interface. Besides additional logic and diagnostics functions, ASM1E also has an activation/deactivation mode for parameterized software modules. The machine manufacturer can therefore already prepare the configuration of the Safety Monitor in the preliminary stage for all safety sensors that could be used with an extension.
AS-Interface Safety at Work-based robot application with 2 release circuits
The ASM1E-m variants are additionally equipped with an integrated Muting function package to enable a continuous material flow, e.g. for automated production cells or packaging stations, while maintaining the protective function. The Muting sensors required for this are easily integrated via standard AS-Interface input slaves; a separate Muting controller is no longer required.
Typical areas of application z Automation networks based on AS-Interface Safety at Work in the lower field level z Mixed operation of AS-i standard components and safety-related components z Packaging systems, car manufacturing, conveyor and storage systems, machine tools, processing centers and production lines
The ASM Muting functionality enables palettes in a wrapping machine application, for example, to pass by the active opto-electronic protective device without any process interruption. The AS-i Safety Monitor, the ASM1, is a core component of the AS-Interface Safety at Work system. Using configuration software it monitors the safety-related bus participants that are assigned to it, e.g. control devices, Multiple Light Beam Safety Devices and Safety Switches. The Safety Monitor has an RS 232 diagnostics interface for the PC-supported configuration and diagnostics. Logical links can be easily created with the graphic user interface of the Windows® based software. The user can combine safety sensors and control devices with a mouse click and assign different release circuits for switching off the dangerous movement. Depending on the device type,
ASKM2, p. 338
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 2
Machine Safety
SAFETY MONITORS, ASM1, ASM1E
Machine Safety Services
Important technical data, overview
Max. 40 ms
Protection rating
IP 20
Ambient temperature, operation
-20...+60°C
Safety Laser Scanners
System response time
Features Safety Light Curtains
Dimensions (W x H x D) 45 mm x 105 mm x 120 mm
Multiple Light Beam Safety Devices
Number of Safety Monitors per 4 (with maximum 31 integrated AS-i slaves) AS-Interface network Safety-related switching Up to 2 potential-free safety-related switching outputs outputs (OSSDs) (1 A DC-13, 24 V DC / 3 A AC-15, 230 V AC)
Special features z Up to 31 safe AS-i slaves can be connected z Freely selectable assignment (Drag & Drop) of the sensor to outputz z z
Further information z Ordering information z Electrical connection z Technical data z Dimensional drawings z Accessories ordering information
Page 317 318 319 320 328 www.leuze.com/asi/
PROFIsafe Sensors
AS-Interface Safety at Work z z z side release circuits with easy to operate asimon configuration and diagnostics software 48 link modules (e.g. OR, AND, FLIPFLOP) and turn on/off delays can be configured RS 232 interface for PC-supported system configuration, system diagnostics as well as configuration data transfer to replacement device Immediate switch-off STOP 0 and delayed switch-off STOP 1 of the release circuits can be parametered SERVICE button for teach-in with sensor swap-out 2-sensor Parallel Muting or 4-sensor Sequential Muting (ASM1E) Programmable Muting logic (programmable with ASM1E-m/1 and ASM1E-m/2: Muting time extension, Muting timeout, Muting sensor signal filter, close sequence, direction change, Muting enable, Muting override mode with buttons or key switches)
Safety Sensor Sets
24 V DC, ±15%
Single Light Beam Safety Devices
Supply voltage
Safety Engineering Software
SIL in accordance with IEC 61508 and SILCL in SIL 3 accordance with IEC/EN 62061 Performance Level (PL) in accordance with PL e EN ISO 13849-1 Category in accordance 4 with EN ISO 13849 STOP category in accordance with 0 and 1 IEC/EN 60204-1
315 CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 3
AS-Interface Safety at Work Functions, ASM1, ASM1E ASM1/1
ASM1/2
ASM1E/1
ASM1E/2
Number of safety-related switching outputs (OSSDs)
1
2
1
2
Number of configurable function modules
32
32
48
48
PC configuration and diagnostics interface
RS 232
RS 232
RS 232
RS 232 z z
Monitoring modules with contact bounce filter Service button for manual error unlocking and automatic device swap-out of the safe AS-i slaves Status LED display for AS-Interface communication, OSSD, start/restart interlock, protective mode, errors z z z z z z z z
System signal output z z z z
6
6
Programmable logic operators, AND (inputs)
6
6
Programmable logic operators, FLIP-FLOP z z z z z z z z z z z z z z z z z z z z z z z z
Further functions (can be configured with asimon configuration and diagnostics software) Programmable logic operators, OR (inputs)
2
2
Programmable logic operators, switch on/off delay Programmable logic operators, system statuses z z z z z z z z z z z z z z z z z z
Programmable Muting logic STOP 0 / STOP 1 Start/restart interlock (RES), selectable Dynamic contactor monitoring (EDM), selectable Monitoring modules with contact-simultaneity monitoring Activation/deactivation of function modules Support of AS-Interface A/B technology Diagnostics data transfer via AS-Interface Error unlocking via AS-Interface
316 We reserve the right to make changes • 09-01_ASM1_ASM1E.fm
© 2010 Leuze electronic GmbH + Co. KG
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 4
Functions: Monitoring the AS-Interface Safety at Work bus participants, with selectable start/restart interlock, contactor monitoring, STOP 0/STOP 1, PC diagnostics interface
Article
Description
Safety-related switching outputs (OSSDs)
580020
ASM1/1
AS-i Safety Monitor
1 release circuit
580024
ASM1E/1
AS-i Safety Monitor, extended
1 release circuit
580021
ASM1/2
AS-i Safety Monitor
2 release circuits
580025
ASM1E/2
AS-i Safety Monitor, extended
2 release circuits
580055
ASM1E-m/1
AS-i Safety Monitor, extended, Muting
1 release circuit
580056
ASM1E-m/2
AS-i Safety Monitor, extended, Muting
2 release circuits
Machine Safety PROFIsafe Sensors
AS-Interface Safety at Work
Single Light Beam Safety Devices
Safety Sensor Sets
Multiple Light Beam Safety Devices
Safety Light Curtains
Art. no.
Safety Engineering Software
ASM1 and ASM1E Included in delivery: Device front screen for protection and sealing; connecting and operating instructions (short version)
Safety Laser Scanners
Ordering information
Machine Safety Services
SAFETY MONITORS, ASM1, ASM1E www.leuze.com/asi/ We reserve the right to make changes • 09-01_ASM1_ASM1E.fm
© 2010 Leuze electronic GmbH + Co. KG
317
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 5
AS-Interface Safety at Work Electrical connection ASM1 connection example
+ 24V
+ 24V
AS-i+
AS-i+
AS-i-
AS-i-
-S1
-K1
L+
L+
1
1
2
2
1.13
1.23
1.14
1.24
-K2 AS-i+ 1
AS-i3
4
AS-i+ 1
AS-i3
-A3
L+
4
1.Y2
AS-i+
AS-i-
1.Y1
CPT/A
ASM 1/ 1
0V
CPR/A
-A2
+ 24V
-A1
2
5
2
5
M
FE
1.32
Var. B Var. A
-K1
A1
-K1 -K1
-K2 -K2
A1
-K2 A2
A2
L-
L- x1 x2
0V PE
0V PE
ASM1 Safety Monitor with COMPACTplus Safety Light Curtain with integrated AS-Interface Please observe the operating instructions of the components!
318 We reserve the right to make changes • 09-01_ASM1_ASM1E.fm
© 2010 Leuze electronic GmbH + Co. KG
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 6
Machine Safety
SAFETY MONITORS, ASM1, ASM1E
SIL 3
Service life (TM ) in accordance with EN ISO 13849-1
20 years With DC1 (ohmic load) With AC1 (ohmic load)
Number of cycles until 10 % of the components have With DC13 (inductive load) a failure to danger (B10d) With AC15 (inductive load) Low load (20% nominal load)
10,000,000 (I < 2 A, 24 V) 100,000 (2 A, 230 V) 250,000 (1 A, 230 V) 540,000 (0.5 A, 230 V) On request
4
Safety Light Curtains
Category in accordance with EN ISO 13849
On request
STOP category in accordance with IEC/EN 60204-1 0 and 1 Supply voltage System response time (exclusive sensor response time) Readiness delay
24 V DC, ±15% Max. 40 ms
Ambient temperature, operation Ambient temperature, storage
Max. 10 s IP 20 (only suitable for use in electrical operating rooms/cabinets with IP 54 minimum protection rating) -20...+60°C -30... +70°C
Dimensions (W x H x D)
45 mm x 105 mm x 120 mm
Housing material Mounting
Polyamide PA 66 Snap-on fastening on DIN rails in accordance with EN 50022 1x 0.5 to 4.0 mm2 and 2x 0.5 to 2.5 mm2 (single-wired) 1x 0.5 to 2.5 mm2 and 2x 0.5 to 1.5 mm2 (multi-wire) 2x 20 to 14 (AWG)
Protection rating
Connection system Current consumption
Safety Laser Scanners
9.10 x 10-9 1/h
Multiple Light Beam Safety Devices
Probability of a failure to danger per hour (PFHd)
Safety Engineering Software
PL e
Safety Sensor Sets
General system data SIL in accordance with IEC 61508 and SILCL in accordance with IEC/EN 62061 Performance Level (PL) in accordance with EN ISO 13849-1
Machine Safety Services
Technical data
150 mA (ASM1/1, ASM1E/1), 200 mA (ASM1/2, ASM1E/2)
9600 baud, no parity, 1 start bit, 1 stop bit, 8 data bits www.leuze.com/asi/ We reserve the right to make changes • 09-01_ASM1_ASM1E.fm
AS-Interface Safety at Work
Monitor 7.F 18.5...31.6 V < 45 mA
PROFIsafe Sensors
AS-i data AS-i profile AS-i voltage range AS-i current consumption Configuration interface RS 232
Single Light Beam Safety Devices
Number of Safety Monitors per AS-Interface network 4 (with maximum 31 integrated AS-Interface slaves)
© 2010 Leuze electronic GmbH + Co. KG
319
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Page 7
AS-Interface Safety at Work Technical data Inputs and outputs Input start Input feedback circuit Signal output ("Safety on" – OSSDs active) Safety-related switching outputs (OSSDs)
Opto-coupling input (high-active), input current approx. 10 mA with 24 V DC Opto-coupling input (high-active), input current approx. 10 mA with 24 V DC pnp transistor output, 200 mA, short circuit and reverse-connect protection Up to 2 potential-free safety-related switching outputs (max. contact load: 1 A with 24 V DC, 3 A with 230 V AC)
Fuse
External with max. 4 A MT
Overvoltage category
3 (for rated operating voltage, 300 V AC in accordance with VDE 0110 Part 1)
Please note the additional information in the connecting and operating instructions at www.leuze.com/asi.
Dimensional drawings
5
104,2
81,1
102
86,4
63,2
7,2 (5x)
90,9 45
120
AS-Interface Safety at Work ASM1, ASM1E Dimensions in mm Our 3D CAD models can be found under: www.leuze.com/3d-cad-models.
Accessories ordering information See page 328.
320 We reserve the right to make changes • 09-01_ASM1_ASM1E.fm
© 2010 Leuze electronic GmbH + Co. KG
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net