For the Leuze ASM1

Page 1

AS-Interface Safety at Work Safety Monitors, ASM1, ASM1E two dependent or independent release circuits with configurable contactor monitoring are available. With an extended scope of functions, the ASM1E device type provides even more convenience with the configuration and diagnostics of a safety application monitored via an AS-Interface. Besides additional logic and diagnostics functions, ASM1E also has an activation/deactivation mode for parameterized software modules. The machine manufacturer can therefore already prepare the configuration of the Safety Monitor in the preliminary stage for all safety sensors that could be used with an extension.

AS-Interface Safety at Work-based robot application with 2 release circuits

The ASM1E-m variants are additionally equipped with an integrated Muting function package to enable a continuous material flow, e.g. for automated production cells or packaging stations, while maintaining the protective function. The Muting sensors required for this are easily integrated via standard AS-Interface input slaves; a separate Muting controller is no longer required.

Typical areas of application z Automation networks based on AS-Interface Safety at Work in the lower field level z Mixed operation of AS-i standard components and safety-related components z Packaging systems, car manufacturing, conveyor and storage systems, machine tools, processing centers and production lines

The ASM Muting functionality enables palettes in a wrapping machine application, for example, to pass by the active opto-electronic protective device without any process interruption. The AS-i Safety Monitor, the ASM1, is a core component of the AS-Interface Safety at Work system. Using configuration software it monitors the safety-related bus participants that are assigned to it, e.g. control devices, Multiple Light Beam Safety Devices and Safety Switches. The Safety Monitor has an RS 232 diagnostics interface for the PC-supported configuration and diagnostics. Logical links can be easily created with the graphic user interface of the Windows® based software. The user can combine safety sensors and control devices with a mouse click and assign different release circuits for switching off the dangerous movement. Depending on the device type,

ASKM2, p. 338

CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 2

Machine Safety

SAFETY MONITORS, ASM1, ASM1E

Machine Safety Services

Important technical data, overview

Max. 40 ms

Protection rating

IP 20

Ambient temperature, operation

-20...+60°C

Safety Laser Scanners

System response time

Features Safety Light Curtains

Dimensions (W x H x D) 45 mm x 105 mm x 120 mm

Multiple Light Beam Safety Devices

Number of Safety Monitors per 4 (with maximum 31 integrated AS-i slaves) AS-Interface network Safety-related switching Up to 2 potential-free safety-related switching outputs outputs (OSSDs) (1 A DC-13, 24 V DC / 3 A AC-15, 230 V AC)

Special features z Up to 31 safe AS-i slaves can be connected z Freely selectable assignment (Drag & Drop) of the sensor to outputz z z

Further information z Ordering information z Electrical connection z Technical data z Dimensional drawings z Accessories ordering information

Page 317 318 319 320 328 www.leuze.com/asi/

PROFIsafe Sensors

AS-Interface Safety at Work z z z side release circuits with easy to operate asimon configuration and diagnostics software 48 link modules (e.g. OR, AND, FLIPFLOP) and turn on/off delays can be configured RS 232 interface for PC-supported system configuration, system diagnostics as well as configuration data transfer to replacement device Immediate switch-off STOP 0 and delayed switch-off STOP 1 of the release circuits can be parametered SERVICE button for teach-in with sensor swap-out 2-sensor Parallel Muting or 4-sensor Sequential Muting (ASM1E) Programmable Muting logic (programmable with ASM1E-m/1 and ASM1E-m/2: Muting time extension, Muting timeout, Muting sensor signal filter, close sequence, direction change, Muting enable, Muting override mode with buttons or key switches)

Safety Sensor Sets

24 V DC, ±15%

Single Light Beam Safety Devices

Supply voltage

Safety Engineering Software

SIL in accordance with IEC 61508 and SILCL in SIL 3 accordance with IEC/EN 62061 Performance Level (PL) in accordance with PL e EN ISO 13849-1 Category in accordance 4 with EN ISO 13849 STOP category in accordance with 0 and 1 IEC/EN 60204-1

315 CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 3

AS-Interface Safety at Work Functions, ASM1, ASM1E ASM1/1

ASM1/2

ASM1E/1

ASM1E/2

Number of safety-related switching outputs (OSSDs)

1

2

1

2

Number of configurable function modules

32

32

48

48

PC configuration and diagnostics interface

RS 232

RS 232

RS 232

RS 232 z z

Monitoring modules with contact bounce filter Service button for manual error unlocking and automatic device swap-out of the safe AS-i slaves Status LED display for AS-Interface communication, OSSD, start/restart interlock, protective mode, errors z z z z z z z z

System signal output z z z z

6

6

Programmable logic operators, AND (inputs)

6

6

Programmable logic operators, FLIP-FLOP z z z z z z z z z z z z z z z z z z z z z z z z

Further functions (can be configured with asimon configuration and diagnostics software) Programmable logic operators, OR (inputs)

2

2

Programmable logic operators, switch on/off delay Programmable logic operators, system statuses z z z z z z z z z z z z z z z z z z

Programmable Muting logic STOP 0 / STOP 1 Start/restart interlock (RES), selectable Dynamic contactor monitoring (EDM), selectable Monitoring modules with contact-simultaneity monitoring Activation/deactivation of function modules Support of AS-Interface A/B technology Diagnostics data transfer via AS-Interface Error unlocking via AS-Interface

316 We reserve the right to make changes • 09-01_ASM1_ASM1E.fm

© 2010 Leuze electronic GmbH + Co. KG

CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 4

Functions: Monitoring the AS-Interface Safety at Work bus participants, with selectable start/restart interlock, contactor monitoring, STOP 0/STOP 1, PC diagnostics interface

Article

Description

Safety-related switching outputs (OSSDs)

580020

ASM1/1

AS-i Safety Monitor

1 release circuit

580024

ASM1E/1

AS-i Safety Monitor, extended

1 release circuit

580021

ASM1/2

AS-i Safety Monitor

2 release circuits

580025

ASM1E/2

AS-i Safety Monitor, extended

2 release circuits

580055

ASM1E-m/1

AS-i Safety Monitor, extended, Muting

1 release circuit

580056

ASM1E-m/2

AS-i Safety Monitor, extended, Muting

2 release circuits

Machine Safety PROFIsafe Sensors

AS-Interface Safety at Work

Single Light Beam Safety Devices

Safety Sensor Sets

Multiple Light Beam Safety Devices

Safety Light Curtains

Art. no.

Safety Engineering Software

ASM1 and ASM1E Included in delivery: Device front screen for protection and sealing; connecting and operating instructions (short version)

Safety Laser Scanners

Ordering information

Machine Safety Services

SAFETY MONITORS, ASM1, ASM1E www.leuze.com/asi/ We reserve the right to make changes • 09-01_ASM1_ASM1E.fm

© 2010 Leuze electronic GmbH + Co. KG

317

CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 5

AS-Interface Safety at Work Electrical connection ASM1 connection example

+ 24V

+ 24V

AS-i+

AS-i+

AS-i-

AS-i-

-S1

-K1

L+

L+

1

1

2

2

1.13

1.23

1.14

1.24

-K2 AS-i+ 1

AS-i3

4

AS-i+ 1

AS-i3

-A3

L+

4

1.Y2

AS-i+

AS-i-

1.Y1

CPT/A

ASM 1/ 1

0V

CPR/A

-A2

+ 24V

-A1

2

5

2

5

M

FE

1.32

Var. B Var. A

-K1

A1

-K1 -K1

-K2 -K2

A1

-K2 A2

A2

L-

L- x1 x2

0V PE

0V PE

ASM1 Safety Monitor with COMPACTplus Safety Light Curtain with integrated AS-Interface Please observe the operating instructions of the components!

318 We reserve the right to make changes • 09-01_ASM1_ASM1E.fm

© 2010 Leuze electronic GmbH + Co. KG

CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 6

Machine Safety

SAFETY MONITORS, ASM1, ASM1E

SIL 3

Service life (TM ) in accordance with EN ISO 13849-1

20 years With DC1 (ohmic load) With AC1 (ohmic load)

Number of cycles until 10 % of the components have With DC13 (inductive load) a failure to danger (B10d) With AC15 (inductive load) Low load (20% nominal load)

10,000,000 (I < 2 A, 24 V) 100,000 (2 A, 230 V) 250,000 (1 A, 230 V) 540,000 (0.5 A, 230 V) On request

4

Safety Light Curtains

Category in accordance with EN ISO 13849

On request

STOP category in accordance with IEC/EN 60204-1 0 and 1 Supply voltage System response time (exclusive sensor response time) Readiness delay

24 V DC, ±15% Max. 40 ms

Ambient temperature, operation Ambient temperature, storage

Max. 10 s IP 20 (only suitable for use in electrical operating rooms/cabinets with IP 54 minimum protection rating) -20...+60°C -30... +70°C

Dimensions (W x H x D)

45 mm x 105 mm x 120 mm

Housing material Mounting

Polyamide PA 66 Snap-on fastening on DIN rails in accordance with EN 50022 1x 0.5 to 4.0 mm2 and 2x 0.5 to 2.5 mm2 (single-wired) 1x 0.5 to 2.5 mm2 and 2x 0.5 to 1.5 mm2 (multi-wire) 2x 20 to 14 (AWG)

Protection rating

Connection system Current consumption

Safety Laser Scanners

9.10 x 10-9 1/h

Multiple Light Beam Safety Devices

Probability of a failure to danger per hour (PFHd)

Safety Engineering Software

PL e

Safety Sensor Sets

General system data SIL in accordance with IEC 61508 and SILCL in accordance with IEC/EN 62061 Performance Level (PL) in accordance with EN ISO 13849-1

Machine Safety Services

Technical data

150 mA (ASM1/1, ASM1E/1), 200 mA (ASM1/2, ASM1E/2)

9600 baud, no parity, 1 start bit, 1 stop bit, 8 data bits www.leuze.com/asi/ We reserve the right to make changes • 09-01_ASM1_ASM1E.fm

AS-Interface Safety at Work

Monitor 7.F 18.5...31.6 V < 45 mA

PROFIsafe Sensors

AS-i data AS-i profile AS-i voltage range AS-i current consumption Configuration interface RS 232

Single Light Beam Safety Devices

Number of Safety Monitors per AS-Interface network 4 (with maximum 31 integrated AS-Interface slaves)

© 2010 Leuze electronic GmbH + Co. KG

319

CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 7

AS-Interface Safety at Work Technical data Inputs and outputs Input start Input feedback circuit Signal output ("Safety on" – OSSDs active) Safety-related switching outputs (OSSDs)

Opto-coupling input (high-active), input current approx. 10 mA with 24 V DC Opto-coupling input (high-active), input current approx. 10 mA with 24 V DC pnp transistor output, 200 mA, short circuit and reverse-connect protection Up to 2 potential-free safety-related switching outputs (max. contact load: 1 A with 24 V DC, 3 A with 230 V AC)

Fuse

External with max. 4 A MT

Overvoltage category

3 (for rated operating voltage, 300 V AC in accordance with VDE 0110 Part 1)

Please note the additional information in the connecting and operating instructions at www.leuze.com/asi.

Dimensional drawings

5

104,2

81,1

102

86,4

63,2

7,2 (5x)

90,9 45

120

AS-Interface Safety at Work ASM1, ASM1E Dimensions in mm Our 3D CAD models can be found under: www.leuze.com/3d-cad-models.

Accessories ordering information See page 328.

320 We reserve the right to make changes • 09-01_ASM1_ASM1E.fm

© 2010 Leuze electronic GmbH + Co. KG

CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net