The text of a manual · part 25 of 29
AnS(H) CPU User's Manual: APPENDICES, pages 197 to 206
Pages 197 to 206 of 242, from AnS(H) CPU User's Manual
The original document is the PDF (3.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Mitsubishi A1S38
Page 197
APPENDICES Execution Conditions
MELSEC-A When the LEDA instruction is used, the RDGET instruction is executed every scan while the read command is ON. When the LEDB instruction is used, the RDGET instruction is executed only one scan on the leading edge (OFF → ON) of the read command. Note that several scans will be required until the completion of read processing by the RDGET instruction. Therefore, execute the next RDGET instruction after the completion device has switched on. (The RDGET instruction executed before the completion of RDGET instruction execution is ignored.) END processing
END processing
END processing
END processing
Sequence program flow RDGET instruction execution complete
Executed RDGET instruction
ON Completion device
OFF ON
On-completion status display device
OFF
Abnormal completion Normal completion
1 scan During processing of RDGET instruction
Operation Error
Data can be read by RDGET instruction.
The following condition will result in an operation error and the error flag (M9011) switch on. Description
Error code
The number of read points specified at D1 +3 is outside the range 0 to 480.
Program Example
D9008
D9092
50
503
The following program reads 1 point of data from the remote device station having station number 1 and connected to the master module of CC-Link allocated to I/O numbers 000 to 01F. This program assumes that control data are stored in D1000-D1003. 0
X0020
LEDA RDGET SUB
K 0
SUB
K 1
LEDC
D1000
LEDC
L1000
RDGET instruction designation
LEDR CIRCUIT END
APP - 41
Page 198
MEMO
APP - 42
Page 199
APPENDICES
X
Y
M
L
S
B
F
T
C
D W R A0 A1 Z
V
Constant
Pointer Levle
K
P
H
I
N
Index
Word device
Subset
Available device Bit device
Number of steps
Write to remote device station ................... RDPUT Digit designation
1.1.11
MELSEC-A
Carry flag
Error flag
M9012
M9011 n1 n2
26
D1 D2
Command LEDA/LEDB
RDPUT
SUB n1
SUB n2
LEDC
D1
LEDC
D2
LEDA·······Executed while ON LEDB·······Executed at leading edge LEDC······ Device number designated SUB·········Constant designated
LEDR
Control Data
(1)
n1
Head I/O number of object master module n2
Remote device station number : 1 to 64
D1
Device for storing control data and written data
D2
Bit device number which is switched on on completion of execution
Control data setting items D1 +0
RWw1
RY
D1 +1
RWr2
RX
D1 +2
Set value
D1 +3
Number of points written
D1 +4 to
Written data storage area
D1 +n
(2)
Data to be set
Control data
Stores data written to remote device station on completion of RDPUT instruction execution. [Number of points specified at D1 +3]
Control data settings Item
Set data
Setting range
Setting end
RY
Write request
0 to 127
User *
2
RWw
Write request
0 to 15
User *
2
RX
Write completion
0 to 127
User *
2
RWr
Write completion
0 to 15
User *
2
Set value
Specify the writing set value allocated to the remote device station
*1
User
Number of points written
Specify the number of data written (word basis).
1 to 16
User
POINTS (1) *1 : Refer to the manual of the remote device station to which data is written. (2) *2 : The RY, RWw, RX and RWr numbers used are set by the user. Note that RY and RX ON/OFF control and RWw and RWr data setting are performed by the system. The user cannot perform RY and RX ON/OFF control and RWw and RWr data setting.
APP - 43
Page 200
APPENDICES
MELSEC-A
Functions
(1)
Writes the points of data specified at D1 +3 stored from the devices beginning with the one specified at D1 +4 using RX and RY specified at D1 +0-1 to the link registers in the remote device station having the station number specified at n2 and connected to the master module specified at n1 . On completion of writing, the bit device specified at D2 switches on only one scan. On abnormal completion, the bit device at D2 +1 switches on only one scan. RDPUT instruction execution range
AnSHCPU
Remote device station
Master station n1 n2
RDPUT instruction
Write
Remote registers
Specified device
Execution Conditions
(2)
The RDPUT instruction may be executed for two or more remote device stations at the same time. However, this instruction cannot be executed for the same remote device station in two or more locations at the same time.
(3)
As control data, specify the values given in the manual of the remote device station. If wrong setting is made, the instruction will not be completed.
When the LEDA instruction is used, the RDPUT instruction is executed every scan while the write command is ON. When the LEDB instruction is used, the RDPUT instruction is executed only one scan on the leading edge (OFF → ON) of the write command. Note that several scans will be required until the completion of write processing by the RDPUT instruction. Therefore, execute the next RDPUT instruction after the completion device has switched on. (The RDPUT instruction executed before the completion of RDPUT instruction execution is ignored.)
APP - 44
Page 201
APPENDICES
MELSEC-A END processing
END processing
END processing
END processing
Sequence program flow RDPUT instruction execution complete
Executed RDPUT instruction
ON Completion device
OFF ON
On-completion status display device
OFF
Abnormal completion Normal completion
1 scan During processing of RDPUT instruction
Program Example
Data can be written by RDPUT instruction.
The following program writes 1 point of data to the remote device station having station number 1 and connected to the master module of CC-Link allocated to I/O numbers 000 to 01F. This program assumes that control data and written data are stored in D1000-D1004. 0
X0020
LEDA RDPUT SUB
H 0000
SUB
K 1
LEDC
D1000
LEDC
L1000
RDPUT instruction designation
LEDR CIRCUIT END
APP - 45
Page 202
MEMO
APP - 46
Page 203
APPENDICES
X
Y
M
L
S
B
F
T
C
D W R A0 A1 Z
V
Constant
Pointer Levle
K
P
H
I
N
Index
Word device
Subset
Available device Bit device
Number of steps
Monitoring of remote device station ....................RDMON Digit designation
1.1.12
MELSEC-A
Carry flag
Error flag
M9012
M9011 n1 n2
26
D1 D2
Command LEDA/LEDB
RDMON
SUB n1
SUB n2
LEDC
D1
LEDC
D2
LEDA·······Executed while ON LEDB·······Executed at leading edge LEDC······ Device number designated SUB·········Constant designated
LEDR
Control Data
(1)
n1
Head I/O number of object master/local module n2
Remote device station number : 1 to 64
D1
Device for storing control data and read data
D2
Bit device number which is switched on on completion of execution
Control data setting items D1 +0
RWw1
RY1
D1 +1
RX1 Set value
D1 +2 D1 +3
RWw2
D1 +4
RWr2
RY2
Set value
D1 +6
Number of points monitored to
Control data
RX2
D1 +5
D1 +7
Monitor data
D1 +n
(2)
Data to be set
Stores monitor data read from remote device station on completion of RDMON instruction execution. [Number of points specified at D1 +6]
Number of control data area points Monitor data read from a remote device station is stored into the area after the 7 points of control data [ D1 +0 to D1 +6]. Reserve the control data area for 7 points + [number of points specified at D1 +6] successively.
APP - 47
Page 204
APPENDICES
MELSEC-A 3)
Control data settings Item
Set data
RY1 RWw1 RX1
Setting range
Monitoring registration request
0 to 127 *
Monitoring registration request
1
RWw2 RX2
1
User *
2
User *
2
0 to 127 *
1
User *
2
Monitoring execution request
0 to 127 *
1
User *
2
Monitoring execution request
1
User *
2
User *
2
User *
2
0 to 15 *
Monitoring registration completion
RY2
Setting end
0 to 15 *
Monitoring completion
0 to 127 *
RWr2
Monitoring completion
1
Set value
Specify the monitoring set value allocated to the remote device station.
Number of points monitored
Specify the number of data monitored (word basis).
0 to 15 *
1
*1
User
1 to 16
User
POINTS (1) *1 : Refer to the manual of the remote device station from which data is monitored. (2) *2 : The RY1/2, RWw1/2, RX1/2 and RWr2 numbers used are set by the user. Note that RY1/2 and RX1/2 ON/OFF control and RWw1/2 and RWr2 data setting are performed by the system. If the user performs RY1/2 and RX1/2 ON/OFF control and RWw1/2 and RWr2 data setting, the RDMON instruction will not be completed properly. Functions
(1)
Registers monitoring of the remote device station having the station number specified at n2 and connected to the master module specified at n1 , and stores the points of monitor data specified at D1 +6 into the devices starting from the one specified at D1 +7. On completion of monitor data reading, the bit device specified at D2 switches on only one scan. On abnormal completion, the bit device at D2 +1 switches on only one scan. RDMON instruction execution range
AnSHCPU
Master module n1
Remote device station n2
Monitoring request
RDMON instruction
Monitor data D1 +7
Specified device
(2)
D1 +6
The RDMON instruction may be executed for two or more remote device stations at the same time. However, this instruction cannot be executed for the same remote device station in two or more locations at the same time.
APP - 48
Page 205
APPENDICES Execution Conditions
MELSEC-A When the LEDA instruction is used, the RDMON instruction is executed every scan while the read command is ON. When the LEDB instruction is used, the RDMON instruction is executed only one scan on the leading edge (OFF → ON) of the read command. Note that several scans will be required until the completion of read processing by the RDMON instruction. Therefore, execute the next RDMON instruction after the completion device has switched on. (The RDMON instruction executed before the completion of RDMON instruction execution is ignored.) END processing
END processing
END processing
END processing
Sequence program flow RDMON instruction execution complete
Executed RDMON instruction
ON Completion device
OFF ON
On-completion status display device
OFF
Abnormal completion Normal completion
1 scan During processing of RDMON instruction
Operation Error
Data can be read by RDMON instruction.
The following condition will result in an operation error and the error flag (M9011) switches on. Description
Error code
The number of read points specified at D1 +3 is outside the range 0 to 480.
Program Example
D9008
D9092
50
503
The following program monitors 1 point from the remote device station having station number 1 and connected to the master module of CC-Link allocated to I/O numbers 000 to 01F. This program assumes that control data are stored in D1000-D1006. 0
X0020
LEDA RDMON SUB
H 0000
SUB
K 1
LEDC
D1000
LEDC
L1000
RDMON instruction designation
LEDR CIRCUIT END
APP - 49
Page 206
APPENDICES
MELSEC-A
Appendix 1.2 Caution when Performing a Write while Running Dedicated Instruction Description of write performed when running.
For LEDA
For LEDB
Normal configuration is written when running.
After write, the previous contact turns on and the instruction is executed.
After write, the instruction is executed when the previous contact is turned from OFF to ON.
LEDA/LEDB was added by mistake.
Error 104 occurs (incorrect configuration).
If the previous contact stays after write, the instruction is not executed, so no process is performed. When the previous contact is turned from OFF to ON, error 104 results.
LEDA/LEDB was deleted by mistake.
The LEDC/SUB/LEDR is processed as a regular instruction.
Same as stated on left.
Error 104 occurs (incorrect configuration).
If the previous contact stays after write, the instruction is not executed, so no process is performed. When the previous contact is turned from OFF to ON, error 104 results.
LEDC/SUB was deleted by mistake.
Error 104 occurs (incorrect configuration).
If the previous contact stays after write, the instruction is not executed, so no process is performed. When the previous contact is turned from OFF to ON, error 104 results.
LEDR was added by mistake.
The latter LEDR is processed as a regular instruction.
The latter LEDR is processed as a regular instruction.
LEDR was deleted by mistake.
Error 104 occurs if LEDR does not exist directly after the deleted LEDR.
Error 104 occurs if LEDR does not exist directly after the deleted LEDR. If LEDR exists, all instructions in between are not executed.
LEDC/SUB was added by mistake.
APP - 50