2. SYSTEM CONFIGURATION

Item

Model

A77GOT-S5

Graphic operation terminal

A850GOT

MELSEC-A

Description

Large graphic operation terminal monitor screen included model (black and white LCD, color LCD, EL) 250 monitor screens, 255 parts

Mid-size graphic operation terminal monitor included model (black and white LCD, STN color LCD) Base/window screen : 1024 pixels

Number of inputs/outputs

Current consumption

[I/O allocation module type]

5 V DC, - 24 V DC, - - 0.5 (when connecting MELSECNET: 0.7)

A851GOT A870GOT

A810GOT

Main base unit

Extension base unit

0.5 Large graphic operation terminal monitor screen included model (STN/TFT color EL) Base/window screen : 1024 pixels Large graphic operation terminal CRT connection model for monitor Base/window screen : 1024 pixels

A1S32B A1S33B A1S35B

Up to two I/O modules can be loaded. Up to three I/O modules can be loaded. Up to five I/O modules can be loaded.

A1S38B

Up to eight I/O modules can be loaded.

A1S52B(S1) A1S55B(S1)

Up to two I/O modules can be loaded. Up to five I/O modules can be loaded.

A1S58B(S1)

Up to eight I/O modules can be loaded.

A1S65B(S1)

Up to five I/O modules can be loaded.

A1S68B(S1)

Up to eight I/O modules can be loaded.

A1SC01B

0.055 m (2.17 in.) long flat cable, - A1SC03B A1SC07B Extension A1SC12B cable A1SC30B A1SC60B A1SC05NB A1SC07NB A1SC30NB A1SC07NB

0.33 m (11.8 in.) long 0.7 m (27.6 in.) long 1.2 m (47.24 in.) long 3 m (118.11 in.) long 6 m (236.22 in.) long 0.45 m (17.72 in.) long 0.7 m (27.6 in.) long 4.3 m (118.11 in.) long 5 m (196.85 in.) long, - - - - - - When connected via bus, 32 special points are occupied. When connected via bus, 32 special points are occupied. Consumed power: 100 VA Equipped with two extension connectors: one is on the right; the other on the left side Power supply module cannot be loaded (power is supplied from the main base unit)., - - - - - For extension on the right side Extension base unit connection cable, - - - - - - - - - - - * Approved standard

When connected via bus, 32 special points are occupied. Consumed power : 100 VA

Needs a power supply module.

* : Class 2 power supply recognized by the UL/cUL Standard is required for 5-12-24 V DC modules.

2 - 15

Remarks

A[ ]N, A[ ]A extension base cable

UL/cUL

Page 32

2. SYSTEM CONFIGURATION

Item

Model

MELSEC-A

Description

Applicable model

A1SMCA8KP A1SNMCA8KP A1SMCA2KE A1SMCA8KE A1SNMCA2KE A1SNMCA8KE

8 k steps, equipped with EPROM (directly) 8 k steps, equipped with EPROM (directly) 2 2 k steps, equipped with E PROM (directly) 2 8 k steps, equipped with E PROM (directly) 2 2 k steps, equipped with E PROM (directly) 2 8 k steps, equipped with E PROM (directly)

A2SNMCA30KE

14 k steps, equipped with E PROM (directly)

Memory write adapter

A6WA-28P

Used for memory cassette connector/EPROM 28-pin

Battery

A6BAT

EPROM

Memory cassette 2

E PROM

2

For A1SJHCPU : A6WA-28P required For A1SJH/A1SHCPU : A6WA-28P required For A1SJHCPU Writing/reading directly from the peripheral device is possible UL/cUL For A1SJH/A1SHCPU Writing/reading directly from the peripheral device is possible For A2SHCPU Writing/reading directly from the peripheral device is possible For A1SMCA-8KP Used to partition ROM in A1SMCA8KP Mounted in A1SCPU/A2SCPU body

Cable for connector/terminal block conversion module

AC05TB AC10TB AC20TB AC30TB AC50TB AC05TB-E AC10TB-E AC20TB-E AC30TB-E AC50TB-E

IC-RAM battery backup For sink type input module and sink type output module (standard type) For sink type input module and sink type output module (2-wire type) For sink type input module (3-wire type) For source type input module (standard type) For source type output module (standard type) For source type input module (2-wire type) For source type output module (2-wire type) For source type input module (3-wire type) 0.5 m (1.64 ft) for source module 1 m (3.28 ft) for source module 2 m (6.56 ft) for source module 3 m (9.84 ft) for source module 5 m (16.4 ft) for source module 0.5 m (1.64 ft) for source module 1 m (3.28 ft) for source module 2 m (6.56 ft) for source module 3 m (9.84 ft) for source module 5 m (16.4 ft) for source module

Relay terminal module

A6TE2-16SR

For sink type output module

A1SY41, A1SY42, A1SH42, AY42, AY42-S1, AY42-S3, AY42-S4, AH42

Cable for connecting relay terminal module

AC06TE AC10TE AC30TE AC50TE AC100TE

0.6 m (1.97 ft) long 1 m (3.28 ft) long 3 m (9.84 ft) long 5 m (16.4 ft) long 10 m (32.8 ft) long

A6TE2-16SR

A6TBXY36 A6TBXY54 Connector/terminal block conversion module

A6TBX70 A6TBX36-E A6TBY36-E A6TBX54-E A6TBY54-E A6TBX70-E

AnS I/O module and special module terminal block cover

A1STEC-S

Slim-type terminal block cover for the AnS I/O module and special module (terminal block connector type)

A1SX41(S2), A1SX42(S2), A1SY41, A1SY42, A1SH42, AX42(S1), AY42(S1/S3/S4), AH42 A1SX41(S2), A1SX42(S2), A1SH42, AX42(S1), AH42 A1SX81(S2), AX82 A1SY81, AY82EP A1SX81(S2), AX82 A1SY81, AY82EP A1SX81(S2), AX82

A6TBXY36, A6TBXY54, A6TBX70

A6TBX36-E, A6TBY36-E, A6TBX54-E, A6TBY54-E, A6TBX70-E

A1SX10, A1SX10EU, A1SX20, A1SX20EU, A1SX30, A1SX40 (S1/S2), A1SX80 (S1/S2), A1SY10, A1SY10EU, A1SY14EU, A1SY18A, A1SY18AEU, A1SY22, A1SY28A, A1SY28EU, A1SY40, A1SY50, A1SY60 (E), A1SY68A, A1SY80, A1SX48Y18, A1SX48Y58, A1SI61, A1S64AD, A1S62DA,A1S63ADA, A1S62RD3/4, A1SD61, A1SP60

* : Class 2 power supply recognized by the UL/cUL Standard is required for 5-12-24 V DC modules.

2 - 16

* Approved standard

Page 33

2. SYSTEM CONFIGURATION

MELSEC-A

REMARK I/O cables with connectors for I/O modules with 40-pin connector specifications (A1SX41, A1SX42, A1SY41, A1SY42, etc.) or 37-pin D-sub connector specifications (A1SX81, A1SY81, A1SY81EP) are available. Consult your nearest Mitsubishi representative for I/O cables with connectors.

(2)

A[ ]NA[ ]A extension base unit The following table shows the modules that can be loaded to the A[ ]NA [ ]A extension base units : A65B; A68B; A55B; or A58B. For details on the specifications of each module see the appropriate module manual.

POINT (1)

All A[ ]NA[ ]A "building block type I/O modules" are compatible with the AnSHCPU.

Item

Model

Single-axis positioning module

AD70, AD70D

Positioning module

AD71, AD71S1, AD72

Position detection module

A61LS, A62LS

High speed counter module

AD61, AD61S1

A-D converter module

A68AD, A68ADS2, A616AD, A60MX, A60MXR, A68ADN

Temperature input module

A616TD, A60MXT

D-A converter module

A62DA, A62DAS1, A616DAI, A616DAV, A68DAV, A68DAI

A-D/D-A converter module

A84AD

CRT control/LCD control module

AD57, AD57S1, AD58

Graphic controller module

AD57G, AD57GS3

Memory card, parrallel interface module

AD59, AD59S1

Voice output module

A11VC

Computer link module

AJ71C24(S3/S6/S8), AJ71UC24

Intelligent communication module

AD51E, AD51ES3, AD51H(S3)

Terminal interface module

AJ71C21, AJ71C21S1

MELSECNET/MINI (S3) data link module

AJ71PT32, AJ71PT32-S3

Data link module

AJ71AP21, AJ71AR21, AJ71AT21B

SUMINET interface module

AJ71P41

Ethernet interface module

AJ71E71

2 - 17

Page 34

2. SYSTEM CONFIGURATION

MELSEC-A

Item

Model

Multidrop data link module

AJ71C22

Interrupt module

AI61

Power supply module

A61P, A62P, A63P, A65P, A66P, A67P, A68P, A61PEU, A62PEU

Extension base unite

A62B, A65B, A68B, A52B, A55B, A58B

(3)

Peripheral devices Item

Module

Plasma handy graphic programmer

A6PHP-SET

Intelligent GPP

A6GPP-SET

Composite video cable RS-422 cable

User disk

Cleaning disk

AC10MD

RS-422 cable

• Connects A6GPP and monitor display. (1 m (3.28 ft) long)

AC30R4

3 m (9.84 ft) long 30 m (98.4 ft) long

SW0-GPPU

2DD

SW0S-USER

2HD

SW0-FDC

Applicable to A6GPP/A6PHP

Connects CPU and A6GPP/A6PHP. Used for storing user program (3.5 in., formatted) Used for cleaning disk drive.

A7PU

• Connected directly to the CPU with an RS-422 cable (AC30R4, AC300R4) to read and write programs. Provided with an MT function. • The product package includes a cable used for connection to an audio cassette recorder.

A7PUS

Connected directly to the CPU with an RS-422 cable (AC30R4-PUS) to read and write programs.

A8PUE

Connected directly to the CPU with an RS-422 cable (AC30R4-PUS, AC20R4-A8PU) to read and write programs.

AC30R4, AC300R4,

P-ROM writer module

A6PHP SW[ ]GP-GPPAEE : A-series GPP function system disk SW[ ]GP-GPPKEE : K-series GPP function system disk SW0-GPPU : User disk (2DD) AC30R4 : RS-422 cable (3 m (9.84 ft) long) A6GPP SW[ ]GP-HGPAEE : A-series GPP function system disk SW[ ]GP-HGPKEE : K-series GPP function system disk SW0-GPPU : User disk (2DD) AC30R4 : RS-422 cable (3 m (9.84 ft) long)

AC300R4

Programming module

RS-422 cable

Remarks • • • • • • • • • •

Used to connect an A7PU to the CPU. Long : 3 m/30 m (9.84 ft./98.4 ft.)

AC30R4-PUS

Used to connect an A7PUS or A8PUE to the CPU. Long : 3 m (9.84 ft.)

AC20R4-A8PU

Used to connect an A8PUE to the CPU. Long : 2 m (6.56 ft.)

• Used for writing a program in the CPU/A6PHP to ROM, or for reading A6WU AC30R4, AC300R4 AC03WU

2 - 18 a CPU program from ROM.

• Connected to CPU/A6PHP using an AC30R4/AC03WU cable. Connects CPU and A6WU. 3 m/30 m (9.84 ft/98.4 ft) long Connects A6PHP and A6WU. 0.3 m (0.98 ft) long

Page 35

2. SYSTEM CONFIGURATION

MELSEC-A

POINTS (1)

Programming devices compatible with A1SHCPU A6WU P-ROM writer module cannot be used. All programming devices compatible with A1SHCPU can be used, excluding A6WU. (When A7PU, A7PUS, A8PU or A8PUE is used, the CPU type "A3" is displayed when started up.)

(2)

Software packages compatible with A1SHCPU All utility packages compatible with A1SHCPU can be used.

2 - 19

Page 36

2. SYSTEM CONFIGURATION 2.4 2.4.1

MELSEC-A

General Description of System Configuration AnSHCPU The following gives the system configuration, number of inputs/outputs, I/O number allocation, etc. when the AnSHCPU is used as an independent system.

1st extension stage UNIT 1 2 3

1 2 3

System configuration

UNIT 1 2 3

1 2 3

1 2 3

Slot number to to to to to to to to 0F 1F 2F 3F 4F 5F 6F 7F to to to to to to to

8F 9F AF BF CF DF EF FF Extension base unit (A1S55B-S1) 16 17 18 19 20 (21) (22) (23) 100 110 120 130 140 150 160 170 to to to to to to to

10F 11F 12F 13F 14F 15F 16F 17F

Extension base unit (A1S68B-S1) 24 25 26 27 28 29 30 31 Power supply module

UNIT 1 2 3

7

80 90 A0 B0 C0 D0 E0 F0 to 3rd extension stage

6

Extension base unit (A1S58B-S1) 8 9 10 11 12 13 14 15 to

2nd extension stage

5

00 10 20 30 40 50 60 70

CPU

Extension cable

Power supply module

Main base unit (A1S38B) 0 1 2 3 4

180 190 1A0 1B0 1C0 1D0 1E0 1F0 to to to to to to to to

18F 19F 1AF 1BF 1CF 1DF 1EF 1FF

Maximum number of extension stages

Three

Maximum number of input/output points

A1SHCPU : 256 points, A2SHCPU : 512 points, A2SHCPU-S1 : 1024 points

Main base units

A1S32B, A1S33B, A1S35B, A1S38B

Extension base units

A1S52B(S1), A1S55B(S1), A1S58B(S1), A1S65B(S1), A1S68B(S1), A52B, A55B, A58B, A62B, A65B, A68B

Extension cables

Notes

I/O number allocation

A1SC01B, A1SC03B, A1SC07B, A1SC12B, A1SC30B, A1SC60B, AC06B, AC12B, AC30B, A1SC05NB, A1SC07NB (1) Only the 1st extension base unit can be used when extension base units of types other than the AnS S1 are equipped. (The S1 type and other types must not be used together.) (2) To use the AnS S1 type extension base unit with an A[ ]N or A[ ]A type, the latter must be equipped with the last extension base unit. (The A[ ]N or A[ ]A extension base unit cannot be connected to the AnS S1 type.) (3) When an A1S52B (S1), A1S55B (S1), A1S58B (S1), A52B, A55B, or A58B is used, a voltage of 5 V DC is supplied from the power supply module. See Section 7.1.3, and consider the application. (4) The extension cable should be used for distances of up to 6 m (19.68 ft.). (5) The extension cable must not be bundled with or laid near the main circuit (high voltage, high current) lines. (1) Allocate I/O numbers to the extension base units in order of extension base unit number, not in extension cable connection order. (2) I/O numbers are allocated on the assumption that both the main base unit and the extension base units have eight slots. Sixteen input/output points will be allocated to each slot indicated by dotted lines in the above system configuration figure. (3) Allocate 16 input/output points to empty slots. (4) If the setting of an extension base unit has been omitted, make the allocation on the assumption that each of the eight slots of the relevant base unit occupies 16 input/output points. (5) Items (2) to (4) can be changed by performing "I/O allocation". For details, see the ACPU Programming Manual (Fundamentals).

2 - 20

Page 37

2. SYSTEM CONFIGURATION 2.4.2

MELSEC-A

A1SJHCPU This section describes the system configuration, numbers of I/O points, I/O allocations, etc., for a stand-alone A1SJHCPU system. 0

Extension cable

1st extension base unit UNIT 1 2 3

System configuration

1 2 3

1

2

3

4

5

6

7

Slot number

00 10 20 30 40 50 60 70 to to to to to to to to 0F 1F 2F 3F 4F 5F 6F 7F

A1SJHCPU

Extension base unit (A1S58B-S1) 8

9

10 11 12 13 14 15

80 90 A0 B0 C0 D0 E0 F0 to to to to to to to to 8F 9F AF BF CF DF EF FF

To 2nd and 3rd extension base units (Can be used by allocating I/O points.)

To 2nd and 3rd extension base units (Can be used by allocating I/O points.) *In this example, a 16-point module is installed at each slot.

Maximum number of extension stages

Three

Maximum number of input/output points

256

Extension base units

A1S52B(S1), A1S55B(S1), A1S58B(S1), A1S65B(S1), A1S68B(S1), A52B, A55B, A58B, A62B, A65B, A68B

Extension cables

Notes

I/O number allocation

A1SC03B, A1SC07B, A1SC12B, A1SC30B, A1SC60B, A1SC01B, AC06B, AC12B, AC30B, A1SC05NB, A1SC07NB (1) If using a type of extension base unit for A1S use other than the S1 type,, only one extension base unit can be installed. (Combined use of S1 type extension base units and extension base units other than the S1 type is not possible.) (2) When using one or more S1 type extension base units for A1S use in combination with one or more extension base units for A[ ]N or A[ ]A use, the final extension base unit must be one for A[ ]N or A[ ]A use. (An S1 type extension base for A1S use can not be connected from an extension base for A[ ]N or A[ ]A use.) (3) Extension base units A1S52B(S1), A1S55B(S1), A1S58B(S1), A52B, A55B, A58B are supplied with a 5 V DC power supply from the power supply module on the main base unit; see Section 7.1.3 to determine whether or not these extension base units can be used. (4) The total length of extension cable used must not exceed 6 m (19.68 ft.). (1) I/O numbers are allocated in the order of the numbers set in extension base number setting, regardless of the order of connection of extension cables. (2) When allocating I/O points, all main bases and extension bases are regarded as having 8 slots of I/O points. Accordingly, 16 points per slot are allocated to the part of the system configuration drawing indicated using dotted lines. (3) 16 points are allocated to vacant slots. (4) If extension base number setting has not been performed at one or more modules, I/O points are allocated by regarding each slot in the total number of slots involvedobtained by multiplying the number of extension bases for which setting was skipped by 8 slots-as occupying 16 points per slot. (5) The allocations in (2) to (4) above can be changed by performing "I/O allocation". When using two or three extension base units, perform "I/O allocation" to allocate 0 points to vacant slots of the A1SJCPU and some slots of the first extension base unit, and allocate I/O points to the second and third extension base units. (The total number of I/O points for the A1SJCPU and 1st, 2nd, and 3rd extension base units is 256.) For details on "I/O allocation", see the ACPU Programming Manual(Fundamentals).

2 - 21