Page 273
FX3G Series Programmable Controllers
19 Display Module(FX3G-5DM)
User's Manual - Hardware Edition
19.1 Specifications
11 High-Speed Counters
19. Display Module(FX3G-5DM)
12
•
Before modifying or disrupting the program in operation or running the PLC, carefully read through this manual and the associated manuals and ensure the safety of the operation. An operation error may damage the machinery or cause accidents.
•
•
Do not disassemble or modify the PLC. Doing so may cause fire, equipment failures, or malfunctions. For repair, contact your local Mitsubishi Electric distributor. Turn off the power to the PLC before attaching or detaching the following devices. Failure to do so may cause equipment failures or malfunctions. - Display module, peripheral devices, expansion boards, and special adapters - Connector conversion adapter, extension blocks, and FX Series terminal blocks - Battery and memory cassette
14 Test Run, Maintenance, Troubleshooting
19.1
Specifications
15 Input/Output Powered Extension Units
19.1.1 Applicable PLC Model name FX3G Series
Applicability
16
Ver.1.10 or later
Input/Output Extension Blocks
19.1.2 Display/switch specifications Item Display device
17
Green LED backlight 16 letters (half-width character)
4 lines
Characters
Alphabets, Numbers, Japanese character
Language for menu display
English/Japanese
Extension Power Supply Unit
Number of letters
Button
Specifications STN monochrome liquid crystal display
Backlight Displaed letters
13 Wiring for Various Uses
STARTUP AND MAINTENANCE PRECAUTIONS
Output Wiring
STARTUP AND MAINTENANCE PRECAUTIONS
4 operation buttons (OK, ESC, +, and -)
18 Other Extension Units and Options
19 Display Module
20 Terminal Block
267
Page 274
FX3G Series Programmable Controllers
19 Display Module(FX3G-5DM)
User's Manual - Hardware Edition
19.1 Specifications
19.1.3 Part Names Liquid crystal screen "ESC" button "-" button "+" button "OK" button Cut off the part when using an expansion board at the same time.
Functions of operation buttons The display module has 4 operation buttons as shown in the following table. Name of button ESC
Function of operation button Use this button to cancel the operation and to return to the previous screen.
-
Use this button to move the cursor or to set a numeric value.
+
Use this button to move the cursor or to set a numeric value.
OK
Use this button to select an item or to determine the set numeric value.
19.1.4 External Dimensions
34.4(1.36") 49.4(1.95")
51.2(2.02")
Unit: mm(inches)
9.6(0.38") 12(0.48")
268
Page 275
FX3G Series Programmable Controllers
19 Display Module(FX3G-5DM)
User's Manual - Hardware Edition
11
Installation and Removal
High-Speed Counters
19.2
19.2 Installation and Removal
Be sure that the power is OFF when installing the display module.
The FX3G-40MT/ES is used as the main unit in this example.
1 Remove the top cover.
13 Wiring for Various Uses
Remove the top cover (A in the figure on the right) as shown in the right figure.
A
12 Output Wiring
19.2.1 Installation (when the expansion board/connector conversion adapter is not used together)
Top cover(S) 1
Caution: Display module cannot attach in the top cover(S) side of a 40/60point types main unit.
14 Test Run, Maintenance, Troubleshooting
15
Attach the display module to the main unit as shown in the right figure (arrow 2).
B 2
2'
Input/Output Powered Extension Units
2 Install/remove the display module.
16 Input/Output Extension Blocks
Remove the display module while pressing and holding the display module fixing hook (B in the figure on the right) as shown in the right figure (arrow 2').
17 Extension Power Supply Unit
18 Other Extension Units and Options
19 Display Module
20 Terminal Block
269
Page 276
FX3G Series Programmable Controllers
19 Display Module(FX3G-5DM)
User's Manual - Hardware Edition
19.2 Installation and Removal
19.2.2 Installation (when the expansion board/connector conversion adapter is used together) The FX3G-40MT/ES is used as the main unit and the expansion board is used together in this example.
1 Attach the expansion board/connector conversion adapter to the main unit.
→ For the attachment method, refer to Chapter 8.
Caution: - Make sure to attach the expansion board/connector conversion adapter before the display module. - The display module cannot be attached to the expansion board/connector conversion adapter attached on the top cover (S) side of the 40/60-point type main unit.
2 Remove the upper connector cover (A in the right figure).
A Top cover (S)
2
3 Remove the part B shown in the right figure using a snipper, etc. Caution: B
Removal of the part B is not necessary when the connector conversion adapter is used together and the main unit is the 14/24point type.
4 Attach the display module to the option connector of the expansion board/connector conversion adapter. Attach the display module to the option connector (D in the figure on the right) of the expansion board/connector conversion adapter while pressing and holding the display module fixing hook (C in the figure on the right) as shown in the right figure (arrow 4).
Remove the display module while pressing and holding the display module fixing hook (C in the figure on the right) as shown in the right figure (arrow 4').
270
C 4 D
4'
Page 277
FX3G Series Programmable Controllers
19 Display Module(FX3G-5DM)
User's Manual - Hardware Edition
11
Summary of Functions
High-Speed Counters
19.3
19.3 Summary of Functions
The display module functions are summarized below. Item
Function
Remarks
Reference
Performs error checks and displays the results.
Button operation
Section 19.7
LANGUAGE (selects the menu display language)
Selects either Japanese or English as the menu display language. Button operation
Section 19.8
Contrast
Adjusts the contrast (-5 to 10); default setting: 0
Button operation
Section 19.9
Displays the current time.
Button operation
Subsection 19.10.1
Sets the current time.
Button operation
Subsection 19.10.2
Keyword
The currently specified keyword can be canceled.
Button operation
Section 19.11
Cassette (Memory cassette transfer)
Allows data transfers between the internal EEPROM and the Button operation memory cassette.
Section 19.12
Specified device monitor function
Displays the monitor/test screen for a specified device at the top.
Section 19.14
Screen saver function
Displays the screen saver if key operation is not given for specified Requires program*3 Section 19.15 period of time.
Display screen protect function
Enables all functions, prohibits change (test) functions, and Requires program protects the top screen (time display).
Operation button ON/OFF information
Allows monitoring of operation button ON/OFF status.
Hexadecimal current value display setting
Changes the display format of the current values and setting values for the timer, counter, data register, extended register, and Requires program*2 Section 19.18 extended file register to a hexadecimal display format.
Display ClockMenu Setting
Non-menu functions Requires program
Section 19.16
Requires program Section 19.17 or monitor
There is no test function for "Input (X)".
*2.
A sequence program is required to enable a hexadecimal display of the timer (T), counter (C), data register (file register) (D) [16-bit/32-bit], extended register (R) [16-bit/32-bit], and extended file register (ER) [16-bit/32-bit] current values. → Refer to Section 19.19 for the setting procedure.
*3.
When no setting is made within a program the screen saver function becomes effective after 10 minutes. → Refer to Section 19.15 for screen saver function.
14
15
16
17 Extension Power Supply Unit
*1.
13
Input/Output Extension Blocks
ErrorCheck
Input/Output Powered Extension Units
Section 19.6
Menu screen functions
12
Test Run, Maintenance, Troubleshooting
Monitor/Test
Input (X)*1, output (Y), auxiliary relay (M), state (S), timer (T), counter (C), data register (D) [16-bit/32-bit], extended register (R) Button operation [16-bit/32-bit], and extended file register (ER) [16-bit/32-bit] monitor/test function.
Top screen (time display)
Wiring for Various Uses
Subsection 19.4.2
Output Wiring
Displays the time indicated by the main unit’s internal real-time Button operation clock.
18 Other Extension Units and Options
19 Display Module
20 Terminal Block
271
Page 278
FX3G Series Programmable Controllers User's Manual - Hardware Edition
19.4
19 Display Module(FX3G-5DM) 19.4 Procedure for Accessing the Menu Screen from the
Procedure for Accessing the Menu Screen from the Title Screen All operation explanations and display screen examples in this manual are in English. When the menu display language is set to Japanese, please convert the screen messages to their Japanese translations. → Refer to Section 19.20 for the Japanese and English display character correspondence table. → Refer to Section 19.8 for menu display language setting.
19.4.1 Title screen The screen shown at right is displayed for 1.5 seconds after the power is turned on. Content
[1]
Model name
[2]
Version
ME L S E C - F FX 3G S e r i e s
[1]
Ve r . 1 . 10
[2]
19.4.2 Top screen (time display) Following the title screen display, the "Current Time screen" is then displayed. 01 . 10 . 08 2 3 : 5 9 : 5 9 ( Wed )
The specified device monitor screen is displayed instead when the specified device monitor function is used. → Refer to Section 19.14 for details of the specified device monitor function. Although the year displays in a 2-digit format (08), this can be changed to a 4-digit format (2008) by revising the program. → Refer to Subsection 19.10.3 for the 2-digit year to 4-digit year change procedure.
19.4.3 Menu screen As shown in the figure at right, the menu screen displays 4 lines of the total menu. Press the [+] button to scroll downward through the menu.
Mo n i t o r / T e s t E r r o r Ch e c k
Button operations at this menu screen are explained below. Button ESC
272
Operation Description
L A NGU A G E Co n t r a s t
Returns to the "top screen" (time display).
C l o c kMe n u
-
Scrolls upward through the menu. Hold for 1 second or longer for high-speed scrolling. This button is disabled when the cursor is located at the beginning of the menu.
Ca s s e t t e
+
Scrolls downward through the menu. Hold for 1 second or longer for high-speed scrolling. This button is disabled when the cursor is located at the end of the menu.
OK
Selects the item where the cursor is blinking.
Ke ywo r d
Page 279
FX3G Series Programmable Controllers
19 Display Module(FX3G-5DM)
User's Manual - Hardware Edition
11
Menu Structure
High-Speed Counters
19.5
19.5 Menu Structure
Title screen
Operation keys
12
OK
Press the [OK] button
FX 3G S e r i e s
ESC
Press the [ESC] button
Ve r . 1 . 10 -
01 . 10 . 08
ESC
+ The [+] / [-] button are used to move the cursor and switch between display screens.
13 OK
D( 16b i t )
ESC
DD ( 3 2 b i t )
Wiring for Various Uses
Approx. 1.5 secs. OK Menu screen Top screen (Time display) or ESC Mo n i t o r / T e s t
Output Wiring
ME L S E C - F
T
2 3 : 5 9 : 5 9 ( W ed )
C
14
R( 16b i t ) DR ( 3 2 b i t )
Specified device monitor screen
DER ( 3 2 b i t )
Test Run, Maintenance, Troubleshooting
Switched by system information setting
ER ( 1 6 b i t ) X
ESC X010
. . . 34567
15
Y
ESC
Input/Output Powered Extension Units
M S
( Spe c i f i ed )
Display example OK ESC
16
E r r o r Ch e c k No
Input/Output Extension Blocks
E r r o r Ch e c k er ror s
17 ESC
Extension Power Supply Unit
L A N GU A G E
OK
L A N GU A G E Japanese Eng l i s h
18 Co n t r a s t
OK
Other Extension Units and Options
Display example Co n t r a s t
ESC
0 ( - 5 ~ 10 )
19 Display Module
C l o c kMe n u
OK ESC
Cu r r e n t Cl ock t i me
20
Se t t i ng
Terminal Block
273
Page 280
FX3G Series Programmable Controllers
19 Display Module(FX3G-5DM)
User's Manual - Hardware Edition
19.5 Menu Structure
Display example Ke ywo r d
OK ESC
The i s
Ke ywo r d no t se t
Display example Ca s s e t t e
OK ESC
274
Memo r y
Ca s s e t t e
Ca s s e t t e
PLC
Ca s s e t t e
PLC
Page 281
FX3G Series Programmable Controllers
19 Display Module(FX3G-5DM)
User's Manual - Hardware Edition
11
Monitor/Test Mode
High-Speed Counters
19.6
19.6 Monitor/Test Mode
19.6.1 Relevant devices
12
Monitored Items Device
Output Wiring
Monitoring and testing can be performed from the "Monitor/Test" menu for the devices listed below. (Monitoring/testing is not possible for the file register (D) and the index register (V/Z)). : Possible : Possible under certain conditions : Not possible -: Item not supported by this device Test Items
Operation Direction
Current Value
Setting Value
Forced ON/OFF
Input [X]
-
-
-
-
-
-
-
Output [Y]
-
-
-
-
*1
-
-
Auxiliary relay [M]
-
-
-
-
*1
-
-
-
*1
-
-
State [S]
-
-
-
Setting Change
-
*2
Counter [C]
*3
*2
-
-
-
-
-
-
File register [D, DD]
-
-
-
-
-
-
Extended register [R, DR]
-
-
-
-
-
-
Extended file register [ER, DER]*4
-
-
-
-
-
-
Index register (V, Z)
-
-
-
-
-
-
A forced ON or OFF is executed for only one operation cycle, and therefore has a considerable effect on the SET/RST and self retaining circuits when the PLC is running. Moreover, a forced ON/OFF result is retained for devices (Y,M,S) which are not being driven by an OUT instruction, etc., in the program.
*2.
Setting values of timer and counter can be changed when the PLC status is as shown below. Program Memory Type Internal EEPROM PROTECT switch ON
Setting Change Enabled/Disabled
RUN
Enabled
STOP
Enabled
RUN
Disabled
STOP
Disabled
RUN
Enabled
STOP
Enabled
17
*3.
The C200 to C255 32-bit up/down counters and the high-speed counters have counting directions.
Extension Power Supply Unit
Memory cassette
RUN/STOP Status
16 Input/Output Extension Blocks
*1.
15 Input/Output Powered Extension Units
Data register [D, DD]
14 Test Run, Maintenance, Troubleshooting
Timer [T]
13 Wiring for Various Uses
Current Value Change
Reset
Contact
*4.
Extended file registers stored in the EEPROM in the main unit, or extended file registers stored in the EEPROM inside the memory cassette when the memory cassette is attached.
18
PROTECT switch OFF
Other Extension Units and Options
19 Display Module
20 Terminal Block
275