Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of FX3G Series Programmable Controllers User's Manual [Hardware Edition]

Manual · Mitsubishi

FX3G Series Programmable Controllers User's Manual [Hardware Edition]

Manual384 pagesPDF 11 MB

Hardware manual for Mitsubishi MELSEC FX3G PLCs and their extension units, including the FX2N-16EYR relay output block.

What this file really is

The old site listed this file as a manual for the Mitsubishi FX-16EYR. This is the FX3G Series hardware manual; it does not name the FX-16EYR itself, only the FX2N-16EYR output extension block and the FX-16EYR-TB terminal block.

Download the PDF11 MB

Filed with · 1 model

Also filed with these models on the old site

Summary

What is in it

The hardware edition user's manual for the Mitsubishi MELSEC FX3G Series programmable controllers. It covers the main units and the equipment that extends them: input/output powered extension units, FX2N input/output extension blocks such as the FX2N-8EYR and FX2N-16EYR relay output blocks, special adapters, expansion boards, the display module, FX Series terminal blocks such as the FX-16EYR-TB, memory cassettes and the battery. Readers find specifications, system configuration rules, I/O numbering, enclosure installation, wiring, high-speed counters, test operation and troubleshooting.

Its parts

  1. Introduction
  2. Features and Part Names
  3. Introduction of Products
  4. Specifications, External Dimensions and Terminal Layout (Main Units)
  5. Version Information and Peripheral Equipment Connectability
  6. Examination of System Configuration
  7. Assignment of Input/Output Numbers and Unit Numbers
  8. Installation In Enclosure
  9. Preparation for Wiring and Power Supply Wiring Procedures
  10. Input Wiring Procedures
  11. Use of High-speed Counters
  12. Output Wiring Procedures
  13. Examples of Wiring for Various Uses
  14. Test Operation, Adjustment, Maintenance and Troubleshooting
  15. Input/Output Powered Extension Units

From the manual

Key facts from this manual

Each line names its page in the PDF.

Mitsubishi user's manual, hardware edition, for the MELSEC FX3G Series programmable controllers (JY997D31301 Version A). It covers the FX3G main units and the FX2N extension units and blocks used with them, including the FX2N-16EYR relay output block, but does not describe the FX-16EYR by that name. It gives specifications, product line-ups and LED troubleshooting.

Read for this summary: pages 1, 29 to 30, 34 to 37, 42 to 47, 181 to 182 and 243 to 245 of 384.

Main units
FX3G-14MT/ES, FX3G-24MT/ES, FX3G-40MT/ES, FX3G-60MT/ES p. 34
Main unit I/O
FX3G-24MT/ES: 14 inputs, 10 outputs; FX3G-40MT/ES: 24 inputs, 16 outputs; FX3G-60MT/ES: 36 inputs, 24 outputs; transistor (sink) outputs p. 35
Power supply
100 to 240V AC (85 to 264V AC allowable), 50/60Hz p. 43
Inputs
24V DC ±10%, sink or source, photocoupler insulated, removable M3 terminal block p. 44
Transistor outputs
Sink type, 5 to 30V DC, 0.5A per point p. 45
Program memory
32000 steps, EEPROM, up to 20,000 writes p. 46
Maximum I/O
256 points: up to 128 on the PLC plus up to 128 remote CC-Link points p. 29
USB port
Built-in USB programming port, 12Mbps p. 29
High-speed counters
1-phase 60kHz x 4 points + 10kHz x 2 points; 2-phase 30kHz x 2 points + 5kHz x 1 point p. 29
Pulse output
Up to 100kHz on 3 axes (Y000 to Y002) on transistor main units; 2 axes on 14- and 24-point units p. 30
Temperature
0 to 55 C operating, -25 to 75 C storage p. 42
FX2N-16EYR
FX2N-16EYR: output extension block with 16 relay outputs on a terminal block p. 36
Relay block ratings
FX2N-8EYR and FX2N-16EYR: 250V AC or 30V DC or less, 2A per point, 80VA inductive, about 10ms response p. 243

What this manual walks you through

  • Choosing FX3G main units, extension units and extension blocks p. 34, 35, 36, 37
  • Checking the environmental and general specifications p. 42
  • Running dielectric withstand and insulation resistance tests p. 43
  • Main unit power, input and output specifications p. 43, 44, 45
  • Device ranges and performance of the main unit p. 46, 47
  • FX2N-8EYR and FX2N-16EYR specifications, terminals and dimensions p. 243, 244, 245
  • Troubleshooting with the POW, ALM and ERR LEDs p. 181, 182

Good to know

  • Dielectric and insulation tests must not be run between an expansion board and the main unit. p. 43
  • Common grounding with heavy electrical equipment is not allowed. p. 42
  • The PLC must not be used above atmospheric pressure. p. 42
  • The clock is backed by a capacitor that needs 30 minutes or more of power to charge fully. p. 47

Questions this manual answers

Which relay output blocks does the FX3G hardware manual list?

It lists the FX2N-8EYR-ES/UL, FX2N-16EYR-ES/UL, FX2N-8EYR and FX2N-16EYR relay output extension blocks. p. 36

How much current can each FX2N-16EYR relay output switch?

2A per point with a resistive load, and 8A or less in total per common. p. 243

What supply voltage does an FX3G main unit need?

100 to 240V AC at 50/60Hz, with an allowable range of 85 to 264V AC. p. 43

What does a flashing ERR LED mean on an FX3G PLC?

A parameter, syntax or ladder error has occurred; run PLC diagnosis and a program check with the programming tool. p. 182

What does the ALM LED mean when it is lit?

The battery voltage is low, and the battery should be replaced at once. p. 181

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Front Cover1
  2. Safety Precautions3
  3. Manual number7
  4. 1. Introduction20
    1. 1.1 Introduction of Manuals20
    2. 1.2 Generic Names and Abbreviations Used in Manuals27
  5. 2. Features and Part Names29
    1. 2.1 Major Features29
    2. 2.2 Names and Functions of Parts31
  6. 3. Introduction of Products34
    1. 3.1 List of Products and Interpretation of Model Names34
    2. 3.2 Connector Types and Cables for Program Communication40
  7. 4. Specifications, External Dimensions and Terminal Layout (Main Units)42
    1. 4.1 Generic Specifications42
    2. 4.2 Power Supply Specifications43
    3. 4.3 Input Specifications44
    4. 4.4 Output Specifications45
    5. 4.5 Performance Specifications46
    6. 4.6 External Dimensions (Weight/Accessories/Installation)48
    7. 4.7 Terminal Layout48
  8. 5. Version Information and Peripheral Equipment Connectability50
    1. 5.1 Version Information50
    2. 5.2 Programming Tool Applicability51
    3. 5.3 Precautions on Use of (Built-in USB) Programming Port55
    4. 5.4 Cautions on using transparent function by way of USB in GOT1000 Series56
    5. 5.5 Cautions on using transparent port (2-port) function of GOT-F900 Series57
    6. 5.6 Other Peripheral Equipment Applicability58
  9. 6. Examination of System Configuration59
    1. 6.1 Configuration of a Whole System59
    2. 6.2 Rules of System Configuration61
    3. 6.3 Number of Input/Output Points and Maximum Number of Input/Output Points63
    4. 6.4 Number of Connected Extension Devices (Including Extension Cable)66
    5. 6.5 Expansion of Main Unit67
    6. 6.6 Expansion of FX2N Series I/O Powered Extension Unit72
    7. 6.7 Expansion of Extension Power Supply Unit (FX3U-1PSU-5V)76
    8. 6.8 Number of Input/Output (Occupied) Points and Current Consumption78
  10. 7. Assignment of Input/Output Numbers and Unit Numbers81
    1. 7.1 Assignment of Input/Output Numbers (X/Y)81
    2. 7.2 Unit Numbers of Special Function Blocks83
140 more lines, from page 85 on
  1. 7.3 Assignment of Communication Channels85
    1. 7.4 "Station No." Label of Expansion Board (FX3G-485-BD)86
    2. 7.5 Trimmer Layout Label of Expansion Board (FX3G-8AV-BD)86
  2. 8. Installation In Enclosure87
    1. 8.1 Installation location90
    2. 8.2 Layout in Enclosure91
    3. 8.3 Examination for Installing Method in Enclosure93
    4. 8.4 Procedures for Installing on and Detaching from DIN Rail95
    5. 8.5 Procedures for Installing Directly (with M4 Screws)99
    6. 8.6 Connecting Methods for Main Unit and Extension Devices102
  3. 9. Preparation for Wiring and Power Supply Wiring Procedures109
    1. 9.1 Preparation for Wiring111
    2. 9.2 Cable Connecting Procedures112
    3. 9.3 Grounding116
    4. 9.4 Examples of External Wiring117
  4. 10. Input Wiring Procedures122
    1. 10.1 Before Starting Input Wiring124
    2. 10.2 24V DC input (Sink and source input type)125
    3. 10.3 100V AC Input131
    4. 10.4 Input Interruption (I00* to I50*)133
    5. 10.5 Pulse Catch (M8170 to M8175)134
    6. 10.6 Pulse width/Pulse period measurement function (Supported in Ver. 1.10 or later)135
  5. 11. Use of High-speed Counters136
    1. 11.1 Outline136
    2. 11.2 Types of Counting and Operations136
    3. 11.3 List of Device Numbers and Functions137
    4. 11.4 Allocation of Device Numbers to Input Numbers138
    5. 11.5 Handling of High-speed Counters139
    6. 11.6 Timing of Updating of Current Value and Comparison of Current Value142
    7. 11.7 Response Frequency and Overall Frequency143
    8. 11.8 Related Devices and Function Switching Procedures144
  6. 12. Output Wiring Procedures146
    1. 12.1 External Wiring for Relay Output Type148
    2. 12.2 External Wiring of Transistor Output (Sink/Source) Type151
    3. 12.3 External Wiring for Triac (SSR) Output Type156
  7. 13. Examples of Wiring for Various Uses159
    1. 13.1 Notes about Examples of Wiring160
    2. 13.2 Digital Switch [DSW Instructions (FNC72)/BIN Instructions (FNC19)]161
    3. 13.3 Input Matrix [MTR Instructions (FNC 52)]164
    4. 13.4 Seven Segment with Latch [SEGL Instructions (FNC74)/BCD Instructions (FNC18)]166
  8. 14. Test Operation, Adjustment, Maintenance and Troubleshooting170
    1. 14.1 Preparation for Test Operation171
    2. 14.2 Running and Stopping Procedures [Power ON]174
    3. 14.3 Operation and Test [Power ON and PLC Running]176
    4. 14.4 Maintenance and Periodic Inspection178
    5. 14.5 Troubleshooting with LEDs181
    6. 14.6 Judgment by Error Codes and Representation of Error Codes183
    7. 14.7 Troubleshooting192
  9. 15. Input/Output Powered Extension Units194
    1. 15.1 Outline196
    2. 15.2 Power supply specifications197
    3. 15.3 FX2N-32ER-ES/UL, FX2N-48ER-ES/UL200
    4. 15.4 FX2N-32ET-ESS/UL, FX2N-48ET-ESS/UL203
    5. 15.5 FX2N-32ER, FX2N-48ER206
    6. 15.6 FX2N-32ET, FX2N-48ET209
    7. 15.7 FX2N-32ES212
    8. 15.8 FX2N-48ER-UA1/UL214
  10. 16. Input/Output Extension Blocks216
    1. 16.1 Outline217
    2. 16.2 FX2N-8ER-ES/UL (24V DC Sink/Source Input, Relay Output)219
    3. 16.3 FX2N-8ER (24V DC Sink Input, Relay Output)222
    4. 16.4 FX2N-8EX-ES/UL, FX2N-16EX-ES/UL (24V DC Sink/Source Input)225
    5. 16.5 FX2N-8EX, FX2N-16EX and FX2N-16EX-C228
    6. 16.6 FX2N-16EXL-C (5V DC Input: 16 Points)232
    7. 16.7 FX2N-8EX-UA1/UL (100V AC Input)235
    8. 16.8 FX2N-8EYR-ES/UL, FX2N-16EYR-ES/UL (Relay Output)237
    9. 16.9 FX2N-8EYT-ESS/UL, FX2N-16EYT-ESS/UL (Transistor Output)240
    10. 16.10 FX2N-8EYR, FX2N-16EYR (Relay Output)243
    11. 16.11 FX2N-8EYT, FX2N-16EYT, FX2N-16EYT-C (Transistor Output)246
    12. 16.12 FX2N-8EYT-H (Transistor Output)250
    13. 16.13 FX2N-16EYS (Triac Output: 16 Points)252
  11. 17. Extension Power Supply Unit254
    1. 17.1 Outline254
    2. 17.2 Specifications255
    3. 17.3 Extension Power Supply Unit Related Precaution256
  12. 18. Other Extension Devices and Optional Units (External Dimensions and Terminal Arrangement)257
    1. 18.1 Special Function Units/Blocks257
    2. 18.2 Special Adapters265
    3. 18.3 Expansion Board268
    4. 18.4 Power Supply271
    5. 18.5 Connector Conversion Adapter271
    6. 18.6 Interface Module272
  13. 19. Display Module(FX3G-5DM)273
    1. 19.1 Specifications273
    2. 19.2 Installation and Removal275
    3. 19.3 Summary of Functions277
    4. 19.4 Procedure for Accessing the Menu Screen from the Title Screen278
    5. 19.5 Menu Structure279
    6. 19.6 Monitor/Test Mode281
    7. 19.7 Error Check288
    8. 19.8 LANGUAGE (Menu Display Language Setting)289
    9. 19.9 Contrast291
    10. 19.10 Clock Menu (Current Time Setting)292
    11. 19.11 Keyword294
    12. 19.12 Memory Cassette Transfers298
    13. 19.13 System Information (Restrictions From PLC)301
    14. 19.14 Specified Device Monitor Function302
    15. 19.15 Screen saver function308
    16. 19.16 Display Screen Protect Function309
    17. 19.17 Operation Button ON/OFF Information313
    18. 19.18 Specifying a Hexadecimal Current Value Display Format314
    19. 19.19 Operation Error Messages and Corrective Actions315
  14. 20. Terminal Block318
    1. 20.1 Outline320
    2. 20.2 External Dimensions and Component Names322
    3. 20.3 Terminal Layout323
    4. 20.4 Installation Work325
    5. 20.5 FX-16E-TB, FX-32E-TB327
    6. 20.6 FX-16EX-A1-TB329
    7. 20.7 FX-16EYR-TB331
    8. 20.8 FX-16EYT-TB, FX-16EYT-H-TB335
    9. 20.9 FX-16EYS-TB338
  15. 21. Memory Cassette341
    1. 21.1 Outline341
    2. 21.2 Specifications341
    3. 21.3 Installation342
    4. 21.4 Removal345
    5. 21.5 Saved Data Content347
    6. 21.6 PROTECT Switch348
    7. 21.7 Memory Cassette <-> PLC (EEPROM Memory) Transfers by Loader Function349
    8. 21.8 Operation Precautions350
  16. 22. Battery351
    1. 22.1 Battery Purpose351
    2. 22.2 Specifications351
    3. 22.3 Setting for Battery352
    4. 22.4 Battery Handling353
    5. 22.5 Battery Replacement354
    6. 22.6 Battery Related Precautions354
  17. Appendix A: Special Device List355
    1. Appendix A-1 Special Auxiliary Relay (M8000 to M8511)355
    2. Appendix A-2 Special Data Register (D8000 to D8511)362
    3. Appendix A-3 Analog expansion boards[M8260 to M8279 and D8260 to D8279]368
    4. Appendix A-4 Analog special adapters[M8280 to M8299 and D8280 to D8299]370
  18. Appendix B: Instruction List374
    1. Appendix B-1 Basic Instructions374
    2. Appendix B-2 Step Ladder Instructions374
    3. Appendix B-3 Applied Instructions ... in Ascending Order of FNC Number375
  19. Warranty379
  20. Revised History380
  21. Back Cover382

From the PDF’s own bookmarks.

The whole text · 49 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 61-6
  2. Pages 7 to 127-12
  3. Pages 13 to 1613-16
  4. Pages 17 to 1917-19
  5. 1. Introduction20-28
  6. 2. Features and Part Names29-33
  7. 3. Introduction of Products34-41
  8. 4. Specifications, External Dimensions and Terminal Layout (Main Units)42-49
  9. 5. Version Information and Peripheral Equipment Connectability50-58
  10. 6. Examination of System Configuration, pages 59 to 6659-66
  11. 6. Examination of System Configuration, pages 67 to 7467-74
  12. 6. Examination of System Configuration, pages 75 to 8075-80
  13. 7. Assignment of Input/Output Numbers and Unit Numbers81-86
  14. 8. Installation In Enclosure, pages 87 to 9487-94
  15. 8. Installation In Enclosure, pages 95 to 10295-102
  16. 8. Installation In Enclosure, pages 103 to 108103-108
  17. 9. Preparation for Wiring and Power Supply Wiring Procedures109-121
  18. 10. Input Wiring Procedures122-135
  19. 11. Use of High-speed Counters136-145
  20. 12. Output Wiring Procedures146-158
  21. 13. Examples of Wiring for Various Uses159-169
  22. 14. Test Operation, Adjustment, Maintenance and Troubleshooting, pages 170 to 177170-177
  23. 14. Test Operation, Adjustment, Maintenance and Troubleshooting, pages 178 to 185178-185
  24. 14. Test Operation, Adjustment, Maintenance and Troubleshooting, pages 186 to 193186-193
  25. 15. Input/Output Powered Extension Units, pages 194 to 201194-201
  26. 15. Input/Output Powered Extension Units, pages 202 to 209202-209
  27. 15. Input/Output Powered Extension Units, pages 210 to 215210-215
  28. 16. Input/Output Extension Blocks, pages 216 to 225216-225
  29. 16. Input/Output Extension Blocks, pages 226 to 235226-235
  30. 16. Input/Output Extension Blocks, pages 236 to 245236-245
  31. 16. Input/Output Extension Blocks, pages 246 to 253246-253
  32. 17. Extension Power Supply Unit254-256
  33. 18. Other Extension Devices and Optional Units (External Dimensions and Terminal Arrangement), pages 257 to 264257-264
  34. 18. Other Extension Devices and Optional Units (External Dimensions and Terminal Arrangement), pages 265 to 272265-272
  35. 19. Display Module(FX3G-5DM), pages 273 to 281273-281
  36. 19. Display Module(FX3G-5DM), pages 282 to 290282-290
  37. 19. Display Module(FX3G-5DM), pages 291 to 299291-299
  38. 19. Display Module(FX3G-5DM), pages 300 to 308300-308
  39. 19. Display Module(FX3G-5DM), pages 309 to 317309-317
  40. 20. Terminal Block, pages 318 to 325318-325
  41. 20. Terminal Block, pages 326 to 333326-333
  42. 20. Terminal Block, pages 334 to 340334-340
  43. 21. Memory Cassette341-350
  44. 22. Battery351-354
  45. Appendix A: Special Device List, pages 355 to 364355-364
  46. Appendix A: Special Device List, pages 365 to 373365-373
  47. Appendix B: Instruction List374-378
  48. Pages 379 to 381379-381
  49. Back Cover382-384

The file

Revision and size

RevisionJY997D31301, Version A, 11/2008
PublisherMitsubishi Electric
Pages384
PDF11 MB
TextText from the PDF itself.

The first pages · 3 of 384

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 384
Page 2
Page 2of 384
Page 3
Page 3of 384