Page 309

FX3G Series Programmable Controllers

19 Display Module(FX3G-5DM)

User's Manual - Hardware Edition

19.16 Display Screen Protect Function

11

19.16.1 System information - display screen protect function

13

Function Restriction Summary

Wiring for Various Uses

1

All functions except the "top screen (time display)" and "top screen (specified device monitor)" functions are disabled.

14

2

The following functions are disabled: "monitor/test’s ’test’ function", "contrast setting", "time change", "menu display language setting",and "memory cassette transfer".

Test Run, Maintenance, Troubleshooting

1. System signal 1 System Information

D

Setting Content (Level)

+3

12 Output Wiring

The display screen protect function prevents accidental operation by restricting the display module functions. The display screen protect function is enabled when no keyword is registered. The display screen protect function's protection level is specified in the system information (system signal 1) "D +3". → Refer to Section 19.3 for display module function. → Refer to Subsection 19.11.5 for the "keyword cancel" procedure. → Refer to Section 19.13 for system information setting.

High-Speed Counters

19.16 Display Screen Protect Function

Other values

All functions are enabled.

2. System signal 2

15

System signal 2 is unrelated to this function.

In this program example, the display screen protect function is set to "level 2". Use this program as a reference when other level settings are specified. In this program example, system information is assigned from D50 to D54 and from M50 to M64. K50

D8300

System information (system No.1) is set at D50 to D54.

MOV

K50

D8301

System information (system No.2) is set at M50 to M64.

MOV

K2

D53

Sets the display screen protect function to "level 2".

16 Input/Output Extension Blocks

M8002 MOV

Input/Output Powered Extension Units

19.16.2 Program example (screen protect function setting)

Initial pulse

17 Extension Power Supply Unit

END

18 Other Extension Units and Options

19 Display Module

20 Terminal Block

303

Page 310

FX3G Series Programmable Controllers

19 Display Module(FX3G-5DM)

User's Manual - Hardware Edition

19.16 Display Screen Protect Function

19.16.3 Keyword and display screen protect function levels and corresponding restrictions If a keyword has been registered, that keyword related restriction takes priority over the "display screen protect function" : Usable : Timer and counter settings cannot be changed : Only monitor function is usable (test function is not available) : Unusable Function Name

Display Screen Protect

Keyword

16-digit keyword*1 setting--> None 8-digit keyword setting (level) -->

All online operations prohibited

Writing prohibited

Reading/writing prohibited

A (All operations prohibited)

B (Read/ Incorrect write protection)

C (Erroneous write prohibited)

None

1

2

Top screen (time display) Top screen(specified device monitor)

*2

Monitor/Test ErrorCheck Display screen protect function Menu display language setting Contrast adjustment Display

Time

Setting

Keyword (cancel)

-

Memory cassette transfer

*1.

Customer keyword/Permanent PLC lock included

*2.

The test function can be enabled or disabled by setting the specified device monitor.

19.16.4 Relationship between keyword and display screen protect function If the PLC's keyword registration function is used, that keyword related restriction takes priority over the display module's "display screen protect function". The relationship between keywords and the display screen protect function is shown below. Keyword registration

Keyword Status Keyword is not canceled

Keyword is registered Keyworde is canceled

Keyword is not registered

304

Display Screen Protect Status Keyworde is being used Keyword is not being used Keyword is being used Keyworde is not being used

Function Restrictions Restriction of functions is according to the keyword level. All functions are enabled (no restrictions).

Keyword is being used

Restriction of functions is according to the display screen protect function.

Keyword is not being used

All functions are enabled (no restrictions).

Page 311

FX3G Series Programmable Controllers

19 Display Module(FX3G-5DM)

User's Manual - Hardware Edition

19.16 Display Screen Protect Function

11 High-Speed Counters

19.16.5 Keyword levels 1. For 8-Digit Keyword 8-Digit Keyword Level

Keyword Content

Keyword Input Example

B (Read/Incorrect write protection)

8-digit hexadecimal value beginning with "B".

B1234567 BABCDEF7

C (Erroneous write prohibited)

8-digit hexadecimal value beginning with "C".

C8904567 CDEF567F

12 Output Wiring

A (All operations prohibited)

8-digit hexadecimal value beginning with "A" 0ABCDEF2 or "0 to 9" numeral. AABCD345

13

2. For 16-Digit Keyword (Customer keyword/Permanent PLC lock included) Keyword Content

Keyword Input Example

All online operations prohibited

"A to F", "0 to 9" 16-digit value.

0ABCDEF262297529 AABCDEBF34523724

Writing prohibited

"A to F", "0 to 9" 16-digit value.

B123456789012345 7ABCDEF73DAEB93A

Reading/writing prohibited

"A to F", "0 to 9" 16-digit value.

2890445234817567 CDEF567FABDFEA46

Wiring for Various Uses

16-Digit Keyworde Level

14

Display screen protect function status

Specified device monitor function

None

2 (Test function prohibition setting)

1 (Initial screen fixing function) •

Invalid

•

• • •

Initial screen: Specified device monitor Transition to another screen: Enabled Both monitoring and testing of specified device are enabled.

•

Initial screen: Fixed to clock display Transition to another screen: Disabled

• • •

• •

• • •

Initial screen: Specified device monitor Transition to another screen: Disabled Initial screen: Specified device monitor Transition to another screen: Disabled Both monitoring and testing of specified device are enabled.

• • • • •

Initial screen: Clock display Transition to another screen: Enabled Only monitoring of specified device is enabled. Initial screen: Specified device monitor Transition to another screen: Enabled Only monitoring of specified device is enabled. Initial screen: Specified device monitor Transition to another screen: Enabled Only monitoring of specified device is enabled.

16

17

18 Other Extension Units and Options

• Valid Both monitoring and • testing are enabled. • (M = ON)

Initial screen: Specified device monitor Transition to another screen: Enabled Testing of specified device is disabled.

•

Extension Power Supply Unit

Valid Only monitoring is enabled. (M = OFF)

Initial screen: Clock display Transition to another screen: Enabled

Input/Output Extension Blocks

•

15 Input/Output Powered Extension Units

When the display screen protect function is used, the generated function restriction has higher priority than the specified device monitor function. The table below shows the relationship between the specified device monitor function and the display screen protect function.

Test Run, Maintenance, Troubleshooting

19.16.6 Relationship between specified device monitor function and display screen protect function

19 Display Module

20 Terminal Block

305

Page 312

FX3G Series Programmable Controllers User's Manual - Hardware Edition

19 Display Module(FX3G-5DM) 19.16 Display Screen Protect Function

19.16.7 Pointers for using the display screen protect function The display screen protect function settings should be specified in a sequence program. • The protect function is enabled by using the display module's "monitor/test function" to change the system information's (system signal 1) "D +3" current value to "1" or "2". • Once the setting is made, it cannot be canceled from the display module. • To cancel the setting, use the programming tool to change the system information's (system signal 1) "D +3" current value to a value other than "1" and "2". If the system information's (system signal 1) "D +3" is set in a general purpose data register, however, the display screen protect function can be canceled by turning the power off, then on again.

306

Page 313

FX3G Series Programmable Controllers

19 Display Module(FX3G-5DM)

User's Manual - Hardware Edition

19.17 Operation Button ON/OFF Information

11

Operation button ON/OFF information can be monitored at the system information (system signal 2) "M +4 to M +7" while the PLC is running. Various applications of this function are described below. → Refer to Section 19.13 for system information setting.

1. Operation button function checks The programming tool can be used to monitor the system information's (system signal 2) "operation button ON/OFF information", to verify that operation buttons are functioning properly. Devices handled in the specified device monitor function can be changed over by using both the "specified device monitor display status" and "operation button ON/OFF information" in the system information (system signal 2). → Refer to Section 19.14 for the specified device monitor function setting procedure.

1. System signal 1 System signal 1 has no system information related to this function.

15

2. System signal 2 +4 +5

M

+6

M

+7

ON

Description [ESC] button is pressed.

OFF

[ESC] button is not pressed.

ON

[-] button is pressed.

OFF

[-] button is not pressed.

ON

[+] button is pressed.

OFF

[+] button is not pressed.

ON

[OK] button is pressed.

OFF

[OK] button is not pressed.

16 Input/Output Extension Blocks

M

Status

Input/Output Powered Extension Units

M

14 Test Run, Maintenance, Troubleshooting

19.17.2 System information - operation button ON/OFF information

13 Wiring for Various Uses

2. Specified device monitor function device changes

System Information

12 Output Wiring

19.17.1 Various applications

High-Speed Counters

19.17 Operation Button ON/OFF Information

17 Extension Power Supply Unit

18 Other Extension Units and Options

19 Display Module

20 Terminal Block

307

Page 314

FX3G Series Programmable Controllers

19 Display Module(FX3G-5DM)

User's Manual - Hardware Edition

19.18 Specifying a Hexadecimal Current Value Display

19.18 Specifying a Hexadecimal Current Value Display Format The procedure for specifying a hexadecimal display format for current values which display at the "Monitor/ Test" menu explained below. The display format is specified by the system information's (system signal 2) "M +8" ON/OFF status. The display formats which correspond to the ON and OFF statuses are shown in Section 19.13 below. The display format should either be fixed as decimal or hexadecimal. Switching between the two should be possible by an external operation. → Refer to Section 19.13 for system information setting.

19.18.1 System information - specifying a hexadecimal current value display format 1. System signal 1 System signal 1 is unrelated to this function.

2. System signal 2 System Information

Setting Content ON

M

+8

OFF

Display Format

Display Subjects

Hexadecimal Timer (T) [current value/setting value], counter (C) [current value/setting value], data register (D) [16-bit/32-bit], extended register (R) [16-bit/32-bit], and extended file register Decimal (ER) [16-bit/32-bit]

19.18.2 Program example 1 (specifying a hexadecimal data display format) The following program example specifies a hexadecimal display format for current values and setting values which display at the "Monitor/Test" screen. In this program example, system information is assigned from D50 to D54 and from M50 to M64. M8002 MOV

K50

D8300

System information (system No.1) is set at D50 to D54.

MOV

K50

D8301

System information (system No.2) is set at M50 to M64.

M58

Specifies a hexadecimal display format for current values which appear at the Monitor/Test screen.

Initial pulse M8000 RUN monitor END

19.18.3 Program example 2 (specifying a decadal data display format) The following program example specifies a decimal display format for current values and setting values which appear at the "Monitor/Test" screen. In this program example, system information is assigned from D50 to D54 and from M50 to M64. M8002 MOV

K50

D8300

System information (system No.1) is set at D50 to D54.

MOV

K50

D8301

System information (system No.2) is set at M50 to M64.

M58

Specifies a decimal display format for current values which appear at the Monitor/Test screen.

Initial pulse M8000 RUN monitor

308

Page 315

FX3G Series Programmable Controllers

19 Display Module(FX3G-5DM)

User's Manual - Hardware Edition

19.19 Operation Error Messages and Corrective Actions

11 High-Speed Counters

19.19 Operation Error Messages and Corrective Actions The following is a list of error messages which the system displays after an operation is performed. Relevant Menu Screen •

Japanese

Corrective Action Cancel the keyword, then attempt the operation again.

The keyword is not set

No keyword has been registered. Keyword cannot be registered from the display module. A programming tool such as GX Developer, etc., is required to register keyword.

Incorrect Keyword!

The entered keyword does not match the registered keyword. Verify the registered keyword, then enter the correct keyword.

PLC is running

Stop the PLC, then attempt the operation again.

Keyword

•

(setting change*1) Memory cassette transfer

Memory Cassette is write-protected

Turn the memory cassette’s write-protected status to OFF, then attempt the operation again.

Keyword (setting change) Memory cassette transfer

Fatal error occurred

For details, refer to Subsection 19.19.1.

Memory Cassette is not connected

Turn the PLC power OFF, install the memory cassette, then attempt the operation again.

The Keyword is set in the Internal Memory

Remove the memory cassette, restart the unit (power OFF ON), then use the programming tool to cancel the keyword in the internal EEPROM.

Transfer completed

Transfer successful.

Transfer failed

Check if the memory cassette is properly installed.

• •

•

Memory cassette transfer

•

Memory cassette transfer (reading/writing)

15

16

The setting value can also be changed when the PLC is in RUN mode.

Input/Output Extension Blocks

*1.

14

Input/Output Powered Extension Units

Monitor/test

13

Test Run, Maintenance, Troubleshooting

•

12

Wiring for Various Uses

This operation is protected by the keyword

Output Wiring

•

All menus

English

17 Extension Power Supply Unit

18 Other Extension Units and Options

19 Display Module

20 Terminal Block

309

Page 316

FX3G Series Programmable Controllers User's Manual - Hardware Edition

19 Display Module(FX3G-5DM) 19.19 Operation Error Messages and Corrective Actions

19.19.1 When a "Fatal error occurred" message appears Operation is possible with the "Level C" or "Level B" keyword function restrictions. However, the system is probably in one of the statuses described below. Check these statuses in the order shown below, and take the appropriate corrective action.

1. Perform an error check at the display module, and if an error is active, take the appropriate corrective action. → Refer to Section 19.7 for the error check procedure. If a program error is active: The fatal error was probably activated due to a program error. Use the programming tool to correct the program. → Refer to Section 14.6 for error codes and corrective actions. → Refer to Subsection 14.5.3 for watchdog timer error corrective actions. If no program error is active: There may be a problem with the PLC's memory content. Perform the following procedure. 1) Use the programming tool to perform a program memory all-clear. 2) Rewrite the program. 3) Stop the PLC, turn the power ON, display the "Error Check" screen and check to refer to if the "Fatal error occurred" message appears. - If the "Fatal error occurred" message appears, perform the corrective action described at item "2" below. - If the "Fatal error occurred" message does not appear, set the PLC to a RUN state, then check again if the message appears. If the message appears, a watchdog timer error has probably occurred. In this case, the program should be re-examined. → Refer to Subsection 14.5.3 for watchdog timer error corrective actions.

2. If the "Fatal error occurred" message still appears after performing the corrective actions described in item 1 above, perform the following procedure to check for symptom changes. Turn the power OFF and disconnect all extension devices. (extension connectors, extension cables, and expansion board connectors) Turn the power ON again at the main unit, display the "Error Check" screen again, and check if the "Fatal error occurred" message appears. 1) If the "Fatal error occurred" message appears: The main unit hardware may have failed. Contact your local Mitsubishi Electric distributor. 2) If the "Fatal error occurred" message does not appear: Turn the power OFF, connect the extension devices, then operate the system again to check for errors. If the problem persists, there may be main unit or extension device hardware failure. Contact your local Mitsubishi Electric distributor.

310

Page 317

FX3G Series Programmable Controllers User's Manual - Hardware Edition

19 Display Module(FX3G-5DM) 19.20 Menu Display Characters - Japanese and English

Menu Screen

Japanese

English

12 Output Wiring

Monitor/Test ErrorCheck LANGUAGE Contrast ClockMenu Keyword Cassette

Menu

13 Wiring for Various Uses

ErrorCheck No errors ErrorCheck ErrorCheck Error code LANGUAGE Japanese English

Contrast

Contrast

14 Test Run, Maintenance, Troubleshooting

LANGUAGE

Current time Clock setting Clock setting

15

Current time is set

Input/Output Powered Extension Units

ClockMenu

Please input Keyword ******** ********

All operation is possible

17

Incorrect Keyword!

Extension Power Supply Unit

Memory cassette transfer

Memory Cassette Cassette PC Cassette PC Cassette PC Please wait...

Cassette PC

Cassette PC Please wait...

18 Other Extension Units and Options

Cassette PC

Cassette PC Cassette PC

16

Make Keyword valid? OK Execute ESC Cancel

Input/Output Extension Blocks

Keyword

High-Speed Counters

19.20 Menu Display Characters - Japanese and English Display Character Correspondence Table.

11

Transfer completed

19 Display Module

Transfer failed

20 Terminal Block

311