The text of a manual · part 37 of 49
FX3G Series Programmable Controllers User's Manual [Hardware Edition]: 19. Display Module(FX3G-5DM), pages 291 to 299
Pages 291 to 299 of 384, from FX3G Series Programmable Controllers User's Manual [Hardware Edition]
The original document is the PDF (11 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Mitsubishi FX-16EYR
Page 291
FX3G Series Programmable Controllers
19 Display Module(FX3G-5DM)
User's Manual - Hardware Edition
11
Contrast The liquid crystal display contrast setting is specified at the "Contrast" menu. Selections made at this menu are saved at D8302. A contrast setting of "0" is specified at factory default.
0 ( - 5 ~ 10 )
13
Co n t r a s t 3 ( - 5 ~ 10 )
Button
14
Operation Description
Test Run, Maintenance, Troubleshooting
ESC
Cancels the operation and returns to the "menu screen".
-
Lowers the contrast (decreases the numeric value. The value can be decreased to -5.)
+
Increases the contrast (increases the numeric value. The value can be increased to +10.)
OK
Registers the selected setting and returns to the "menu screen".
Wiring for Various Uses
2) Use the [+] / [-] buttons to adjust the contrast. To cancel the operation and return to the "menu screen", press [ESC].
12
Co n t r a s t
Output Wiring
1) At the menu screen, use the [+] / [-] buttons to move the cursor to the "Contrast" item, then press [OK] to display the "contrast adjustment screen". To cancel the operation and return to the "top screen (time display)", press [ESC].
High-Speed Counters
19.9
19.9 Contrast
15 Input/Output Powered Extension Units
3) Press the [OK] button to register the selected setting and return to the "menu screen".
16 Input/Output Extension Blocks
17 Extension Power Supply Unit
18 Other Extension Units and Options
19 Display Module
20 Terminal Block
285
Page 292
FX3G Series Programmable Controllers User's Manual - Hardware Edition
19 Display Module(FX3G-5DM) 19.10 Clock Menu (Current Time Setting)
19.10 Clock Menu (Current Time Setting) The "ClockMenu" menu consists of "current time" and the "clock setting" items. The current time should be set before operating the system.
19.10.1 Clock setting procedure 1) At the menu screen, use the [+] / [-] buttons to move the cursor to the "ClockMenu" item, then press [OK] to display the selection screen shown at right. To cancel the operation and return to the "top screen (time display)", press [ESC]. 2) Use the [+] / [-] buttons to move the cursor to the "Clock setting" item. To cancel the operation and return to the "menu screen", press [ESC].
3) Press the [OK] button to display the "Clock setting screen". To cancel the operation and return to the "selection screen", press [ESC].
Cu r r e n t Cl ock
Cu r r e n t Cl ock t i me se t t i ng t i me se t t i ng
01 . 10 . 2008 * 2 3 : 5 9 : 5 9 ( Wed )
4) Use the [+] / [-] buttons to change the blinking data as desired, then press [OK] to register the change. Settings are performed in the following sequence: Year Month Day Hours Minutes Seconds. After pressing [OK] to register the final "seconds" setting, a "Current time is set" message is displayed, completing the current time setting procedure. Button
Operation Description
ESC
Returns to the previous setting item. Returns to the "selection screen", when at the "Year" item ("Year" is blinking) position.
-
Reduces the value. Hold for 1 second or longer for high-speed reduction.
+
Increases the value. Hold for 1 second or longer for high-speed increase.
OK
Proceeds to the next setting item. "Current time is set" message displays if pressed at the "Seconds" item ("Seconds" is blinking).
10 .
1 . 2008 *
2 3 : 5 9 : 5 9 ( Wed )
The default "Year" display is a 2-digit value indicating the Western calendar year.
5) Press [OK] or [ESC] to return to the "selection screen". 6) Press [ESC] to return to the "menu screen". Cu r r e n t Cl ock
286 t i me se t t i ng
Page 293
FX3G Series Programmable Controllers User's Manual - Hardware Edition
19 Display Module(FX3G-5DM) 19.10 Clock Menu (Current Time Setting)
11
Cu r r e n t Cl ock
12 t i me se t t i ng
Output Wiring
1) At the menu screen, use the [+] / [-] buttons to move the cursor to the "ClockMenu" item, then press [OK] to display the selection screen shown to the right. To cancel the operation and return to the "top screen (time display)", press [ESC].
High-Speed Counters
19.10.2 Displaying the current time
2) Use the [+] / [-] buttons to move the cursor to the "Current time" item. To cancel the operation and return to the "menu screen", press [ESC].
Button ESC
Operation Description Returns to the "selection screen".
-
Disabled
+
Disabled
OK
Returns to the "selection screen".
13
2-digit display
Wiring for Various Uses
3) Press the [OK] button to display the current time. To cancel the operation and return to the "selection screen", press [ESC].
01 . 10 . 08 2 3 : 5 9 : 5 9 ( Wed )
14 Test Run, Maintenance, Troubleshooting
4-digit display
4) Press [OK] or [ESC] to return to the "selection screen". 5) Press [ESC] to return to the "menu screen".
01 . 10 . 2008 2 3 : 5 9 : 5 9 ( Wed )
15 The "Year" data displays as 2-digit value with a default. This can be changed to a 4-digit display by the following programming.
Input/Output Powered Extension Units
19.10.3 Changing the current time's "Year" from 2-digit format to 4-digit format
16
M8002
It is also possible to set the current time with a sequence program. → Refer to the "time setting" (special devices D8013 to D8019) section of the Programming Manual.
Input/Output Extension Blocks
MOV K2000 D8018
17 Extension Power Supply Unit
18 Other Extension Units and Options
19 Display Module
20 Terminal Block
287
Page 294
FX3G Series Programmable Controllers
19 Display Module(FX3G-5DM)
User's Manual - Hardware Edition
19.11 Keyword
19.11 Keyword Keywords registered at the PLC can be canceled from the "Keyword" menu. When canceled, all operations are enabled. Registering or changing keywords is not possible at the display module. The programming tool must be used in advance to register new keywords.
19.11.1 Keyword types and levels Keywords can be entered in 2 ways (8-digit or 16-digit*1), depending on the peripheral device in question. • For a [keyword (8-digit)] + [2nd keyword (8-digit)] = 16-digit input: Processing is possible only with a peripheral device version compatible with the FX3G PLC. • For an keyword (8-digit) input only: Processing is possible even with a peripheral device version that is not compatible with the FX3G PLC. Peripheral Device
Number Of Digits
16-digit *1
8-digit
*1.
Registration Method
FX3G Compatible
Not FX3G Compatible
Keyword Registration Level
Keyword Description
Reading/writing prohibited
By selecting the keyword registration level at the GX Developer’s setting screen.
16-digit hexadecimal value (A to F, 0 to 9) Writing prohibited [Ex] All online operations FAB05C25DAECF293 AABCDEFF34509345 prohibited
-
A (A, 0 to 9 first char.)
8-digit hexadecimal value beginning with "A" or "0 to 9". [Ex]0ABCDEF2, AABCD345
B
8-digit hexadecimal value beginning with "B". [Ex]B1234567,BABCDEF7
C
8-digit hexadecimal value beginning with "C". [Ex]C8904567,CDEF567F
By entering the level at the first character when entering the keyword
Customer keyword/Permanent PLC lock included
19.11.2 Level-specific restrictions screen list : Function enabled : Timer and counter setting values cannot be changed. : Only monitor function is usable (test function is not available) -: Function disabled
Function name
None
Keyword: 8 digits Label entered as the first character at Keyword input A
B
C
Keyword: 16 digits Selected at GX Developer setting screen*1 All online operations prohibited
Reading/ writing prohibited
Writing prohibited
Top screen (time display) Top screen (Specified device monitor) Monitor/Test
-
ErrorCheck
-
-
Menu display language setting
-
-
Contrast adjustment
-
-
-
-
Display
Time
Setting
Keyword (cancel)
-
Memory cassette transfer
-
-
-
-
Display screen protect function
-
-
-
-
*1.
288
-
Customer keyword/Permanent PLC lock included
Page 295
FX3G Series Programmable Controllers
19 Display Module(FX3G-5DM)
User's Manual - Hardware Edition
19.11 Keyword
11 High-Speed Counters
19.11.3 Keyword storage The system has no process for recovering registered keyword which are forgotten. Therefore, be sure to store the keywords in a secure location.
12
19.11.4 Screens requiring keyword for access
13 Wiring for Various Uses
Not registered
Menu screen Co n t r a s t C l o c kMe n u
The
Ke ywo r d i s
Ke ywo r d no t se t
14
Ca s s t t e
Test Run, Maintenance, Troubleshooting
Registered When switching to menu prohibited by keyword occurs
If keyword is correct
Keyword P l ease i npu t
Ke ywo r d
Al l i s
Registered ope r a t i on
15 poss i b l e
0* * * * * * * ope ra t i on i s p r o t ec t ed by t he
Ke ywo r d
Input/Output Powered Extension Units
Th i s
Output Wiring
At the menu screen, use the [+] / [-] buttons to move the cursor to the "Keyword" item, then press [OK] to display one of the 4 screens shown below (the screen that displays depends on the keyword status). If no keywords are registered, press [ESC] to return to the "menu screen". To cancel the operation and return to the "top screen (time display)", press [ESC].
Registered Keyword + 2nd keyword P l ease
If keyword is incorrect i npu t
Ke ywo r d
Input/Output Extension Blocks
0* * * * * * *
16
I ncor r ec t Ke ywo r d !
* * * * * * * *
Canceled
17
Ke ywo r d
Extension Power Supply Unit
Ma k e va l i d? OK
Execu t e
ESC
Ca n c e l
18 Other Extension Units and Options
19 Display Module
20 Terminal Block
289
Page 296
FX3G Series Programmable Controllers
19 Display Module(FX3G-5DM)
User's Manual - Hardware Edition
19.11 Keyword
19.11.5 Canceling a keyword 1) At the menu screen, use the [+] / [-] buttons to move the cursor to the "Keyword" item, then press [OK] to display the "keyword input screen". If a keyword has been registered, one of the following screens is displayed. - If a 16-digit keyword is registered, an 8-digit 2-line screen (shown at left below) is displayed. - If an 8-digit keyword is registered, an 8-digit 1-line screen (shown at right below) is displayed. 16-digit keyword P l ease
8-digit keyword i npu t
Keyword
Ke ywo r d
P l ease i npu t
Ke ywo r d
0* * * * * * *
2nd keyword
* * * * * * * *
0* * * * * * *
2) Use the [+] / [-] buttons to specify the first digit of the keyword, then press [OK] to proceed to the next digit. To cancel the operation and return to the "menu screen", press [ESC]. 8-digit keyword
16-digit keyword P l ease i npu t
P l ease
Ke ywo r d i npu t
Ke ywo r d
6723B967 AF 2C4 5B0
01234567
Lowest order digit (final digit)
Lowest order digit (final digit)
Button
Operation Description
ESC
Cancels the operation and returns to the "menu screen" if pressed when the keyword’s left-most digit (highest order digit) is blinking. Cancels the input and moves leftward to the next digit (higher order digit) if pressed when a digit other than the left-most digit is blinking.
-
Reduces the value (F E...2 1 0). Hold for 1 second or longer for high-speed reduction.
+
Increases the value (0 1 2...E F). Hold for 1 second or longer for high-speed increase.
Highest order Registers the specified value and moves to the next digit input position. digit to 2nd digit If [OK] is pressed at the lowest order digit, and if the entered keyword is correct, the Keyword is canceled. OK
Lowest order Correct Keyword digit (final digit) Incorrect Keyword
An "All operation is possible" message appears, and the Keyword is canceled. A "Incorrect Keyword!" message appears.
3) If the [OK] button is pressed at the lowest order position, the entered Keyword is registered and the message shown to the right appears. If the "Incorrect Keyword" message appears, press [ESC] and return to step 1). 4) Press [OK] or [ESC] to return to the "menu screen".
If keyword is correct Al l i s ope r a t i on poss i b l e
If keyword is incorrect I ncor r ec t Ke ywo r d !
290
Page 297
FX3G Series Programmable Controllers
19 Display Module(FX3G-5DM)
User's Manual - Hardware Edition
19.11 Keyword
11
1) At the menu screen, use the [+] / [-] buttons to move the cursor to the "keyword" item, then press [OK] to display the "enable keyword" screen.
Button ESC -
Operation Description
Ma k e
Ke ywo r d
12 va l i d? OK
Execu t e
ESC
Ca n c e l
Output Wiring
2) Press the [OK] button to enable the keyword. Or, to retain the keyword's canceled status, press [ESC].
High-Speed Counters
19.11.6 Enabling a keyword
Cancels the operation and returns to the "menu screen". Disabled
+
Disabled
OK
Enables the Keyword and returns to the "menu screen".
13 Wiring for Various Uses
14 Test Run, Maintenance, Troubleshooting
15 Input/Output Powered Extension Units
16 Input/Output Extension Blocks
17 Extension Power Supply Unit
18 Other Extension Units and Options
19 Display Module
20 Terminal Block
291
Page 298
FX3G Series Programmable Controllers
19 Display Module(FX3G-5DM)
User's Manual - Hardware Edition
19.12 Memory Cassette Transfers
19.12 Memory Cassette Transfers Data transfers between the internal EEPROM memory and a connected memory cassette can be performed from the "Cassette" menu when the PLC is in a STOP state. This menu is disabled, however, if a keyword is registered in the internal EEPROM. In this case, remove the memory cassette and use the programming tool to cancel the internal EEPROM's keyword. Item
Operation Description
Cassette PLC
Copies internal program memory (EEPROM) data to a connected memory cassette.
Cassette PLC
Copies data from a connected memory cassette to the internal program memory (EEPROM).
Caution When a memory cassette is connected with a display module, perform the data transfer procedure in the display module. The memory cassette cannot be used for the data transfer procedure.
19.12.1 Transfer from internal EEPROM to memory cassette (Cassette <- PLC) 1) At the menu screen, use the [+] / [-] buttons to move the cursor to the "Cassette" item, then press [OK] to display the "memory cassette transfer screen". To cancel the operation and return to the "top screen (time display)", press [ESC].
Memo r y
2) Use the [+] / [-] buttons to move the cursor to the "Cassette PLC" item, then press [OK] to display the screen shown to the right. To cancel the operation and return to the "memory cassette transfer screen", press [ESC].
Ca s s e t t e
Ca s s e t t e
PLC
Ca s s e t t e
PLC
OK ESC
3) Press [OK] to begin the transfer. Or, press [ESC] to cancel the operation. Button
Operation Description
ESC
Cancels the operation and returns to the "memory cassette transfer screen".
-
Ca s s e t t e
PLC
Ex cu t e Ca n s e l
Ca s s e t t e
PLC
P l ease wa i t . . .
Disabled
+
Disabled
OK
Executes the transfer.
Caution Do not turn the PLC power off or perform writing from the programming tool while a program is being transferred by a "memory cassette transfer" menu operation, as these actions could destroy the program, causing incorrect operation of the PLC. 4) Press [OK] or [ESC] to return to the "memory cassette transfer screen".
292
Page 299
FX3G Series Programmable Controllers User's Manual - Hardware Edition
19 Display Module(FX3G-5DM) 19.12 Memory Cassette Transfers
PLC i s r unn i ng
12 Ca s s e t t e
Output Wiring
- The transfer is not executed if a "Transfer failed" message appears. In this case, turn the power off, check the memory cassette connection, then attempt the operation again from the first step.
11 High-Speed Counters
• Result and measures to take - The transfer is not executed if a "PLC is running" message appears. In this case, set the PLC to the STOP state, then perform step 3) described above.
PLC
13
Tr ans f e r
- The transfer is not executed if a "Memory Cassette is writeprotected" message displays. In this case, turn the power OFF, set the memory cassette PROTECT switch to OFF, then attempt the operation again from the first step.
Wiring for Various Uses f a i l ed
Memo r y
Ca s s e t t e i s
- A "Transfer completed" message appears when the transfer is completed. When this message appears, press [OK] or [ESC] to display the "Cassette screen".
Ca s s e t t e
PLC
15
Tr ans f e r
Input/Output Powered Extension Units c omp l e t e d
5) Press [ESC] to display the "menu screen".
19.12.2 Transfer from memory cassette to internal EEPROM (Cassette -> PLC)
Ca s s e t t e
PLC
Ca s s e t t e
PLC
17 Ca s s e t t e OK ESC
Button
Operation Description
ESC
Cancels the operation and returns to the "memory cassette transfer screen".
-
PLC
Ex cu t e Ca n s e l
18 Ca s s e t t e
PLC
P l ease wa i t . . .
Other Extension Units and Options
3) Press [OK] to begin the transfer. Or, press [ESC] to cancel the operation.
Ca s s e t t e
Extension Power Supply Unit
2) Use the [+] / [-] buttons to move the cursor to the "Cassette PLC" item, then press [OK] to display the screen shown to the right. To cancel the operation and return to the "memory cassette transfer screen", press [ESC].
16 Memo r y
Input/Output Extension Blocks
1) At the menu screen, use the [+] / [-] buttons to move the cursor to the "Cassette" item, then press [OK] to display the "memory cassette transfer screen". To cancel the operation and return to the "top screen (time display)", press [ESC].
Disabled Disabled
OK
Executes the transfer.
19
Caution Do not turn the PLC power off or perform writing from the programming tool while a program is being transferred by a "memory cassette transfer" menu operation, doing so may destroy the program and disorder the PLC.
Display Module
+
14 Test Run, Maintenance, Troubleshooting wr i t e - p r o t ec t ed
20 Terminal Block
4) Press [OK] or [ESC] to return to the "memory cassette transfer screen".
293