Page 210
FX3G Series Programmable Controllers
15 Input/Output Powered Extension Units
User's Manual - Hardware Edition
15.6 FX2N-32ET, FX2N-48ET
3. Output specifications (transistor output type) Item Output Points
FX2N-32ET
FX2N-48ET
16 points
24 points
Connection type
Removable terminal block (M3 screw)
Output unit/type
Transistor/sink output
External power supply
5 to 30V DC
Output circuit insulation
Photo-coupler insulation
Indication of output operation
Max. load
Resistance load
Activation of the photo-coupler will light the LED indicator lamp on panel. 0.5A/point 0.5A/point The total load current per common terminal The total load current per common terminal should be the following value. should be the following value. • 4 output points/common terminal: 0.8A or • 8 output points/common terminal: 1.6A or less less • 8 output points/common terminal: 1.6A or less
Inductive load
12W/24V DC
Open circuit leakage current
0.1mA/30V DC
Min. load Response time
OFF ON
0.2ms or less/200mA (at 24V DC)
ON OFF
0.2ms or less/200mA (at 24V DC)
Load Output circuit configuration
DC power supply Fuse
Y COM
A common number applies to the
204 of [COM
].
Page 211
FX3G Series Programmable Controllers
15 Input/Output Powered Extension Units
User's Manual - Hardware Edition
15.6 FX2N-32ET, FX2N-48ET
11 High-Speed Counters
15.6.2 External dimensions FX2N-32ET 2- 4.5 mounting holes
12
90 (3.55")
Output Wiring
13 Wiring for Various Uses
80 (3.15") (mounting hole pitch)
Unit : mm (inches)
9 (0.36")
140 (5.52") (mounting hole pitch) 150 (5.91")
87 (3.43")
FX2N-48ET
14
2- 4.5 mounting holes
90 (3.55")
172 (6.78") (mounting hole pitch) 182 (7.17")
15 Input/Output Powered Extension Units
80 (3.15") (mounting hole pitch)
Test Run, Maintenance, Troubleshooting
Unit : mm (inches)
9 (0.36") 87 (3.43")
16 Input/Output Extension Blocks
15.6.3 Terminal layout FX2N-32ET L
N
COM X0 X2 X4 X6 X0 X2 X4 X6 24+ X1 X3 X5 X7 X1 X3 X5 X7
17 Extension Power Supply Unit
FX 2N-32ET Y0 Y2
Y4 Y6
Y0 Y2
Y4 Y6
COM1 Y1 Y3 COM2 Y5 Y7 COM3 Y1 Y3 COM4 Y5 Y7
18
L
N
Other Extension Units and Options
FX2N-48ET COM X0 X2 X4 X6 X0 X2 X4 X6 X0 X2 X4 X6 24+ X1 X3 X5 X7 X1 X3 X5 X7 X1 X3 X5 X7
FX2N-48ET
19 Display Module
Y0 Y2 Y4 Y6 Y0 Y2 Y4 Y6 Y0 Y2 Y4 Y6 COM5 COM1 Y1 Y3 COM2 Y5 Y7 COM3 Y1 Y3 COM4 Y5 Y7 Y1 Y3 Y5 Y7
20 Terminal Block
205
Page 212
FX3G Series Programmable Controllers
15 Input/Output Powered Extension Units
User's Manual - Hardware Edition
15.7
15.7 FX2N-32ES
FX2N-32ES
15.7.1 Product specifications The generic specifications are the same as those for the main unit. → Refer to Section 4.1 for generic specifications. For external wiring, refer to the following chapters. → Refer to Chapter 9 for power supply wiring. → Refer to Chapter 10 for input wiring. → Refer to Chapter 12 for output wiring.
1. Power supply specifications → For the power supply specifications, refer to Section 15.2.
2. Input specifications (sink input) Item
FX2N-32ES
Input points
16 points
Connection type
Removable terminal block (M3 screw)
Input form sink
Input signal voltage
24V DC
Input signal current
5mA/24V DC
Input impedance Input response time
10%
4.3 k Input ON current Input OFF current
3.5mA or more/24V DC 1.5mA or less
Input response time
Approx. 10ms
Input signal form
No-voltage contact input NPN open collector transistor
Input circuit insulation Indication of input operation
Photo-coupler insulation LED on panel lights when input.
Sink input wiring L N 24+ COM
Input circuit diagram
4.3k
206
X
Fuse
100 to 240V AC
Page 213
FX3G Series Programmable Controllers
15 Input/Output Powered Extension Units
User's Manual - Hardware Edition
15.7 FX2N-32ES
11
Item
High-Speed Counters
3. Output specifications (triac output type) FX2N-32ES
Output Points
16 points
Connection type
Removable terminal block (M3 screw)
Output unit
12
Triac output (SSR) 85 to 242V AC
Output circuit insulation
Photo-thyristor insulation
Indication of output operation Resistance load
Max. load
Activation of the photo-thyristor will light the LED indicator lamp on panel. 0.3A/point The total load current per common terminal should be the following value. • 4 output points/common terminal: 0.8A or less
Inductive load
13
15VA/100V AC, 30VA/200V AC 1mA/100V AC, 2mA/200V AC
Min. load
0.4VA/100V AC, 1.6VA/200V AC OFF ON
1ms or less
ON OFF
10ms or less
Wiring for Various Uses
Open circuit leakage current
Response time
Output Wiring
External power supply
14 DC power supply
Output circuit configuration
Fuse
Test Run, Maintenance, Troubleshooting
Load Y COM
A common number applies to the
15 of [COM ].
Input/Output Powered Extension Units
15.7.2 External dimensions 2- 4.5 mounting holes
16
90 (3.55")
Input/Output Extension Blocks
17 Extension Power Supply Unit
80 (3.15") (mounting hole pitch)
Unit : mm (inches)
9 (0.36")
140 (5.52") (mounting hole pitch) 150 (5.91")
87 (3.43")
18
15.7.3 Terminal layout
N
Other Extension Units and Options
L
COM X0 X2 X4 X6 X0 X2 X4 X6 24+ X1 X3 X5 X7 X1 X3 X5 X7
FX2N-32ES Y4 Y6
Y0 Y2
Display Module
Y0 Y2
19 Y4 Y6
COM1 Y1 Y3 COM2 Y5 Y7 COM3 Y1 Y3 COM4 Y5 Y7
20 Terminal Block
207
Page 214
FX3G Series Programmable Controllers
15 Input/Output Powered Extension Units
User's Manual - Hardware Edition
15.8
15.8 FX2N-48ER-UA1/UL
FX2N-48ER-UA1/UL
15.8.1 Product specifications The generic specifications are the same as those for the main unit. → Refer to Section 4.1 for generic specifications. For external wiring, refer to the following chapters. → Refer to Chapter 9 for power supply wiring. → Refer to Chapter 10 for input wiring. → Refer to Chapter 12 for output wiring.
1. Power supply specifications → For the power supply specifications, refer to Section 15.2.
2. Input specifications (100V AC Input) Item
FX2N-48ER-UA1/UL
Input points
24 points
Connection type
Removable terminal block (M3 screw)
Input form
AC input
Input signal voltage
100 to 120V AC +10%,-15% 50/60 Hz
Input signal current
4.7 mA/100V AC 50 Hz (70% or less when turned on simultaneously) 6.2 mA/110V AC 60 Hz (70% or less when turned on simultaneously)
Input impedance
Approx. 21 k /50 Hz Approx. 18 k /60 Hz
Input response time
Input ON current
3.8mA or more/80V AC
Input OFF current
1.7mA or less/30V AC
Input response time
Approx. 25 to 30ms
Input signal form Input circuit insulation Indication of input operation
Contact input Photo-coupler insulation LED on panel lights when input.
L N
Fuse
100 to 240V AC Input circuit diagram
COM *1 X *1 Input impedance
208
Page 215
FX3G Series Programmable Controllers
15 Input/Output Powered Extension Units
User's Manual - Hardware Edition
15.8 FX2N-48ER-UA1/UL
11
Item
High-Speed Counters
3. Output specifications (relay output type) FX2N-48ER-UA1/UL
Output Points
24 points
Connection type
Removable terminal block (M3 screw)
Output unit
Relay
External power supply Output circuit insulation
Mechanical insulation
Indication of output operation
Supplying power to the relay coil will light the LED indicator lamp on panel.
Resistance load
80VA → For the product life, refer to Subsection 14.4.3. → For cautions on external wiring, refer to Subsection 12.1.2.
Inductive load Open circuit leakage current
-
Min. load
14
5V DC, 2mA (reference value) OFF ON
Approx. 10ms
ON OFF
Approx. 10ms
Y
Test Run, Maintenance, Troubleshooting
Response time
COM
15
Load DC power supply
Input/Output Powered Extension Units
Fuse
Output circuit configuration
External power supply
Y
COM Fuse A common number applies to the of [COM
16
].
Input/Output Extension Blocks
15.8.2 External dimensions 4- 4.5 mounting holes
17
90 (3.55")
Extension Power Supply Unit
80 (3.15") (mounting hole pitch)
Unit : mm (inches)
18 Other Extension Units and Options
9 (0.36")
210 (8.27") (mounting hole pitch) 220 (8.67")
87 (3.43")
19
15.8.3 Terminal layout N
X1 X3 X5 X7
X0 X2 X4 X6 X1 X3 X5 X7
Display Module
COM COM X0 X2 X4 X6
L
13 Wiring for Various Uses
Max. load
2A/point The total load current of resistance loads per common terminal should be the following value. • 4 output points/common terminal: 8A or less • 8 output points/common terminal: 8A or less
12 Output Wiring
30V DC or less 240V AC or less (250V AC or less when the unit does not comply with CE, UL or cUL standards)
X0 X2 X4 X6 X1 X3 X5 X7
FX2N-48ER-UA1/UL Y0 Y2 Y4 Y6 COM3 Y1 Y3 COM4 Y5 Y7
20
Y0 Y2 Y4 Y6 COM5 Y1 Y3 Y5 Y7
Terminal Block
Y0 Y2 Y4 Y6 COM1 Y1 Y3 COM2 Y5 Y7
209