For the Mitsubishi FX1S-14MR-ES/UL

Page 33

Farbprofil: Deaktiviert Komposit Standardbildschirm

/// HIGH SPEED COUNTER

¨ FX1S ¨ FX1N þ FX2N þ FX3U

왎 High-Speed Counter Modules FX2N-1HC

Specifications Signal level Counter inputs Max. counting frequency Input format Type of counter

FX2N -1HC kHz bit 16 bit 32 bit

Counting range Output type Power supply

5 V DC 24 V DC

Related I/O points Weight Dimensions (W x H x D)

kg mm

Order information

FX2N-1HC 5, 12, 24 V DC / 7 mA 2 (1 phase) or 1 (2 phase) 50 16, 32 Up/down counter, ring counter 0 – 65535 -2147483648 – +2147483647 2 x transistor (5 – 24 V DC; 0.5 A) 90 mA (from base unit), 8 0.3 55 x 90 x 87

Art. no. 65584

왎 High-Speed Counter Adapters

¨ FX1S ¨ FX1N ¨ FX2N þ FX3U FX3U-4HSX-ADP, FX3U-2HSY-ADP These adapter modules allow direct processing of positioning application data. The FX3U-4HSX-ADP provides high speed counter input up to 200 kHz while the FX3U-2HSY-ADP delivers 2 channels of pulse train outputs up to 200 kHz.

FX3U-2HSX-ADP

Note: These adapters can only be used with the FX3U and they require a function extension board.

POWER

X0/3 X2/5 X1/4 X6/7

FX3U-4HSX-ADP 4, 1 ch 1 input or kHz 1 ch 2 inputs: 200 2 ch 2 inputs: 100 kHz, Differential line receiver (AM26C32 is suitable) Photocoupler isolation on inputs

X1/4

+

-

X0/3

+

Specifications Counter

X2/5

+

-

FX3U -2HSY-ADP

+

Y4/6 Y5/7

SG SG

X6/7

Y0/2 Y1/3

-

-

POWER inputs outputs

FP.RP

Max. counting frequency

PLS DIR inputs

-Y4/6 +

-Y0/2 + outputs Input format

SGB

- Y5/7 +

- Y1/3 +

SGA

FX3U-4HSX-ADP

Output format

FX3U-2HSY-ADP, Maximum cable length Input potential Output load Maximum connectivity 5 V DC Power supply 24 V DC Related I/O points Weight Dimensions (W x H x D)

m 10 5 V DC, 2 30 mA (from base unit) 30 mA (from base unit) 0 kg 0.08 mm 17.6 x 90 (106) x 89.5

Order information

Art. no. 165274, 200, Differential line driver (AM26C31 is suitable) Normal rotation pulse train, reverse pulse train or pulse train + one 10, less than 25 mA 2 30 mA (from base unit) 60 mA (from base unit) 0 0.08 17.6 x 90 (106) x 89.5 165275

33

MITSUBISHI ELECTRIC FX1-Cat 2006 Euro GB23-44.prn FX1-Cat 2006 Euro GB Donnerstag, 20. April 2006 20:20:58

FX3U-2HSY-ADP, 2

33

SPECIAL FUNCTION MODULES

In addition to the internal high-speed MELSEC FX counters, the high-speed counter module FX2N-1HC provides the user with an external counter. It counts 1- or 2-phase pulses up to a frequency of 50 kHz. The counting range covers either 16 or 32 bit. The two integrated transistor outputs can be switched independently of one another by means of internal comparison functions. Hence, simple positioning tasks can also be realized economically.In addition,the FX2N-1HC can be used as a ring counter.

Page 34

Farbprofil: Deaktiviert Komposit Standardbildschirm

POSITIONING MODULES ///

¨ FX1S ¨ FX1N þ FX2N þ FX3U

왎 Positioning Modules FX2N-1PG-E, FX2N-10PG

POWER ERROR

FX 2N -10PG

START DOG X0 X1 øA øB

PGO FP RP CLR

The positioning modules FX2N-1PG-E and FX2N-10PG are extremely efficient single-axis positioning modules for controlling either step drives or servo drives (by external regulator) with a pulse chain. They are very suitable for achieving accurate positioning in combination with the MELSEC FX series. The configuration and allocation of the position data are carried out directly via the PLC program. A very wide range of manual and automatic functions are available to the user.

Specifications

FX2N-1PG-E

Accessible axes

1

Output frequency pulse/s 10 – 100 000

Signal level for digital inputs Power supply

1 1 – 1 000 000

24 V DC / 40 mA

5 V DC / 100 mA; 24 V DC / 70 mA

5 V DC

55 mA (from base unit)

120 mA (from base unit)

24 V DC, - 8

8

Related I/O points

SPECIAL FUNCTION MODULES

FX2N-10PG

Weight kg 0.3

0.2

Dimensions (W x H x D)

mm 43 x 90 x 87

43 x 90 x 87

Order information

Art. no. 65583

140113

¨ FX1S ¨ FX1N ¨ FX2N þ FX3U

왎 Positioning Module for SSCNET SSCNET III Module FX3U-20SSC-H

INT 0 INT 1 A B

START DOG INT 0 INT 1 A B

X READY Y READY X ERROR Y ERROR

POWER

The SSCNET module FX3U-20SSC-H can be used in combination with a FX3U programmable controller to achieve a cost effective solution for high precision, high speed positioning. The plug-and-play fiber optic SSCNET cabling reduces setup time and increases control distance for positioning operations in a wide range of applications. Servo parameters and positioning information for the FX3U-20SSC-H are easily set up with an FX3U base unit and a personal computer.For parameter setting,monitoring and testing the easy programming software FX Configurator-FP is available. Note: The FX3U-20SSC-H can only be used in combination with a FX3U series base unit. For applicable servo amplifiers and motors please refer to the Mitsubishi servo catalogue.

FX2CU-20SSC-H

Specifications Accessible axes Output frequency Pulse output format Communications speed Starting time Max. to PLC connectable modules Status displays 5 V DC Power supply 24 V DC Related I/O points Weight Dimensions (W x H x D) Order information

Art. no. 168914

34

FX1-Cat 2006 Euro GB23-44.prn FX1-Cat 2006 Euro GB Donnerstag, 20. April 2006 20:21:04

FX3U-20SSC-H 2 (independent or interpolation) 1 Hz to 50 MHz SSCNET III (servo bus) 50 Mbps 1.6 (+1.7 SSCNET cycle time) Up to 8 can be connected to the FX3U PLC Power, module status, axis status, error 100 mA, 8 kg 0.3 mm 55 x 90 x 87

MITSUBISHI ELECTRIC 34

Page 35

Farbprofil: Deaktiviert Komposit Standardbildschirm

/// NETWORK MODULES

¨ FX1S þ FX1N þ FX2N þ FX3U

왎 Network Modules for CC-Link

CC-Link Master Module FX2N-16CCL-M The CC-Link network enables the controlling and monitoring of decentralized I/O modules at the machine. The CC-Link master module FX2N-16CCL-M is a special extension block which assigns an FX series PLC as the master station of the CC-Link system. The setting of all modules within the network is handled directly via the master module. Up to 15 remote stations and remote device stations can be connected to the master station as decentralized I/O stations. These remote stations can be up to 7 I/O modules and up to 8 intelligent modules. 2 master modules can be connected to one FX1N or FX2N base unit. The maximum communications distance is 1200 m without repeater.

RUN ERR. MST TEST 1 TEST 2 L RUN L ERR.

CC-LINK

FX2n-16CCL-M

Note: Refer to the Mitsubishi Electric Network catalog for I/O blocks and power supply units.

SW M/S PRM TIME LINE

Specifications Module type

Max. number of I/O points Number of connectable modules 5 V DC Power supply 24 V DC Related I/O points Weight Dimensions (W x H x D)

FX2N-16CCL-M Master station I/O points 32 register 8 128 (with FX1N PLC), 256 (with FX2N PLC), 384 (with FX3U PLC)* Max. 15, 150 mA 8 0.4 85 x 90 x 87

Order information

Art. no. 133596

Link points per station

*Including I/O points in PLC and network.

CC-Link Communication Module FX2N-32CCL The communication module FX2N-32CCL enables the user to connect to the CC-Link network with a superior PLC system as master CPU. This gives him access to the network of all MELSEC PLC systems and frequency inverters and to additional products from other suppliers. Thus the network is expandable via the digital inputs/outputs of the FX modules to a maximum of 256 I/Os. The buffer memory of the FX2N-32CCL is read and written by FROM/TO instructions. The connection is to the extension bus on the right side of the controller. FX2N-32CCL

Note: Refer to the Mitsubishi Electric Network catalog for I/O blocks and power supply units.

LRUN • LERR • RD • SD

Specifications Module type

Max. number of I/O points Number of connectable modules 5 V DC Power supply 24 V DC Related I/O points Weight Dimensions (W x H x D)

FX2N-32CCL Remote station I/O points 32 register 8, - max. 130 mA (from base unit) 50 mA 8 0.3 43 x 90 x 87

Order information

Art. no. 102961

Link points per station

35

MITSUBISHI ELECTRIC FX1-Cat 2006 Euro GB23-44.prn FX1-Cat 2006 Euro GB Donnerstag, 20. April 2006 20:21:10

35

SPECIAL FUNCTION MODULES

SD RD

Page 36

Farbprofil: Deaktiviert Komposit Standardbildschirm

NETWORK MODULES ///

¨ FX1S þ FX1N þ FX2N þ FX3U

왎 Network Module for AS-Interface AS-Interface Module FX2N-32ASI-M

The FX2N-32ASI-M serves as master module for the connection of the FX1N/FX2N and FX3U PLC to the AS-Interface system. Up to 31 slave units with up to 4 inputs and 4 outputs can be controlled.

U ASI ASI ACTIVE

POWER ADRESS/ERROR

FX2N -32ASI-M PRJ MODE PRG ENABLE FROM/TO CONFIG ERR

Specifications Module type Max. number of I/O points Communication protocol Communication speed Method Communication cable Total extension distance

SPECIAL FUNCTION MODULES

Max. number of controllable units I/O refresh time Network setup Display 5 V DC Power supply 24 V DC Related I/O points Weight Dimensions (W x H x D) Order information

FX2N-32ASI-M Master module 128 (with FX1N PLC); 256 (with FX2N/FX3U PLC)* AS-Interface standard kbps 167 APM method (Alternating Pulse Modulation) AS-Interface standard cable (up to 2 repeaters can be used on the system. The total extension distance may m 100 be extended by 100m for each repeater.) Up to 31 slave modules (up to 4 inputs / 4 outputs per slave) Max. 5 ms 2 key network setup 7-segment display for status and diagnosis messages 150 mA (from base unit) 70 mA external 8 kg 0.2 mm 55 x 90 x 87 Art. no. 103314

*Including I/O points in PLC and network.

36

FX1-Cat 2006 Euro GB23-44.prn FX1-Cat 2006 Euro GB Donnerstag, 20. April 2006 20:21:13

MITSUBISHI ELECTRIC 36

Page 37

Farbprofil: Deaktiviert Komposit Standardbildschirm

/// NETWORK MODULES

þ FX1S þ FX1N þ FX2N ¨ FX3U

왎 Network Module for Ethernet

Ethernet Communications Adapter FX2NC-ENET-ADP The FX2NC-ENET-ADP communications adapter is an Ethernet interface with 10BASE-T specifications for the FX1S, FX1N and FX2N series. The FX2NC-ENET-ADP enables upload, download, monitor and test sequence of programs via Ethernet from a personal computer (GX Developer or MX Component and the virtual COM port driver installed).

FX2NC-ENET-ADP

POWER LINK

SD RD

Specifications Protocol No. of simultaneous open connections Interface Connector Max. transfer rate Cable Related I/O points 5 V DC Power supply 24 V DC Weight Dimensions (W x H x D) Order information

FX2NC-ENET-ADP TCP/IP 1 IEEE802.3u (100BaseTX), IEEE802.3 (10BaseT) RJ45 (to Ethernet), 3 screw terminals (to ground) 10 Mbit/s CAT5 STP or 3 STP 0 135 mA (from base unit), kg 0.1 mm 19.1 x 90 x 78 Art. no. 157447

왎 Network Module for Ethernet

¨ FX1S ¨ FX1N ¨ FX2N þ FX3U Ethernet Communications Module FX3U-ENET

RUN INIT. 100M SD RD ERR. COM.ERR.

The FX3U-ENET communications module provides the FX3U with a direct connection on to an Ethernet network. With the FX3U-ENET installed an FX3U PLC can exchange data quickly and easily with process visualization systems in addition to supporting full program UP/DOWN load as well as comprehensive monitoring support. The module also supports Peer to Peer connection and MC Protocol. It is easily set-up with the FX Configurator-EN software. Note: The FX3U-ENET can only be used in combination with a FX3U series base unit.

POWER

FX3U-ENET 10BASE-T/100BASE-TX

C1 C2 C3 C4 C5 C6 C7 C8

Specifications Protocol Communication mode No. of simultaneous open connections Fixed buffer communication Communication with mail server Interface Connector Max. transfer rate Max. segment length Cable 5 V DC Power supply 24 V DC Related I/O points Weight Dimensions (W x H x D) Order information

Art. no. 166086

37

MITSUBISHI ELECTRIC FX1-Cat 2006 Euro GB23-44.prn FX1-Cat 2006 Euro GB Donnerstag, 20. April 2006 20:21:20

FX3U-ENET TCP/IP, UDP Full-duplex / half-duplex 8 1023 word x 8 SMTP, POP3 IEEE802.3u (100BaseTX), IEEE802.3 (10BaseT) RJ45 100 Mbits/s, 10 Mbit/s m 100 CAT5 STP or 3 STP, 240 mA (from base unit) 8 kg 0.3 mm 55 x 90 x 87

37

SPECIAL FUNCTION MODULES

Note: When connecting this adapter module to a FX1S or FX1N PLC the communications adapter FX1N-CNV-BD is required. When connecting this adapter module to a FX2N PLC the communications adapter FX2N-CNV-BD is required.

ACT

Page 38

Farbprofil: Deaktiviert Komposit Standardbildschirm

NETWORK MODULES ///

¨ FX1S þ FX1N þ FX2N þ FX3U

왎 Network Module for Profibus/DP Slave Module FX0N-32NT-DP

SPECIAL FUNCTION MODULES

FX 0N -32NT-DP RUN

POWER

DC

BF

DIA

The FX0N-32NT-DP PROFIBUS/DP slave module enables you to integrate a MELSEC FX1N/FX2N/FX2NC or FX3U in an existing PROFIBUS/DP network. This interface module provides your FX1N, FX2N or FX3U CPU with an intelligent PROFIBUS/DP link for the implementation of decentralised control tasks. It links the system to the master PLC in the PROFIBUS/DP network for efficient and trouble-free data exchange.

Specifications Module type Interface Communications speed Profibus specifications Communications distance Communication cable 5 V DC Power supply 24 V DC Related I/O points Weight Dimensions (W x H x D)

FX0N-32NT-DP Slave PROFIBUS/DP (with 9 pole D-SUB connector) PROFIBUS standard PROFIBUS standard m Max. 1,200 (depends on communication speed) PROFIBUS cable with 9-pin D-SUB connector max. 170 mA (from base unit) 60 mA 8 kg 0.3 mm 43 x 90 x 87

Order information

Art. no. 62125 PROFIBUS connector up to 12 Mbaud: PROFICON-PLUS, art. no. 140008 or PROFICON-PLUS-PG, art. no. 140009

Accessories

왎 Network Module for Profibus/DP

¨ FX1S ¨ FX1N ¨ FX2N þ FX3U

Master module FX3U-64DP-M

RUN

The FX3U-64DP-M PROFIBUS/DP master module enables you to integrate a MELSEC FX3U PLC system as a class 1 master of a PROFIBUS/DP network. This interface module provides your FX3U CPU with an intelligent Profibus/DP link for the implementation of decentralised control tasks. The FX3U Profibus/DP master provides comprehensive data and alarm processing to the Profibus/DP V1 standard. It is easily set up with the GX Configurator-DP software.

TOKEN FROM/TO

Note: The FX3U-64DP-M can only be used in combination with a FX3U series base unit.

ERROR POWER

FX 3U -64DP-M

Specifications Module type Transmission type Transmission data Interface Max. number of master per configuration Repeaters Max. number of slaves Communications speed Communications distance Communication cable 5 V DC Power supply 24 V DC Related I/O points Weight Dimensions (W x H x D) Order information

Art. no. 166085 PROFIBUS connector up to 12 Mbaud: PROFICON-PLUS, art. no. 140008 or PROFICON-PLUS-PG, art. no. 140009

Accessories

38

FX1-Cat 2006 Euro GB23-44.prn FX1-Cat 2006 Euro GB Donnerstag, 20. April 2006 20:21:26

FX3U-64DP-M Master Bus network 32 byte/slave (normal service mode) 244 byte/slave (extended service mode) PROFIBUS/DP (with 9 pole D-SUB connector) 1 3 64 PROFIBUS standard m Max. 1,200 (depends on communication speed) PROFIBUS cable with 9-pin D-SUB connector, max. 155 mA (from base unit) 8 kg 0.2 mm 43 x 90 x 87

MITSUBISHI ELECTRIC 38

Page 39

Farbprofil: Deaktiviert Komposit Standardbildschirm

/// NETWORK MODULES

왎 Remote I/O Station for PROFIBUS/DP Remote I/O Station FX2N-32DP-IF

RUN STOP

L

COM N

24 +

MITSUBISHI POWER RUN BF

The remote I/O station FX2N-32DP-IF forms an extremely compact communication unit and provides a connection of I/O modules with up to 256 I/O points and/or up to 8 special function modules as an alternative. It features an entire electrical isolation of the PROFIBUS/DP connector and of the sensor/actuator circuits. The FX2N-32DP-IF includes a 240 V power supply unit and a 24 V service voltage terminal, e.g. for analog modules. The FX2N-32DP-IF-D is supplied with 24 V DC. PROFIBUS data such as the baud rate or I/O data can be monitored directly with the programming software or on the hand-held programming unit FX-20P-E. This facilitates an easy error diagnosis directly on the remote I/O station.

DIA

ON OFF

Specifications

FX2N-32DP-IF FX2N-32DP-IF-D 100 – 240 V AC 24 V DC (+10 % / -15 %) 50/60 Hz (+20 % / -30 %) 30 VA 14 W 5 V DC / max. 220 mA (from base unit), 5 V DC / max. 220 mA (from base unit) 24 V DC / 500 mA 9-pin D-SUB for PROFIBUS/DP, 8-pin Mini-DIN for PC or programming unit FX-20P-E

Power supply Power consumption Internal current consumption Interface (connectors)

Communication speed distance 1200 m 1000 m 400 m 200 m 100 m

Communication distance Communication cable Max. number of controllable I/O points Related I/O points Weight Dimensions (W x H x D) Order information

9.6 / 19.2 / 45.45 / 93.75 187.5 500 1500 3000 / 6000 / 12000 Max. 1200 (depends on communication speed) PROFIBUS cable with 9-pin D-SUB connector 256 0 kg 0.4 mm 75 x 98 x 87

Art. no. 103705

142763

39

MITSUBISHI ELECTRIC FX1-Cat 2006 Euro GB23-44.prn FX1-Cat 2006 Euro GB Donnerstag, 20. April 2006 20:21:30 kbps kbps kbps kbps kbps m

39

SPECIAL FUNCTION MODULES

64 32 16 8 4 2 1

FX2N-32DP-IF

Page 40

Farbprofil: Deaktiviert Komposit Standardbildschirm

NETWORK MODULES ///

¨ FX1S ¨ FX1N þ FX2N þ FX3U

왎 Network Module for DeviceNet

DeviceNet Slave Module FX2N-64DNET

POWER

The DeviceNet slave module FX2N-64DNET can be used to connect FX2N and FX3U programmable controllers to a DeviceNet network. The FX2N-64DNET can communicate to the master by the master/slave communication (using the master/slave I/O connection), and to other nodes supporting the UCMM connection by client/server communication (using the UCMM connection). The communication between the programmable controller and the internal buffer memory of the FX2N-64DNET is handled by FROM/ TO instructions.

FX 2N -64DNET

/TO MS NS

Specifications Module type Node type Station numbers Supported communication speeds

SPECIAL FUNCTION MODULES

Communication data (open connection)

Master/ slave UCMM client/server

Communication data (I/O connection)

kbps no. of connections transfer time-out no. of connections data length type data length

Module ID code Status displays Related I/O points 5 V DC 24 V DC

Power supply Weight Dimensions (W x H x D) Order information

Art. no. 131708

40

FX1-Cat 2006 Euro GB23-44.prn FX1-Cat 2006 Euro GB Donnerstag, 20. April 2006 20:21:33 mA kg mm

FX2N-64DNET Slave (group 2) G2 Server 0 – 63 points 125 / 250 / 500 1 connection (group 2) 2,000 ms (ACK time-out) 63/63 (group 1, 3) Max. 64 bytes per connection Polling, cyclic, change of state Max. 64 bytes (fragmentation is possible) K 7090 Power, module status, network status 8 120 mA 50 mA 0.2 43 x 90 x 87

MITSUBISHI ELECTRIC 40

Page 41

Farbprofil: Deaktiviert Komposit Standardbildschirm

/// NETWORK MODULES

¨ FX1S ¨ FX1N þ FX2N þ FX3U

왎 Network Module for CANopen

RUN FROM/TO Tx/Rx ERROR

POWER

The FX2N-32CAN communications module makes it possible to connect an FX1N, FX2N or FX3U PLC to an existing CANopen network. In addition to real-time capabilities and high-speed data transfer at rates of up to 1Mbit/s the CANopen module also shines with high transfer reliability and simple network configuration. Up to 120 data words can be sent and received as process data objects (30 PDOs). The number of words that can be transmitted in each direction can be set between 1 and 120. Communication with the module’s memory buffer is performed with simple FROM/TO instructions.

FX2N -32CAN

FX2N-32CAN CANopen master 5 V DC (via base unit) ISO 11898/1993 DS-301 version 3.0 NMT, Guarding, and Guarding request based on DS-302 V2.0. network variables based on DS-405 V1.0

Additional CANopen features Max. nbr. of modules that can be connected to the network Station numbers Supported baud rate kBaud Status displays Related I/O points 5 V DC Power supply 24 V DC Weight kg Dimensions (W x H x D) mm Order information

1 – 127 10, 20, 50, 125, 250, 500, 800, 1000 RUN, Error, Power, Network status 8 290 mA, 0.2 43 x 90 x 88.7

Art. no. 141179

41

MITSUBISHI ELECTRIC FX1-Cat 2006 Euro GB23-44.prn FX1-Cat 2006 Euro GB Donnerstag, 20. April 2006 20:21:37

30 without repeater; 127 with repeater

SPECIAL FUNCTION MODULES

Specifications Module type Power supply CAN standard CANopen standard by CiA

41

Page 42

Farbprofil: Deaktiviert Komposit Standardbildschirm

COMMUNICATIONS MODULES ///

¨ FX1S ¨ FX1N þ FX2N ¨ FX3U

왎 Communications Adapter Interface Adapters FX2N-CNV-IF

The FX2N-CNV-IF interface allows standard FX expansion blocks and special function modules to be connected to an FX2N PLC. MITSUBISHI

FX2N-CNV-IF

Applicable for Bus connection Weight Dimensions (W x H)

Base units FX2N FX2N bus to FX bus kg 0.3 mm 140 x 25 x 45

Order information

Art. no. 65598

þ FX1S þ FX1N þ FX2N þ FX3U

왎 Communications Modules

Communications Modules FX2NC-485ADP, FX3U-485ADP The communication modules FX2NC-485ADP and FX3U-485ADP enable the configuration of 1:n multidrop, parallel link or peer-to-peer networks using the RS485 interface. Note: The FX2NC-485ADP requires a FX2N-CNV-BD or FX1N-CNV-BD interface adapter when connecting to a FX1S, FX1N or FX2N base unit. The FX3U-485ADP can only be used with the FX3U and requires a function extension board.

FX2NC-485ADP

POWER RD SD

FX3U -485ADP

POWER RD SD

RDA RDB SDA SDB 330 OPEN

SG

110

SG

SDB

SDA

RDB

RDA

SPECIAL FUNCTION MODULES

FX2N -CNV-IF

Specifications

FX2NC-485ADP FX3U-485ADP

Specifications Interface Communication speed* Communication distance 5 V DC Power supply 24 V DC Related I/O points Weight Dimensions (W x H x D)

kbps m kg mm

Order information

FX2NC-485ADP RS485 0.3 – 19.2 500 max. 150 mA (from base unit), 0 0.1 19.1 x 90 x 78

Art. no. 149111

FX3U-485ADP RS485 0.3 – 115.2 500 20 mA (from base unit), 0 0.08 17.6 x 90 (106) x 89.5 165277

* Speed depends on communication method (Parallel link, N:N Network, No protocol, Dedicated protocol)

42

FX1-Cat 2006 Euro GB23-44.prn FX1-Cat 2006 Euro GB Donnerstag, 20. April 2006 20:21:45

MITSUBISHI ELECTRIC 42